F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

Similar documents
F280XD Fiber-Optic RS-232 Modem Technical Manual

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

F271XA Fiber-Optic Telephone Modem Technical Manual

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

SG Port 10/100/1000Base Switch with (8) 1000Base SFP Slots

HD-CVI / AHD / HD-TVI Video + Bi-Directional Data

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

HDMI VIDEO SYSTEM USER S MANUAL

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

DATA CONNECT ENTERPRISE

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Enhanced Mini-Chansim Model VCS-232

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DATA CONNECT ENTERPRISE

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

ADAM Fiber Optic to RS-232/422/485 Converter

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

Storage/Control I/O Module

Conitel ASYNC Adapter

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

Industrial Media Converters

XC300 VDSL Network Extender Owners Manual

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

SyncLink GT Serial Adapter

TC1540. RS-232/RS-422/RS-485 FIBER OPTIC MODEM User's Manual

Optimux-34, Optimux-25

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Data Broadcast Switch

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

E1/T1 Rate Converters

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

FD141CV-C-1. Installation and Operation Manual. 14 Widescreen HD Display. Revision Date: 05/04/2017 Page 1 of 15. Rev: B

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

4800 Series FIBER OPTIC DVI EXTENSION SYSTEM

Overview of the Cisco 2524 and Cisco 2525 Routers

iconverter 2-Module Power Chassis

INSTRUCTION MANUAL FOR MODEL IOC537 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

FOMi-40 Fiber Optic Modem with Remote Management

An ISO-9001 Certified Company

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

SIU-218 and SIU-2218

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Miniature Asynchronous 4-Wire High Speed Modems

Media Converters. Media Converters. Product Selection Guides

PSA200 User s Manual

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

FiberLink 5002 Series

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

This revision of the manual is dated June, All modifications from previous versions are listed in the appendix.

10G SFP+ Checker 2012 VER B. Page 1 of 9 3F-5, No. 30 Taiyuan Street, Chupei City, Hsinchu County 302, Taiwan

Perle SMI Media Converter Installation Guide

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

Product Overview. Interface Converters and Plug-in Modules

Commercial-grade Interface Converter User Manual

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

USER MANUAL. MODEL 1082 and 1082/144 idsl Modem with V.35 or X.21 Interface. An ISO-9001 Certified Company

FLD2SA-1S FLD2SA-2S Manual

Integrated Stepper Drive & Motor

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

ZM24x Quick-Connect Industrial Modem. User s Manual

CHAPTER 2 CHAPTER 1 INTRODUCTION

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

Meridian 1 Fiber Remote Multi-IPE Interface Description, installation, and maintenance

Gigabit Ethernet Fiber Media Converter - Compact - 850nm MM LC - 550m

Technical Specification. for. 10 Gbps SFP+ Checker

OPERATION MANUAL SMARTLAB USB LAB KITS

MEDIA CONVERTERS AND CHASSIS

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

SCADA Point-to-Point Multiplexer

Optimux-34 Fiber Optic Multiplexer

RS-232 SERIAL INTERFACE PHOTOELECTRIC ISOLATOR

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

Transcription:

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD-188-114 Modem Technical Manual Revision C October 2013 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com

PROPRIETARY DATA All data in this manual is proprietary and may not be disclosed, used or duplicated, for procurement or manufacturing purposes, without prior written permission by VERSITRON. VERSITRON LIFETIME WARRANTY All VERSITRON products are covered by a Lifetime Warranty against defects in materials and workmanship. This coverage is applicable to the original purchaser and is not transferable. We repair, or at our option, replace parts/products that, during normal usage and operation, are proven to be defective during the time you own the products, provided that said products and parts are still manufactured and/or available. Such repair/replacement is subsequent to receipt of your product at our facility and our diagnostic evaluation and review of the unit. Advance replacements are not provided as part of the warranty coverage. This warranty does not cover damage to products caused by misuse, mishandling, power surges, accident, improper installation, neglect, alteration, improper maintenance, or other causes which are not normal and customary applications of the products and for which they were not intended. No other warranty is expressed or implied, and VERSITRON is not liable for direct, indirect, incidental or consequential damages or losses. In the unlikely event a warranty issue should arise, simply contact us at 302-894-0699 or 1-800-537-2296 or via email at fiberlink@versitron.com to obtain a Return Material Authorization (RMA) number, along with instructions for returning your product. 2 www.versitron.com

