PT35. Dual Pulse Timer Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

Similar documents
PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

User Guide. Control Box. RoscoLED TM.

INSTRUCTION MANUAL. AquiStar GDL. Dissolved Oxygen Datalogger

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. ZIG-NANO Wireless Transmitter. Installation Maintenance Repair Manual CONNECTED ON:01

Aqua4Plus 2.0. Control Software for LevelSCOUT, BaroSCOUT, PT2X, CT2X PROUDLY MADE IN THE USA

zpen-1080p Features zpen-1080p Layout

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

SECURE/NONSECURE LED SIGN USER MANUAL

Global Water Instrumentation, Inc.

Model A7BS

PSA200 User s Manual

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Sonic Ruptor 400. User Manual

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

INSTRUCTION MANUAL. Reading. AquiStar Smart Sensors. With an INW Panel Meter

Turbo. Tubidity Smart Sensor with Data Logging ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

CA-A480-A Elevator Controller. Reference & Installation Manual

SD1306. Speed Dome IP Camera. Quick User Guide

Zonit μats TM Users Guide μats1-lv Version 1.2

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at

AEXX-349 SERIES REMOTE DISPLAYS

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

Turbo. Tubidity Smart Sensor with Data Logging ISO USA. Precision Environmental Sensors An ONICON Brand PROUDLY MADE IN THE

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

LPG STM 94442A User s Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Relay Board. User Manual. 1.0, Oct 2013

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

EZ-LIGHT SP Series Signal Light

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

ES-600 Ozone Controller Operation Manual

Pulse LED Instruction Guide

Remote Refrigeration Control

ETConcept Systems Engineering. User s Guide

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

PWRguard PLUS Spring City Drive Waukesha, WI

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

OZONE SWITCH Model OS-6. OS-6 Features

Instruction Sheet ICLS-COOL TM. Quiet-Cool Series Closet Cooler ICLS-COOL1 ICLS-COOL2

CMSA-100 Manual. Cinema Media Server Automation

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

QuickTouch (QT4) Owner s Manual

G2M Control Board Installation and Operations Manual

Number of input channels

CTI 2550 EIGHT CHANNEL ISOLATED ANALOG INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 2.0 CTI Part # IOG $25

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

WLC60 Heavy Duty Stainless Steel LED Light

PIM-Mini Pulsed Current Source Operation Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

FlowInspector. Software Guide for Seametrics Data Logger ISO. (DL76, Logging Meters, Rate/Total Indicators, and Flanged Magmeters) Version 2.

PCM-7140 Pulsed Current Source Operation Manual

AirPro Surveyor 2 Manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Automated Tuner System Power Distribution Hub

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

ACLD Channel Opto-isolated Digital Input Board

VIP-812A DUAL NETWORKED STATION PORT

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

Tracer VM Bluetooth Interface

Rack Power Distribution Unit AP7530, AP7540

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

I/O Expansion Box Installation & Operator s Instruction Manual

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

INW Turbo Tubidity Smart Sensor with Data Logging

V-9939B MICROPHONE ADAPTER

TSD-DA28 2x8 Balanced Line Distribution Amplifier

MPP200 User s Manual

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Digital Lighting Systems, Inc.

Plus-X AC-8. User Guide

Smart-Box Series. Electronic Lockbox User Manual. Model: 7000,

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

Global Water globalw.com. Global Water. Instrumentation, Inc.

MPP1700 User s Manual

CSM_PYF S/P2RF- -S_DS_E_2_5

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

zclock-200w User Manual

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

S82S (3/7.5-W Models)

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

MODEL No. SW1X8 RS422 SWITCHER

DCM Digital Control Modules

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

MODEL USBP-DIO16RO8. DIGITAL INPUT/OUTPUT BOARD w/8 ELECTROMECHANICAL RELAYS USER MANUAL

AE21 SERIES DISPLAY CONTROL TERMINAL

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Instruction Manual. Balanced Audio Upgrade Installation. iport IW-21/IW-22 Upgrade Kits. Balanced Audio Upgrade Kit. (iport IW-21)

XS/SC26-2 Safety Controller Quick Start Guide

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Transcription:

PT35 Dual Pulse Timer Instructions Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company

