Supplementary Manual for Model 287a Ionizer Performance Analyzer. 287a-1/100A V1.12 P/N

Similar documents
Model 287a Ionizer Performance Analyzer

1366 INSTRUCTION MANUAL

Operators Manual Monroe Electronics, Inc. Model 288B Charge Plate Monitor P/N /100 V

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

IONIZATION SOLUTIONS

High Accuracy Gloss Meter Operation Manual. This manual is only suitable for our single angle and multi-angles gloss meters.

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Operators Manual Monroe Electronics, Inc. Model 300 Charge Plate Monitor

FG-3000R Digital Force Gauge Operation Manual

Type K/J Thermometers

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0]


DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

-auto Power Off- T1/T2/T1-T2

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

Technical manual for HP8480 Main battery switch with current monitor. + Low power output for rain light. + Battery discharge warning output.

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

FG-3000 Digital Force Gauge Operation Manual

True RMS AC Voltage/Current Datalogger

GOLD SERIES DVD/CD Duplicator Manual

PLAYBACK MODE. Blue: Manual Record. Red: White: Motion Detection Record Schedule Record

I. PANEL DESCRIPTION... 1

DPM-3221 Digital DC Power Meter with data logging capability.

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual

4-Channel Thermometer

CFM/CMM Hot-Wire Thermoanemometer

Multifunction Calibrator

NIDEC-SHIMPO INSTRUMENTS

Heavy Duty Datalogging Light Meter

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

DPM Digital DC Power Meter with Data logging capability. User Manual

Light Meter with Bar Graph

User Manual Video Borescope Model

RS Stock No Instruction Manual RS Input Data Logging Thermometer

User Manual. Thermocouple Datalogging Thermometer. Model EA15

USER MANUAL Video Particle Counter with built in Camera Model VPC300

Mini Environmental Quality Meter

4-Channel Datalogging Thermometer

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

AS Keypad User Manual

Heavy Duty Datalogging Light Meter

C F MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH HOLD TIMER T2 T1 RS-232 DC9V. h:m:m:s HUMIDITY TEMPERATURE METER POWER - UP OPTIONS

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

USB Temperature and Humidity Data Logger Instruction Manual

Series FGE-XY Force Gauges Operation Manual

EM10 TEMPERATURE / HUMIDITY /DEW POINT METER

Standard Model Digital Force Gauge ZTS series

User Manual. Borescope. Model THE STANDARD IN PRECISION MEASUREMENT

C2000 POWER METER With Data Storage

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Hand held use More precise force measurement Force-displacement measurement

NOTES TABLE OF CONTENTS

-Direct.com FG-3000 Digital Force Gauge Operation Manual

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

TC41-Thermocouple Thermometers User Manual

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

DTW 400/DTW Digital Torque Tester/Screwdriver User s Guide

ARCTIC AIR DC OLED. Digital Control Operations Manual

TEMPERATURE / HUMIDITY /DEW POINT METER

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

TA 888 Hot Wire Anemometer

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2.

FH125/FT121. Temperature / Humidity LCD Graphing Logger FH125 SET CURSOR. 1 Hour/Div 1 1 : 12 : 23 01/03/02 (ESC)


IV-18 (ИВ-18) VFD Tube Clock. Instructions. Contents. v Energy Pillar

Standard Model Digital Force Gauge ZTS series

M4-ATX-HV 6-34V Intelligent ATX Power Supply

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Installation Instructions

SATA DVD/CD Duplicator Controller User s Manual

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

SuperHeat Psychrometer Models RH350 and RH355 (kit)

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

INSTRUCTION MANUAL. Handy Polaris 2

SNMP Web Management. User s Manual

Sidewinder Pumps Inc. AC Timer/Controller

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

AFMS, Garmin G5 AML STC Rev. 1 FAA APPROVED Page 2 of 7

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

RTG-3 2-Tone RETURN PATH TEST GENERATOR

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

SecureShot HC Quick Start Instruction Page

User's Guide. Cup Thermo-Anemometer. Model AN400

Datalogging ph Meter

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

Mini Environmental Quality Meter

Datasheet: K-33 BLG Sensor

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

HANDHELD CALIBRATOR-MULTIMETER OC502-t

NIDEC-SHIMPO INSTRUMENTS

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Indoor Air Quality Meter/Datalogger

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

0.01kV (0 to ±0.99 kv)

FERGUSON BEAUREGARD. User Manual

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

Transcription:

Supplementary for Model 287a Ionizer Performance Analyzer 287a-1/100A V1.12 P/N 0345006 101107

IPA 287a Display and Operational Chart Press [On/Off] to turn on the unit ME MONROE 287a Version 1.12 Press [On/Off] or wait for 5 seconds MemUsed A30%M50% ClrData Y/N? N Press and hold [ON/OFF] between 2-4 seconds Memory used: Auto-sequence tests 30%. tests 50%. If no data in memory (I.e. A=0%M=0%), this screen is not shown. to make the choice. Then press [Enter] to select and exit. Or press [ON/OFF] for not to do anything and exit. Temperature=28C, Battery=9.0V, Humidity=34%RH longer than 4 seconds Off Set-Up Review data Press [^] or [v] : scroll through the menu [Enter] : select the menu item [ON/OFF]: back to Main Clear data RvwData A30%M50% ClrData A30%M50% ClrData N Y/N? A30%M50% See Page 2 Auto Sequence Auto Seq +++--- Auto Seq +++--- +++--- +-+-+- Test delay test duration Tst delay 5 sec Bal (Y/N) Y Bal dur 22 sec Tst delay 5 sec 0-30 sec Bal (Y/N) Y Y/N? Bal dur 22 sec 10-90 sec to scroll through the choices. Then press [Enter] to select and exit. Or press [ON/OFF] for not to do anything and exit. Auto shut down AutoShtDwn 10min AutoShtDwn 10min 0=disabl 1-15min Restore factory defaults: AutoSeq= +++--- Tst delay = 5 = Y duration= 30 sec. AutoShtDwn= 1 minute Fac. Default Exit Fac. Default N Y/N? or [ON/OFF] back to Main IPA287Supplement Page 1 Monroe Electronics, Inc.

