OnCommand Unified Manager 6.2

Size: px
Start display at page:

Download "OnCommand Unified Manager 6.2"

Transcription

1 OnCommand Unified Manager 6.2 Installation and Setup Guide For Red Hat Enterprise Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S. Telephone: +1 (408) Fax: +1 (408) Support telephone: +1 (888) Web: Feedback: Part number: _C0 August 2015

2

3 Table of Contents 3 Contents Introduction to Unified Manager installation and setup on Red Hat Enterprise Linux... 5 How Unified Manager works with Red Hat Enterprise Linux... 5 Contents of the Unified Manager installation package for Red Hat Enterprise Linux... 6 What the umadmin users do... 6 What AutoSupport does... 7 Requirements for Unified Manager on Red Hat Enterprise Linux... 8 Supported browsers and platforms... 9 Protocol and port requirements Installing Unified Manager on Red Hat Enterprise Linux Users created in Unified Manager Downloading and installing Unified Manager on a blank Red Hat Enterprise Linux system Downloading and installing Unified Manager on a fully configured Red Hat Enterprise Linux system Downloading and installing Unified Manager on a partially configured Red Hat Enterprise Linux system Configuring after installation Configuring initial settings Configuring your environment after initial setup Configuring Unified Manager to send alert notifications Configuring notification settings Enabling remote authentication Disabling nested groups from remote authentication Adding authentication servers Testing the configuration of authentication servers Editing global threshold settings Adding a user Adding clusters Adding an alert Changing the umadmin password Setting up a connection between Performance Manager and Unified Manager Creating a user with Event Publisher role privileges Configuring a connection between a Performance Manager server and Unified Manager Deleting a connection between a Performance Manager server and Unified Manager Setting up a connection between OnCommand Workflow Automation and Unified Manager... 38

4 4 OnCommand Unified Manager 6.2 Creating a database user Setting up a connection between OnCommand Workflow Automation and Unified Manager Unified Manager stop, restart, remove, upgrade, or host rename operations in Red Hat Enterprise Linux Stopping and starting Unified Manager in Red Hat Enterprise Linux Removing Unified Manager from Red Hat Enterprise Linux Upgrade overview of Unified Manager 6.2 on Red Hat Enterprise Linux Upgrading to Unified Manager 6.2 from Unified Manager 6.2 RC Changing the Unified Manager host name in Red Hat Enterprise Linux Generating and sending a support bundle if Unified Manager is installed on Red Hat Enterprise Linux Troubleshooting Unified Manager Installation on Red Hat Enterprise Linux Notification of nonsigned software packages during installation on Red Hat Enterprise Linux Unified Manager installation terminates due to MySQL packages upgrade fail notification of initial cron job failure at the end of the Unified Manager Red Hat Enterprise Linux installation operation can be disregarded Adding disk space to the /data directory of the Unified Manager Red Hat Enterprise Linux host Maintenance user is not created during installation if noexec privilege is set in /tmp partition Copyright information Trademark information How to send comments about documentation and receive update notification Index... 53

5 5 Introduction to Unified Manager installation and setup on Red Hat Enterprise Linux You can install Unified Manager on both physical servers or virtual servers running Red Hat Enterprise Linux. Unified Manager supports monitoring of clustered Data ONTAP 8.3 and 8.2.x systems. Unified Manager also supports features, such as vaulting, nondisruptive operations, and Storage Virtual Machines (SVMs) with Infinite Volume. If you configure a connection with a Performance Manager server, you can track the performance incidents discovered by that Performance Manager from within the Unified Manager web UI. If you pair Unified Manager with the Workflow Automation (WFA) server, you can enable automated SnapMirror and SnapVault based data protection operations through Unified Manager. Unified Manager can also be downloaded and installed as a virtual appliance on a VMware ESXi Server. For more information on this type of deployment, see the OnCommand Unified Manager Installation and Setup Guide for VMware Virtual Appliances. For the most current compatibility information, see the Interoperability Matrix. Related tasks Setting up a connection between Performance Manager and Unified Manager on page 34 Setting up a connection between OnCommand Workflow Automation and Unified Manager on page 38 Related information NetApp Interoperability Matrix Tool How Unified Manager works with Red Hat Enterprise Linux Red Hat Enterprise Linux is a commercial-grade operating system. It is one of the supported systems on which you can install and run Unified Manager to monitor and manage your clustered Data ONTAP storage domain. The Red Hat Enterprise Linux server on which you install Unified Manager can be running either on a physical machine or on a virtual machine running on VMware ESXi Server or Microsoft Hyper-V. To install Unified Manager on Red Hat Enterprise Linux, you must first download and run Red Hat package manager modules (RPMs), which are the package formats most often used for installing software applications on the Red Hat OS.

6 6 OnCommand Unified Manager 6.2 Contents of the Unified Manager installation package for Red Hat Enterprise Linux The Unified Manager download web page enables you to download two zipped bundles to install Unified Manager on Red Hat Enterprise Linux: an optional third-party-dependencies bundle, and the main Unified Manager bundle. Contents of the Unified Manager bundle The Unified Manager bundle includes all the modules necessary to install the Unified Manager software on top of the required vendor software not made by NetApp. The contents of this zipped bundle includes the following RPM modules: ocie-serverbase rpm ocie-server rpm ocie-au rpm netapp-ocum rpm Contents of the third-party-dependencies bundle The third-party-dependencies bundle is a zipped file that contains packages for installing Java, MySQL, and other vendor utilities. These utilities are not made by NetApp, but they are necessary to support Unified Manager. If your Red Hat Enterprise Linux system is not already installed with the required utilities and the versions of Java and MySQL necessary to support a Unified Manager installation, you can download and install the contents of this bundle to ensure a successful installation. The contents of this bundle includes RPM packages for the following products: JRE 1.7 MySQL 5.6 Enterprise Edition p7zip rrdtool Related information NetApp Support What the umadmin users do For each instance in which Performance Manager or Unified Manager is installed on Red Hat Enterprise Linux, an initial user, always named "umadmin," is automatically created. The umadmin users are the initial users used to access the Performance Manager web UI or the Unified Manager web UI after installation and from there perform configuration and management functions. umadmin users and customized passwords The name umadmin, whether created for Performance Manager or for Unified Manager, can never be changed; however, the password assigned to each umadmin user can and should be customized immediately after installation. For example, in a storage management infrastructure consisting of a Unified Manager server and two Performance Manager servers, access to the three objects might be configured as follows:

7 Introduction to Unified Manager installation and setup on Red Hat Enterprise Linux 7 The umadmin user for Unified Manager can log in as umadmin but authenticate with a customized password like "UMx9x947." The umadmin user for Performance Manager server 1 will log in as umadmin authenticate with a customized password like "PMz8z831." The umadmin user for Performance Manager server 2 will log in as umadmin authenticate with a customized password like "PMz468RT." The umadmin user OnCommand Administrator role and maintenance user type During an installation of Unified Manager or Performance Manager on a Red Hat Enterprise Linux machine, the associated umadmin user is assigned an OnCommand Administrator user role and configured as the maintenance user type. As such, each umadmin user can perform functions reserved for that role and that type. Performance Manager umadmin user abilities The umadmin user created during Performance Manager installation can perform the following functions: In the OnCommand Administrator role in Performance Manager allows the umadmin user to log in to the Performance Manager web UI and perform all the performance monitoring and troubleshooting operations supported through that interface. As the maintenance user type, the umadmin user can perform the following operations. Start the initial configuration of the Performance Manager web UI. Access the Performance Manager maintenance console and perform all menu operations displayed through that interface, including configuring a connection between Performance Manager and Unified Manager. Unified Manager umadmin user abilities The umadmin user created during Unified Manager installation can perform the following functions: As the OnCommand Administrator, log in to the Unified Manager web UI and perform all the monitoring and configuration operations supported through that interface. As the sole user assigned the maintenance user type, the umadmin user alone is authorized to start the initial configuration of Unified Manager. What AutoSupport does With the help of the AutoSupport feature, Unified Manager sends information to technical support to help with troubleshooting. AutoSupport messages are scanned for potential problems and are available to technical support when they assist you in resolving issues.