TABLE OF CONTENTS General Information General Information...Page 3 Features...Page 3 Specifications...Page 3 Installation and Connections Mounting...Page 4 Connecting the Meter...Page 4 Connector Field Installation...Page 4 PT35 Connections Diagrams...Page 4 Connecting the Load...Page 4 Connecting Power...Page 4 Setting...Page 4 Operation Possible Overlap Conditions...Page 5 Accumulator Function...Page 5 How to Determine Accumulator Setting(s)...Page 5 How to Determine TIMER (Power On Time) Setting(s)...Page 5 Troubleshooting Problem...Page 6 Probable Causes...Page 6 Things to Try...Page 6 Warranty Seametrics Limited Warranty...Page 7 Seametrics 253.872.0284 Page 2 seametrics.com

GENERAL INFORMATION The PT35 digital counter-timer is designed to be used with Seametrics (or similar) meters and flow sensors that produce a pulse signal. It is typically used in water treatment and chemical dosing applications, most often in cooling towers and boilers. The PT35 serves as either a single or a dual timer, depending on whether one or both of its independent accumulators and timed outputs are used. In single timer applications, one accumulator counts pulses coming from the meter. When a pre-set number of pulses has been reached, output power turns on for a set time, and then the cycle repeats. In dual timer applications (typically, one chemical feed and one water bleed), both accumulators and timers are set to operate independently with input from a single meter. A sequential function can be selected to lock one timer out while the other is operating. This prevents feed and bleed from occurring simultaneously. The PT35 can be used with dry contact meters (e.g. Seametrics MJR meters), contacting-head meters with solid-state pickups (e.g. Seametrics MJE meters), or insertion flow sensors (e.g. Seametrics IP, TX, and EX Series). Features Input Indicator Light Bright LED Display + visible in low light Setting Knob + increase clockwise + decrease counter-clockwise Test Buttons Force One Timed Output Easy-Off Cover Pre-Wired Outputs and Power Cord Meter Input Connector Specifications* Power Sensor Power Output (2) Enclosure Accumulator Range Timer Range Maximum Input Frequency Relay Contact Rating 115 Vac 12 Vdc, unregulated @ 20 ma max 115 Vac 5 x 7 (12.7 x 17.8 cm) polycarbonate 1 9999 pulses 1 9999 seconds 1000 Hz 5 A resistive @ 115 Vac, or 1/4 HP Temperature 32-130 F (0-55 C) Environmental NEMA 1, IP10 * Specifications subject to change. Please consult our web site for the most current data. (seametrics.com) Seametrics 253.872.0284 Page 3 seametrics.com

INSTALLATION AND CONNECTIONS Mounting Use a secure surface that will accept screws. Remove the front clear cover by use of the thumb screws to access the mounting holes at the four corners. Using the box as a template, mark the centers of the holes with a pencil and drill. Insert screws through the four corner holes and tighten. Connecting the Meter Because the PT35 comes standard with a built-in meter connector, the simplest method of connecting your Seametrics meter to the PT35 is to order a mating Seametrics connector pre-installed on your meter or flow sensor. If your meter does not have a Seametrics connector, there are three alternatives: 1) Any wire ends can be connected to the PT35 terminal block (see Connections diagram at right). 2) A cable-with-connector can be factory-ordered and field-wired to your meter. 3) A connector can be factory-ordered and field-installed on your meter output cable (see Connector Field Installation diagram below). Connector Field Installation Setting INPUT CONNECTOR 1 3 1POWER GND 2 2 INPUT SIGNAL 3 POWER OUTPUT +12Vdc BLACK WHITE RED Hall-effect or transistor switch Dry contact To Connector Pin 1 To Connector Pin 2 To Connector Pin 1 To Connector Pin 2 To Connector Pin 3 Using the thumb screws, remove the front cover. 1. Press the SET button. The green ACC (accumulator) light at the upper left corner of the display will begin blinking, indicating that the accumulator is ready to be set. 2. Turn the knob clockwise to increase or counterclockwise to decrease until the desired number of pulses is reached. 3. Press SET again. The red TIMER indicator will light. 4. Set the desired time in seconds for output power to turn on. 5. Repeat the process to set Accumulator 2 and Timer 2 as needed. PT35 Connections Diagram POWER Ground Neutral Hot 3AG-10A-SB Fuse Connecting the Load Two output cords are provided for connection of 115 Vac loads. The unit can be hard-wired if necessary, using the terminals inside. Connecting Power H V G Hot Normally Open Hot Normally Closed Neutral Ground GND SIGNAL GND SIGNAL +12 Vdc PUMP+ GND SIGNAL +12Vdc OUTPUT 2 NO NC N G DRY CONTACT TYPE METER SOLID STATE TYPE METER OUTPUT 1 NO NC N G EXTERNALLY-PACED METERING PUMP SOLID STATE TYPE METER Input Connections PT35 Ground Neutral Hot Normally Closed Hot Normally Open A power cord is provided. Connect by plugging in to any standard grounded outlet. (See Connections Diagram above for conduit connection.) 6. Press SET again to display SEq (sequential). 7. Turn the knob in either direction to switch from SEq to nseq (non-sequential). Sequential operation prevents the Timer 2 output from operating while Timer 1 is on, so that chemical feed does not occur during bleed. Non-sequential operation allows either timer to operate immediately when its count is reached. 8. Press SET again to return to normal operation. Test for Timed Output. To test the timed output(s), press the TEST 1 or TEST 2 button. The read output indicator should light and remain on for the pre-set number of seconds. P G S V Seametrics 253.872.0284 Page 4 seametrics.com

