Signal types Coupler Box and PLC Box

Similar documents
Accessories Fieldbus Box

Controllers CECC Key features

B&R X67_IO_System_V3.14_E. X67 - System

SAI Active Universal Pro

On-Machine Modular I/O

Ver. 01. FnIO S-Series. Integrated Systems for the Speed and Quality

Peripheral modules for distributed automation Wrocław tel ul. Wyścigowa 38 fax w w w. a r a p n e u m a t i k.

Kollmorgen. Kollmorgen Automation Suite

General information. Display. Supply voltage. Input current

Modular controllers CECX

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Control blocks CPX-CEC- -V3

Product type designation. General information. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Cube67 - Modular I/O station

The TCMS Solution ionia Train control by duagon

Product type designation. General information. Supply voltage

I/O systems. I/O systems from Phoenix Contact are the perfect solution for control cabinet engineering Axioline F. For the control cabinet (IP20)

Absolute Encoders Multiturn

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Max. I/O units. consumption

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

FLEXIBLE AND MODULAR PROCESSOR T11 MULTI I/O MODULES. The Heart of ADwin Pro-II. All-rounder with A/D, D/A, counters, SSI and EtherCAT

KeConnect I/O modules

Communication Interfaces. Motors. Sensors (Feedback)

FIeldbus. Sense it! Connect it! Bus it! Solve it! /03

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Distributed Control I/O System ADAM-8000 Series

Controls. I/O-System 1000

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

General information. Display. Supply voltage

THYRO-S THYRO-A THYRO-AX THYRO-PX

MBM - Modular I/O system IP20

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

General information. Supply voltage

Intelligent Positioning Drive GEL 6111 CANopen, PROFIBUS DP, Ethernet etc.

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

EtherCAT Plug-in Modules

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

Data sheet CPU 115 (115-6BL02)

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Temperature Switches

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

VersaMax IP I/O Module

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Force/Displacement Measuring System

Motor controllers CMMO-ST

General information. Display. Supply voltage. Input current. Encoder supply. Output current

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

General information. Display. Supply voltage. Input current

Fieldbus slave modules w/o I/Os

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Control block CPX-CM-HPP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet CPU 013C (013-CCF0R00)

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

General information. Display. Supply voltage. Input current. Encoder supply. Output current

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

General information Engineering with Programming package. Display with display

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

HMG 11. Features. Optional Additional incremental output (TTL / HTL) HMG 11. Technical data - mechanical design. Technical data - electrical ratings

L-force Controls Controller-based Automation. Single loop and feedback control, visualisation

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

LMC078CECS20T motion controller LMC078-20DIO transistor sercos compact Ethernet Canopen 24Vdc

LT : Suitable platforms for harsh environments

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

170 ADI VDC - 16 Pt. Discrete Input Module Base

KL4001, KL4002 and KL4004

Submittal Data Sheet WAGO Node for itm

Data sheet VIPA CPU 115DP (115-6BL22)

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

MC800 Universal Motion Controller

TB20. DISTRIBUTED FIELDBUS I/O SYSTEM

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Remote I/O Modules EH-RIO2 Series

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

Temperature module. 4 inputs for thermocouples

Transcription:

Signal types Coupler ox and PLC ox Fieldbus interface (connection depends on the particular fieldbus) Fieldbus status display Hinged inspection window Address selection switch and diagnostic interface Module or IP-Link status display IP-Link interface for the connection of extension modules Signal connection 8 Signal status display Status display power supply: box supply and auxiliary voltage Power supply input box supply auxiliary voltage Power supply downstream connection For further information on the individual fieldbuses see page Mounting holes

Signal connections Standard housing XXL housing Connector 8 mm, snap type, -pin Connector M8, screw type, -pin Connector M, screw type, -pin Coupler ox to extension modules, spaced up to metres apart, can be connected to one Coupler ox. The Coupler ox modules are capable of automatically recognising the extension modules connected to them during startup, and map the I/O data automatically into the fieldbus process image it is not necessary to configure them. The coupler appears, from the fieldbus point of view, along with all of the networked extension modules, as a single participating bus device with a corresponding number of I/O signals. The Coupler ox corresponds to the us Coupler in the eckhoff us Terminal system. eckhoff fieldbus devices with protection class IP (us Terminals) and IP () can be combined without difficulty the data is handled in the same way in either case. Low-priced plug connectors with protection class IP can be used for the rapid and simple preparation of the IP-Link fibre optic cable. The connection does not require special tools and can be performed quickly and simply. The IP-Link cables can also be obtained with prepared plugs if required. www.beckhoff.com/coupler-ox www.beckhoff.com/plc-ox PLC ox Almost unlimited I/O application possibilities result from the extendable Coupler ox with PLC functionality and IP-Link. to extension modules, with 9 I/Os, can be directly addressed from the PLC program. The programmable PLC ox modules are therefore particularly suitable as autonomous small PLCs for the control of parts of a plant or of small machines. Programming is carried out with TwinCAT in accordance with IEC -. Five different manufacturer independent programming languages are available: Instruction List (IL), Function lock Diagram (FD), Ladder Diagram (LD), Sequential Function Chart (SFC) and the high-level language Structured Text (ST). The program download occurs either via the fieldbus or via the programming interface. Extensive debugging functions (breakpoint, single step, monitoring, etc.) are also available. Coupler ox ILy-zzz PLC ox ILy-Czzz = EtherCAT = Lightbus /8 = PROFIUS = Interbus /8 = CANopen /8 = DeviceNet = Modbus 8 = RS8 8 = RS 9/9 = Ethernet TCP/IP 9 = PROFINET 9 = Ethernet/IP = connector 8 mm, snap type, -pin = connector M8, screw type, -pin = connector M, screw type, -pin /8 = PROFIUS 8 = RS 9 = Ethernet TCP/IP = connector 8 mm, snap type, -pin = connector M8, screw type, -pin = connector M, screw type, -pin 9