8 8 Requirements for Unified Manager on Red Hat Enterprise Linux To ensure successful installation of Unified Manager on Red Hat Enterprise Linux, you must confirm that the system on which Unified Manager is being installed meets certain system and software requirements. System requirements The Red Hat Enterprise Linux system on which you install Unified Manager requires that the following additional capabilities and capacities be reserved to support Unified Manager: Note: These requirements must be met whether the target machine is a virtual machine, running on VMware ESXi Server or Microsoft Hyper-V, or a physical machine. Reserved CPU cycle capacity: 9572 MHz Reserved RAM: 12 GB Reserved free hard disk space: 150 GB, where the capacity is allotted as follows: 50 GB allotted to the root partition of the target system 100 GB of free disk space allotted to the /data directory, which is mounted on an LVM drive or on a separate local disk attached to the target system Important: Mounting the /data directory on an NFS or CIFS share is not supported. This configuration enables you to use a Red Hat Enterprise Linux machine with a smaller root partition and also enables you to expand /data directory storage if required at a later time. If the Red Hat Enterprise Linux target machine has a pre-existing configuration in which the /opt directory and /var/log directory are mounted on a separate partition, you must follow these sizing guidelines: Allocate at least 15 GB for /var/log Allocate at least 5 GB for /opt Allocate at least 12 GB for /tmp Allocate at least 100 GB for /data With this configuration, you can allocate space for root partition as per the best practice guidelines for Red Hat Enterprise Linux. Host connectivity requirement The Red Hat Enterprise Linux physical or virtual system on which you install Unified Manager must be FQDN-configured in such a way that you can successfully ping the host name from the host itself. You can use the host name (or the host IP address) to access the product web UI. If you configured a static IP address for your network during deployment, then you would have designated a name for the network host. If you configured the network using DHCP, the host name should be taken from the DNS.

9 Requirements for Unified Manager on Red Hat Enterprise Linux 9 Software requirements The Red Hat Enterprise Linux system on which you install Unified Manager requires the following versions of the operating system and supporting software installed: Red Hat Enterprise Linux version 6.5 (64-bit) Oracle JRE 1.7.0_79 MySQL Enterprise Edition This version must be supplied by Oracle Corporation or by the downloaded Unified Manager third-party-dependencies bundle. p7zip rrd tool and libraries If you do not have the listed software installed, downloading, unzipping, and installing the thirdparty-dependencies bundle automatically installs these packages. User authorization requirements To perform Unified Manager installation on Red Hat Enterprise Linux, you must be logged in as the root user on the target Red Hat Enterprise Linux system. Restriction: Installation by non-root users using the sudo command is not supported. License requirements No special licenses are required to install Unified Manager on Red Hat Enterprise Linux. Dedicated use requirement The Red Hat Enterprise Linux physical or virtual system on which you install Unified Manager must be used exclusively for Unified Manager and not shared with other applications. Important: This restriction includes Performance Manager. Performance Manager cannot be installed on the same Red Hat Enterprise Linux server on which you are installing Unified Manager. Supported browsers and platforms To use the Unified Manager GUI, you must use a supported browser that runs on a supported client platform. Unified Manager has been tested with the following browsers and client platforms; other browsers might work but have not been qualified. See the Interoperability Matrix at mysupport.netapp.com/ matrix for the complete list of supported browser versions. Supported browsers Microsoft Internet Explorer 10 (Standards mode) or later Google Chrome, versions 36 or later Mozilla Firefox, versions 24 ESR and 31 ESR or later Apple Safari version 7 or later

10 10 OnCommand Unified Manager 6.2 Supported browser client platforms Windows Vista, Windows 7, and Windows 8 Red Hat Enterprise Linux version 6 SUSE Linux Enterprise Server version 11 SP2 Macintosh OS X 10.8 Protocol and port requirements Using a browser, API client, or SSH, the required ports must be accessible to the Unified Manager UI and APIs. The required ports and protocols enable communication between the Unified Manager server and the managed storage systems, servers, and other components. Connections to the Unified Manager server You do not have to specify port numbers when connecting to the Unified Manager web UI, because default ports are always used. For example, because Unified Manager always runs on its default port, you can enter instead of The default port numbers cannot be changed. The Unified Manager server uses specific protocols to access the following interfaces: Interface Protocol Por t Description Unified Manager web UI Unified Manager web UI and programs using APIs Red Hat Enterprise Linux command line HTTP 80 Used to access the Unified Manager web UI; automatically redirects to the secure port 443. HTTPS 443 Used to securely access the Unified Manager web UI or to make API calls; API calls can only be made using HTTPS. SSH/ SFTP MySQL database MySQL Used to access the Red Hat Enterprise Linux command line and retrieve support bundles. Used to enable OnCommand Workflow Automation and OnCommand Report access to Unified Manager. Connections from the Unified Manager server You must configure your firewall to open ports that enable communication between the Unified Manager server and managed storage systems, servers, and other components. If a port is not open, communication fails. Depending on your environment, you can choose to modify the ports and protocols used by the Unified Manager server to connect to specific destinations. The Unified Manager server connects using the following protocols and ports to the managed storage systems, servers, and other components: Destination Protocol Port Description Storage system HTTPS 443 Used to monitor and manage storage systems. AutoSupport server HTTPS 443 Used to send AutoSupport information. Requires Internet access to perform this function.

11 Requirements for Unified Manager on Red Hat Enterprise Linux 11 Destination Protocol Port Description Authentication server LDAP 389 Used to make authentication requests, and user and group lookup requests. Mail server SMTP 25 Used to send alert notification s. SNMP trap sender SNMPv1 or SNMPv3 162/UDP Used to send alert notification SNMP traps.

12 12 Installing Unified Manager on Red Hat Enterprise Linux It is important that you understand that the sequence of steps to download and install Unified Manager on Red Hat Enterprise Linux varies according to your download scenario. Users created in Unified Manager When you install Unified Manager on Red Hat Enterprise Linux, the following users are created by Unified Manager and third-party utilities: umadmin, jboss, mysql, and rrdcache. umadmin jboss mysql The umadmin user is used to log in to Unified Manager for the first time. This user is created by Unified Manager. The jboss user is used to run Unified Manager services related to the jboss utility. This user is created by Unified Manager. The mysql user is used to run MySQL database queries of Unified Manager. This user is created by the MySQL third-party utility. rrdcache The rrdcache user uses the rrdtool to collect Unified Manager health data. This user is created by the rrdtool third-party utility. Apart from these users, Unified Manager also creates their corresponding groups: maintenance, jboss, mysql and rrdcache. The maintenance and jboss groups are created by Unified Manager, while the rrdcache and mysql groups are created by the third-party utilities. Downloading and installing Unified Manager on a blank Red Hat Enterprise Linux system If you want to install Unified Manager on a Red Hat Enterprise Linux platform that is not yet installed with the Java packages, MySQL packages, or utilities necessary to support the installation, you can download zipped bundles that enable you to automatically install Unified Manager and all the additional modules and utilities necessary to support it. The system on which you want to install Unified Manager is running Red Hat Enterprise Linux 6.5 or a later supported version (see the NetApp Interoperability Matrix Tool). The system on which you want to install Unified Manager is configured with a Fully-Qualified Domain Name ( FQDN) such that ping responses to the host name and FQDN are successful. The system on which you want to install Unified Manager is dedicated exclusively to running Unified Manager, not shared with any other application. You can log in as the root user to the Red Hat Enterprise Linux system upon which you want to install Unified Manager. Restriction: Installation by non-root users using the sudo command is not supported.

13 Installing Unified Manager on Red Hat Enterprise Linux 13 You have a supported Internet browser. Your terminal emulation software is scrollback enabled. 1. Use your web browser to navigate to the NetApp Support Site at mysupport.netapp.com, and locate the Download pages for installing Unified Manager on the Red Hat Enterprise Linux platform. 2. Download the Unified Manager bundle (OnCommandUnifiedManager-6.2.zip) to a target directory on the target Red Hat Enterprise Linux system. 3. Download the third-party-dependencies bundle (ThirdPartyDependenices-6.2P1.zip) to the same target directory on the target Red Hat Enterprise Linux system. 4. Log in as the root user to the target Red Hat Enterprise Linux system. 5. Navigate to the target directory and enter the following command to expand the third-partydependencies bundle: unzip thirdpartydependencies-6.2.zip The required RPM modules for Java, MySQL, and supporting utilities are unzipped to the target directory. 6. Still in the target directory, enter the following command to expand the Unified Manager bundle: unzip OnCommandUnifiedManager-6.2.zip The required RPM modules for OnCommand are unzipped to the target directory. 7. Confirm the presence of the listed modules by entering the following command: ls *.rpm The following rpm modules are listed: JRE 1.7.0_79 rpm: jre-7u79-linux-x64.rpm Enterprise Edition MySQL rpms: MySQL-client-advanced el6.x86_64.rpm MySQL-server-advanced el6.x86_64.rpm MySQL-shared-compat-advanced el6.x86_64.rpm p7zip rpm: p7zip x86_64.rpm rrdtool rpms: rrdtool-perl fc13.wrl.x86_64.rpm rrdtool fc13.wrl.x86_64.rpm ocie-serverbase rpm: ocie-serverbase-<version>.x86_64.rpm ocie-server rpm: ocie-server-<version>.x86_64.rpm ocie-au rpm: ocie-au-<version>.x86_64.rpm netapp-ocum rpm netapp-ocum-<version>.x86_64.rpm

