LabVIEW DataFinder Toolkit

Size: px
Start display at page:

Download "LabVIEW DataFinder Toolkit"

Transcription

1 LabVIEW DataFinder Toolkit LabVIEW DataFinder Toolkit June A-01

2 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters North Mopac Expressway Austin, Texas USA Tel: Worldwide Offices Australia , Austria , Belgium 32 (0) , Brazil , Canada , China , Czech Republic , Denmark , Finland 358 (0) , France , Germany , India , Israel , Italy , Japan , Korea , Lebanon 961 (0) , Malaysia , Mexico , Netherlands 31 (0) , New Zealand , Norway 47 (0) , Poland , Portugal , Russia , Singapore , Slovenia , South Africa , Spain , Sweden 46 (0) , Switzerland , Taiwan , Thailand , Turkey , United Kingdom 44 (0) For further support information, refer to the Technical Support and Professional Services appendix. To comment on National Instruments documentation, refer to the National Instruments Web site at ni.com/info and enter the info code feedback National Instruments Corporation. All rights reserved.

3 Important Information Warranty The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free. A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty. National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it. EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMER S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owner s failure to follow the National Instruments installation, operation, or maintenance instructions; owner s modification of the product; owner s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control. Copyright Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation. The DataFinder component in this product includes CLucene software which use is governed by the Apache License, Version 2.0. This software includes Stingray software developed by the Rogue Wave Software division of Quovadx, Inc. Copyright , Quovadx, Inc. All rights reserved. For components used in USI (Xerces C++, ICU, HDF5, b64 library, Stingray, and STLport), the following copyright stipulations apply. For a listing of the conditions and disclaimers, refer to the USICopyrights.chm. Xerces C++. This product includes software developed by the Apache Software Foundation ( Copyright 1999 The Apache Software Foundation. All rights reserved. ICU. Copyright International Business Machines Corporation and others. All rights reserved. HDF5. NCSA HDF5 (Hierarchical Data Format 5) Software Library and Utilities Copyright 1998, 1999, 2000, 2001, 2003, by the Board of Trustees of the University of Illinois. All rights reserved. b64 library. Copyright (c) , Matthew Wilson and Synesis Software. All Rights Reserved. Stingray. This software includes Stingray software developed by the Rogue Wave Software division of Quovadx, Inc. Copyright , Quovadx, Inc. All Rights Reserved. STLport. Copyright Boris Fomitchev. National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction. Trademarks National Instruments, NI, ni.com, LabVIEW, and DIAdem are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency, partnership, or joint-venture relationship with National Instruments. Patents For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.

4 WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS (1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT INJURY TO A HUMAN. (2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER COLLECTIVELY TERMED SYSTEM FAILURES ). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

5 Contents About This Manual Conventions...vii Related Documentation...viii Chapter 1 Introduction DataFinder Desktop DataFinder and Remote DataFinder Configuring DataFinder Text Search and Extended Query Evaluating Search Results The DataFinder Toolkit Palette Chapter 2 Running a Search Running a Text Search Executing an Extended Query Displaying the Search Results as Waveforms Displaying Property Values Chapter 3 Connecting Other LabVIEW Components Processing a Text Search with the TDM Streaming VIs Processing Results of a Text Search with the Read From Measurement File Express VI Processing Results of an Extended Query with the Storage VIs Appendix A Technical Support and Professional Services Index National Instruments Corporation v LabVIEW DataFinder Toolkit

6 About This Manual Conventions You can use this manual to familiarize yourself with the NI LabVIEW DataFinder Toolkit features and how to use them. The first chapter describes what DataFinder is and what DataFinder is used for. You learn how to configure DataFinder and when to run a text search or execute an extended query. The chapter also describes the functionality of each of the VIs in the Toolkit Palette. The second chapter describes step by step how to run text searches and execute extended queries and how to evaluate and to graphically display search results. The third chapter describes how to use the LabVIEW DataFinder Toolkit in combination with other LabVIEW VIs. The following conventions are used in this manual: <> Angles brackets indicate a key you press to perform a function, for example, <Ctrl> for the control key.» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence Settings»Global Options»DataPlugins instructs you to open the Settings menu, select the Global Options item, and then select the DataPlugins item. This icon denotes a note, which alerts you to important information. bold italic monospace Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Parameters are also bolded. Italic text denotes a cross-reference. Text in this font denotes text or characters that you enter from the keyboard, such as dialog box entries and filenames. This font is also used for the names of drives, paths, folders, filenames, and filename extensions. National Instruments Corporation vii LabVIEW DataFinder Toolkit

7 About This Manual Related Documentation For more detailed information on the NI LabVIEW DataFinder Toolkit, refer to the following documentation: NI LabVIEW DataFinder Toolkit Help files, which you open by selecting Help»Search the LabVIEW Help and navigating to Toolkits»DataFinder in the Help tree, or by pressing <F1> in a Toolkit dialog box. NI DataFinder Server Edition: Search Engine for Technical Data A DataFinder server is a search engine that you install on a server. The DataFinder server browses specified folders on computers in a network for files that contain technical data. The DataFinder server indexes data files to provide the clients with the data properties. The DataFinder server indexes files for which DataPlugins are registered in the Server Manager. You can define several DataFinder servers in the Server Manager to provide different data for different work groups. Clients, such as LabVIEW and DIAdem, communicate with the DataFinder servers to query the indexed data and to load search results. LabVIEW DataFinder Toolkit viii ni.com

8 Introduction 1 Use the NI LabVIEW DataFinder Toolkit to work with DataFinder in LabVIEW. You can use DataFinder to search for simple texts or to execute extended queries for specific data properties, in indexed data. You can use the DataFinder Toolkit VIs to create query conditions using the logical operators AND and OR, and to access the mass data and properties of the search results. DataFinder DataFinder is a search engine you can use to find specific data in large amounts of various file formats, similar to Internet search engines. DataFinder searches for files in the search areas you specify. Search areas are file system folders that are on your local computer or on network drives. DataPlugins enable the DataFinder to index many different file formats and to search these files. All file formats indexed by DataFinder apply to the TDM data model and contain descriptive information on three different levels root, group, and channel. The TDM root object, also referred to as a file, can contain several groups, and each group can contain several channels. You can work with the TDM data model-defined set of properties at each of the three levels or insert your own custom properties. Desktop DataFinder and Remote DataFinder You can search for data using the Desktop DataFinder My DataFinder or a remote DataFinder. Use My DataFinder to run a search on your computer or on the network. You specify which search areas My DataFinder uses in a search. You cannot delete My DataFinder and you cannot create an additional Desktop DataFinder. You cannot access My DataFinder from remote computers. The DataFinder index is on your computer. In addition to My DataFinder you can use any number of remote DataFinders on your network. A remote DataFinder is a DataFinder from the NI DataFinder Server Edition and usually runs on a different computer. National Instruments Corporation 1-1 LabVIEW DataFinder Toolkit

