DGR360. Digital Gyro Repeater. Operating & Installation Manual

Similar documents
Autopilot Override NFU Tiller

Remote NFU Tiller. Type Operating instructions

General Override Signal Unit AS (Operator Unit General Override)

Take Over Operator Unit AS

Automatic Identification System AIS. Type RM 808 AIS. Short Operation Manual

Operator Unit. Type Description 2 Operation 3 Maintenance and repairs

Updating software in micro processors with internal Flash memory

AUTOPILOT NP 2025 PLUS

GDS101 Operation and Installation Manual

SINEC. Configuring the S7 Mode with COML S7. 1 Overview of S7 Communication. 2 The COML S7 Program. 3 Configuration. Volume 1 of 1.

Raytheon Anschütz GmbH Operator Manual

Modem for SITRANS TK 7NG3190-6KB C79000-B7174-C14 SIEMENS SITRANS TK COM 1 MODEM

Course to Steer Indicator (Operator Unit)

GDS101 Operation and Installation Manual

EML224 / DL1 Compact Speed Log System

SKIPPER DL Axis Doppler Log Operation And Installation Manual. Edition Csw3.26 Valid from SN: DOU-03137

Weatherdock AG. Sigmundstraße D Nürnberg Tel. : Fax:

SkyRAY Light. Installation Handbook

GV-EL124S Electric Strike

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

SINEC. CP 5431 FMS with COM 5431 FMS. 1 Introduction C79000-B8976-C062/02. 2 Basics of the PROFIBUS B Index 3 Selecting the Type of

SIMATIC NET. AS-Interface Master Module CP Introduction. 2 Technical Description and Installation Guidelines for the CP 242-2

Slimline CW & WW Series

SBPDIS2Axx. Dupline Carpark Display. Benefits. Description

RGB Power Batten. User Manual. Order code: EQLED032

UV Power Flood. User Manual. Order code: EQLED029

EY-SU 358: Push-button unit for room operating unit, ecounit358

PilotStar NX. Heading Control System

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

ML-20IP INNOVATION DIRECT. IP video door station. User manual. Thank you for the choice of our equipment. { Design. Uniqueness. Innovations } SERIES

4 Channel DMX Driver Instruction Manual

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

LED PAR56 Order Code: P56-151

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

DL850 (270 khz) Operation and Installation Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Manual. Simrad IS70/IS80 Rudder Indicators RI70 and RI80. English

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

NMEA Expander. Operation And. Installation Manual

UV Spectra Batten 12 x 5W UV LEDs

Vector Beam White. User Manual. Order code: LEDJ265

HuddleCamHD 3XA with Audio USB 2.0 PTZ Camera w/ built-in Mic Array Installation and Operation Manual

Installation Manual. Alpha 4000 RGB Signs. Before you begin

STS.01.A.0115FB. Spartan Iridium Transceiver Antenna System

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Avonic AV-CON300. PTZ Camera Controller

Velox. High-Speed Backplane Connectors for VPX

Order code: EQLED60 USER MANUAL

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Fusion Saber. User Manual. Order code: EQLED070

Network Camera. Quick Guide DC-T3243HRX. Powered by

VADDIO /CANON BU-SERIES PTZ CAMERAS

HuddleCamHD 10X-USB2

MICRON DJ Booth Tri-colour Starcloth

LIGHT BRICK - 12 X 3W TRI-COLOUR

Installation instructions Inclination sensor EC2019 EC / / 2013

Vortex. User Manual. Order code: EQLED073

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

Manual. Simrad IS70/IS80 RPM Indicators RPM70 and RPM80 Speed Indicators SP70 and SP80. English

Performer 18 RGBWA MKII

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

INTRODUCTION PARTS & ACCESSORIES STRUCTURE USING YOUR EXPLORĒ ATTACHING THE STRAP OPERATING YOUR EXPLORĒ

APPLICATION NOTES. HEADING INDICATOR SYSTEMS using XDi-N indicators. Document no.: A

Analog micro push button

1 Introduction. Tilt the screen 2 Installation, safety and maintenance

CM-110SK Standalone Keypad Installation Instructions

Supplied Accessories.

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

Nearus USB2.0 Camera Manual NU-350-USB2PTZ-B

Cobra Dimmer Master DMX Controller User Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Laststufenschalter. Supplement. Betriebsanleitung. Device Profile Document MODBUS

Operating instructions. Speed monitor D / / 2014

WARRANTY CARD. [Document subtitle] [DATE] LENOVO [Company address]

User Manual MagniLink One

CM55-VCU USB 3.0 HD PTZ Camera User Manual v2.1

RGB SQ PROCESSOR BOARD HKSR-5803SQ ADVANCED HQ PROCESSOR BOARD HKSR-5803HQ. INSTALLATION MANUAL 1st Edition

LZR - U920/-U921. LASER MEASUREMENT DEVICE with bidirectional bus communication. User s Guide for product version 0500 and more

Intense 9P10 RGBWA LED Slim Par

Network Camera. Quick Guide DC-S1283WRX. Powered by

HuddleCamHD 3x USB 2.0 PTZ CAMERA INSTALLATION & OPERATION MANUAL

Gobo Projector XP 80W

ECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1

HuddleCamHD 30x USB 3.0 PTZ CAMERA INSTALLATION & OPERATION MANUAL

LED Colour Invader II RGB

Crossfire. User Manual. Order code: EQLED061

REX F-0-9 Standalone or Access Controller

PF LED Profile. User Manual

HD40H(X) Performance Series Camera. User Guide

4-CHANNEL DMX WALL-MOUNTED CONTROLLER

LED Easy Move Double Spot Unlimited

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

Supplied Accessories.