1 DESCRIPTION OF EQUIPMENT 1.1 INTRODUCTION This manual provides general and detailed information on the installation and operation of Model F2238A and F2245A FOM II Series RS-530 High-Speed Fiber Optic Modems. Section 1 contains a general description of the equipment. Section 2 contains installation instructions. Section 3 contains operating instructions. Section 4 provides the theory of operation. Section 5 contains maintenance and troubleshooting information. Figure 1 and Figure 2 show front and rear views of these modems. Figure 1: Front View Figure 2: Rear View 1.2 DESCRIPTION OF EQUIPMENT 1.2.1 Functional Characteristics Model F2238A and F2245A modems are high-speed modems that allow the full duplex transmission of data, clock and a control signal (data terminal ready (DTR), data set ready/data carrier detect (DSR/DCD)) over fiber optic cable. Table 4 shows the modem link configuration. The fiber circuit consists of two modems connected by two fiber optic strands with data rates and electrical signal characteristics that conform to EIA RS-530 and MIL-STD-188-114 balanced/unbalanced standards. The modems provide synchronous or asynchronous data 3 www.versitron.com

transmission at speeds up to 10 Mbps. The link is fully transparent in both directions and is data agile. The F2238A is for use with muti-mode fiber and utilizes and 850nm SFP fiber optic module with LC connectors. The F2245A is for use with single-mode fiber and utilizes a 1310nm SFP fiber optic module with LC connectors. Basically, model F2238A and F2245A modems operate as two channel multiplexers/modems. For high-speed synchronous operation the first channel is used for data and the second for transmit clock. The data channel may be used for data in lowspeed, asynchronous operation at less than 100 Kbps. 1.2.2 Physical Characteristics Model F2238A and F2245A modems measure 7 x 1 x 11 in. WxHxL (17.8 x 2.5 x 27.9 cm). They are designed to be mounted in VERSITRON s FOM II Series HF enclosures and chassis (see Table 1). Model HF-1 (single card) desktop enclosures are available for standalone applications. Standard 19" rack mountable options include models HF-2SS (2-slot) and HF-20A (20-slot) chassis. Each modem installed in models HF-1 or HF-2SS requires its own VAC to VDC power adapter. Each power adapter uses the onepin connector on the back of the modem for power input. (Customer provided power may be supplied to the modem using the same one-pin connector.) When installed into the HF- 20A chassis model AC300WR power supply is used to provide power to the chassis and to the modems. Power is provided from the AC300WR power supply to the HF-20A chassis via model HF-CA3 power interface cable where it is then distributed to any FOM II Series modem installed in the chassis. Power redundancy is included with the AC300WR power supply with two separate AC input cables provided for power input from separate VAC sources. The RS-530 copper interface is a female DB25 connector and is located on the back of the modem. The fiber optic interface, also located on the back of the modem, consists of an SFP cage which is populated with an SFP fiber optic module. Model F2238A and F2245A Modems have seven indicator LEDs (see Figure 1): power on (PWR), alarm indicator (ALM), transmit data present (TXD), receive data present (RXD), transmit clock present (TXC), receive clock present (RXC), and loop-back indicator (LOOP). 4 www.versitron.com