9 Chapter 1 Introduction Configuring DataFinder Text Search and Extended Query The remote DataFinder contains the information for the connection to the other computer. NI DataFinder Server Edition enables you to configure a DataFinder and to make this DataFinder available to multiple clients on the network. In the DataFinder Server Edition configuration you can assign access rights to search areas for the individual clients. You can configure My DataFinder interactively. To do so, right-click the My DataFinder tray icon on the task bar and select Configure from the context menu. DataFinder then opens a configuration dialog box. On the Search Areas tab in the configuration dialog box you specify the search areas where My DataFinder searches for data files. For DataFinder to search for data in these search areas, the indexer must first index this data. You configure the indexing settings on the Indexer tab. You specify, for example, when files are indexed and the timeout for indexing a file. Click the DataPlugins tab of the configuration dialog box to specify which filename extensions DataFinder recognizes when searching for data. You can import and export the DataFinder configuration. To do so, click Import or Export in the DataFinder configuration dialog box. You can also configure DataFinder programmatically with the VIs Invoke Node and Property Node from the DataFinder API, which is in the DataFinder Toolkit palette. DataFinder offers you two different search functions: a basic text search and an extended query. The text search browses for the value you specify, in all the string properties of the files, groups, or channels in the search areas. You use the text search if you only have parts of the information you are searching for, or if you do not know whether the information you are searching for is stored on the file, group, or channel level. Use the Search Text VI for a text search. The extended query searches for specific values of properties stored on the file, group, or channel level. You use the extended query if you want to search for specific files, groups, or channels. You can, for example, use the serial number, the test specification, and the test status to find all the tests that have been executed for a specific unit under test. You use the Create Query VI to generate the query conditions for an extended query. To execute the search, wire the query output of Create Query VI to the Execute Query VI. LabVIEW DataFinder Toolkit 1-2 ni.com

10 Chapter 1 Introduction Evaluating Search Results In the extended query, you can use the Merge Queries VI to combine query conditions with the logical operators AND and OR. If you execute a search with the VIs Search Text or Create Query and Execute Query, you can then evaluate the returned results. The Results To Waveforms VI extracts the signals from the search results returned by the VIs Search Text and Execute Query, which allows you to, for example, graphically display the signals. The Get Property Values VI extracts values of one or more properties of the returned results. The DataFinder Toolkit Palette To open the DataFinder Toolkit palette, right-click the block diagram and select Connectivity»DataFinder Toolkit. The DataFinder Toolkit palette contains the following VIs: Search Text: Searches for text. Use the text search if you only have parts of the information you are searching for, or if you do not know whether the information you are searching for is stored on the file, group, or channel level. Create Query: Generates a query condition. You can search for text, paths, numeric values, and time/date values. Use the Merge Queries VI to combine multiple query conditions with each other. Use the Execute Query VI to execute the query condition. Merge Queries: Combines multiple query conditions into one query condition with the logical operators AND or OR. Use the Create Query VI to define the query conditions. Execute Query: Executes a query. Use the VIs Create Query and Merge Queries to define the query conditions. ResultsToWaveform: Extracts the signals from the search results returned by the VIs Search Text and Execute Query, to, for example, graphically display these signals. Get Property Values: Extracts the values of one or more properties of the search result references returned by the VIs Search Text and Execute Query. National Instruments Corporation 1-3 LabVIEW DataFinder Toolkit

11 Chapter 1 Introduction Get Indexed Properties: Determines the list of all indexed properties you can use to execute a query. Open DataFinder: Connects a DataFinder. Close Reference: Closes a DataFinder connection, a reference to a query condition, or references to the search results. The following figure shows the VIs in relation to each other: Figure 1-1. VIs in Relation to Each Other LabVIEW DataFinder Toolkit 1-4 ni.com

12 Running a Search 2 You can use the DataFinder Toolkit VIs to execute text searches and extended queries. In the following you will learn how to create and run a text search and execute an extended query. Running a Text Search Use the Search Text VI to execute a text search. To execute a text search, complete the following steps: 1. Launch LabVIEW. 2. Select Blank VI. 3. Switch to the block diagram. 4. Right-click the block diagram and select Connectivity»DataFinder Toolkit to open the palette. 5. Pin the palette. 6. Click Search Text.vi in the DataFinder Toolkit palette and click to insert the VI in the block diagram. 7. Right-click the DataFinder reference terminal and select Create» Constant from the context menu. 8. Right-click the search text terminal and select Create»Control from the context menu. 9. Right-click the results elements terminal and select Create» Indicator from the context menu. Figure 2-1. Search Text VI with DataFinder Reference, Search Text and Results Elements National Instruments Corporation 2-1 LabVIEW DataFinder Toolkit

13 Chapter 2 Running a Search 10. Switch to the front panel. 11. Enter the text in the search text entry field. 12. Click the Run button. LabVIEW displays the search results in the results elements indicator. Executing an Extended Query Use the Execute Query VI to execute an extended query. To execute an extended query, complete the following steps: 1. Launch LabVIEW. 2. Select Blank VI. 3. Switch to the block diagram. 4. Click Create Query.vi in the DataFinder Toolkit palette and click to insert the VI in the block diagram. 5. Right-click the object type terminal and select Create»Constant from the context menu. 6. Select whether the DataFinder searches for the specified value in a channel, a channel group, or a file. 7. Right-click the property name terminal and select Create»Control from the context menu. 8. Right-click the value terminal and select Create»Control from the context menu. 9. Click Execute Query.vi in the DataFinder Toolkit palette and click to insert the VI in the block diagram. 10. Right-click the DataFinder reference terminal and select Create» Constant from the context menu. 11. In the block diagram, connect the query reference out output of the Create Query VI, to the query reference input of the Execute Query VI. Query reference is the reference to the query condition of a DataFinder search. 12. Right-click the results elements terminal and select Create» Indicator from the context menu. LabVIEW DataFinder Toolkit 2-2 ni.com