OPERATION After setting (when the unit has returned to normal operation, indicated by no blinking indicators), any display can be selected at any time by turning the knob. Turning the knob clockwise causes clockwise rotation among the indicator lights. Stop turning the knob after arriving at the desired display. This is the display that will remain until another display is selected. Possible Overlap Conditions If the power on time is longer than the time between on cycles, the on time won t elapse before the next on cycle is supposed to start. If this happens, the power output will remain on, and OUF (Overlap, Under wait time, Failure) will appear on the screen, to alert the user that a problem has occurred. This situation can be avoided by following the equation above in How To Determine TIMER (Power On Time) Setting(s). Also note that if in sequential mode, the sum of the on time, must be less than the minimum seconds between cycles. Otherwise, one relay will hold up the other and an overlap condition will occur. How To Determine TIMER (Power On Time) Setting(s) The TIMER time is set to release the desired amount of chemical to be fed or water to be bled, and is specific to the pump, valve, etc. being used. When determining the power on time, check that it isn t more than the expected time between cycles, to avoid feeding and bleeding out of order or possible overlap conditions, by calculating: Cycle Size (Gallons) Max. Flow Rate (GMP) X 60 sec Min. = minimum seconds between cycles If this result is greater than the determined power on time, enter the determined power on time into the TIMER setting. Accumulator Function The accumulator adds received pulses once every second, and when the accumulator number is reached or exceded, the power will turn on. However, any pulses above the accumulator number will not roll over to the next cycle, so if the accumulator is set to 20, with 19 pulses already having been received, and 2 more are received in the next second, the accumulator will read 0 once the power is turned on, and not 1. How to Determine Accumulator Setting(s) If the meter pulses once every gallon, set the accumulator for the number of gallons desired between timer cycles. For meters with multiple pulses per gallon, multiply the desired number of gallons by the pulses per gallon. For meters with multiple gallons between pulses, divide the desired gallons by the gallons per pulse. Example: The goal is one timer output every 60 gallons. The meter has a 5 gallons-per-pulse (G/P) output. 60 gallons 5 gallons/pulse = 12 pulses (accumulator setting) Seametrics 253.872.0284 Page 5 seametrics.com

TROUBLESHOOTING Problem Probable Causes Things to try On/Off switch is fully in on position, but display is not lighted Unit does not have power Check for power at the cord and outlet Fuse may be blown Remove front panel and check fuse. If it is blown, replace with 3AG-10A-SB fuse. Circuit board component may be bad Contact your supplier or the factory to return unit for repairs The display is lighted, but the unit seems to be functioning abnormally No input from meter Check flow, check the input indicator light (if the meter is set for low pulse rate, several minutes may pass between blinks) Unit improperly set Press the Set button to review each setting Output improperly connected to load Press the appropriate Test button to force an output and check (each Test button is located directly above the output it forces) Unit appears to be functioning properly, the test button causes the timer indicator to light, but the appropriate output does not become powered Possible relay failure Contact your supplier or the factory to return the unit for relay replacement Seametrics 253.872.0284 Page 6 seametrics.com

