Serial Communication

Similar documents
Introduction. Upon completion of Power Monitoring and Management with ACCESS you should be able to: Identify five benefits of using the ACCESS system

Chapter 8 OSI Physical Layer

DTU3005-B Intelligent Data Transfer Device for Connection to PLCs and Modbus Networks Operator s Manual

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Ethernet Remote Master (ERM)

with its cables, connectors, Switches, Hubs and topologies

Communications and Protocol Basics

Physical Layer V What does the physical layer provide?

Accessories IC690ACC900

Lecture: Communication in PLC

Bus Transmitter Expansion Module (Fiber Media) with built-in switch. PROFINET Slave, Version 2.2 Class A IO-Device

Accessories / 7XV5662

Building the Communication Cable

CCNA 1 Capítulo 8 OSI Physical Layer. 2004, Cisco Systems, Inc. All rights reserved.

Tutorial 3 (Ethernet)

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

PROFIBUS and Integrated Safety architectures in Ex areas

SIMOREG 6RA70 DC MASTER Electronics

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Bus Cover Description for Shaft Encoder

RS-232 Serial RS-485 Serial Ethernet

9.3. Metering Devices, Protective Relays, Software and Connectivity

Troubleshooting PLCs & SCADA Systems

Substation monitoring and control

Internetworking is connecting two or more computer networks with some sort of routing device to exchange traffic back and forth, and guide traffic on

Retentive On-Delay (TONR)

Dupline Fieldbus Components

DRAFT. Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters. 1.0 Introduction DANGER. 1.1 Related Documents

PROFIBUS Workshop EN B U I L D I N G P R O C E S S M A N U F A C T U R I N G EUROPEAN FIELDBUS STANDARD. Chapter 1 Date 11/04/99, page 1

FD67 QUICK START GUIDE PROFIBUS-DP

Data sheet CC 03, Commander Compact (603-1CC21)

Introduction to PROFIBUS for Process Automation

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Bus communication with ABB circuit-breakers

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Serial Port Complete

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Modbus RTU Serial Communication User Manual

This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

Addendum for 125B Bushealth Measurements

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

Control and Protection System Win-TDC

Code Dynamics, Inc. Port Splitter

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA SELECTION AND APPLICATIONS OF PROGRAMMABLE LOGIC CONTROLLERS UNIT 25 - NQF LEVEL 3

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

FOURSTAR PROFIBUS HUB. FS-PBHUB-4 FS-PBHUB-6 User Manual

Chapter 4: Network Access

Equipment Operation & Maintenance

Chapter 7: Data Link Control. CS420/520 Axel Krings Page 1

Chapter 7: Data Link Control. Data Link Control Protocols

Xcel Energy Telemetry Requirements for Distributed Energy Resource Interconnections: Revision 3.1

IDM DATA ACQUISITION SYSTEM

TIM 3V- IE ADVANCED. Function

Introduction to Information Technology Turban, Rainer and Potter John Wiley & Sons, Inc. Copyright 2005

SX-E - SCADA Systems for Industry

Manual Fiber Optic Interfaces

Serial Communication Converters & Adapters Instruction Manual

7XV5103 RS485 Bus Systems up to 115 kbit/s (not suitable for PROFIBUS)

Ethernet Technologies

RS-485 module. Data sheet. for electricity meters

Commercial-grade Interface Converter User Manual

Pow-R-Command System Overview

7SG18 Solkor N Numeric Differential Protection

Meter Bus. Intelligent Communication

Installation and Setup

Review For Exam 2. Internetworking. Summary Questions. School of Business Eastern Illinois University. School of Business Eastern Illinois University

ANSI/TIA/EIA-568-B Cabling Standard

CS485. User s Manual. Version ZYPEX, Inc.

Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

The SpeedTouch and Ethernet Connectivity

PROFIBUS-DP/MODBUS RTU REPEATER

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Modbus/ PROFIBUS DP Gateway PM-160

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Data sheet CPU 315SN/NET (315-4NE12)

SECTION ELECTRIC METERING

XPort Direct+ NC Addendum

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

EP/2 Installation Instructions

Data sheet CPU 315SN/NET (315-4NE12)

IE102: SCADA Programming, Maintenance & Troubleshooting

DVPPF02-SL PROFIBUS DP Slave Communication Module

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules

Chapter 9. Ethernet. Part II

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

General. Remote I/O A4/1.

EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER COMMUNICATIONS MANUAL. EVO - Microprocessor Controlled Float Battery Charger JA

WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM Revised 4/30/ Electrical Systems

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

4.6 PT8AIIS ISOLATED ANALOG CURRENT INPUTS Description

Momentum 171 CCC Processor with Ethernet Communication Port

BioPointe Reader Installation Guide

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Structure and Function

Telecontrol and Automation Systems

ACORN User Guide For Revision (Aka Acorn_rev3) Updated 1/23/17

APPLICATION MANUAL for NETWORK

Transcription:

Serial Communication RS-232 and RS-485 are Electronic Industries Association (EIA) specifications commonly used for serial data communication. Siemens ACCESS devices support the RS-485 as standard. Some ACCESS devices also support the RS-232 standard. RS-232 RS-232 is a serial communication protocol which sends and receives information through twisted pair cable. It is common to see both 9-pin and 25-pin RS-232 connectors. It is important to note that although the RS-232 standard consists of 25 transmission lines, many applications do not require all the lines available. Depending on the device, manufacturers use various combinations of the transmission lines available. The following illustration, for example, shows the connector requirements for equipment used in the Siemens ACCESS system. 46

RS-232 uses what is referred to as an unbalanced signal or communication method. There is one signal wire for each circuit with a common return. The driver sends a series of binary signals to the receiver. These binary pulses make up predefined words that either give the status of a system being monitored or provide commands to control an event. This method is susceptible to unwanted electrical noise. The RS-232 standard supports only one driver (transmitter) and one receiver with distances limited to no greater than 50 feet. RS-485 RS-485 is a communication standard that is better suited for industrial applications that involve distances greater than 50 feet. The RS-485 standard can support up to 32 devices over a maximum distance of 4000 feet. The RS-485 standard uses a twisted pair of wires for each circuit with differential drivers and receivers. This method provides a balanced signal which cancels out signal noise to allow for better data integrity. 47

Typically, at the top level of a communication system is a host computer with an RS-232 interface. The host computer may have to communicate with an RS-485 device. In this situation a converter, such as a Siemens isolated multi-drop converter can be used. Isolated Multi-Drop Converter The Isolated Multi-Drop Converter is an RS-232 to RS-485 converter that provides connectivity between a computer s RS- 232 serial port and a Siemens SEABus RS-485 communications loop for ACCESS field devices. A multi-drop converter will accept up to four RS-485 input loops. Each input loop will support up to 32 devices. One isolated multi-drop converter can handle up to 128 field devices. 48

Using the Isolated Muli-Drop Converter In the following illustration a computer communicates with various ACCESS field devices through an RS-232 interface and isolated multi-drop converter. Communicating on a LAN Field devices in the Siemens ACCESS product line that cannot communicate directly on a LAN, such as Ethernet, can be connected to the LAN through an Ethernet converter. When more than 32 field devices are used an isolated multi-drop converter is also required. 49

Modem Modems are electronic devices used for sending and receiving data over long distances. The Siemens ACCESS system also supports data communication through a modem. In the following illustration a remote computer communicates to an isolated multi-drop converter through a modem. Fiber Optics Fiber optics is a method for transmitting data using light. A basic system consists of a transmitting device which generates a light signal, a fiber optic cable, and a receiving device. In the following illustration a supervisory computer is connected to a fiber optic converter through an RS-232 interface. At the other end of the fiber optic cable is another RS-232 to fiber optic converter which is connected to an isolated multi-drop converter. The RS-485 output of the multi-drop converter is connected to various field devices. 50

DTU3005 The DTU3005 is a multiple-function data transfer unit, which acts as an intelligent device to request information from up to 32 ACCESS devices. The requested information is then made available to PLCs and various industrial automation networks such as ModBus and PROFIBUS DP. There are two models, the DTU3005-P and DTU3005-B. The following illustration shows two possible configurations. Up to 32 Siemens ACCESS devices can be connected to one port of the DTU3005. In one example, a PLC or ModBus master device can be connected to one port of a DTU3005-B. A second ModBus device or an optional supervisory PLC can be connected with SEABus to another port. In the second example, PROFIBUS devices are connected via an RS-485 port on the DTU3005-P. A supervisory PC is connected to an available port. 51

Local Display Unit The Local Display Unit (LDU) works with the SEABus network to poll data from Siemens ACCESS compatible devices. The LDU can be mounted in harsh industrial environments and is suitable for mounting in panelboards, switchboards, and switchgear. The LDU can be connected through SEABus to up to 32 ACCESS devices. A second port can be connected through RS-232 to a WinPM monitoring station. 52

Review 4 1. WinPM is an example of a device. a. supervisory b. field 2. A Siemens ACCESS power meter is an example of a device. a. supervisory b. field 3. The rules that govern the communication fo the ACCESS system are known collectively as and Plus. 4. A is an active device, such as a computer or printer, connected to the network. 5. Siemens can connect RS-232 and RS-485 devices directly to a LAN. 6. RS-232 is limited to transmission distances no greater than feet. 7. RS-485 can support 32 different drivers and receivers over a maximum distance of feet. 8. The LDU can be connected to up to ACCESS devices. 53