14 Chapter 2 Running a Search Figure 2-2. Create Query and Execute Query VIs 13. Switch to the front panel. 14. Enter in the property name input field, the name of the property you want to use within your search, for example, filename. 15. Enter the value that you want to search for in the value input field. 16. Click the Run button. LabVIEW displays the search results indicator. Displaying the Search Results as Waveforms To display the signals of a search, use the Results To Waveforms VI. This VI extracts the signals from the search results. To graphically display the search results of an extended query, complete the following steps: 1. Switch to the block diagram. 2. Click Results To Waveforms.vi in the DataFinder Toolkit palette and click to insert the VI in the block diagram. 3. In the block diagram, connect the result references out output of the Execute Query VI, to the result references input of the Results To Waveforms VI. 4. Right-click the signals out terminal and select Create»Graph Indicator from the context menu. Figure 2-3. Displaying the Search Results with the Results To Waveforms VI National Instruments Corporation 2-3 LabVIEW DataFinder Toolkit

15 Chapter 2 Running a Search 5. Switch to the front panel. 6. In the property name input field, enter the name of the property you want to use within your search, for example, description. 7. Enter the value that you want to search for in the value input field. 8. Click the Run button. LabVIEW displays the search results as waveforms. Figure 2-4. The Search Results as Waveforms Displaying Property Values Use the Get Property Values VI to extract the values of specific properties of a search result. This VI extracts the values of one or more properties, from the result references returned by the VIs Search Text and Execute Query. To display specific properties of an extended query, complete the following steps: 1. Switch to the block diagram. 2. Delete the Results To Waveforms VI and the associated connections from the block diagram. 3. Click Get Property Values.vi in the DataFinder Toolkit palette and click to insert the VI in the block diagram. LabVIEW DataFinder Toolkit 2-4 ni.com

16 Chapter 2 Running a Search 4. In the block diagram, connect the result references out output of the Execute Query VI, to the result references input of the Get Property Values VI. 5. Right-click the property input of the Get Property Values VI and select Create»Control. 6. Right-click the property values output of the Get Property Values VI and select Create»Indicator. 7. Switch to the front panel. 8. In the property name input field, enter the name of a property, for example, description. 9. Click the Run button. LabVIEW now displays the values in the property values indicator. Figure 2-5. Displaying Property Values National Instruments Corporation 2-5 LabVIEW DataFinder Toolkit

17 Connecting Other LabVIEW Components 3 You can use the DataFinder Toolkit VIs in combination with other LabVIEW VIs. In the following you will learn how to use the TDM Streaming VIs and the Read From Measurement File Express VI to process the results of a simple text search. Additionally you will learn how to use the Storage VIs to process the results of an extended query. Processing a Text Search with the TDM Streaming VIs Use the TDM Streaming VIs to read and write signals and properties of TDMS files. The following example executes an extended query for channel groups and loads the found channel groups. The returned TDMS full paths are passed to the TDMS Open VI to open the file. The returned channel group names are passed to the TDMS Read VI to extract the signals of the channels in the resulting channel groups. Then the signals are displayed as waveforms. Figure 3-1. Processing a Text Search with the TDM Streaming VIs National Instruments Corporation 3-1 LabVIEW DataFinder Toolkit

18 Chapter 3 Connecting Other LabVIEW Components Processing Results of a Text Search with the Read From Measurement File Express VI The Read from Measurement File Express VI is for reading data from text files with measurement values (*.lvm) or from binary files with measurement values (*.tdm and *.tdms). The following example first executes a simple text search. It uses the DataPlugin names to differentiate between LVM, TDM, or TDMS files and the full path to read the data with the Read From Measurement File Express VI. The example then displays the search results as waveforms. Figure 3-2. Processing Results of a Text Search with the Read From Measurement File Express VI LabVIEW DataFinder Toolkit 3-2 ni.com

19 Chapter 3 Connecting Other LabVIEW Components Processing Results of an Extended Query with the Storage VIs Use the Storage VIs to read and write signals and properties of TDM or TDMS files. The following example first uses the Create Query VI to generate an extended query. The Execute Query VI searches for channels of TDM or TDMS files and transfers the channel names, paths, DataPlugin names and channel group names to the Read Data VIs, which read out the signals. The example then displays the search results as waveforms. Figure 3-3. Processing Results of an Extended Query with the Storage VIs National Instruments Corporation 3-3 LabVIEW DataFinder Toolkit

20 Technical Support and Professional Services A Visit the following sections of the award-winning National Instruments Web site at ni.com for technical support and professional services: Support Technical support at ni.com/support includes the following resources: Self-Help Technical Resources For answers and solutions, visit ni.com/support for software drivers and updates, a searchable KnowledgeBase, product manuals, step-by-step troubleshooting wizards, thousands of example programs, tutorials, application notes, instrument drivers, and so on. Registered users also receive access to the NI Discussion Forums at ni.com/forums. NI Applications Engineers make sure every question submitted online receives an answer. Standard Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and for one-to-one technical support as well as exclusive access to on demand training modules via the Services Resource Center. NI offers complementary membership for a full year after purchase, after which you may renew to continue your benefits. For information about other technical support options in your area, visit ni.com/services, or contact your local office at ni.com/contact. If you searched ni.com and could not find the answers you need, contact your local office or NI corporate headquarters. Phone numbers for our worldwide offices are listed at the front of this manual. You also can visit the Worldwide Offices section of ni.com/niglobal to access the branch office Web sites, which provide up-to-date contact information, support phone numbers, addresses, and current events. National Instruments Corporation A-1 LabVIEW DataFinder Toolkit

21 Index C Close Reference VI, 1-3 Configuration DataFinder, 1-2 Connecting, 1-1 Create Query VI, 1-2, 2-2 D DataFinder Configuration, 1-2 DataPlugins, 1-1 Export, 1-2 Import, 1-2 Indexer, 1-1 Network, 1-1 Remote, 1-1 Search areas, 1-1 DataFinder Server Edition, 1-1 DataFinder Toolkit Overview, 1-1 Palette, 1-3 Desktop DataFinder, 1-1 documentation related documentation, viii E Execute Query VI, 1-2, 2-2 Extended query, 1-2 Execute, 2-2 G Get Indexed Properties VI, 1-3 Get Property Values VI, 1-3, 2-4 I Indexer, 1-2 Invoke Node, 1-2 K KnowledgeBase, A-1 L Logical operators, 1-2 M Merge Queries VI, 1-2 My DataFinder, 1-1 N NI support and services, A-1 O Open DataFinder VI, 1-3 Operators, 1-2 P Palette, 1-3 Properties Display values, 2-4 Property Node, 1-2 National Instruments Corporation S-1 LabVIEW DataFinder Toolkit