14 14 OnCommand Unified Manager Enter the following command: yum install *.rpm This command automatically executes the RPM modules, installing the necessary supporting software and the Unified Manager modules that run on top of them. Caution: Do not attempt installation by use of alternative commands (such as rpm -ivh...). Successful installation of Unified Manager on Red Hat Enterprise Linux requires that all Unified Manager files and related files be installed in a specific order into a specific directory structure that are executed and configured automatically by the "yum install *.rpm" command. 9. After the installation messages are complete, disregard the notification that is displayed immediately following. The notifies the root user of an initial cron job failure that has no adverse effect on the installation. 10. After the installation messages are complete, scroll back the messages until you see the message in which the system displays an IP address or URL for the Unified Manager web UI, the maintenance user name (umadmin), and a default password. The message is similar to the following: OnCommand Unified Manager is successfully installed on the computer. The following login username and password are configured for the OnCommand Unified Manager GUI: username: umadmin password: admin6.2 To change the default password, use the command: passwd umadmin. or Enter the passwd umadmin command to change the umadmin user password from the default "admin6.2" string to a personalized string. 12. Record the IP address or URL, the assigned user name (umadmin), and current password. 13. Optional: If necessary, block access to non-essential open ports. After installation, the following ports, opened during the installation process, are no longer necessary. They are opened during JBoss startup associated with the start of OCIE service. For security purposes they can be blocked from user access by firewall or other means with no impairment to Unified Manager functions Used as the RMI/JRMP socket for connecting to the JMX MBeanServer 1091 Used as the RMI server socket 1098 Used by the Socket Naming service to receive RMI requests from client proxies 1099 Used as the listening socket for the Naming service 4446 Used as JBoss Remoting Connector by UnifiedInvoker 5500 Used for clear/non-ssl Remoting connections

15 Installing Unified Manager on Red Hat Enterprise Linux 15 After you finish After installation is complete, enter the specified IP address or URL into a supported web browser to start the Unified Manager web UI and begin initial configuration. Related concepts What the umadmin users do on page 6 Related references Requirements for Unified Manager on Red Hat Enterprise Linux on page 8 Related information NetApp Support Downloading and installing Unified Manager on a fully configured Red Hat Enterprise Linux system If you want to install Unified Manager on a physical or virtual Red Hat Enterprise Linux platform that is already fully configured with the necessary Java packages, MySQL packages, and utilities, you can download a single zipped bundle that enables you to automatically install Unified Manager on that platform. The system on which you want to install Unified Manager is running Red Hat Enterprise Linux 6.5 or a later supported version (see the NetApp Interoperability Matrix Tool). The system on which you want to install Unified Manager is configured with a fully qualified domain name (FQDN) such that ping responses to the host name and FQDN are successful. The system on which you want to install Unified Manager is dedicated exclusively to running Unified Manager, not shared with any other application. You can log in as the root user to the Red Hat Enterprise Linux system upon which you want to install Unified Manager. Restriction: Installation by non-root users using the sudo command is not supported. You have a supported web browser. Your installation of Red Hat Enterprise Linux has the following additional software installed: Oracle JRE 1.7.0_79 MySQL Enterprise Edition (supplied by Oracle Corporation or with the downloaded Unified Manager third-party-dependencies bundle) p7zip rrd tool and libraries Your terminal emulation software is scrollback enabled. About this task In this context, a Red Hat Enterprise Linux system is fully configured if it has Red Hat Enterprise Linux 6.5 or later installed and has all the required versions of the required additional software already installed.

16 16 OnCommand Unified Manager Log in as the root user to the Red Hat Enterprise Linux server on which you want to install Unified Manager and enter the appropriate commands to verify that the target system has the Java and MySQL versions and utilities required to support installation of Unified Manager. To verify these required software and versions... Oracle JRE 1.7.0_79 MySQL Enterprise Edition (supplied by Oracle Corporation or with the Unified Manager third-party-dependencies bundle) p7zip rrdtool wrl.x86_64 rrdtool-perl wrl.x86_64 Enter this command... java -version rpm -qa grep -i mysql rpm -qa grep p7zip or p7zip x86_64 rpm -qa grep rrd Note: If the required versions of the required software are not installed, see the task titled Downloading and installing Unified Manager on a partially configured Red Hat Enterprise Linux system. 2. Use your web browser to navigate to the NetApp Support Site at mysupport.netapp.com, and locate the Download pages for installing Unified Manager on the Red Hat Enterprise Linux platform. 3. Download the Unified Manager bundle (OnCommandUnifiedManager-6.2.zip) to a target directory on the target Red Hat Enterprise Linux system. 4. Navigate to the target directory and enter the following command to expand the Unified Manager bundle: unzip OnCommandUnifiedManager-6.2.zip The required OnCommand RPM modules are unzipped to the target directory. 5. Confirm the presence of the listed modules by entering the following command: ls *.rpm The following RPM modules are listed: ocie-serverbase rpm: ocie-serverbase-<version>.x86_64.rpm ocie-server rpm: ocie-server-<version>.x86_64.rpm ocie-au rpm: ocie-au-<version>.x86_64.rpm netapp-ocum rpm netapp-ocum-<version>.x86_64.rpm 6. Enter the following command: yum install *.rpm This command automatically executes the RPM modules, installing the Unified Manager modules.

17 Installing Unified Manager on Red Hat Enterprise Linux 17 Caution: Do not attempt installation by use of alternative commands (such as rpm -ivh...). Successful installation of Unified Manager on Red Hat Enterprise Linux requires that all Unified Manager files and related files be installed in a specific order into a specific directory structure that are executed and configured automatically by the "yum install *.rpm" command. 7. After the installation messages are complete, disregard the notification that is displayed immediately following. The notifies the root user of an initial cron job failure that has no adverse effect on the installation. 8. After the installation messages are complete, scroll back the messages until you see the message in which the system displays an IP address or URL for the Unified Manager web UI, the maintenance user name (umadmin), and a default password. The message is similar to the following: OnCommand Unified Manager is successfully installed on the computer. The following login username and password are configured for the OnCommand Unified Manager GUI: username: umadmin password: admin6.2 To change the default password, use the command: passwd umadmin. or 9. Enter the passwd umadmin command to change the umadmin user password from the default "admin6.2" string to a personalized string. 10. Record the IP address or URL, the assigned user name (umadmin), and current password. 11. Optional: If necessary, block non-root user access to non-essential open ports. After installation, the following ports, opened during the installation process, are no longer necessary. They are opened during JBoss startup associated with the start of OCIE service. For security purposes they can be blocked from user access by firewall or other means with no impairment to Unified Manager functions Used as the RMI/JRMP socket for connecting to the JMX MBeanServer 1091 Used as the RMI server socket 1098 Used by the Socket Naming service to receive RMI requests from client proxies 1099 Used as the listening socket for the Naming service 4446 Used as JBoss Remoting Connector by UnifiedInvoker 5500 Used for clear/non-ssl Remoting connections After you finish After installation is complete, enter the specified URL into a supported web browser to start the Unified Manager web UI and begin initial configuration.

