Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Similar documents
Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Vent Controller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

BACnet Terminal Box (VAV) Controller

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Siemens BACnet VAV Actuator

Dual Duct Controller - One Air Velocity

BACnet Protocol Implementation Conformance (PIC) Statement

oom Pressurization Con

PXC Compact Series on BACnet/IP

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

PXC Modular Series for BACnet Networks

BACnet PTEC Controller Heat Pump Multi-Stage Slave Mode, Application Application Note Building Technologies

TEC Terminal Box (VAV) Controller

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

FXVMA Variable Air Volume (VAV) Box Controller

TALON Network Manager- 2 & 6 Express

TEC Unit Conditioner Controller

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

BACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

TC Modular Series for BACnet Networks

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

Room Pressurization Controller Pneumatic Output

Andover ContinuumTM. b3850 Series Terminal Controllers

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

Room Pressurization Controller Electronic Output

TC Compact Series Unitary Equipment Controller

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Heatronic Introduction. BAS Integration Manual. Table of Contents

VZ7000 Series. BACnet Commercial Zoning System

Field selectable application type and room module series, via dip-switches on controller

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Compact Series Unitary Equipment Controller

RWD68U Universal Controller

System Controls Suggested Specification

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

FUME HOOD CONTROLLER (FHC)

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

SEZ7000 Series. Wireless Commercial Zoning System

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

Actuating Terminal Equipment Controller (ATEC) VAV with Reheat. Start-up Procedures Building Technologies Restricted

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

BACnet. b3867 Terminal Controllers

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

BACnet Integration Manual ITG-VZ7xxx-BAC-E04.doc ( _R4 Issue Date: May 31 st, 2012)

Actuator Commissioning Tool

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.

SE7600E Series Application Guide

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Underfloor Controllers

Modular Building Controller

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

MS/TP Point Pickup Module Owner's Manual

NXAC-120 Area Controller

TC-9102 Terminal Controller

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

BACnet. b3810 Series Local Controllers

Delta Controller Engine (DCE) Firmware

BACnet IP for Quantum

Airflow Pressure Sensor

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Specification Sheet For electronically commutated motors

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

THERMOSTATS & CONTROLLERS

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

BACnet Driver on the TC Series Platform

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

Siemens TEC Extended I/O Controller

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

Sales and Engineering Data Sheet ED

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

Transcription:

Technical Specification Sheet Document No. 149-851 September 24, 2014 Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller The Siemens BACnet PTEC Dual Duct Controller provides high performance Direct Digital Control (DDC) technology for room temperature control in Dual Duct Variable Air Volume (VAV) systems or air volume setpoints and room temperature control in Constant Volume (CV) systems. The DDC and related components provide a totally electronic control system. The DDC can operate independently, standalone or networked to perform complex HVAC control, monitoring and energy management functions. This controller is designed to reside on any BACnet control system. Features Communicates using BACnet MS/TP protocol for open communications on BACnet MS/TP networks. BTL listed as a B-ASC device. Programmable using PPCL. Plenum rated controller. Setpoints and control parameters assigned and changed locally or remotely. Setpoints and control parameters stored in Electrically Erasable Programmable Read Only Memory (EEPROM) no battery backup required. Returns from power failure without operator intervention. Meets low duct static pressure requirements PID control of HVAC systems to minimize offset and maintain tighter setpoint control. Unique control algorithms for specific applications. No calibration required, thereby reducing maintenance costs. Separate minimum and maximum air volume setting for heating and cooling modes. Separate air volume setpoints for occupied and unoccupied modes (CV Application only). Applications Constant Volume Two Inlet Sensors with Optional Reheat (Application 6565) Constant Volume One Inlet and One Outlet Sensor with Optional Reheat (Application 6566) Variable Air Volume Two Inlet Sensors with Optional Reheat (Application 6567) Variable Air Volume One Inlet and One Outlet Sensor with Optional Reheat (Application 6568) Variable Air Volume with Changeover (Application 6569) If required, new custom code using our PPCL programming language can be added to replace or supplement the standard application residing in the Page 1 of 5