22 Index Q Query conditions Connectives, 1-2 R Read from Measurement File Express VI, 3-2 related documentation, viii Remote DataFinder, 1-1 Results To Waveforms VI, 1-3, 2-3 T TDM Streaming VIs, 3-1 Text search, 1-2 Run, 2-1 W Web resources, A-1 S Search results Display as waveforms, 1-3, 2-3 Evaluation, 1-3 Search Text VI, 1-2, 2-1 Storage VIs, 3-3 LabVIEW DataFinder Toolkit S-2 ni.com

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual

Sample. LabWindows TM /CVI TM Core 1 Exercises Manual LabWindows TM /CVI TM Core 1 Exercises Manual Course Software Version 2010 January 2011 Edition Part Number 325669A-01 LabWindows/CVI Core 1 Course Manual Copyright 1994 2011 National Instruments Corporation.

More information

Sample. LabWindows TM /CVI TM Core 1 Course Manual

Sample. LabWindows TM /CVI TM Core 1 Course Manual LabWindows TM /CVI TM Core 1 Course Manual Course Software Version 2010 January 2011 Edition Part Number 325668A-01 LabWindows/CVI Core 1 Course Manual Copyright 1994 2011 National Instruments Corporation.

More information

Sample. LabVIEW TM Core 1 Exercises. Course Software Version 2010 August 2010 Edition Part Number B-01. LabVIEW Core 1 Exercises

Sample. LabVIEW TM Core 1 Exercises. Course Software Version 2010 August 2010 Edition Part Number B-01. LabVIEW Core 1 Exercises LabVIEW TM Core 1 Exercises Course Software Version 2010 August 2010 Edition Part Number 325291B-01 LabVIEW Core 1 Exercises Copyright 1993 2010 National Instruments Corporation. All rights reserved. Under

More information

LabVIEW DataFinder Toolkit

LabVIEW DataFinder Toolkit LabVIEW DataFinder Toolkit Use the NI LabVIEW DataFinder Toolkit to work with the DataFinder in LabVIEW. You can use the DataFinder to search for simple texts or to execute extended queries for specific

More information

VI Logger. Getting Started with VI Logger. Getting Started with VI Logger. May 2003 Edition Part Number B-01

VI Logger. Getting Started with VI Logger. Getting Started with VI Logger. May 2003 Edition Part Number B-01 VI Logger Getting Started with VI Logger Getting Started with VI Logger May 2003 Edition Part Number 322821B-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate

More information

NI DataSocket Server Help

NI DataSocket Server Help NI DataSocket Server Help April 2003 Edition, Part Number 370716A-01 Use this help file as a reference for information about the DataSocket Server, DataSocket Server Manager, DataSocket Server Diagnostics

More information

Using Your NI Software for DOS or Windows 3 with Windows 95/98

Using Your NI Software for DOS or Windows 3 with Windows 95/98 Using Your NI-488.2 Software for DOS or Windows 3 with Windows 95/98 Using NI-488.2 with Windows 95/98 June 1998 Edition Part Number 321011C-01 Copyright 1995, 1998 National Instruments Corporation. All

More information

DIAdemTM. Getting Started with DIAdem. Getting Started with DIAdem. April E-01

DIAdemTM. Getting Started with DIAdem. Getting Started with DIAdem. April E-01 DIAdemTM Getting Started with DIAdem Getting Started with DIAdem April 2007 373422E-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500

More information

NI SignalExpressTM. Getting Started with NI SignalExpress Tektronix Edition. June B-01

NI SignalExpressTM. Getting Started with NI SignalExpress Tektronix Edition. June B-01 NI SignalExpressTM Getting Started with NI SignalExpress Tektronix Edition Getting Started with NI SignalExpress Tektronix Edition June 2006 374297B-01 Support Worldwide Technical Support and Product Information

More information

NI TestStandTM. Using LabVIEW. with TestStand. Using LabVIEW with TestStand. April B-01

NI TestStandTM. Using LabVIEW. with TestStand. Using LabVIEW with TestStand. April B-01 NI TestStandTM TM Using LabVIEW with TestStand Using LabVIEW with TestStand April 2007 373200B-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters

More information

NI SMB-2145/2146/2147/2148

NI SMB-2145/2146/2147/2148 USER GUIDE NI SMB-2145/2146/2147/2148 Shielded Signal Accessories for NI 5751/5752 Adapter Modules The NI SMB-2145/2146/2147/2148 (NI SMB-214x) devices are shielded signal accessories for NI FlexRIO digitizer

More information

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0 RELEASE NOTES LabVIEW DSP Module Version 1.0 Contents Introduction Introduction... 1 LabVIEW Embedded Edition... 2 System Requirements... 3 Installation... 3 DSP Module Documentation... 4 Where to Go for

More information

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices INSTALLATION GUIDE NI CB-7F-LP Connector Block for 7-Pin D-Sub Devices Introduction This installation guide describes how to install and connect signals to the NI CB-7F-LP connector block for use with

More information

INSTALLATION INSTRUCTIONS LFH160 Cable

INSTALLATION INSTRUCTIONS LFH160 Cable INSTALLATION INSTRUCTIONS LFH160 This guide describes how to connect and use the National Instruments LFH160 cable which has a maximum voltage rating of 100 VDC, CAT I. Use the LFH160 cable to connect

More information

Getting Results with the NI PXI-6585R

Getting Results with the NI PXI-6585R Getting Results with the NI PXI-6585R This document explains how to install and configure the National Instruments PXI-6585R, comprised of an NI FlexRIO FPGA module (NI PXI-79xxR) and an NI 6585 FlexRIO

More information

LabVIEW. Getting Started with LabVIEW. Getting Started with LabVIEW

LabVIEW. Getting Started with LabVIEW. Getting Started with LabVIEW Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices

More information

LabVIEW DSP Module Release and Upgrade Notes

LabVIEW DSP Module Release and Upgrade Notes LabVIEW DSP Module Release and Upgrade Notes Version 2.5 Contents Introduction... 2 System Requirements... 2 Installation... 3 Installing the Drivers... 3 Setting Up the Hardware... 3 Installing Third-Party

More information

TestStand. Using LabWindows /CVI with TestStand. Using LabWindows/CVI with TestStand. July 2003 Edition Part Number A-01