18 18 OnCommand Unified Manager 6.2 Related references Requirements for Unified Manager on Red Hat Enterprise Linux on page 8 Related information NetApp Support Downloading and installing Unified Manager on a partially configured Red Hat Enterprise Linux system If you want to install Unified Manager on a physical or virtual Red Hat Enterprise Linux platform that is only partially configured with the necessary Java packages, MySQL packages, and utilities, you can download zipped bundles that enable you to automatically install Unified Manager and upgrade all the third-party modules and utilities necessary to support it. The system on which you want to install Unified Manager is running Red Hat Enterprise Linux 6.5 or a later supported version (see the NetApp Interoperability Matrix Tool). The system on which you want to install Unified Manager is configured with a fully qualified domain name (FQDN) such that ping responses to the host name and FQDN are successful. The system on which you want to install Unified Manager is dedicated exclusively to running Unified Manager, not shared with any other application. You can log in as the root user to the Red Hat Enterprise Linux system upon which you want to install Unified Manager. Restriction: Installation by non-root users using the sudo command is not supported. You have a supported web browser Your installation of Red Hat Enterprise Linux has some version of the following additional software packages installed: Oracle JRE MySQL p7zip rrd tool and libraries Your terminal emulation software is scrollback enabled. About this task In this context, a Red Hat Enterprise Linux system is partially configured if it has Red Hat Enterprise Linux 6.5 or later installed but does not have all required versions of the required supporting software (Java, MySQL, additional utilities) installed. 1. Log in as the root user to the Red Hat Enterprise Linux server on which you want to install Unified Manager and enter the appropriate commands to assess what software might require installation or upgrade on the target system to support:

19 Installing Unified Manager on Red Hat Enterprise Linux 19 Required software and version Oracle JRE 1.7.0_79 MySQL Enterprise Edition p7zip rrdtool wrl.x86_64 rrdtool-perl wrl.x86_64 Command to verify software and version java -version rpm -qa grep -i mysql rpm -qa grep p7zip rpm -qa grep rrd 2. If any version of the listed software is earlier than the required version, enter the appropriate command to uninstall that module: Software to uninstall MySQL (Uninstall any version that is not MySQL Enterprise Edition and not supplied by Oracle Corporation or with the Unified Manager third-party-dependencies bundle) All other modules Command to uninstall rpm -e mysql_package_name yum remove module_name 3. Use your web browser to navigate to the NetApp Support Site at mysupport.netapp.com, and locate the Download pages for installing Unified Manager on the Red Hat Enterprise Linux platform. 4. Download the Unified Manager bundle (OnCommandUnifiedManager-6.2.zip) to a target directory on the target Red Hat Enterprise Linux system. 5. Download the third-party-dependencies bundle (ThirdPartyDependenices-6.2P1.zip) to the same target directory on the target Red Hat Enterprise Linux system. 6. Navigate to the target directory and enter the following command to expand the third-partydependencies bundle. unzip thirdpartydependencies-6.2.zip The required RPM modules for Java, MySQL, and supporting utilities are unzipped to the target directory. 7. Still in the target directory, enter the following command to expand the Unified Manager bundle: unzip OnCommandUnifiedManager-6.2.zip The required RPM modules for OnCommand are unzipped to the target directory. 8. Confirm the presence of the listed modules: ls *.rpm The following RPM modules are listed: JRE 1.7 rpm: jre-7u79-linux-x64.rpm Enterprise Edition MySQL rpms: MySQL-client-advanced el6.x86_64.rpm MySQL-server-advanced el6.x86_64.rpm MySQL-shared-compat-advanced el6.x86_64.rpm p7zip rpm: p7zip x86_64.rpm

20 20 OnCommand Unified Manager 6.2 rrdtool rpms: rrdtool-perl fc13.wrl.x86_64.rpm rrdtool fc13.wrl.x86_64.rpm ocie-serverbase rpm: ocie-serverbase-<version>.x86_64.rpm ocie-server rpm: ocie-server-<version>.x86_64.rpm ocie-au rpm: ocie-au-<version>.x86_64.rpm netapp-ocum rpm netapp-ocum-<version>.x86_64.rpm 9. Enter the following command: yum install *.rpm This command automatically executes the RPM modules, installing the necessary third-party systems and the Unified Manager modules that run on top of them. Caution: Do not attempt installation by use of alternative commands (such as rpm -ivh...). Successful installation of Unified Manager on Red Hat Enterprise Linux requires that all Unified Manager files and related files be installed in a specific order into a specific directory structure that are executed and configured automatically by the "yum install *.rpm" command. 10. After the installation messages are complete, disregard the notification that is displayed immediately following. The notifies the root user of an initial cron job failure that has no adverse effect on the installation. 11. After the installation messages are complete, scroll back the messages until you see the message in which the system displays an IP address or URL for the Unified Manager web UI, the maintenance user name (umadmin), and a default password. The message is similar to the following: OnCommand Unified Manager is successfully installed on the computer. The following login username and password are configured for the OnCommand Unified Manager GUI: username: umadmin password: admin6.2 To change the default password, use the command: passwd umadmin. or Enter the passwd umadmin command to change the umadmin user password from the default admin6.2 string to a personalized string. 13. Record the IP address or URL, the assigned user name (umadmin), and current password. 14. Optional: If necessary, block access to non-essential open ports. After installation, the following ports, opened during the installation process, are no longer necessary. They are opened during JBoss startup associated with the start of OCIE service. For security purposes they can be blocked from user access by firewall or other means with no impairment to Unified Manager functions.

21 Installing Unified Manager on Red Hat Enterprise Linux Used as the RMI/JRMP socket for connecting to the JMX MBeanServer 1091 Used as the RMI server socket 1098 Used by the Socket Naming service to receive RMI requests from client proxies 1099 Used as the listening socket for the Naming service 4446 Used as JBoss Remoting Connector by UnifiedInvoker 5500 Used for clear/non-ssl Remoting connections After you finish After installation is complete, enter the specified URL into a supported web browser to start the Unified Manager web UI and begin initial configuration. Related concepts What the umadmin users do on page 6 Related references Requirements for Unified Manager on Red Hat Enterprise Linux on page 8 Related information NetApp Support

22 22 Configuring after installation After installation of the software is complete, you can log in to the web UI as the default user umadmin, complete an initial setup to configure a minimum software configuration. You can then configure additional options, such as adding alerts, adding users, changing the passwords, and adding clusters you want to monitor. Because the default user umadmin is assigned the OnCommand Administrator user role, that user has authorization to perform any configuration task that is possible through the web UI. Configuring initial settings After the installation of Unified Manager on Red Hat Enterprise Linux is completed, you can access the Unified Manager web UI to configure initial details about the umadmin user and the cluster that user is to manage and monitor. At the end of Unified Manager installation on the target Red Hat Enterprise Linux system, you have the following information: An IP address or URL at which to access the login window to Unified Manager web UI An assigned user name (umadmin) A password for the user umadmin You can specify the following maintenance user information: An address at which the user umadmin can receive alerts and AutoSupport messages The host name of the associated SMTP mail server If you want to specify a cluster for Unified Manager to manage and monitor, you have the following information available about that cluster: Host name or cluster management IP address The host name is the FQDN or short name that Unified Manager uses to connect to the cluster. This host name must resolve to the cluster-management IP address. The cluster-management IP address must be the cluster-management LIF of the admin Storage Virtual Machine (SVM). If you use a node-management LIF, the operation fails. The type of protocol (HTTP or HTTPS) that can be configured on the cluster and the port number of the cluster The port number of the cluster 1. Use a web browser to log in to the Unified Manager web UI, using the IP address or URL, the umadmin user name, and password that you assigned to umadmin during the installation procedure. 2. In the Unified Manager Initial Setup dialog box, choose Yes to enable AutoSupport capabilities and click Continue.

23 Configuring after installation 23 While enabling AutoSupport is a best practice, it is not mandatory. If you do not enable AutoSupport when configuring the initial setup, you can enable it later using the Setup Options dialog box. 3. Type an address for umadmin, the SMTP server host name, and any additional SMTP options, and click Save. The Get Started area appears. 4. To add clusters for monitoring, click Add Cluster. Adding a cluster enables Unified Manager to monitor your cluster components, but alert notifications are not sent until they are configured. After you finish If you choose not to add clusters while configuring initial settings, you can configure additional options, such as alerts and thresholds, and then add clusters for monitoring. Configuring your environment after initial setup After you perform initial setup of the software, there are several configuration tasks that you might want to perform before you start monitoring your clusters, such as adding users, enabling user authentication, and adding alerts. Configuring Unified Manager to send alert notifications You can configure Unified Manager to send notifications that alert you about events in your environment. Before notifications can be sent, you must configure several other Unified Manager options. You must have the OnCommand Administrator role. About this task After deploying Unified Manager and completing the initial configuration, you should consider configuring your environment to trigger alerts and generate notification s or SNMP traps. 1. Configure notification settings on page 24 If you want alert notifications sent when certain events occur in your environment, you must supply an address from which the alert notification can be sent. If your configuration uses an SMTP server for authentication, then you must provide the user name and password for the server. If you want to use SNMP traps, you can select that option and provide the necessary information. 2. Enable remote authentication on page 24 If you want remote LDAP or Active Directory users to access the Unified Manager instance and receive alert notifications, then you must enable remote authentication. 3. Add authentication servers on page 26 If you enable remote authentication, then you must identify authentication servers. 4. Edit global threshold settings on page 27