Table 1: Dimensions of Enclosures and Chassis Model # (Part #) Dimensions Description Power Supply Required*¹ HF-1 (19052) 1.3" H x 7.1" W x 11.6" D (3.3 x 18.0 x 29.5 cm) HF2-SS 1.7" H x 19.0" W x 13.8" D (19629) (4.3 x 48.0 x 35.0 cm) HF-20A 7.0" H x 19.0" W x 11.6" D (32406) (17.8 x 48.0 x 29.5 cm) *¹ Note: US Model PSAC08; European Model PSAC09 *² Note: One Power Supply per Modem required. Single Card Desktop Enclosure Dual Card Rack-Mount Chassis*² (Side-by-Side) 20 Card Rack-Mount Chassis PSAC08 PSAC09 (LTWPD1220PLX) (LTWPD1220EPL) PSAC08 PSAC09 (LTWPD1220PLX) (LTWPD1220EPL) AC300WR (19320-03) 1.3 Modem Specification: 1.3.1 General Specifications: Models Dimensions Weight Operating Temperature Humidity Altitude F2238A and F2245A (7 H x 7/8 W x 11 L) (17.8 x 2.1 x 27.9 cm) 0.28 kg (10.0 oz) 0 to 50 C (32 to 100 F) Up to 95% relative humidity (non-condensing) Up to 10,000 ft 1.3.2 Electrical Interface: Models Power Requirements Data Connector Data Signal Data Rate DCE/DTE Options F2238A and F2245A 12VDC, 1.0Amp DB25, 25-pin female EIA 530/MIL-STD-188-114 20bps to 10Mbps, Synchronous 20bps to 100kbps, Asynchronous Switch Selectable 1.3.3 Fiber-Optic Interface: F2238A: multi-mode 850nm LC connectors, 2km. F2245A: single-mode 1310nm LC connectors, 10km. 1.3.4 Major Features: EIA-530/MIL-STD-188-114 balanced operation. 5 www.versitron.com

Switch Selectable DCE or DTE operation. Compatible with F2238 and F2245 modems 6 www.versitron.com

2 INSTALLATION 2.1 GENERAL This section contains detailed information on the installation and initial checkout of the F2238A and F2245A EIA-530 Modem. Section 2.2 contains general information on site selection and mounting. Section 2.3 contains the description for selecting different options on the Modem. Sections 2.4 and 2.5 contain detailed instructions for connecting Model F2238A and F2245A products to your system. Section 2.6 contains initial checkout procedures. 2.2 SITE SELECTION AND MOUNTING The Model F2238A and F2245A products are designed to be used as an interface extender for EIA-530 and MIL-STD-188-114 standard protocols. When connecting the F2238A and F2245A to a DCE or DTE device, the copper and fiber-optic cable should be securely installed so as to prevent accidental disconnection. Care should be taken to ensure that the copper and fiberoptic cables are not mechanically separated from the Modem during operation. When installed in either desktop chassis or in the dual-card rack-mount chassis, space for the power transformer must also be provided. 2.3 SWITCH AND JUMPER SETTINGS There are ten switches provided for configuration of selectable options. Switch locations are shown in Figure 3. Switch settings are as follows: 2.3.1 Modem Configuration Settings 7 www.versitron.com

Table 2: S1 Switch Settings Position On Off S1-1 DCE DTE S1-2 Force Clock (see S1-3 position) Auto Clock S1-3 Force Async operation or Force Sync Clock Forces Sync < 100kbps S1-4 Forced Sync < 100kbps Normal setting S1-5 Inverted Clock Non-inverted Clock S1-6 Inverted Data Non-inverted Data S1-7 Force DSR/DTR asserted DSR/DTR Control Optic Link S1-8 Factory setting* * Note: Factory setting for the marked S1 positions as indicated by *. Do Not Change. Table 3: S2 to S9 Switch Settings Position On Off S2 DCE DTE S3 DCE DTE S4 DCE DTE S5 DCE DTE S6 DCE DTE S7 DCE DTE S8 DCE DTE S9 DCE DTE Note: All switches must be set to the same configuration. All 'ON' or all 'OFF'. On the switch the dot indicates the 'ON' position. The switch SW10 is located on the front panel of the modem. This switch enables a local loop of all modem circuitry before the fiber-optic module when in the on position. The loop indicator will be illuminated when this switch is in the ON position. Note: The ALM indicator with be illuminated when the loop switch is enabled. 8 www.versitron.com

Figure 3: Switch and Connector Locations 2.4 POWER REQUIREMENTS The F2238A and F2245A products are designed to operate from an AC power transformer or a DC power source in the range of +10 to +16 VDC. 2.4.1 Installation with AC Power Before inserting the VERSITRON power transformer, PSAC08 (US) or PSAC09 (EUR), into an AC power source, the plug should be connected to the Modem. There are no special tools required. 2.4.2 Installation with DC Power DC power may be used instead of a power transformer. This requires a 2.5 mm socket, J3 9 www.versitron.com