TestStand. Using LabWindows /CVI with TestStand. Using LabWindows/CVI with TestStand. July 2003 Edition Part Number A-01 TM TestStand TM Using LabWindows /CVI with TestStand TM Using LabWindows/CVI with TestStand July 2003 Edition Part Number 323201A-01 Support Worldwide Technical Support and Product Information ni.com National

More information

DIAdemTM. Data Mining, Analysis, and Report Generation. DIAdem: Data Mining, Analysis, and Report Generation

DIAdemTM. Data Mining, Analysis, and Report Generation. DIAdem: Data Mining, Analysis, and Report Generation DIAdemTM Data Mining, Analysis, and Report Generation DIAdem: Data Mining, Analysis, and Report Generation National Instruments Ireland Resources Limited April 2007 373082F-01 Support Worldwide Technical

More information

DIAdemTM. Data Mining, Analysis, and Report Generation. DIAdem: Data Mining, Analysis, and Report Generation

DIAdemTM. Data Mining, Analysis, and Report Generation. DIAdem: Data Mining, Analysis, and Report Generation DIAdemTM Data Mining, Analysis, and Report Generation DIAdem: Data Mining, Analysis, and Report Generation National Instruments Ireland Resources Limited December 2005 373082D-01 Support Support Worldwide

More information

Getting Started with R Series Multifunction RIO

Getting Started with R Series Multifunction RIO Getting Started with R Series Multifunction RIO This document explains how to install and configure National Instruments PCI/PXI-781xR, PCI/PXI-783xR, PCIe/PXI-784xR, and PCIe/PXI-785xR, referred to collectively

More information

Getting Started with R Series Intelligent DAQ

Getting Started with R Series Intelligent DAQ Getting Started with R Series Intelligent DAQ This document explains how to install and configure National Instruments PCI/PXI-781xR, PCI/PXI-783xR, PXI-784xR, and PXI-785xR (NI 78xxR) devices. This document

More information

Electronics WorkbenchTM

Electronics WorkbenchTM Electronics WorkbenchTM MultiVHDL 8 Programmable Logic User Guide TitleShort-Hidden (cross reference text) February 2006 371888A-01 Support Worldwide Technical Support and Product Information ni.com National

More information

NI 653x Cable Adapter

NI 653x Cable Adapter USER GUIDE NI 65x Cable Adapter Contents The NI 65x cable adapter interfaces with National Instruments high-speed digital I/O (DIO) devices. The cable adapter provides an easy way to connect the Very High

More information

NI 9213 Calibration Procedure

NI 9213 Calibration Procedure NI 9213 Calibration Procedure Français Deutsch ni.com/manuals This document contains information about calibrating National Instruments 9213 modules using NI-DAQmx. This calibration procedure is intended

More information

DIAdemTM. Data Acquisition. Getting Started and User Manual. DIAdem: Data Acquisition. National Instruments Ireland Resources Limited

DIAdemTM. Data Acquisition. Getting Started and User Manual. DIAdem: Data Acquisition. National Instruments Ireland Resources Limited DIAdemTM Data Acquisition Getting Started and User Manual DIAdem: Data Acquisition National Instruments Ireland Resources Limited December 2005 373078D-01 Support Worldwide Technical Support and Product

More information

PXI. NI-Sync User Manual. NI-Sync User Manual. October C-01

PXI. NI-Sync User Manual. NI-Sync User Manual. October C-01 PXI NI-Sync User Manual NI-Sync User Manual October 2005 370926C-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway

More information

DIAdem. Data Set Description. ni.com/diadem

DIAdem. Data Set Description. ni.com/diadem DIAdem Data Set Description ni.com/diadem DIAdem DIAdem Data Set Description Manual Februar 2002 Edition Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters

More information

Getting Results with the NI 5752R

Getting Results with the NI 5752R Getting Results with the NI 5752R This document explains how to install and configure an NI FlexRIO FPGA module (NI PXI/PXIe-79xxR) and an NI FlexRIO adapter module (NI 5752) to form the NI 5752R. This

More information

You need the following to set up and use your terminal block:

You need the following to set up and use your terminal block: INSTALLATION GUIDE NI TB-2706 PXI/PXIe Terminal Block for M Series and NI 6143 Devices Contents Introduction This installation guide describes how to install and connect signals to the NI TB-2706 terminal

More information

DIAdemTM. Getting Started with DIAdem. Getting Started with DIAdem. June J-01

DIAdemTM. Getting Started with DIAdem. Getting Started with DIAdem. June J-01 DIAdemTM Getting Started with DIAdem Getting Started with DIAdem June 2010 373422J-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500

More information

LabVIEW. PDA Module User Manual. PDA Module User Manual. April 2003 Edition Part Number A-01

LabVIEW. PDA Module User Manual. PDA Module User Manual. April 2003 Edition Part Number A-01 LabVIEW PDA Module User Manual TM PDA Module User Manual April 2003 Edition Part Number 370624A-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters

More information

NI MATRIXxTM. SystemBuild User Guide. State Transition Diagram Block. SystemBuild State Transition Diagram Block User Guide. April C-01

NI MATRIXxTM. SystemBuild User Guide. State Transition Diagram Block. SystemBuild State Transition Diagram Block User Guide. April C-01 NI MATRIXxTM TM SystemBuild User Guide State Transition Diagram Block SystemBuild State Transition Diagram Block User Guide April 2007 370766C-01 Support Worldwide Technical Support and Product Information

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E 4-Port, RS232 Serial Module This document describes how to use the National Instruments 9870E and includes dimensions, pin assignments, and specifications

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module This document describes how to use the National Instruments 9208E and includes dimensions, pin assignments,

More information

Test Executive Reference Manual

Test Executive Reference Manual Test Executive Reference Manual LabVIEW Test Executive Reference Manual May 1999 Edition Part Number 320599D-01 Worldwide Technical Support and Product Information www.natinst.com National Instruments

More information

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 "INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO,

NI SPEEDY-33. '7 NATIONAL INSTALLATIONGUIDE. P~ClCl J ~ Ig~~!1 INSTRUMENTSN. 1~~~~~~g~~lm.OOOQ{JOOO, INSTALLATIONGUIDE NI SPEEDY-33 P~ClCl J ~ This installation guide describes how to install and configure the NI SPEEDY-33DSP device for use with a Pc. Figure] depicts the NI SPEEDY-33. 0 ~~.O~~ ~ Ig~~!1

