Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Similar documents
SP6R Level Controller Operation Manual

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

LC-1 Level Controller & Flow Monitor

LC-5 Level Controller & Flow Monitor

Operating Instructions. For. Level Control Module. Model SSR 1000

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Contents. Temperature & Process Measurement Indicators Setup Guide

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Level-Lance Model 5400A

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

MODEL SIB-V245 / V453

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

CDD Carbon Dioxide Transmitter

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

CDD4 Duct Carbon Dioxide Transmitter

LCI User Manual mantracourt.com

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

SP6R-LSC CONTROLLER. User Manual. DUPLEX LIFT STATION CONTROL BAR GRAPH 4-20 ma INPUT AUTOMATIC ALTERNATION MOTOR STATUS LEDs

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

LC-3 Flow Monitor & Pump Run Verification

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

TPE 1464 Series Pressure Transducer

IPS INTELLIGENT PUMP STARTER

CDD4 Series Room CO2 Transmitter Installation Instructions

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

Trident and Trident X2 Digital Process and Temperature Panel Meter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Tempco Instruction Manual

High Voltage DC Meter

TC-9102 Series Surface Mount Temperature Controllers

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

User's Guide. 1/16 th DIN ph Controller. Model 48PH2. Introduction

ULTRASONIC LEVEL CONTROLLER DISPLAY

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PD765 TRIDENT. Trident Series Process & Temperature Meters.

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

HIGH-VOLTAGE DC METER

PD765 TRIDENT. Trident Series Process & Temperature Meters.

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

3 Uninterruptible Power Systems

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

VLT 2800 DRIVE SPECIFICATIONS

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

TOXALERT MODEL AIR 2000

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Carbon Monoxide (CO) Gas Detection and Control System

Signet Pressure Transmitter

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MICRO GROW GREENHOUSE SYSTEMS, INC

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Multi-Point Gas Detection and Control System

CONTROL SYSTEMS SOLUTIONS FOR PRECISION MOTION TECHNOLOGY. Your First Choice. for Control Systems Solutions

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Catalog Index Page Description C A Briggs Company -

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

H704-42(H)(E), H704-42/1(H)(E)

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

dual-line 6-dIGIt process MeteR

MAXIMA+ Series Rotary Level Indicator

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

H7625A, H7635A Humidity/Temperature Sensors

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Carbon Monoxide Sensor - ModBus

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

MODEL 8000MP LEVEL SENSOR

AUTOMATION. Operator s Manual PG-7. Full Access. Doc Part Rev B, 07/18. Automation Products Group, Inc.

NEMA 6 Enclosure INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON.

INSTALLATION INSTRUCTIONS

Transcription:

DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping systems. The Model 4052 monitors, controls and displays the liquid level in a tank or reservoir, up to a depth of 34.6 feet. The input to the Model 4052 can be from any 2 or 3-wire transducer with a output that represents 0 to 34.6 feet. A 24VDC regulated probe supply is included. A Level Simulator is provided to aid in programming these five set points; Low Alarm, Pumps Off, Level 1, Level 2 and High Alarm. A universal zero to 30 second On Delay can be programmed to prevent outputs from closing due to input fluctuations caused by turbulent conditions. An additional output with zero and span controls is provided for a chart recorder or other external device. Four heavy-duty 10 amp, 240V contacts are provided for pump control and alarm activation. An auto-dialer or other emergency device can be activated with the SPDT power loss relay. This relay is held open when power is applied. Pump outputs include duplex alternation as well as hand-off-auto switches. Pump run-time can be displayed for each pump with tenth of an hour resolution, up to 99,999.9 hours. The Model 4052 can be panel-mounted (11 1/8 x 4 5/8 ), same as Time Mark Models 403, 404 and 4042, or surface-mounted using the optional surface-mounting kit, Model 4000. SPECIFICATIONS Input Voltage Pwr Consumption Signal Input Signal Input Load Dead Band Repeat Accuracy Display Type 120VAC ± 10% 50/60Hz 8W max. (optional 0-5V), 2 or 3 wire 250 ohms max. 1% of full scale ± 1% of scaled max. (fixed conditions) 6 digit red LED display Display Ranges Level: 00.0 to 34.6 ft with input Runtime: zero to 99,999.9 hours Delay: zero to 30 seconds Display Resolution Control Contacts Power Loss Relay Signal Output Signal Output Load Probe Supply Setpoints Operating Temp 1 decimal place 4 SPDT 10A at 120VAC resistive 1 SPDT 5A at 120VAC resistive Output is factory set to track the input. Zero and span adjustments are provided: as little as a 2mA change can cause a full swing of the output. 300 ohms max. 24VDC regulated 3 levels, 2 alarms, all user-adjustable +14º to +122º F Humidity Tolerance 0-97% w/o condensation Enclosure Material 16 gauge steel Termination removable terminal strips Dimensions H: 5.5 W: 12.0 D: 4.75 Weight 6.0 pounds Agency Approvals DIMENSIONS UL Recognized (U.S. & Canadian) Page 1 of 6 11/2011