From Page 1 M1D+ 6.8s M1TH 25C 31%RH M1D + 6.8s test Test #1 (1-0) + test time in seconds test Test #1 (1-0) Temperature Humidity M1TH 25C 31%RH M2D- 7.3s M2TH 25C 31%RH M3B+0016v -0010v M3TH 25C 31%RH M2D - 7.3s test Test #2 (1-0) - test time in seconds M3B+0012v -0003v test Test #3 (1-0) + and - Voltage peaks M4D+ 10.6s M4TH 23C 30%RH MDA+08.7s -07.3s 11D+07.3s -08.9s 12D+09.3s -06.2s 13D+20.1s -12.9s 1AD+09.3s -06.2s MDA+08.7s -07.3s Averages + and - averages 11D+07.3s -08.9s AutoSeq. group #1 (1-0) Test #1 (1-3) test + and - decay time in seconds 1AD+09.3s -06.2s AutoSeq. group #1 (1-0) Average + and - decay average of the group 1Ba+0017v -0005v 1TH 25C 30%RH AutoSeq. group #1 (1-0) test + and - voltage peaks or [ON/OFF] back to Main 1Ba+0017v -0005v IPA287Supplement Page 2 Monroe Electronics, Inc.

Plus Test (press [^] button ) The 287 unit will start by zeroing then Charge to over +1050V, then. The decay timer starts at +1000V and stops at +100V. Test (press and hold [^] or [v] button for 2-4 seconds) The 287 will start by zeroing, then for the time duration. Start recording Min and Max voltage levels after 5 seconds. Up to 10 test results can be stored in memory. They are named M1 thru M0 where M0 is the 10 th test. Press [+] and hold longer than 4 seconds + between 2-4 seconds + 950V +Charge +1030V + + 800V 3.6s Test #1 (1-0) + Timer starts at 1000V and stops at 100V 28C 9.0V 34% M2B + 1V 5.2s +0002mx 0004mn Test #2 (1-0) will abort any on-going test. After the test complete, review data begins. will scroll through the data. or [ON/OFF] back to Main Voltage update duration timer Min and Max voltages start recording after 5 seconds. IPA287Supplement Page 3 Monroe Electronics, Inc.

Minus Test (press [v] button ) The 287 unit will start by zeroing then Charge to over +1050V, then. The decay timer starts at +1000V and stops at +100V. Test (press and hold [^] or [v] button for 2-4 seconds) The 287 will start by zeroing, then for the time duration. Start recording Min and Max peaks after 5 seconds. Press [-] and hold longer than 4 seconds - between 2-4 seconds - 950V -Charge -1030V - - 800V 3.6s Test #3 (1-0) - 28C 9.0V 34% M4B +1V 5.2s +0002mx 0004mn Test #4 (1-0) will abort any on going test. After the test complete, review data begins. will scroll through the data. or [ON/OFF] back to Main Voltage update duration timer min and max voltages start recording after 5 seconds. Timer starts at 1000V and stops at 100V IPA287Supplement Page 4 Monroe Electronics, Inc.

Auto Sequence Group Test (press [AUTO] button ) The 287 unit will perform up to 10 groups of automatic test sequences and store the results in memory. Groups are named 1 thru 0 where 0 is the 10 th. Each group has 3 +decay, 3-decay, and an optional balance test. The sequence can be set in the Set-Up Menu. test : Zeroing to <5V, Charge to over +/-1050V, then. The decay timer starts at +/-1000V and stops at +/-100V. Test: Zeroing to <5V, then for the time duration. Start recording Voltage peaks after 5 seconds. The delay time between the tests can be set in the Set-Up Menu. Auto Sequence Test Press [AUTO] and hold longer than 2 seconds AUTO + 950V +Charge Group #1 (1-0) Test #1 (1-3) + +1030V + + 800V 3.6s + 20V 8.6s Delay 6 sec go on for the other 5 decay tests... Timer starts at 1000V and stops at 100V. 28C 9.0V 34% 1Ba + 1V 5.2s +0002mx 0004mn Review test results Group #1 (1-0) test Voltage update duration timer Max and min voltages start recording after 5 seconds. will abort any on going test and back to Main. After the test complete, review data begins. will scroll through the data. or [ON/OFF] back to Main IPA287Supplement Page 5 Monroe Electronics, Inc.

Error Messages What to do... Battery Low 6.2V Off in 5 sec. Change the battery. 28C 9.0V Er%RH Humidity is out of 10% - 90% range or sensor failure. If sensor failure, contact factory for repair. +1012V +Charge Unable to charge Unable to charge to 1050V. Make sure nothing is contacting the charge plate and the standoffs underneath are clean. This may also be caused by too much load on the plate. Press enter to return to the main screen. Remove the 287 from the ionizer and recheck. If problem persists contact the manufacturer for calibration. + 216V 200.s failed time out at 200 seconds, and the plate reading is still above 100V. Check your ionizer. Recommend using Monroe Model 288 EEProm Fail Contact factory. IPA287Supplement Page 6 Monroe Electronics, Inc.