Blitzer Strobe. User Manual. Order code: EQLED366

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

Owner s/installation Manual

Transcription:

DGR360 Digital Gyro Repeater Operating & Installation Manual SKIPPER Electronics AS Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 P. O. Box 151, Manglerud E-mail: support@skipper.no 0612 Oslo, Norway Co. reg. no: NO-965378847-MVA www.skipper.no Document no: DM-R003-SA Rev 2.17A Edition: 20101030 Sw: 2.17

SKIPPER Electronics AS DGR360 Operation and Installation Weitergabe sowie vervielfältigung dieser unterlage, verwertung und mitteilung ihres inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu schadenersatz. Toute communication ou reproduction de ce document, toute exploitation ou communication de ou son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommeges et intèrèts. Copying of this document, and giving it to others and the use or communication of contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, asì como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores Se exigirá el correspondiente resarcimiento de daños y perjuicios. Page 2 of 8 Edition: 20101030 Sw: 2.17

DGR360 Operation and Installation SKIPPER Electronics AS Contents Introduction...4 Operation...5 NMEA Input (Ref: IEC 61162)...5 Connection...6 Specifications...6 User Maintenance...6 Service...6 Installation...7 Edition: 20101030 Sw: 2.17 Page 3 of 8

SKIPPER Electronics AS DGR360 Operation and Installation Introduction DGR360 is a digital gyro repeater that displays the heading angle in the LED segment display and indicates the rate of turn (ROT) with 30 dual-colour surrounding LEDs. The DGR360 will display heading angle given by the THS, HDT or HDM message from a gyro or other equipment (NMEA 0183) and indicate ROT by calculating change in heading based on the THS, HDT or HDM input and the time between each message. The dimming may be controlled by pressing the dimming key or by using an external dimming key. 270 3 DGR360 System On/Off Dimming key Figure 1: Operation Panel Page 4 of 8 Edition: 20101030 Sw: 2.17

DGR360 Operation and Installation SKIPPER Electronics AS Operation System On/Off: Push the On/Off button to switch the repeater on and off. Dimming key: Push the (Dimming key) button to adjust the brightness among 8 dimming levels. The LED displays the heading angle between 0.0 and 359.9. When the heading angle increases (turn starboard), the turning indicators are green. When the heading angle decreases (turn port), the turning indicators are red. The repeater may receive THS, HDT, and HDM messages from more than one source. The unit will choose the THS, HDT or HDM message from the source with best accuracy. The source identities are prioritized in the following order (highto-low): $HETHS, $HEHDT, $GPTHS, $GPHDT, $HCTHS, $HCHDT, $??THS, $??HDT, $HEHDM, $GPHDM, $HCHDM, $??HDM. Prioritizing between the messages are done continually and the LED will display HE T, HE H, GP T, GP H, HC T, HC H,?? T,?? H, HE C, GP C, HC C or?? C for a few seconds when the priority is set or changed. In order to ensure displaying a heading angle from a specific source, all other sources should be removed from the input line. The LEDs will display ERR when the repeater do not receive any signal or if the signal is not recognized as a NMEA message. The LED will display. when the repeater receives THS, HDT or HDM message with empty value field. The LED will display - - - - when the repeater receives THS, HDT or HDM message with incorrect data. The LED will display when the repeater only receives other NMEA messages than THS, HDT and HDM. DGR360 can distinguish and receive baud rates of 4800, 9600, 19200 and 38400 automatically. Presentation of heading angle and turn indication will be affected by the refresh rate of the THS, HDT and HDM signal. Low refresh rate may result in latency compared with real movements. NMEA Input (Ref: IEC 61162) $--HDT,x.x,T*hh<CR><LF> Heading, degrees True $--THS,x.x,A*hh<CR><LF> Heading, degrees True $--HDM,x.x,M*hh<CR><LF> Heading, degrees Magnetic Edition: 20101030 Sw: 2.17 Page 5 of 8

SKIPPER Electronics AS DGR360 Operation and Installation Connection Connecting Colour Signal 1 Red +24V 2 Black -24V 3 Blue NMEA In+ 4 White NMEA In/Out- 5 Orange NMEA Out+ 6 Green Dim+ 7 Yellow Dim- 8 Grey Dim key 9 Shield Gnd Figure 2: Cable connections Specifications Measurement Weight Voltage Power consumption Compass safe distance L: 220 mm, W: 170 mm, H: 63 mm About 2 kg 24 V DC (20-32 V DC) 2 W (24 V DC) 85 cm Environmental (according to IEC 60945 for exposed equipment) Operating temperature Storage temperature Humidity -15 C - +55 C -25 C - +70 C 10 % - 90 % relative humidity Protection IP 56 Note: Operating temperature in the range 0-40 C is recommended and will increase overall lifetime of the product. User Maintenance The repeater is virtually maintenance free, but occasionally cleaning may be necessary depending on the installation. Please use a soft cloth and only mild cleaning chemicals. Service All service requests should be made to your local representative or to the manufacturer. (Contact information on title page). Adjustments and repairs should only be performed by qualified service engineers. Unqualified repair attempts will void the warranty. Page 6 of 8 Edition: 20101030 Sw: 2.17

DGR360 Operation and Installation SKIPPER Electronics AS Installation The unit can be mounted in panel on table, wall or ceiling. For table, wall or ceiling mounting, use the supplied bracket. If panel mount, take off the bracket and take off the front frame. Cut a square window in the panel according to cut out drawing. Fix the inside 4 holes with screws, and put on the front frame again. Figure 3: Mounted on table Note: When mounted in a panel, we advise the size of the hole to be 160 mm x 192 mm. Figure 4: Mounted in panel Edition: 20101030 Sw: 2.17 Page 7 of 8