More information

DIAdemTM. Data Acquisition and Visualization. DIAdem: Data Acquisition and Visualization. National Instruments Ireland Resources Limited

DIAdemTM. Data Acquisition and Visualization. DIAdem: Data Acquisition and Visualization. National Instruments Ireland Resources Limited DIAdemTM Data Acquisition and Visualization DIAdem: Data Acquisition and Visualization National Instruments Ireland Resources Limited May 2008 374987A-01 Support Worldwide Technical Support and Product

More information

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment. INSTALLATION GUIDE NI VXIpc -882 This guide contains information about installing and troubleshooting your NI VXIpc-882 controller and components. This guide refers to the NI VXIpc-882 User Manual, which

More information

LabVIEW. Embedded Development Module Target Distribution Guide. Target Distribution Guide. July A-01

LabVIEW. Embedded Development Module Target Distribution Guide. Target Distribution Guide. July A-01 TM LabVIEW Embedded Development Module Target Distribution Guide Target Distribution Guide July 2006 371966A-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E 4-Port, RS485/RS422 Serial Module This document describes how to use the National Instruments 9871E and includes dimensions, pin assignments, and specifications

More information

Calibrating FieldPoint Analog Input Modules with Calibration Executive

Calibrating FieldPoint Analog Input Modules with Calibration Executive USER GUIDE Calibrating FieldPoint Analog Input Modules with Calibration Executive Contents This document contains step-by-step instructions for loading and running National Instruments Calibration Executive

More information

NI TestStandTM. Reference Manual. NI TestStand Reference Manual. April B-01

NI TestStandTM. Reference Manual. NI TestStand Reference Manual. April B-01 NI TestStandTM Reference Manual NI TestStand Reference Manual April 2007 373435B-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500

More information

LabVIEW. Getting Started with LabVIEW and Tektronix Open Windows Oscilloscopes. Getting Started with LabVIEW

LabVIEW. Getting Started with LabVIEW and Tektronix Open Windows Oscilloscopes. Getting Started with LabVIEW LabVIEW Getting Started with LabVIEW and Tektronix Open Windows Oscilloscopes TM Getting Started with LabVIEW August 2002 Edition Part Number 323387A-01 Support Worldwide Technical Support and Product

More information

NI TestStandTM. Reference Manual. NI TestStand Reference Manual. May C-01

NI TestStandTM. Reference Manual. NI TestStand Reference Manual. May C-01 NI TestStandTM Reference Manual NI TestStand Reference Manual May 2008 373435C-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North

More information

Fieldbus. NI-FBUS Monitor User Manual. NI-FBUS Monitor User Manual. June C-01

Fieldbus. NI-FBUS Monitor User Manual. NI-FBUS Monitor User Manual. June C-01 Fieldbus NI-FBUS Monitor User Manual NI-FBUS Monitor User Manual June 2010 371171C-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500

More information

NI 6521 Specifications

NI 6521 Specifications NI 6521 Specifications This document lists specifications for the NI 6521 device. All specifications are subject to change without notice. These specifications are typical at 25 C unless otherwise noted.

More information

NI OCR Training Interface Help

NI OCR Training Interface Help NI OCR Training Interface Help August 2008, 370643G-01 The NI OCR Training Interface Help contains information about how to use the OCR Training Interface to train characters, save character sets, and

More information

FieldPoint. Note to Users

FieldPoint. Note to Users FieldPoint FP-1000/1001 User Manual FP-1000/1001 User Manual Note to Users The contents of this document that refer to FieldPoint software are not intended for use with FieldPoint Software 4.0 or LabVIEW

More information

Sample. LabVIEW TM FPGA Course Manual. Course Software Version 2009 August 2009 Edition Part Number C-01 LabVIEW FPGA Course Manual

Sample. LabVIEW TM FPGA Course Manual. Course Software Version 2009 August 2009 Edition Part Number C-01 LabVIEW FPGA Course Manual LabVIEW TM FPGA Course Manual Course Software Version 2009 August 2009 Edition Part Number 372510C-01 LabVIEW FPGA Course Manual Copyright 2003 2009 National Instruments Corporation. All rights reserved.

More information

LabVIEW Datalogging and Supervisory Control Module Run-Time Manual

LabVIEW Datalogging and Supervisory Control Module Run-Time Manual LabVIEW Datalogging and Supervisory Control Module Run-Time Manual Datalogging & Supervisory Control Run-Time Manual October 2000 Edition Part Number 321635D-01 Support Worldwide Technical Support and

More information

Installing the GPIB-1014 and the NI-488M Software in Sun Workstations

Installing the GPIB-1014 and the NI-488M Software in Sun Workstations Installing the GPIB-1014 and the NI-488M Software in Sun Workstations June 1994 Edition Part Number 320065-01 Copyright 1985, 1994 National Instruments Corporation. All Rights Reserved. National Instruments

More information

LabWindows /CVI Test Executive Toolkit Reference Manual

LabWindows /CVI Test Executive Toolkit Reference Manual LabWindows /CVI Test Executive Toolkit Reference Manual November 1994 Edition Part Number 320863A-01 Copyright 1994 National Instruments Corporation. All rights reserved. National Instruments Corporate

More information

Using Measurement & Automation Explorer (MAX) with VXI

Using Measurement & Automation Explorer (MAX) with VXI Using Measurement & Automation Explorer (MAX) with VXI Introduction Measurement & Automation Explorer (MAX) provides access to all your National Instruments DAQ, GPIB, IMAQ, IVI, Motion, VISA, and VXI

More information

Sample. LabWindows TM /CVI TM Basics I Course Manual

Sample. LabWindows TM /CVI TM Basics I Course Manual LabWindows TM /CVI TM Basics I Course Manual Course Software Version 8.0 March 2006 Edition Part Number 320803J-01 LabWindows/CVI Basics I Course Manual Copyright 1994 2006 National Instruments Corporation.