Coupler ox ILx-xxx Coupler ox Digital combi, V DC x digital input + x digital output, V DC, 8 mm, IMAX =. A x digital input + x digital output, V DC, M8, IMAX =. A x digital input + x digital output, V DC, M, IMAX =. A Technical data IL-xxx IL-xxx IL-xxx Connection technology 8 mm, snap type M8, screw type M, screw type Specification EN -, type EN -, type EN -, type Number of channels inputs + outputs inputs + outputs inputs + outputs Input filter. ms. ms. ms -wire -wire -wire -wire A A -wire -wire The IL Coupler ox module combines handle load currents of up to. A, are connected via 8 mm snap type The IL Coupler ox module combines four digital inputs and four digital outputs in one device. The outputs handle load currents of up to. A, are short-circuit-proof and protected against inverse polarity. The signals are connected via M8 screw type The IL Coupler ox module combines handle load currents of up to. A, are connected via M screw type Nominal voltage V DC (- %/+ %) V DC (- %/+ %) V DC (- %/+ %) Sensor supply max.. A total, short-circuit-proof max.. A total, short-circuit-proof max.. A total, short-circuit-proof Max. output current. A on each channel,. A on each channel,. A on each channel, Load type ohmic, inductive, lamp load ohmic, inductive, lamp load ohmic, inductive, lamp load Short circuit current typ.. A typ.. A typ.. A Auxiliary power current typ. ma typ. ma typ. ma Current consumption see documentation see documentation see documentation from US Special features IP-Link coupler IP-Link coupler IP-Link coupler Approvals CE, UL CE, UL CE, UL Further information www.beckhoff.com/il-xxx www.beckhoff.com/il-xxx www.beckhoff.com/il-xxx

IExxxx Coupler ox Extension ox to Extension ox modules can be connected to the Coupler ox via the IP-Link communication facility. The Extension ox modules cover the full spectrum of I/O signals with various connection techniques. See page IExxxx Extension ox Plug Page Digital input IE Extension ox, 8 digital inputs V DC,. ms filter 8 mm 8 IE Extension ox, 8 digital inputs V DC,. ms filter M8 9 IE Extension ox, 8 digital inputs V DC,. ms filter M 9 IE Extension ox, 8 digital inputs V DC,. ms filter 8 mm 8 IE Extension ox, 8 digital inputs V DC,. ms filter M8 9 IE Extension ox, 8 digital inputs V DC,. ms filter M 9 IE Extension ox, up/down counter, V DC, khz M 9 Digital output IE Extension ox, 8 digital outputs V DC, IMAX =. A 8 mm IE Extension ox, 8 digital outputs V DC, IMAX =. A M8 IE Extension ox, 8 digital outputs V DC, IMAX =. A M IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M IE88 Extension ox, digital outputs V DC, IMAX =. A ( A) D-sub IE Extension ox, digital pulse width outputs V DC, IMAX =. A M Digital combi IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX =. A 8 mm IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX =. A M8 IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX =. A M IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX =. A 8 mm IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX =. A M8 IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX =. A M IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX = A ( A) M IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX = A ( A) M IE Extension ox, digital combination inputs/outputs V DC, ms filter, IMAX =. A 8 mm IE Extension ox, digital combination inputs/outputs V DC, ms filter, IMAX =. A M8 IE Extension ox, digital combination inputs/outputs V DC, ms filter, IMAX =. A IP connector Analog input IE Extension ox, differential analog inputs ± V, bit M 8 IE Extension ox, differential analog inputs / ma, bit M 9 IE Extension ox, analog inputs for resistance thermometer, PT, Ni, bit M 9 IE Extension ox, analog inputs for thermocouple, types J, K, L,, E, N, R, S, T, U, bit M 9 Analog output IE Extension ox, differential analog outputs / ma, bit M IE Extension ox, analog outputs ± V, bit M Special functions IE9 Extension ox, SSI encoder interface M IE9 Extension ox, incremental encoder interface with complementary inputs, MHz M IE Extension ox, serial interface RSC M IE Extension ox, serial interface, ma (TTY) M IE Extension ox, serial interface, RS, RS8 M