24 24 OnCommand Unified Manager 6.2 You can modify the threshold settings for aggregates, volumes, and certain types of protection relationships. These settings determine when an event should be generated, which can affect when an alert notification is sent. 5. Add users on page 29 You can add several different types of local or remote users and assign specific roles. When you create an alert, you assign a user to receive the alert notifications. 6. Add alerts on page 31 After you have added the address for sending notifications, added users to receive the notifications, configured your network settings, and configured SMTP and SNMP options needed for your environment, then you can assign alerts. Related concepts What AutoSupport does on page 7 Configuring notification settings You can configure the settings for the Unified Manager server to send alert notifications when an event is generated or when it is assigned to a user. You can configure the corresponding mail server to be used and various notification mechanisms for example, alert notifications can be sent as s or SNMP traps. The following information must be available: address from which the alert notification is sent Host name, user name, password, and default port to configure the SMTP server SNMP version, trap destination host, outbound trap port, and community to configure the SNMP trap You must have the OnCommand Administrator or Storage Administrator role. 1. Click Administration > Setup Options. 2. In the Setup Options dialog box, click General Settings > Notification. 3. Configure the appropriate settings. You can specify the address and SMTP server from which the alert notifications are sent, and enter the SNMP trap settings. Tip: If the host name of the SMTP server cannot be resolved, you can specify the IP address of the SMTP server instead of the host name. Enabling remote authentication You can enable remote authentication, using either Open LDAP or Active Directory, so that the management server can communicate with your authentication servers and so that users of the authentication servers can use Unified Manager to manage the storage objects and data. You must have the OnCommand Administrator role.

25 Configuring after installation 25 About this task If remote authentication is disabled, remote users or groups can no longer access Unified Manager. The only two supported remote authentication methods are Active Directory and Open LDAP. LDAPS is not supported. 1. Click Administration > Setup Options. 2. In the Setup Options dialog box, click Management Server > Authentication. 3. Select Enable Remote Authentication. 4. In the Authentication Service field, select either Active Directory or Open LDAP. If you are using Active Directory as the authentication service, enter the following information: Authentication server administrator name (using one of following formats): domainname\username Bind Distinguished Name (using appropriate LDAP notation) Administrator password Base distinguished name (using the appropriate LDAP notation) If you are using Open LDAP as the authentication service, you can enter the following information: Bind distinguished name (using appropriate LDAP notation) Bind password Base distinguished name If authentication of an Active Directory user takes a long time or times out, the authentication server is probably taking a long time to respond. Disabling support for nested groups in Unified Manager might reduce the authentication time. 5. Optional: Add authentication servers and test the authentication. 6. Click Save and Close. Disabling nested groups from remote authentication If you have remote authentication enabled, you can disable nested group authentication so that only individual users and not group members can remotely authenticate to Unified Manager. You might disable nested groups when you want to improve Active Directory authentication response time. You must be logged in as an Active Directory domain user to perform this task. Logging in as an Active Directory administrator is not required. About this task Disabling support for nested groups in Unified Manager might reduce the authentication time. If nested group support is disabled and if a remote group is added to Unified Manager, individual users must be members of the remote group to authenticate to Unified Manager.

26 26 OnCommand Unified Manager Click Administration > Setup Options. 2. In the Setup Options dialog box, click Management Server > Authentication. 3. In the Authentication Service field, select Others. 4. In the Member field, change the member information from member: : to member. 5. Click Save and Close. Adding authentication servers You can add authentication servers and enable remote authentication on the management server to enable remote users within the authentication server to access Unified Manager. The following information must be available: Host name or IP address of the authentication server Port number of the authentication server You must have enabled remote authentication and configured your authentication service so that the management server can authenticate remote users or groups in the authentication server. You must have the OnCommand Administrator role. About this task If the authentication server that you are adding is part of a high-availability pair (using the same database), you can also add the partner authentication server. This enables the management server to communicate with the partner when one of the authentication servers is unreachable. 1. Click Administration > Setup Options. 2. In the Setup Options dialog box, click Management Server > Authentication. 3. In the Servers area, click Add. 4. In the Add Authentication Server dialog box, specify either the host name or IP address of the server, and the port details. 5. Click Add. Result The authentication server that you added is displayed in the Servers area. After you finish Perform a test authentication to confirm that you are able to authenticate users in the authentication server that you added.

27 Configuring after installation 27 Testing the configuration of authentication servers You can validate the configuration of your authentication servers to ensure that the management server is able to communicate with them. You can validate by searching for a remote user or group from your authentication servers and authenticate them using the configured settings. You must have enabled remote authentication and configured your authentication service so that the OnCommand Unified Manager server can authenticate the remote user or group. You must have added your authentication servers so that the management server can search for the remote user or group from these servers and authenticate them. You must be assigned the OnCommand Administrator role to perform this task. About this task If the authentication service is set to Active Directory and if you are validating the authentication of remote users who belong to the primary group of the authentication server, information about the primary group is not displayed in the authentication results. 1. Click Administration > Setup Options. 2. In the Setup Options dialog box, click Management Server > Authentication. 3. In the Authentication Setup Options dialog box, click Test Authentication. 4. In the Test User dialog box, specify the user name and password of the remote user or group, and then click Test. If you are authenticating a remote group, you must not enter the password. Editing global threshold settings You can configure global threshold conditions for capacity, growth, Snapshot reserve, quotas, and inodes to monitor your aggregate and volume size effectively. You can also edit the settings for generating events for exceeding lag thresholds. About this task Global threshold settings apply to all objects with which they are associated, such as aggregates, volumes, and so forth. When thresholds are crossed, an event is generated and, if alerts are configured, an alert notification is sent. Threshold defaults are set to recommended values, but you can modify them to generate events at intervals to meet your specific needs. When thresholds are changed, events are generated or obsoleted in the next monitoring cycle. Global threshold settings are accessible from the Setup Options dialog box. You can also modify threshold settings for individual objects, from the inventory page or the details page for that object. Choices Configuring global aggregate threshold values on page 28 You can edit the threshold settings for capacity, growth, and Snapshot copies for all aggregates to track any threshold breach. Configuring global volume threshold values on page 28

Installation and Setup Guide

Installation and Setup Guide OnCommand Unified Manager 7.0 Installation and Setup Guide For Red Hat Enterprise Linux July 2016 215-11252_A0 doccomments@netapp.com Table of Contents 3 Contents Introduction to Unified Manager installation

More information

OnCommand Unified Manager 7.2 Installation and Setup Guide

OnCommand Unified Manager 7.2 Installation and Setup Guide OnCommand Unified Manager 7.2 Installation and Setup Guide April 2018 215-12015_C0 doccomments@netapp.com Table of Contents 3 Contents Introduction to OnCommand Unified Manager... 5 What the Unified Manager

More information

OnCommand Unified Manager 7.3 Installation and Setup Guide

OnCommand Unified Manager 7.3 Installation and Setup Guide OnCommand Unified Manager 7.3 Installation and Setup Guide November 2017 215-12452_A0 doccomments@netapp.com Table of Contents 3 Contents Introduction to OnCommand Unified Manager... 5 What the Unified

More information

OnCommand Unified Manager 9.4 Installation and Setup Guide

OnCommand Unified Manager 9.4 Installation and Setup Guide OnCommand Unified Manager 9.4 Installation and Setup Guide May 2018 215-12992_A0 doccomments@netapp.com Table of Contents 3 Contents Introduction to OnCommand Unified Manager... 5 What the Unified Manager

More information

OnCommand Unified Manager 9.5 Installation Guide

OnCommand Unified Manager 9.5 Installation Guide OnCommand Unified Manager 9.5 Installation Guide November 2018 215-13538_A0 doccomments@netapp.com Table of Contents 3 Contents Introduction to OnCommand Unified Manager... 5 What the Unified Manager

More information

OnCommand Unified Manager 9.4 Workflow Guide for Managing Cluster Health

OnCommand Unified Manager 9.4 Workflow Guide for Managing Cluster Health OnCommand Unified Manager 9.4 Workflow Guide for Managing Cluster Health May 2018 215-12993_A0 doccomments@netapp.com Table of Contents 3 Contents Introduction to OnCommand Unified Manager health monitoring...