More information

NI SD Card Memory Module

NI SD Card Memory Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9802 2 SD Card Memory Module Français Deutsch ni.com/manuals This document describes how to use the National Instruments 9802 and includes specifications for

More information

Safety. Introduction

Safety. Introduction KickStart Guide Safety Introduction Safety precautions Before using this product, see the safety precautions associated with your instrument. The instrumentation associated with this software is intended

More information

NI Vision. NI Vision Assistant Tutorial. NI Vision Assistant Tutorial. June M

NI Vision. NI Vision Assistant Tutorial. NI Vision Assistant Tutorial. June M NI Vision NI Vision Assistant Tutorial NI Vision Assistant Tutorial June 2011 372228M Support Worldwide Technical Support and Product Information ni.com Worldwide Offices Visit ni.com/niglobal to access

More information

Getting Started with NI-Motion for NI 73xx Motion Controllers

Getting Started with NI-Motion for NI 73xx Motion Controllers Getting Started with NI-Motion for NI 73xx Motion Controllers This document provides instructions for installing and getting started with the NI-Motion driver software and National Instruments PXI/PCI-73xx

More information

LabVIEW Datalogging and Supervisory Control Module Developer s Manual

LabVIEW Datalogging and Supervisory Control Module Developer s Manual LabVIEW Datalogging and Supervisory Control Module Developer s Manual Datalogging & Supervisory Control Developer s Manual October 2001 Edition Part Number 321294E-01 Support Worldwide Technical Support

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

ETConcept Systems Engineering. User s Guide

ETConcept Systems Engineering. User s Guide Wiegand to RS485 Converter User s Guide Nov-08 Copyright 2008. All rights reserved including the right of reproduction in whole or in part in any form. Contents List of Accessories Included... 1 List

More information

NI PCIe NI PCIe-6509 Register Level Programming Reference Manual. NI PCIe-6509 Reference Manual. January A-01

NI PCIe NI PCIe-6509 Register Level Programming Reference Manual. NI PCIe-6509 Reference Manual. January A-01 NI PCIe-6509 NI PCIe-6509 Register Level Programming Reference Manual NI PCIe-6509 Reference Manual January 2012 373665A-01 Support Worldwide Technical Support and Product Information ni.com Worldwide

More information

Measure Serial Control User Manual

Measure Serial Control User Manual Measure Serial Control User Manual August 1996 Edition Part Number 321005B-01 Copyright 1995,1996 National Instruments Corporation. All rights reserved. Internet Support Email: measure.support@natinst.com

More information

U85026A Detector 40 to 60 GHz

U85026A Detector 40 to 60 GHz Operating and Service Manual U85026A Detector 40 to 60 GHz Serial Numbers This manual applies directly to U85026A detectors with serial numbers 100 and above. For additional information on serial numbers,

More information

Sample. LabVIEW Basics II Development Course Manual

Sample. LabVIEW Basics II Development Course Manual LabVIEW Basics II Development Course Manual Course Software Version 8.0 May 2006 Edition Part Number 320629P-01 LabVIEW Development Course Manual Copyright 1993 2006 National Instruments Corporation. All

More information

SCXITM. SCXI-1125 User Manual. SCXI-1125 User Manual. October C-01

SCXITM. SCXI-1125 User Manual. SCXI-1125 User Manual. October C-01 SCXITM SCXI-1125 User Manual SCXI-1125 User Manual October 2009 372425C-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters 11500 North Mopac

More information

IMAQ. NI-IMAQ for IEEE-1394 Cameras User Manual. Image Acquisition Software. March 2001 Edition Part Number A-01

IMAQ. NI-IMAQ for IEEE-1394 Cameras User Manual. Image Acquisition Software. March 2001 Edition Part Number A-01 IMAQ NI-IMAQ for IEEE-1394 Cameras User Manual Image Acquisition Software NI-IMAQ for IEEE-1394 Cameras User Manual March 2001 Edition Part Number 370362A-01 Worldwide Technical Support and Product Information

More information

Installation Operation & Specifications Manual. General Description

Installation Operation & Specifications Manual. General Description 101-0020 USB to 2-Wire RS-485 Converter Installation Operation & Specifications Manual General Description The 101-0020 USB to RS-485 converter provides a simple, low cost interface between a PC or laptop

More information

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400 END-OF-LIFE NOTICE, NO. 2566 END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400 Cisco Systems announces the end of life of the Cisco Media Convergence Server 7845H-2400.

More information

LabVIEW TM Real-Time 2: Architecting Embedded Systems Exercises

LabVIEW TM Real-Time 2: Architecting Embedded Systems Exercises LabVIEW TM Real-Time 2: Architecting Embedded Systems Exercises Course Software Version 2012 November 2012 Edition Part Number 325585B-01 LabVIEW Real-Time 2 Exercises Copyright 2010 2012 National Instruments

More information

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE GETTING STARTED GUIDE NI-DAQ mx Base 1.x Contents This guide describes how to install and configure the NI-DAQmx Base 1.x software and a data acquisition (DAQ) device. This guide also describes how to

More information

Agilent IntuiLink for Infiniium Software for the Agilent Technologies Infiniium-Series Oscilloscopes. Getting Started With Agilent IntuiLink

Agilent IntuiLink for Infiniium Software for the Agilent Technologies Infiniium-Series Oscilloscopes. Getting Started With Agilent IntuiLink Agilent IntuiLink for Infiniium Software for the Agilent Technologies Infiniium-Series Oscilloscopes Getting Started With Agilent IntuiLink Warranty A copy of the specific warranty terms applicable to

More information

TestStand Evaluation Guide

TestStand Evaluation Guide TestStand Evaluation Guide TestStand Evaluation Guide January 2002 Edition Part Number 350863A-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters

More information

Programming Note. Agilent Technologies Quick Reference Guide For the 8757D/E Scalar Network Analyzer

Programming Note. Agilent Technologies Quick Reference Guide For the 8757D/E Scalar Network Analyzer Programming Note Agilent Technologies Quick Reference Guide For the 8757D/E Scalar Network Analyzer Manufacturing Part Number: 08757-90130 Printed in USA Print Date: July 1992 Agilent Technologies, Inc.

More information

NI DIAdemTM. Data Mining, Analysis, and Report Generation. NI DIAdem: Data Mining, Analysis, and Report Generation. July K-01

NI DIAdemTM. Data Mining, Analysis, and Report Generation. NI DIAdem: Data Mining, Analysis, and Report Generation. July K-01 NI DIAdemTM Data Mining, Analysis, and Report Generation NI DIAdem: Data Mining, Analysis, and Report Generation July 2012 323082K-01 Worldwide Technical Support and Product Information ni.com Worldwide

More information

TBX-96 TERMINAL BLOCK

TBX-96 TERMINAL BLOCK INSTALLATION GUIDE TBX-96 TERMINAL BLOCK This guide describes how to install and use the TBX-96 terminal block with the SCXI-1100, SCXI-1102B/C, SCXI-1104/C, and SCXI-1581 modules. The TBX-96 is a shielded,

More information

Measure GPIB User Manual

Measure GPIB User Manual Measure GPIB User Manual August 1996 Edition Part Number 321295A-01 Copyright 1995,1996 National Instruments Corporation. All rights reserved. Internet Support Email: measure.support@natinst.com National

More information

Getting Started with the NI LabVIEW Embedded Module for ADI Blackfin Processors Version 8.6

Getting Started with the NI LabVIEW Embedded Module for ADI Blackfin Processors Version 8.6 Getting Started with the NI LabVIEW Embedded Module for ADI Blackfin Processors Version 8.6 The NI LabVIEW Embedded Module for ADI Blackfin Processors is a comprehensive graphical development environment

More information

Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP

Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP Application Note Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP Introduction This is an application note for connectivity of Lucent/Avaya

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment.