PLC ox ILx-Cxxx PLC ox Digital combi, V DC x digital input + x digital output, V DC, 8 mm, IMAX =. A x digital input + x digital output, V DC, M8, IMAX =. A x digital input + x digital output, V DC, M, IMAX =. A Technical data IL-Cxxx IL-Cxxx IL-Cxxx Connection technology 8 mm, snap type M8, screw type M, screw type Specification EN -, type EN -, type EN -, type Number of channels inputs + outputs inputs + outputs inputs + outputs Input filter. ms. ms. ms -wire -wire -wire -wire A A -wire -wire The IL PLC ox module combines handle load currents of up to. A, are connected via 8 mm snap type Unlike the Coupler ox, the PLC ox can be programmed via TwinCAT and thus used as a small controller. The IL PLC ox module combines handle load currents of up to. A, are connected via M8 screw type Unlike the Coupler ox, the PLC ox can be programmed via TwinCAT and thus used as a small controller. The IL PLC ox module combines handle load currents of up to. A, are connected via M screw type Unlike the Coupler ox, the PLC ox can be programmed via TwinCAT and thus used as a small controller. Nominal voltage V DC (- %/+ %) V DC (- %/+ %) V DC (- %/+ %) Sensor supply max.. A total, short-circuit-proof max.. A total, short-circuit-proof max.. A total, short-circuit-proof Max. output current. A on each channel,. A on each channel,. A on each channel, Load type ohmic, inductive, lamp load ohmic, inductive, lamp load ohmic, inductive, lamp load Short circuit current typ.. A typ.. A typ.. A Auxiliary power current typ. ma typ. ma typ. ma Current consumption see documentation see documentation see documentation from US Special features IP-Link coupler IP-Link coupler IP-Link coupler Approvals CE, UL CE, UL CE, UL Further information www.beckhoff.com/il-cxxx www.beckhoff.com/il-cxxx www.beckhoff.com/il-cxxx

ILx-Cxxx IExxxx SPS PLC ox Extension ox to Extension ox modules can be connected to the PLC ox via the IP-Link communication facility. The Extension ox modules cover the full spectrum of I/O signals with various connection techniques. See page IExxxx Extension ox Plug Page Digital input IE Extension ox, 8 digital inputs V DC,. ms filter 8 mm 8 IE Extension ox, 8 digital inputs V DC,. ms filter M8 9 IE Extension ox, 8 digital inputs V DC,. ms filter M 9 IE Extension ox, 8 digital inputs V DC,. ms filter 8 mm 8 IE Extension ox, 8 digital inputs V DC,. ms filter M8 9 IE Extension ox, 8 digital inputs V DC,. ms filter M 9 IE Extension ox, up/down counter, V DC, khz M 9 Digital output IE Extension ox, 8 digital outputs V DC, IMAX =. A 8 mm IE Extension ox, 8 digital outputs V DC, IMAX =. A M8 IE Extension ox, 8 digital outputs V DC, IMAX =. A M IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, 8 digital outputs V DC, IMAX = A ( A) M IE88 Extension ox, digital outputs V DC, IMAX =. A ( A) D-sub IE Extension ox, digital pulse width outputs V DC, IMAX =. A M Digital combi IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX =. A 8 mm IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX =. A M8 IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX =. A M IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX =. A 8 mm IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX =. A M8 IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX =. A M IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, digital inputs V DC, ms filter, digital outputs V DC, IMAX = A ( A) M IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX = A ( A) 8 mm IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX = A ( A) M8 IE Extension ox, digital inputs V DC,. ms filter, digital outputs V DC, IMAX = A ( A) M IE Extension ox, digital combination inputs/outputs V DC, ms filter, IMAX =. A 8 mm IE Extension ox, digital combination inputs/outputs V DC, ms filter, IMAX =. A M8 IE Extension ox, digital combination inputs/outputs V DC, ms filter, IMAX =. A IP connector Analog input IE Extension ox, differential analog inputs ± V, bit M 8 IE Extension ox, differential analog inputs / ma, bit M 9 IE Extension ox, analog inputs for resistance thermometer, PT, Ni, bit M 9 IE Extension ox, analog inputs for thermocouple, types J, K, L,, E, N, R, S, T, U, bit M 9 Analog output IE Extension ox, differential analog outputs / ma, bit M IE Extension ox, analog outputs ± V, bit M Special functions IE9 Extension ox, SSI encoder interface M IE9 Extension ox, incremental encoder interface with complementary inputs, MHz M IE Extension ox, serial interface RSC M IE Extension ox, serial interface, ma (TTY) M IE Extension ox, serial interface, RS, RS8 M