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

OnCommand Unified Manager 6.1

OnCommand Unified Manager 6.1 OnCommand Unified Manager 6.1 Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web:

More information

OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3

OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3 IBM System Storage N series OnCommand Unified Manager Installation and Setup Guide for Use with Core Package 5.2 and Host Package 1.3 GA32-1020-03 Table of Contents 3 Contents Preface... 10 Supported

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

7-Mode Transition Tool 2.2

7-Mode Transition Tool 2.2 7-Mode Transition Tool 2.2 Copy-Based Transition Guide For Transitioning to Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

OnCommand Unified Manager

OnCommand Unified Manager OnCommand Unified Manager Operations Manager Administration Guide For Use with Core Package 5.2.1 NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Storage Manager 2018 R1. Installation Guide

Storage Manager 2018 R1. Installation Guide Storage Manager 2018 R1 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

Copy-Based Transition Guide

Copy-Based Transition Guide 7-Mode Transition Tool 3.2 Copy-Based Transition Guide For Transitioning to ONTAP February 2017 215-11978-A0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-based transition

More information

Installing and Configuring VMware Identity Manager Connector (Windows) OCT 2018 VMware Identity Manager VMware Identity Manager 3.

Installing and Configuring VMware Identity Manager Connector (Windows) OCT 2018 VMware Identity Manager VMware Identity Manager 3. Installing and Configuring VMware Identity Manager Connector 2018.8.1.0 (Windows) OCT 2018 VMware Identity Manager VMware Identity Manager 3.3 You can find the most up-to-date technical documentation on

More information

NetApp Element Plug-in for vcenter Server User Guide

NetApp Element Plug-in for vcenter Server User Guide NetApp Element Plug-in for vcenter Server User Guide Version 4.2 November 2018 215-13259_A0 doccomments@netapp.com Table of Contents 3 Contents About this guide... 8 vcenter Plug-in overview... 9 Network

More information

VMware Identity Manager Connector Installation and Configuration (Legacy Mode)

VMware Identity Manager Connector Installation and Configuration (Legacy Mode) VMware Identity Manager Connector Installation and Configuration (Legacy Mode) VMware Identity Manager This document supports the version of each product listed and supports all subsequent versions until

More information

VMware AirWatch Content Gateway for Linux. VMware Workspace ONE UEM 1811 Unified Access Gateway

VMware AirWatch Content Gateway for Linux. VMware Workspace ONE UEM 1811 Unified Access Gateway VMware AirWatch Content Gateway for Linux VMware Workspace ONE UEM 1811 Unified Access Gateway You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

VMware vfabric Data Director Installation Guide

VMware vfabric Data Director Installation Guide VMware vfabric Data Director Installation Guide vfabric Data Director 2.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by

More information

OnCommand Unified Manager 7.2: Best Practices Guide

OnCommand Unified Manager 7.2: Best Practices Guide Technical Report OnCommand Unified : Best Practices Guide Dhiman Chakraborty August 2017 TR-4621 Version 1.0 Abstract NetApp OnCommand Unified is the most comprehensive product for managing and monitoring

More information

VMware Identity Manager Cloud Deployment. DEC 2017 VMware AirWatch 9.2 VMware Identity Manager

VMware Identity Manager Cloud Deployment. DEC 2017 VMware AirWatch 9.2 VMware Identity Manager VMware Identity Manager Cloud Deployment DEC 2017 VMware AirWatch 9.2 VMware Identity Manager You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

VMware Identity Manager Cloud Deployment. Modified on 01 OCT 2017 VMware Identity Manager

VMware Identity Manager Cloud Deployment. Modified on 01 OCT 2017 VMware Identity Manager VMware Identity Manager Cloud Deployment Modified on 01 OCT 2017 VMware Identity Manager You can find the most up-to-date technical documentation on the VMware Web site at: https://docs.vmware.com/ The

More information

OnCommand Workflow Automation 4.2 Installation and Setup Guide for Windows

OnCommand Workflow Automation 4.2 Installation and Setup Guide for Windows OnCommand Workflow Automation 4.2 Installation and Setup Guide for Windows February 2018 215-12608_B0 doccomments@netapp.com Table of Contents 3 Contents Overview of OnCommand Workflow Automation... 6

More information

Antivirus Solution Guide. NetApp Clustered Data ONTAP 8.2.1

Antivirus Solution Guide. NetApp Clustered Data ONTAP 8.2.1 Antivirus Solution Guide NetApp Clustered Data ONTAP 8.2.1 Contents Abstract... 4 Audience... 4 Purpose and Scope... 4 Introduction... 4 Antivirus Solution Architecture... 5 Components of the Vscan/AV

More information

Deploying VMware Identity Manager in the DMZ. JULY 2018 VMware Identity Manager 3.2

Deploying VMware Identity Manager in the DMZ. JULY 2018 VMware Identity Manager 3.2 Deploying VMware Identity Manager in the DMZ JULY 2018 VMware Identity Manager 3.2 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

Virtual Storage Console 6.1 for VMware vsphere

Virtual Storage Console 6.1 for VMware vsphere Virtual Storage Console 6.1 for VMware vsphere Installation and Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

OnCommand Unified Manager 6.1 Administration Guide

OnCommand Unified Manager 6.1 Administration Guide IBM System Storage N series OnCommand Unified Manager 6.1 Administration Guide SC27-6627-00 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information, help, and

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

SnapCenter Software 4.0 Installation and Setup Guide

SnapCenter Software 4.0 Installation and Setup Guide SnapCenter Software 4.0 Installation and Setup Guide March 2018 215-12926_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read the SnapCenter Installation and Setup Guide...

More information

VMware AirWatch Content Gateway Guide for Linux For Linux

VMware AirWatch Content Gateway Guide for Linux For Linux VMware AirWatch Content Gateway Guide for Linux For Linux Workspace ONE UEM v9.7 Have documentation feedback? Submit a Documentation Feedback support ticket using the Support Wizard on support.air-watch.com.

More information

Dell Storage Manager 2016 R3 Installation Guide

Dell Storage Manager 2016 R3 Installation Guide Dell Storage Manager 2016 R3 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either

More information

Deploying VMware Identity Manager in the DMZ. SEPT 2018 VMware Identity Manager 3.3

Deploying VMware Identity Manager in the DMZ. SEPT 2018 VMware Identity Manager 3.3 Deploying VMware Identity Manager in the DMZ SEPT 2018 VMware Identity Manager 3.3 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

VMware vrealize Log Insight Getting Started Guide

VMware vrealize Log Insight Getting Started Guide VMware vrealize Log Insight Getting Started Guide vrealize Log Insight 2.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Proofpoint Threat Response

Proofpoint Threat Response Proofpoint Threat Response Threat Response Auto Pull (TRAP) - Installation Guide Proofpoint, Inc. 892 Ross Drive Sunnyvale, CA 94089 United States Tel +1 408 517 4710 www.proofpoint.com Copyright Notice

More information

Installing and Configuring VMware Identity Manager. DEC 2017 VMware AirWatch 9.2 VMware Identity Manager 3.1

Installing and Configuring VMware Identity Manager. DEC 2017 VMware AirWatch 9.2 VMware Identity Manager 3.1 Installing and Configuring VMware Identity Manager DEC 2017 VMware AirWatch 9.2 VMware Identity Manager 3.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Cluster Management Workflows for OnCommand System Manager

Cluster Management Workflows for OnCommand System Manager ONTAP 9 Cluster Management Workflows for OnCommand System Manager June 2017 215-11440-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents OnCommand System Manager workflows...

More information

Installing and Configuring VMware Identity Manager. Modified on 14 DEC 2017 VMware Identity Manager 2.9.1

Installing and Configuring VMware Identity Manager. Modified on 14 DEC 2017 VMware Identity Manager 2.9.1 Installing and Configuring VMware Identity Manager Modified on 14 DEC 2017 VMware Identity Manager 2.9.1 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

SnapCenter Software 2.0 Installation and Setup Guide

SnapCenter Software 2.0 Installation and Setup Guide SnapCenter Software 2.0 Installation and Setup Guide July 2017 215-11357_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to read this information... 7 SnapCenter overview... 8

More information

Installing and Configuring VMware Identity Manager

Installing and Configuring VMware Identity Manager Installing and Configuring VMware Identity Manager VMware Identity Manager 2.7 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Snap Creator Framework 4.1

Snap Creator Framework 4.1 Snap Creator Framework 4.1 Installation Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com

More information

AppController :21:56 UTC Citrix Systems, Inc. All rights reserved. Terms of Use Trademarks Privacy Statement

AppController :21:56 UTC Citrix Systems, Inc. All rights reserved. Terms of Use Trademarks Privacy Statement AppController 2.6 2014-03-18 13:21:56 UTC 2014 Citrix Systems, Inc. All rights reserved. Terms of Use Trademarks Privacy Statement Contents AppController 2.6... 6 About This Release... 8 Getting Started...