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment. Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment. FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS

More information

I C/SPI. NI-845x Software User Manual. NI-845x Software User Manual. January B-01

I C/SPI. NI-845x Software User Manual. NI-845x Software User Manual. January B-01 2 I C/SPI NI-845x Software User Manual NI-845x Software User Manual January 2007 371746B-01 Support Worldwide Technical Support and Product Information ni.com National Instruments Corporate Headquarters

More information

Power Analyzer Firmware Update Utility Version Software Release Notes

Power Analyzer Firmware Update Utility Version Software Release Notes Power Analyzer Firmware Update Utility Version 3.1.0 Software Release Notes Contents General Information... 2... 2 Supported models... 2 Minimum system requirements... 2 Installation instructions... 2

More information

VME-GPIB Installation and User Guide

VME-GPIB Installation and User Guide VME-GPIB Installation and User Guide Contents Introduction Introduction... 1 What Your Kit Should Contain... 2 Optional Equipment and Software Packages... 3 Unpacking your VME-GPIB... 3 Functional Overview...

More information

Microsoft Dynamics 365 for Finance and Operations, Enterprise edition. Table of contents

Microsoft Dynamics 365 for Finance and Operations, Enterprise edition. Table of contents Microsoft Dynamics 365 for Finance and Operations, Enterprise edition Product availability, localization, and translation guide July 2017 Update 1 Dynamics 365 for Finance and Operations, Enterprise edition

More information

MicroLink Installation Operation & Specifications Manual. General Description

MicroLink Installation Operation & Specifications Manual. General Description TM MicroLink HART Protocol Modem - USB Interface 101-0007 Installation Operation & Specifications Manual General Description The MicroLink 101-0007 is a USB to HART device Interface. It provides the hardware

More information

InLinK HM Setup Software Installation & Operation Manual

InLinK HM Setup Software Installation & Operation Manual InLinK HM HART Protocol Modem Module with HART Device to Modbus Accumulator for OEM Applications 101-0014 Setup Software Installation & Operation Manual InLink-HM 101-0014 is a complete OEM HART protocol

More information

Agilent BenchLink XL Software for the Agilent Technologies Series Oscilloscopes. Getting Started With Agilent BenchLink XL

Agilent BenchLink XL Software for the Agilent Technologies Series Oscilloscopes. Getting Started With Agilent BenchLink XL Agilent BenchLink XL 54600 Software for the Agilent Technologies 54600-Series Oscilloscopes Getting Started With Agilent BenchLink XL Warranty A copy of the specific warranty terms applicable to your Agilent

More information

NI 6584R User Guide and Specifications

NI 6584R User Guide and Specifications NI 6584R User Guide and Specifications Contents The NI 6584 is an RS-485/422 adapter module designed to work in conjunction with your NI FlexRIO FPGA module. This document contains signal information and

More information

FieldPoint FP-1000/1001 User Manual

FieldPoint FP-1000/1001 User Manual FieldPoint FP-1000/1001 User Manual FieldPoint FP-1000/1001 User Manual August 1998 Edition Part Number 321631B-01 Copyright 1997, 1998 National Instruments Corporation. All rights reserved. Internet Support

More information

Measurement Studio LabWindows/CVI Instrument Driver Developers Guide

Measurement Studio LabWindows/CVI Instrument Driver Developers Guide Measurement Studio LabWindows/CVI Instrument Driver Developers Guide Instrument Driver Developers Guide July 2001 Edition Part Number 320684F-01 Support Worldwide Technical Support and Product Information

More information

Microsoft Dynamics 365 for Finance and Operations. Table of contents

Microsoft Dynamics 365 for Finance and Operations. Table of contents Microsoft Dynamics 365 for Finance and Operations Product localization and translation availability guide April 2018 update 1 Dynamics 365 for Finance and Operations Product localization and translation

More information

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up Quick Start Guide FieldPoint cfp-20xx What You Need to Get Set Up cfp-20xx LabVIEW RT controller Mounting hardware (DIN rail, panel-mount, or rack-mount accessory) I/O module(s) cfp-bp-x backplane, connector

More information

87421/22A Power Supply. Operating and Service Manual

87421/22A Power Supply. Operating and Service Manual 87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to

More information

NI CardBus-8310-to-PXI Expansion Kit

NI CardBus-8310-to-PXI Expansion Kit INSTALLATION GUIDE NI CardBus-8310-to-PXI Expansion Kit Before Installation This document provides instructions on the installation of the NI CardBus-8310-to-PXI Expansion Kit. Before installing the NI

More information

MATRIXx. Xmath Interactive Control Design Module. April 2004 Edition Part Number B-01

MATRIXx. Xmath Interactive Control Design Module. April 2004 Edition Part Number B-01 TM MATRIXx TM Xmath Interactive Control Design Module Xmath Interactive Control Design Module April 2004 Edition Part Number 370754B-01 Support Worldwide Technical Support and Product Information ni.com

More information

For NI PXI and NI SCXI Switch Modules

For NI PXI and NI SCXI Switch Modules GETTING STARTED GUIDE NI Switches For NI PXI and NI SCXI Switch Modules This document explains how to install, configure, and test a National Instruments PXI or SCXI switch module. This document contains

More information

Training Notes Unity Real Time 2

Training Notes Unity Real Time 2 Training Notes Unity Real Time 2 For Customers Using SPC (Westgard) Rules Log on to Unity Real Time 2 1 Double-click the Unity Real Time 2 shortcut located on your computer desktop. 2 Select your user

More information

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module FieldPoint Operating Instructions cfp-rly-421 Eight-Channel SPST Relay Module These operating instructions describe how to install and use the National Instruments cfp-rly-421 relay module, revision 185151C-01

More information