SEAMETRICS LIMITED WARRANTY The limited warranty set forth below is given by Seametrics, with respect to Seametrics and INW brand products purchased in the United States of America. Seametrics warrants that products manufactured by Seametrics, when delivered to you in new condition in their original containers and properly installed, shall be free from defects in material and workmanship. Seametrics products are warranted against defects for a period of two (2) years from date of installation, with proof of install date. If no proof of install date can be provided, warranty period will be two (2) years from date of shipment from Seametrics, as defined on Seametrics invoice. Seametrics obligation under this warranty shall be limited to replacing or repairing the part or parts, or, at Seametrics option, the products, which prove defective in material or workmanship. The following are the terms of Seametrics limited warranty: a. Buyer must give Seametrics prompt notice of any defect or failure and satisfactory proof thereof. b. Any defective part or parts must be returned to Seametrics factory or to an authorized service center for inspection. c. Buyer will prepay all freight charges to return any products to Seametrics factory, or another repair facility. as designated by Seametrics. d. Defective products, or parts thereof, which are returned to Seametrics and proved to be defective upon inspection, will be repaired to factory specifications. e. Seametrics will deliver repaired products or replacements for defective products to the buyer (ground freight prepaid) to the destination provided in the original order. f. Products returned to Seametrics for which Seametrics provides replacement under this warranty shall become the property of Seametrics. g. This limited warranty covers all defects encountered in normal use of Seametrics products, and does not apply to the following cases: i. Loss of or damage to Seametrics product due to abuse, mishandling, or improper packaging by buyer ii. iii. iv. Failure to follow operating, maintenance, or environmental instructions prescribed in Seametrics instruction manual Products not used for their intended purpose Alterations to the product, purposeful or accidental v. Electrical current fluctuations vi. vii. viii. ix. Corrosion due to aggressive materials not approved for your specific product Mishandling, or misapplication of Seametrics products Products or parts that are typically consumed during normal operation Use of parts or supplies (other than those sold by Seametrics) which cause damage to the products, or cause abnormally frequent service calls or service problems h. A new warranty period shall not be established for repaired or replaced material, products, or supplied. Such items shall remain under warranty only for the remainder of the warranty period on the original materials, products, or supplies. i. In the event that equipment is altered or repaired by the buyer without prior written approval by Seametrics, all warranties are void. Damage caused by equipment or accessories not manufactured by Seametrics may void the product s warranty. j. SOFTWARE: The Seller grants the user a non-exclusive license to use Seametrics software, according to the following limitations and conditions: i. The user may install the software on one or more desktop or laptop computers. ii. iii. iv. All title and intellectual rights to the software are owned by Seametrics. No copies may be made or distributed except as described above. The user may not modify or reverse-engineer the software. THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER ORAL, WRITTEN, EXPRESSED, IMPLIED OR STATUTORY. NO IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, APPLIED TO THE PRODUCTS AFTER THE APPLICABLE PERIOD OF THE EXPRESS LIMITED WARRANTY STATED ABOVE, AND NO OTHER EXPRESS WARRANTY OR GUARANTY, EXCEPT AS MENTIONED ABOVE, GIVEN BY ANY PERSON OR ENTITY WITH RESPECT TO THE PRODUCTS, SHALL BIND SEAMETRICS. SEAMETRICS SHALL NOT BE LIABLE FOR LOSS OF REVENUES, OR PROFITS, OR INCONVENIENCES, EXPENSE FOR SUBSTITUTE EQUIPMENT OR SERVICE, STORAGE CHARGES, LOSS OF DATA, OR ANY OTHER SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGE CAUSED BY THE USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS, REGARDLESS OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF SEAMETRICS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL RECOVERY OF ANY KIND AGAINST SEAMETRICS BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT SOLD BY SEAMETRICS AND CAUSING THE ALLEGED DAMAGE. WITHOUT LIMITING THE FOREGOING, YOU ASSUME ALL RISK OF LIABILITY FOR LOSS, DAMAGE, OR INJURY TO YOU AND YOUR PROPERTY AND TO OTHERS AND THEIR PROPERTY ARISING OUT OF USE OR MISUSE OF, OR INABILITY TO USE THE PRODUCTS NOT CAUSED DIRECTLY BY THE NEGLIGENCE OF SEAMETRICS. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. SIMILARLY, SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF CONSEQUENTIAL DAMAGE, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS; HOWEVER, YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. Seametrics 253.872.0284 Page 7 seametrics.com

Seametrics 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 seametrics.com LT-65200311r2.0 20180405 4/5/18