Pump Down Controller READ ALL STRUCTIONS BEFORE STALLG, OPERATG OR SERVICG THIS DEVICE. KEEP THIS DATA SHEET FOR FUTURE REFERENCE. GENERAL SAFETY POTENTIALLY HAZARDOUS VOLTAGES ARE PRESENT AT THE TERMALS OF THE. ALL ELECTRICAL SHOULD BE REMOVED WHEN CONNECTG OR DISCONNECTG WIRG. DO NOT EXCEED THE PUT OR PUT RATGS, AS STATED THE SPECIFICATIONS. PROTECT THE UNIT WITH PROPERLY RATED FUSES. DO NOT STALL DAMP OR MOIST AREAS. THIS DEVICE SHOULD BE STALLED AND SERVICED BY QUALIFIED PERSONNEL. figure 1. Front Panel Controls Installation Instructions A 6 digit LED display B Indicates display is showing LIQUID LEVEL C Indicates display is showing #1 runtime D Indicates display is showing #2 runtime E Switches display between B, C and D F Push to enter SET mode G Push to CREASE setting H Push to DECREASE setting M Indicates display is showing HIGH setting N Indicates display is showing ON DELAY setting O Controls ZERO setting for 4 to 20mA output P Controls SPAN setting for 4 to 20mA output Q Indicates LOW ACTIVE (low alarm relay-closed) R Indicates #1 RUNNG (pump #1 relay-closed) S Indicates #2 RUNNG (pump #2 relay-closed) T Indicates HIGH ACTIVE (high alarm relay-closed) I Indicates display is showing LEVEL 1 setting U 3-position switch HAND-OFF-AUTO Pump #1 J Indicates display is showing S OFF setting V 3-position switch HAND-OFF-AUTO Pump #2 K Indicates display is showing LOW setting L Indicates display is showing LEVEL 2 setting W Momentary pushbutton engages LEVEL SIMULATOR X Controls SIMULATED LEVEL (when SIMULATOR button is engaged) Page 2 of 6 11/2011

Pump Down Controller figure 2. CONTROL PUTS 1 2 HI- SIGNAL PUT/PUT LO- FAIL AC L N G MOUNTG & WIRG FAIL OPERATG Mount the Model 4052 Pump-Down Controller in a panel or suitable enclosure (see Time Mark s Model 4000 Surface Mount kit). Referring to the terminal block decals on the unit, and Figure 2, make the following connections: SIGNAL PUT With a 3-wire transducer (see Time Mark Model 450) remotely mounted, connect the terminal to the voltage input of the transducer (figure 3). Connect the terminals to the loop terminals of the transducer. OBSERVE POLARITY. figure 3. P 5 P 8 MODEL 450 P 4 3-WIRE TRANSDUCER Connect a 2-wire transducer (pressure, ultrasonic, etc.) as shown in figure 4. figure 4. + EXCITATION (RED) - EXCITATION (BLK) MODEL 456-15 PRESSURE TRANSDUCER SIGNAL PUT The output is proportional to the input signal. This allows for very accurate remote monitoring of level changes. The factory default is for the output to track the input; that is, a 4mA signal represents 00.0 feet, and a 20mA signal represents 34.6 feet. However, the output can be zeroed and spanned to a specific range, not necessarily the same as the reading on the LED display. The terminals may be connected to a remote display or other devices. Connect these terminals as required for your application. OBSERVE POLARITY of the connections. PUTS SPDT contacts are provided for 1, 2, HI-, LO- and FAIL relays. Make wiring connections as required. OPERATG Connect a chassis ground to the lug marked and the terminal marked G. Connect 120VAC operating power to the terminals marked L (line) and N (neutral). Page 3 of 6 11/2011