More information

NetApp Snap Creator Framework Installation and Administration Guide

NetApp Snap Creator Framework Installation and Administration Guide NetApp Snap Creator Framework 4.0.0 Installation and Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

akkadian Global Directory 3.0 System Administration Guide

akkadian Global Directory 3.0 System Administration Guide akkadian Global Directory 3.0 System Administration Guide Updated July 19 th, 2016 Copyright and Trademarks: I. Copyright: This website and its content is copyright 2014 Akkadian Labs. All rights reserved.

More information

Installation and Setup Guide

Installation and Setup Guide SnapCenter Software 4.1 Installation and Setup Guide December 2018 215-13401_C0 doccomments@netapp.com Updated for 4.1.1 Table of Contents 3 Contents Deciding whether to read the SnapCenter installation

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For Custom Plug-ins March 2018 215-12932_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding on whether to read the SnapCenter Data Protection

More information

OpenManage Integration for VMware vcenter Quick Install Guide for vsphere Client, Version 2.3.1

OpenManage Integration for VMware vcenter Quick Install Guide for vsphere Client, Version 2.3.1 OpenManage Integration for VMware vcenter Quick Install Guide for vsphere Client, Version 2.3.1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use

More information

iscsi Configuration for ESXi using VSC Express Guide

iscsi Configuration for ESXi using VSC Express Guide ONTAP 9 iscsi Configuration for ESXi using VSC Express Guide May 2018 215-11181_E0 doccomments@netapp.com Updated for ONTAP 9.4 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

Quick Installation Guide

Quick Installation Guide Nortel IP Flow Manager Release: 2.0 Version: 02.01 Copyright 2009 Nortel Networks Nortel IP Flow Manager 2.0 Page 1 of 9 Nortel IP Flow Manager Release: 2.0 Publication: NN48015-300 Document status: Standard

More information

VMware AirWatch Content Gateway Guide for Linux For Linux. AirWatch v9.3

VMware AirWatch Content Gateway Guide for Linux For Linux. AirWatch v9.3 VMware AirWatch Content Gateway Guide for Linux For Linux AirWatch v9.3 H a v e d o c u m e n t a t io n f e e d b a c k? S u b m it a D o c u m e n t a t io n F e e d b a c k s u p p o r t t ic k e t

More information

vrealize Suite Lifecycle Manager 1.0 Installation and Management vrealize Suite 2017

vrealize Suite Lifecycle Manager 1.0 Installation and Management vrealize Suite 2017 vrealize Suite Lifecycle Manager 1.0 Installation and Management vrealize Suite 2017 vrealize Suite Lifecycle Manager 1.0 Installation and Management You can find the most up-to-date technical documentation

More information

VMware AirWatch Content Gateway Guide For Linux

VMware AirWatch Content Gateway Guide For Linux VMware AirWatch Content Gateway Guide For Linux AirWatch v9.2 Have documentation feedback? Submit a Documentation Feedback support ticket using the Support Wizard on support.air-watch.com. This product

More information

VMware vfabric Data Director Installation Guide

VMware vfabric Data Director Installation Guide VMware vfabric Data Director Installation Guide vfabric Data Director 1.0.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Dell SupportAssist Version 1.3 for Servers Release Notes

Dell SupportAssist Version 1.3 for Servers Release Notes Dell SupportAssist Version 1.3 for Servers Release Notes This document describes the new features, enhancements, and known issues in Dell SupportAssist Version 1.3 for Servers Release type and definition

More information

Snap Creator Framework 4.1.2

Snap Creator Framework 4.1.2 Snap Creator Framework 4.1.2 Installation Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com

More information

Volume Disaster Recovery Preparation Express Guide

Volume Disaster Recovery Preparation Express Guide ONTAP 9 Volume Disaster Recovery Preparation Express Guide August 2018 215-11187_F0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster recovery

More information

Threat Response Auto Pull (TRAP) - Installation Guide

Threat Response Auto Pull (TRAP) - Installation Guide Threat Response Auto Pull (TRAP) - Installation Guide Installation guide provides information on how to get Threat Response Auto Pull (TRAP) [/trapguides/trap-about/] up and running in your environment.

More information

NFS Client Configuration with VAAI for ESX Express Guide

NFS Client Configuration with VAAI for ESX Express Guide ONTAP 9 NFS Client Configuration with VAAI for ESX Express Guide February 2018 215-11184_F0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide...

More information

Getting Started with ESXi Embedded

Getting Started with ESXi Embedded ESXi 4.0 Embedded vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

Data Fabric Solution for Cloud Backup Workflow Guide

Data Fabric Solution for Cloud Backup Workflow Guide Data Fabric Solutions Data Fabric Solution for Cloud Backup Workflow Guide Using ONTAP, SnapCenter, and AltaVault June 2017 215-11811_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether

More information

Antivirus Solution Guide for Clustered Data ONTAP: Symantec

Antivirus Solution Guide for Clustered Data ONTAP: Symantec Technical Report Antivirus Solution Guide for Clustered Data ONTAP: Symantec Saurabh Singh and Brahmanna Chowdary Kodavali, NetApp July 2016 TR-4304 Abstract An antivirus solution is key for enterprises

More information

CA Agile Central Installation Guide On-Premises release

CA Agile Central Installation Guide On-Premises release CA Agile Central Installation Guide On-Premises release 2016.2 Agile Central to Go 2017.1 rallysupport@rallydev.com www.rallydev.com 2017 CA Technologies (c) 2017 CA Technologies Version 2016.2 (c) Table

More information

Installing and Configuring VMware Identity Manager for Linux. Modified MAY 2018 VMware Identity Manager 3.2

Installing and Configuring VMware Identity Manager for Linux. Modified MAY 2018 VMware Identity Manager 3.2 Installing and Configuring VMware Identity Manager for Linux Modified MAY 2018 VMware Identity Manager 3.2 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

vrealize Suite Lifecycle Manager 1.1 Installation, Upgrade, and Management vrealize Suite 2017

vrealize Suite Lifecycle Manager 1.1 Installation, Upgrade, and Management vrealize Suite 2017 vrealize Suite Lifecycle Manager 1.1 Installation, Upgrade, and Management vrealize Suite 2017 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/

More information

Installation and User Guide

Installation and User Guide OnCommand Cloud Manager 3.0 Installation and User Guide For Volume Management September 2016 215-11109_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Product

More information

Installing and Configuring VMware vcenter Orchestrator

Installing and Configuring VMware vcenter Orchestrator Installing and Configuring VMware vcenter Orchestrator vcenter Orchestrator 5.5.2 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Installing Cisco CMX in a VMware Virtual Machine

Installing Cisco CMX in a VMware Virtual Machine Installing Cisco CMX in a VMware Virtual Machine This chapter describes how to install and deploy a Cisco Mobility Services Engine (CMX) virtual appliance. Cisco CMX is a prebuilt software solution that

More information

Administering vrealize Log Insight. September 20, 2018 vrealize Log Insight 4.7

Administering vrealize Log Insight. September 20, 2018 vrealize Log Insight 4.7 Administering vrealize Log Insight September 20, 2018 4.7 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this documentation,

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Deployment and Setup Guide for 7.1 release February 2018 215-12647_B0 doccomments@netapp.com Table of Contents

More information

Cluster Management Workflows for OnCommand System Manager

Cluster Management Workflows for OnCommand System Manager ONTAP 9 Cluster Management Workflows for OnCommand System Manager August 2018 215-12669_C0 doccomments@netapp.com Table of Contents 3 Contents OnCommand System Manager workflows... 5 Setting up a cluster

More information

Dell SupportAssist Version 1.2 for Servers User s Guide

Dell SupportAssist Version 1.2 for Servers User s Guide Dell SupportAssist Version 1.2 for Servers User s Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Ensure that the server where you install the Primary Server software meets the following requirements: Item Requirements Additional Details

Ensure that the server where you install the Primary Server software meets the following requirements: Item Requirements Additional Details ZENworks 11 SP4 System July 2015 The following sections provide the Novell ZENworks 11 SP4 requirements for hardware and software: Section 1, Primary Server, on page 1 Section 2, Managed Device, on page

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

StreamSets Control Hub Installation Guide

StreamSets Control Hub Installation Guide StreamSets Control Hub Installation Guide Version 3.2.1 2018, StreamSets, Inc. All rights reserved. Table of Contents 2 Table of Contents Chapter 1: What's New...1 What's New in 3.2.1... 2 What's New in