controller. This provides the flexibility to meet many job specifications with the assurance of having a proven and tested standard application to rely upon. Hardware Controller Board The Siemens BACnet PTEC Dual Duct Controller consists of an electronic controller assembly and onboard differential pressure transducer(s). This controller provides all wiring terminations for system and local communication and power. The cable from the room sensor (purchased separately) connects to an RJ-11 jack on the controller. All other connections are removable terminal blocks. The controller assembly is mounted on a plastic track that mounts directly on the terminal box. An optional enclosure (P/N 550-002) protects the controller assembly. Autozero Modules are available for mounting on the controller for those applications where uninterrupted airflow is necessary. A Pneumatic Transducer provides control of pneumatic damper and valve actuators. The controller interfaces with the following external devices: Averaging air velocity sensors provided by VAV terminal unit manufacturers Floating control valve and damper actuators Temperature sensors (room, duct, immersion, and outside air) Service and commissioning tools Digital input devices (dry contacts from motion sensors, alarm contacts) Digital output devices (fan, stages of electric heat) Room Sensor The room sensor connection to the controller board consists of a quick-connect RJ-11 jack. This streamlines installation and reduces controller start-up time. Series 2200 Temperature Room Units for TEC and ATEC Technical Specification Sheet (149-820), for more information. Dual Duct 2 AVS Controller Specifications Dimensions Weight Controlled Temperature Accuracy, Heating or Cooling Power Requirements Operating Range Power Consumption Inputs Analog Digital Outputs Analog Digital Communications 4-1/8" W 11-1/4" L 1-1/2" H approx. 3 lbs (1.35 kg) ±1.5 F (0.9 C) 19.2 to 27.6 Vac, 50 or 60 Hz 10 VA (plus 12 VA per DO) 1 room temperature sensor 2 velocity sensors 1 setpoint (optional) 1 auxiliary temperature sensor 2 selectable 0-10 Vdc/4-20 ma 3 dry contacts 3 0-10 Vdc 8 DO 24 Vac optically isolated solid state switches @ 0.5 amp Remote BACnet MS/TP (EIA 485), 9600 bps to 76800 bps FLN Trunk Local Ambient Conditions WCIS and PTEC Tool Combination Temperature and Relative Humidity Models The Series 2200 range of TEC room units includes combination temperature and humidity models. For these models, both temperature and relative humidity values are passed digitally to the TEC. This information is passed from the room unit through the RJ-11 cable to the RTS port on the TEC. See the Shipping & Storage Temperature Operating Temperature Humidity Range -13 F to 158 F (-25 C to 70 C) 32 F to 122 F (0 C to 50 C) 5% to 95% rh (non-condensing) Page 2 of 5

Agency Listings UL Listing UL 916, PAZX cul Listed Canadian Standards C22.2 No. 205-M1983, PAZX7 FCC Compliance 47 CFR Part 15 Differential Pressure Sensor The differential pressure sensor is easily connected to the box s air-velocity sensing elements to provide measurement of the differential pressure. The measured value is converted to actual airflow in cfm (lps) by the controller. Differential Pressure Sensor Specifications Temperature Range Measurement Range Autozero Module 32 F to 122 F (0 C to 50 C) 0 to 5200 fpm (0 to 26 m/s) The optional Autozero Module (see Figure Autozero Module) is required when continuous operation at occupied flow is required for an area. The Autozero Module is connected to the air velocity inlet ports of the controller and provides periodic recalibration of the air velocity transducer without changing air volume being delivered to a room. This recalibration ensures long-term precise airflow delivery. Autozero Module Specifications Power Consumption.75 VA @ 24 Vac max. Autozero Module. Ordering Information Description Siemens BACnet PTEC Dual Duct Controller Large enclosure for electronic controller without damper actuator (long board). Document Information Technical Specification Sheets/Technical Instructions Room Temperature Sensors Series 2200 Part Number 550-497P 550-002 Document Part Number 149-820 Duct Temperature Sensor 149-134P25 Low Limit Detection Thermostat 155-016P25 Analog Sensors 10 K Ohm Thermistor 149-912, 149-915, and 149-916 Siemens Valves and Electronic Actuators 599 Series Zone Valves 2-Way, 3-Way Zone Valve Electric and Thermic Actuators 155-034 Dimensions 2" W x 1.51" H x 1.89" D (58 mm x 78 mm x 29 mm) Weight 1.3 oz. (36.9 g) 599 Series Zone Valves and Actuators Modulating, On/Off Spring Return, 2- Position Control 155-063 Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. or company names mentioned herein may be the trademarks of their respective owners. 2014 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel. 1 + 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com. Document No. 149-851 Printed in the USA Page 3 of 5

BACnet Protocol Implementation Conformance Statement s Model Number Protocol Software Firmware Siemens BACnet PTEC Dual Duct Controller 550-497P 4 (135-2004) 2.0.5.1 BD43 Date Tested: July 2011 B-ASC Vendor Information Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.buildingtechnologies.siemens.com/bt/us Description The controller is an integral part of Siemens controls system. The controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring, and energy management functions. This controller communicates using BACnet MS/TP. BACnet Standardized Device Profile Device Profile Tested PTEC BACnet Application Specific Controller (B-ASC) Supported BACnet Interoperability Building Block (BIBBs) BIBB Name Tested PTEC DS-RP-B Data Sharing-ReadProperty-B DS-RPM-B Data Sharing-ReadPropertyMultiple-B DS-WP-B Data Sharing-WriteProperty-B DM-DDB-B Device Management-Dynamic Device Binding-B DM-DOB-B Device Management-Dynamic Object Binding-B DM-DDC-B Device Management-DeviceCommunicationControl-B DM-RD-B Device Management-ReinitializeDevice-B DM-BR-B Device Management-Backup and Restore-B DM-OCD-B Device Management-Object Creation and Deletion-B Page 4 of 5

Standard Object Types Supported Object Type Creatable Deletable PTEC Analog Input No No Analog Output Yes Yes Binary Input No No Binary Output Yes Yes Device No No File Yes Yes Program Yes Yes Data Link Layer Options Data Link and Options MS/TP master (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps MS/TP slave (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps Segmentation Capability Segmentation Type Supported Window Size: 32 (MS/TP product limited to 1) Able to transmit segmented messages No Able to receive segmented messages No Device Address Binding Static Device Binding Supported Yes Networking Options Static Device Binding Supported No Character Sets Charcter Sets Supported ANSI X3.4 Page 5 of 5