NF760 Batch Controller

Similar documents
NF770 Temperature Compensation Liquid Flow Computer

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Digital Indicator Solutions

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

FEATURES DESCRIPTION FEATURES

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL ELECTRONICS, INC.

Batch Controller with numerical keypad and receipt printer driver

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

LAUREL ELECTRONICS, INC.

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Product Description. Contents. Fusion Series. New Information December 2003

Easy To Use OEMS Take Note

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Trident and Trident X2 Digital Process and Temperature Panel Meter

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

02/11/2015

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LBVR1718. Description. Features channel paperless recorder

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

VersaMax Micro and Nano Technical Product Presentation

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

VEGA II. Electronic counter. The solutions that count

DS 500 Intelligent chart recorder for compressed air and gases

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

SINGLE-CHANNEL PROCESS INDICATOR series 8001

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

NFC110. Flow Computer For Low Pulses FEATURES

Omega and Red Lion team-up!

/8 DIN Universal Process Indicator

Neon pr. ph/ ORP measurement. Applications. Description

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

GFC114. Low Power Flow Computer FEATURES

MIC-2 Multi-instrument DATA SHEET

GreenEye Monitor Specifications

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

MIC-2 MKII, Multi-instrument DATA SHEET

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

Andover ContinuumTM Infinet II

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

FULMATIC 7 SILVER SERIES PLC PLC USER S MANUAL

SUPERtrol-I LE Flow Computer

Technical specification Marine Master Clock

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

SX 6000 Paperless Recorder

GFM TIO GFC TIO. GFM with TIO Mounted. GFC with TIO Mounted TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER. Design Features

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Q9 ASD LOW VOLTAGE DRIVE

EGW1-IA3-MB User s Manual

Temperature, Process &

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

mxcontrol Multifunction Controller

BACnet. b3810 Series Local Controllers

Andover ContinuumTM. b3850 Series Terminal Controllers

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

FEATURES DESCRIPTION SPECIFICATIONS

RS-485 I/O Modules: ADAM-4000

Power Meter PowerMonitor 500

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

Clear Benefits of the KRAL Electronic.

Select a Micro800 Controller

PXR Series Advanced Self-Tuning Temperature and Process Controllers

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

USER MANUAL 2012 V1.1

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

BATCH CONTROLLER. Features. Input Options F130. DC powered with 7 yr battery or mains option. Overview

RS 485 Mini Modbus 1AO

LAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Energy Monitoring Solutions

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

KRAL Electronics BEM 300 and BEM 500.

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Wall-/Pipe Mounted Universal Process Indicator

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

/8 DIN Motorized Valve Controller

C500 Series Data Sheet

Transcription:

NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total and preset value can all be displayed in engineering units on the large LCD display. Either the Flow Rate or a Resettable Total can be continuously displayed in engineering units on the Graphic LCD display. A non-resettable Accumulated Total is also displayed whenever the DISPLAY key is pressed. Batch Features Automatic Overrun Compensation Based on previous batches, the NF760 will automatically compensate for any overrun which may be caused by slow closing valves Batch Limit A maximum batch quantity can be programmed during set-up, so that the operator cannot enter a batch size that exceeds this limit. Remote Start/Stop Remote push-button switches can be connected to the rear terminal strip, to start and stop batches. Auto Restart The NF760 can be programmed to automatically restart the batch after a preset time delay Count Up/Down The instrument can be programmed to count up from zero, or to count down from the batch quantity. End of Batch An End of Batch signal is provided via an open collector transistor output Features at a glance Dual relay outputs Overrun compensation Remote start/stop No-signal alarm Ticket printing with time and date Displays batch total, preset quantity, flow rate, and accumulated total Backlight Display RS232 and RS422/485 communications interface 1

Processing Time Chart 2

Specifications General Display 98X23mm Graphic LCD (Backlight) Display Update Rate 250ms Transducer Supply 8-24V dc field adjustable, 100mA max Power Requirements DC Supply: 14 to 28V dc, 300mA typical (No options) AC Supply: AC mains set internally to 95-135V ac or 190-260V ac, 50Hz/ 60Hz, 100mA. Operating Temperature 0 to 55 C Dimension 146mm (w) X 75mm (h) X 139mm (d) Panel cutout 139mm (w) X 66.5mm (h) Frequency Input Range Minimum : 0.25Hz on Rate, 0Hz on Total Maximum : 10KHz Input Circuits Accepts most sine, logic and proximity switch inputs, Current Pulses, Meter factor Range 0.000001 to 1000 Non-Linear Correction Up to 10 correction points 4-20mA Inputs Input Types Flow (2 ranges), pressure and temperature Input Impedance 250 ohms Measurement Range Pressure: 0 kpa abs to 100,000 kpa abs Temperature: -273 C(-459.4 F) to 1200 C (2192 F) Flow : 999,999 Accuracy : 0.1% Non-Linear Correction A 20 point curve can be applied to the flow input RTD Input Type Platinum PT100 4Wire or 2,3Wire Range -100 C (-148 F) to 300 C (572 F). (Note a wider temperature range can be handled via a 4-20mA input.) Accuracy 0.1 C Linearity Internally compensated Pulse Output Corrected Pulse Pulse Width 10,100, 250, 500ms (negative going pulse) Duty Cycle 50 pulses/sec. max. Uncorrected Pulse Specification of the output is the same as the input. Output Open collector transistor will sink 50mA max. (Note: Suitable for driving remote counters or PLC s.) Current Pulse. ( Only Corrected pulse. ) 4-20mA Output Function Output flow rate in calculated volume, mass and Energy. The 4-20mA Point Resolution 12 Bits Accuracy Better than 0.1% Maximum Load 600 ohms internally powered. Isolation Output is isolated 3

RS232/422/485 Type Both RS232 and RS422 are provided. (Note: When using the RS422, multi-point communication (RS485) can be implemented with up to 32 instruments connected to a common bus.) Function Printer and computer protocols are fully programmable Printer A print is initiated on each reset or at a programmable time interval. (Note: Protocols are provided for roll & column printers.) Computer An ASCII based protocol enables all displayed parameters to be read and the totals to be reset Baud Rate : 300 to 19200 Data Bits : 7 or 8 Parity : None, Odd or Even Protocol ASCII, MODBUS RTU, MODBUS ASCII Data Logging Output generated at intervals of once a minute to once every 24 hours. The totals can be programmed to reset on each print or at 24:00 hours Time A real time clock is provided to give time and date on each output Relay Ouput Maximum Swiching Power : 1250VA Maximum Swiching Voltage : 250VAC, 30VDC Maximum Swiching Current : 5Amps Options SD Card 2-64GB Potable Data memory Ethernet 10/100 Base-T Ethernet TCP, UDP, IP, ARP, ICMP, MAC, DHCP WiFi IEEE802.11/b/g/n Compatible CDMA External Module(BSM865) Approvals CE, FCC, KC 4

Ordering Information Dimension 5