More information

Installing and Configuring VMware vrealize Orchestrator

Installing and Configuring VMware vrealize Orchestrator Installing and Configuring VMware vrealize Orchestrator vrealize Orchestrator 7.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Cluster Management Workflows for OnCommand System Manager

Cluster Management Workflows for OnCommand System Manager Clustered Data ONTAP 8.3 Cluster Management Workflows for OnCommand System Manager February 2016 215-10887_A0 doccomments@netapp.com Updated for 8.3.2 Table of Contents 3 Contents Contents of the Workflow

More information

Building Automation and Orchestration for Software-Defined Storage with NetApp and VMware

Building Automation and Orchestration for Software-Defined Storage with NetApp and VMware Technical Report Building Automation and Orchestration for Software-Defined Storage with NetApp and VMware Using NetApp OnCommand Workflow Automation, VMware vrealize Automation, and vrealize Orchestration

More information

Installing vrealize Network Insight

Installing vrealize Network Insight vrealize Network Insight 3.4 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

Version Installation Guide. 1 Bocada Installation Guide

Version Installation Guide. 1 Bocada Installation Guide Version 19.4 Installation Guide 1 Bocada Installation Guide Copyright 2019 Bocada LLC. All Rights Reserved. Bocada and BackupReport are registered trademarks of Bocada LLC. Vision, Prism, vpconnect, and

More information

Amigopod Release Notes. Updating to Amigopod Document Overview. Overview of the Update Process. Verify the System s Memory Limit

Amigopod Release Notes. Updating to Amigopod Document Overview. Overview of the Update Process. Verify the System s Memory Limit Amigopod 3.5.4 Release Notes This document contains release information for version 3.5.4 of the Aruba Amigopod visitor management appliance. Document Overview This document is organized into the following

More information

PRODUCT DOCUMENTATION. Backup & Replication v5.0. User Guide.

PRODUCT DOCUMENTATION. Backup & Replication v5.0. User Guide. PRODUCT DOCUMENTATION User Guide Backup & Replication v5.0 www.nakivo.com Table of Contents Solution Architecture... 4 Deployment...11 System Requirements... 12 Deployment Scenarios... 15 Installing NAKIVO

More information

SnapCenter Software 4.0 Concepts Guide

SnapCenter Software 4.0 Concepts Guide SnapCenter Software 4.0 Concepts Guide May 2018 215-12925_D0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use the Concepts Guide... 7 SnapCenter overview... 8 SnapCenter architecture...

More information

Red Hat Gluster Storage 3.3

Red Hat Gluster Storage 3.3 Red Hat Gluster Storage 3.3 Quick Start Guide Getting Started with Web Administration Last Updated: 2017-12-15 Red Hat Gluster Storage 3.3 Quick Start Guide Getting Started with Web Administration Rakesh

More information

The Cisco HCM-F Administrative Interface

The Cisco HCM-F Administrative Interface CHAPTER 5 This chapter contains information on the following topics: Overview of Cisco HCM-F Administrative Interface, page 5-1 Browser Support, page 5-2 Login and Logout, page 5-4 Online Help, page 5-5

More information

Installing or Upgrading ANM Virtual Appliance

Installing or Upgrading ANM Virtual Appliance CHAPTER 2 This chapter describes how to deploy Cisco ANM Virtual Appliance 4.3 (new installation) and how to upgrade from ANM software version 4.1 or 4.2 to software version 4.3. This chapter includes

More information

OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.2

OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.2 OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.2 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better

More information

Dell EMC ME4 Series vsphere Client Plug-in

Dell EMC ME4 Series vsphere Client Plug-in Dell EMC ME4 Series vsphere Client Plug-in User's Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Installing and Configuring VMware vcenter Orchestrator. vrealize Orchestrator 5.5.2

Installing and Configuring VMware vcenter Orchestrator. vrealize Orchestrator 5.5.2 Installing and Configuring VMware vcenter Orchestrator vrealize Orchestrator 5.5.2 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have

More information

System Requirements. System Requirements for Cisco DCNM, Release 10, page 1 Deployment Best Practices for Cisco DCNM, Release 10.

System Requirements. System Requirements for Cisco DCNM, Release 10, page 1 Deployment Best Practices for Cisco DCNM, Release 10. This chapter lists the tested and supported hardware and software specifications for Cisco Prime Data Center Network Management (DCNM) server and client architecture. The application has been tested in

More information

Installing and Configuring VMware vrealize Orchestrator

Installing and Configuring VMware vrealize Orchestrator Installing and Configuring VMware vrealize Orchestrator vrealize Orchestrator 6.0.1 This document supports the version of each product listed and supports all subsequent versions until the document is

More information

CA Agile Central Administrator Guide. CA Agile Central On-Premises

CA Agile Central Administrator Guide. CA Agile Central On-Premises CA Agile Central Administrator Guide CA Agile Central On-Premises 2018.1 Table of Contents Overview... 3 Server Requirements...3 Browser Requirements...3 Access Help and WSAPI...4 Time Zone...5 Architectural

More information

7-Mode Transition Tool 2.1

7-Mode Transition Tool 2.1 7-Mode Transition Tool 2.1 Data and Configuration Transition Guide For Transitioning to Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax:

More information

QUICK INSTALLATION GUIDE Minder 4.2

QUICK INSTALLATION GUIDE Minder 4.2 QUICK INSTALLATION GUIDE Minder 4.2 1 Minder 4.2 Contents 1. Introducing MindArray Minder... 4 1.1 Gain Visibility into Server, Application, Virtualization and Network Infrastructure... 4 1.2. Why Minder?...

More information

WatchGuard Dimension v2.0 Update 2 Release Notes. Introducing New Dimension Command. Build Number Revision Date 13 August 2015

WatchGuard Dimension v2.0 Update 2 Release Notes. Introducing New Dimension Command. Build Number Revision Date 13 August 2015 WatchGuard Dimension v2.0 Update 2 Release Notes Build Number 483146 Revision Date 13 August 2015 On 13 August 2015, WatchGuard released Dimension v2.0 Update 2. This update resolves an issue that caused

More information

OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.1

OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.1 OpenManage Integration for VMware vcenter Quick Installation Guide for vsphere Web Client Version 3.1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

UDP Director Virtual Edition Installation and Configuration Guide (for Stealthwatch System v6.9.0)

UDP Director Virtual Edition Installation and Configuration Guide (for Stealthwatch System v6.9.0) UDP Director Virtual Edition Installation and Configuration Guide (for Stealthwatch System v6.9.0) Installation and Configuration Guide: UDP Director VE v6.9.0 2016 Cisco Systems, Inc. All rights reserved.

More information

Administering vrealize Log Insight. 05-SEP-2017 vrealize Log Insight 4.3

Administering vrealize Log Insight. 05-SEP-2017 vrealize Log Insight 4.3 Administering vrealize Log Insight 05-SEP-2017 4.3 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If you have comments about this documentation,

More information

Copy-Free Transition Guide

Copy-Free Transition Guide 7-Mode Transition Tool 3.0 Copy-Free Transition Guide For Transitioning to ONTAP September 2016 215-11373_B0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-free transition

More information

vcenter Chargeback Manager Installation and Upgrade Guide

vcenter Chargeback Manager Installation and Upgrade Guide vcenter Chargeback Manager Installation and Upgrade Guide vcenter Chargeback Manager 2.6.0 This document supports the version of each product listed and supports all subsequent versions until the document

More information

VMWARE HORIZON CLOUD WITH VMWARE IDENTITY MANAGER QUICK START GUIDE WHITE PAPER MARCH 2018

VMWARE HORIZON CLOUD WITH VMWARE IDENTITY MANAGER QUICK START GUIDE WHITE PAPER MARCH 2018 VMWARE HORIZON CLOUD WITH VMWARE IDENTITY MANAGER QUICK START GUIDE WHITE PAPER MARCH 2018 Table of Contents Introduction to Horizon Cloud with Manager.... 3 Benefits of Integration.... 3 Single Sign-On....3

More information

VMware Skyline Collector Installation and Configuration Guide. VMware Skyline Collector 2.0

VMware Skyline Collector Installation and Configuration Guide. VMware Skyline Collector 2.0 VMware Skyline Collector Installation and Configuration Guide VMware Skyline Collector 2.0 You can find the most up-to-date technical documentation on the VMware website at: https://docs.vmware.com/ If

More information