(location shown in Figure 3) with the positive voltage on the center and the common on the concentric supplying 12VDC at 1.0A as shown below (Figure 4): Figure 4: DC Power Supply Connection 2.5 INTERFACE WIRING Table 4 and Table 5 list the interface wiring for the F2238A and F2245A Modems. A female DB25 connector is used as shown in Table 4. The modular connector (J3) is wired in parallel with the 12-pin connector (P1) for power. When installing the modem in a standalone or dual-card rack-mount chassis, a power transformer is plugged into modular jack (J3). When installing the F2238A and F2245A Modems in a 20-card rack-mount chassis (HF20A) with optional power supplies (AC300WR) the 12-pin connector (P1) is used. Wiring for the 12-pin connector is shown in Table 5. Illustration 3 identifies the locations for the 12-pin power connector (P1) and modular power jack (J3). 10 www.versitron.com

Table 4: F2238A and F2245A Data Interface Receive Data (A) < 3 3 < Transmit Data (A) Receive Data (B) < 16 16 < Transmit Data (B) Receive Clock (A) < 17 17 < Terminal Timing (A) Receive Clock (B) < 9 9 < Terminal Timing (B) Transmit Data (A) > 2 2 > Receive Data (A) Transmit Data (B) > 14 14 > Receive Data (B) Terminal Timing (A) > 24 24 > Receive Clock (A) Terminal Timing (B) > 11 < > 11 > Receive Clock (B) Signal Ground < > 7 Fiber cable 7 < > Signal Ground Data Set Ready (A)* < 6 20 > Data Set Ready (A)* Data Set Ready(B)* < 22 23 > Data Set Ready (B)* Data Terminal Ready (A)** > 20 6 < Data Terminal Ready (A)** Data Terminal Ready (B)** > 23 22 < Data Terminal Ready (B)** Carrier Detect (A)* < 8 8 < Carrier Detect (A)* Carrier Detect (B)* < 10 10 < Carrier Detect (B)* Frame Ground < > 1 1 < > Frame Ground LOCAL MODEM DCE DTE REMOTE MODEM * Produced by local modem, not received from remote modem. ** Signal not physically passed, used to control signal flow through local modem. Table 5: (P1) Chassis Power/Alarm Wiring Pin Number Signal Designation 1 +12 VDC 2 +12VDC 3 Signal Ground 4 Signal Ground 5 Signal Ground 6 Frame Ground (Chassis) 7 System Alarm Interface 8 Signal Ground 9 Signal Ground 10 +12 VDC 11 +12 VDC 12 +12 VDC 2.5.1 Fiber-Optic Cable Installation After the electrical and digital interface cables have been wired according to sections 2.4 11 www.versitron.com

and 2.5, make sure the SFP module is firmly seated into the SFP cage (Z1) and attach the fiberoptic cable to it (see Figure 3 for location of Z1). The SFP module slides into the RFI Cage label side up. There will be a slight click when it locks into place. After the SFP module is installed the fiber-optic cable can be installed. The cable must be an LC type connection. The cable should be oriented with the thumb tab at the top, when completely inserted the tabs will click into place. 2.6 INITIAL CHECKOUT PROCEDURE F2238A and F2245A Modems contain no power on/off switch. Once power is connected the modem will go through its power-up sequence, when the Power LED (see Figure 1) is lit the modem is ready for use. Before beginning system operation check the following to verify proper installation: 1. Verify that the power plug is seated fully into the modem or the modem is seated fully in the rack-mount enclosure (HF20A). 2. Verify that the fiber cable is connected on each end. 3. Verify that the Alarm LED (see Figure 1) is not lit when the fiber-optic cable is connected and the units, both local and remote, are powered. DSR/DTR must be asserted or forced via S1-7. If a malfunction is detected during the initial checkout procedure, refer to Section 5 for information on isolating the malfunction in the unit. 12 www.versitron.com