Pump Down Controller PROGRAMMG - SET mode The Model 4052 Controller has been factory tested and calibrated. Factory settings are as follows: HIGH LEVEL 2 LEVEL 1 S OFF LOW 10.0 ft 8.0 ft 6.0 ft 4.0 ft 2.0 ft NOTE: Both Hand-Off-Auto (H.O.A.) switches MUST be in the OFF position before entering the SET mode. To enter the SET mode, push the button marked SET (figure 1 F ). The display will now show the LOW setpoint. Change the LOW setpoint to the desired level, using the UP/DOWN arrows (figure 1 G,H) to the right of the SET button. After setting the LOW setpoint, press the SET button again. The display now shows the S OFF setting. Using this same procedure, set the S OFF, LEVEL 1, LEVEL 2, and HIGH settings (in that order). After setting the HIGH, press the SET button, to display the factory setting for the ON DELAY timer. Use the UP/DOWN buttons (figure 1 G,H) to set the ON DELAY to the desired setting (0 to 30 seconds). After setting the ON DELAY time period, press the SET button again to enter the setting into memory. Review all settings by cycling through the setpoints before proceeding to the DISPLAY mode. Finally, press the DISPLAY button, to enter all settings into memory. OPERATION - DISPLAY mode While in DISPLAY mode, the LIQUID LEVEL is shown on the LED display. Pushing the DISPLAY button, while in the DISPLAY mode will change the LED display from LIQUID LEVEL to RUN TIME #1 to RUN TIME #2, and back to LIQUID LEVEL. If the DISPLAY button is not pushed for 60 seconds, the LED display will automatically return to the LIQUID LEVEL setting. NOTE: The LOW, S OFF LEVEL 1 and LEVEL 2 settings must move up in value from LOW to LEVEL 2, to be properly set. The Model 4052 will not enter the DISPLAY mode if these settings are improper. When trying to move to the DISPLAY mode with improper settings, the LED display will automatically return to the SET mode. Adjust the improper setpoint, then continue. The HIGH setpoint can be set anywhere within the scale. VERIFYG SETTGS Before entering automatic operation, the program setting should be reviewed and verified using the following procedure. While in the DISPLAY mode (with H.O.A. switched in the OFF position), the LEVEL SIMULATOR can be engaged. Push the LEVEL SIMULATOR momentary push-button (fig. 1 W), and hold it down. The input to the external transducer will be disabled and internal level simulator will take its place. Turning the potentiometer (figure 1 X ), will simulate changes to the liquid level being monitored. In this mode, simulated changes in liquid level will cause the alarm relays to open and close, the liquid level to change on the numeric display, and all LEDs to operate ( 1 and 2 LEDs will flash). NOTES: RETURN THE SIMULATOR KNOB TO THE MIMUM SETTG BEFORE RELEASG THE SIMULATOR BUTTON. The 1 and 2 relays will not energize in the LEVEL SIMULATOR mode. AUTOMATIC OPERATION For fully automatic operation, set the display to monitor the liquid level, and move the HAND-OFF-AUTO switches to the AUTO position. MANUAL OPERATION To manually operate either of the pumps, push the momentary HAND-OFF-AUTO toggle switch for the appropriate pump down to the HAND position, and hold. WARRANTY This product is warranted to be free from defects in materials and workmanship for one year. Should this device fail to operate, we will repair it for one year from the date of manufacture. For complete warranty details, see the Terms and Conditions of Sales page in the front section of the Time Mark catalog or contact Time Mark at 1-800-862-2875. Page 4 of 6 11/2011

Pump Down Controller TYPICAL APPLICATION - Transducer 34. 6 120 VAC SIGNAL ~ HIGH LOW FAIL HIGH LEVEL 2 LEVEL 1 S OFF LOW Model 456-15 Submersible Pressure Transducer 0-15psi = 0-34.6 ft 0-34.6ft = Up to 34.6 ft TYPICAL APPLICATION - Float Switches 1 2 34. 6 120 VAC ~ HIGH LOW FAIL SWITCH TO LOOP CONVERTER FLOAT SWITCHES 5 4 3 2 1 HIGH LEVEL 2 LEVEL 1 S OFF LOW Up to 34.6 ft 1 2 STALLATION WORKSHEET JOB NAME: DATE: SETPOTS FACTORY SETTG SET AT LEVEL: NOTES High Alarm 10 ft Level 2 8 ft Level 1 6 ft Pumps Off 4 ft Low Alarm 2 ft Page 5 of 6 11/2011

MC Optional Configuration Monitor Motor Control Contacts Disable Run Time Meters In Fault Condition STALLATION DRAWG MC1/MC2 CONNECTIONS MC 1 C NO/NC 1 C NO/NC MC1 MC2 COM M1 M2 MODEL 460 The Model 460 Switch-to-Loop Converter is designed to output a specific loop current when each input switch is closed. Up to six switches can be used as inputs to liquid level control devices. Liquid level controllers generally require a loop current that represents the level of liquid in a tank or reservoir and are usually generated by an expensive pressure transducer or ultrasonic sensor. If you already have a tank with float switches installed, the Model 460 allows you to take advantage of the latest liquid level control, without the added cost of a transducer. Each of the six inputs can be set to output from when closed. When an input switch is closed, the output changes to the corresponding current level. The highest of the six input switches (that is closed) determines the level of current at the output. If none of the switches are closed, the output is 4mA. For complete information on the Model 460, see the data sheet in the Time Mark catalog. MODEL 4000 Surface-Mount Kit 20 Ga. CRS Enclosure Removable Access Panel Switch-to-Loop Converter For Float Switch Applications Six Level Inputs 4 to 20mA Output 4052MC Connector The 4052MC option adds the capability of monitoring motor starters. When the 4052 calls for a pump to run the corresponding CONTACTOR CONTACTOR MC contact should close. If the MC contact closes, the pump controller will increment the run time for that pump. If the MC contact does not close, or opens after the pump has been started, the pump controller will not increment the run time for that motor and will flash the Run Time light on the left side of the controller for the corresponding pump. Designed to easily install Time Mark Models 403, 404, 4042, 4052, 4062, or 408 Liquid Level Controllers. This 20 gauge steel enclosure features a removable top panel for easy access to wiring connections. The mounting kit comes complete with everything you need, including steel support brackets. This model is designed specifically for applications that require surface-mounting these Time Mark Liquid Level Controllers. For more information, see the full data sheet in the Time Mark standard products catalog. Page 6 of 6 11/2011