3 OPERATION 3.1 INTRODUCTION This chapter contains a description of the operating controls and indicators associated with the F2238A and F2245A Modems. Since the F2238A and F2245A are designed for continuous and uninterrupted operation, there are no setting requirements after the unit is operational. Once the Modem is powered up it should remain in service as long as required. 3.2 STATUS INDICATORS There are 7 indicators on the F2238A and F2245A: Power Status(Power), Alarm, Transmit Data(TXD), Receive Data(RXD), Transmit Clock(TXC), Receive Clock(RXC), and Loopback(LOOP) (see Table 6 for descriptions). Table 6: Status Indicators LEDs* Color Function Power Green Indicates the modem is powered and ready for use. Alarm Red Indicates no fiber-optic link with remote end when lit. TXD Yellow Indicates transmit data RXD Yellow Indicates receive data TXC Yellow Indicates transmit clock RXC Yellow Indicates receive clock. Loop Red Indicates local loopback just before fiber-optic module * See Figure 1 for LED mapping 13 www.versitron.com

4 THEORY OF OPERATION 4.1 INTRODUCTION The F2238A and F2245A are EIA-530/MIL-STD-188-114 standard modems which can be configured as either Data Communications Equipment (DCE) or Data Terminal Equipment (DTE). These modems are designed to be used in pairs as a transparent interface extension over a fiber-optic link. These units are housed in VERSITRON FOM II chassis: HF1, HF2SS and HF20A. Chassis descriptions are found in section 1.2.2. 4.2 POWER SUPPLY AND ALARM CIRCUITRY 4.2.1 Power Supply Circuit When 12VDC is applied to the circuit, the unit should draw approximately 100mA. The unit has a switching power supply circuit, which converts 12V to 3.3VDC, and 1.2VDC.. 4.2.2 Alarm Circuit This unit does not have an alarm circuit. Therefore, the Alarm signal on the AC300WR will not be driven by this unit. 4.3 FUNCTIONAL DESCRIPTION The unit consists of the following circuits: 4.3.1 - Logic Conversion 4.3.2 - FPGA (Mux/Demux) 4.3.3 - Fiber-Optic Transceiver Circuit 4.3.1 Logic Conversion There is a transceiver chipset that converts the EIA-530 interface signals to logic level signals for processing and transmission over the fiber-optic link. 4.3.2 FPGA (Mux/Demux) 14 www.versitron.com

The FPGA is used to multiplex/demultiplex the RS interface signals from the chipset for transmission over the fiber-optic link. The FPGA is a proprietary VERSITRON design that provides serial conversion and synchronization of the EIA-530 interface signals on the fiber-optic link. 4.3.3 Fiber-Optic Transceiver Circuit Fiber-optic communications are handled by the SFP module. The power for this module is isolated from the other power circuits through filters. This helps reduce the supply noise being coupled into the SFP module. The SFP interfaces directly with the FPGA. 15 www.versitron.com

5 MAINTENANCE AND TROUBLESHOOTING 5.1 INTRODUCTION This chapter contains general information designed to isolate a malfunction in the Models F2238A and F2245A to a replaceable unit. These units are not equipped with redundancy. Therefore, a failure in one of these units will interrupt service. 5.2 FAULT ISOLATION The steps in Table 7 should be taken to check a non-operating modem. Contact VERSITRON Customer Service for additional diagnostic assistance or to arrange for repair as necessary. Table 7: Non-Operational Indicators STATUS INDICATOR PROBABLE CAUSE CORRECTIVE ACTION Power LED is OFF No AC power Check that both ends of the transformer are connected Alarm LED is ON Modem is not working properly Other Incorrect optical signal level received at receiver input Default switch settings are not set properly Contact VERSITRON for assistance 1. Check that fiber-optic cables are properly connected 2. Check that the remote unit power is on and the fiber-optic connectors are properly attached 3. Check that the SFP module on each end is seated properly 4. Contact VERSITRON for assistance 1. Check if S1 positions are set properly 2. Check if S2-S9 are set properly 3. Contact VERSITRON for assistance 16 www.versitron.com