DIN-RAIL EXPANDER int-iors_en 10/14

Similar documents
1. Features. 2. Installation KNX INTEGRATION MODULE INT-KNX

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up

INT-TSG Installer Manual

INT-TSH Installer Manual

INSTALLER MANUAL. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel

INTEGRA Firmware version 1.11

Keypad INT-TSI Installer Manual

RADIO REMOTE CONTROLLER SET RE-4K

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18

Ethernet communication module ETHM-1 Plus

Ethernet Module ETHM-1

Wireless keypad PRF-LCD-WRL

INSTALLER MANUAL. Alarm Control Panels. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel

INT-KSG Keypad Quick user s guide

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

GPRS/SMS Reporting Module GPRS-T2

INSTALLER MANUAL. Alarm Control Panels. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel

GPRS-T4. GPRS/SMS Reporting Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

INT-TSI Brief User Manual

RS485 MODBUS Module 6RO

INT-KSG Keypad Quick user s guide

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

GPRS-T6. GPRS/SMS Reporting Module with Power Supply

MICRA. Alarm module with GSM/GPRS communicator. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel

ACCO. Access control modules. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel

Alarm Control Panel INSTALLER MANUAL. Firmware Version 1.07 GDAŃSK. integra-wrl_i_en 08/09

ISDN Module USER MANUAL

MODEL: R2K-1 SEN TRONIC AG. R2K Series

ACCO SOFT. Configuration program for ACCO NET access control system. User Manual

HI SEC Integrated Systems

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

MICRA. Alarm module with GSM/GPRS communicator

Connecting a Cisco Input Module

BACS_GX_R_AUX Businterface

PROGRAMMING AND INSTALLATION MANUAL

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

Keypad LCD-L (software version 3.10) CA-10 plus

Keypad LCD (software version 3.10) CA-10 plus

Connecting a Cisco Output Module

Expansion Module HZS 541-1S

2-Way Wireless I/O Expander Installation Guide

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

MCX402DR-BRD I/O expander. Operating Manual

AO 081 S-DIAS Analog Output Module

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Installation guide for PR302 v2.0 Rev. E

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Island bus expansion module

DATA SHEET IOM 200 analogue interface for AGC 200

DM 161 S-DIAS Digital Mixed Module

Industrial Media Converters

MR52 READER INTERFACE

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Temperature controller Ducted systems

EA500. Installation Instructions Transponder

IPassan Installation guide

Installation and User Guide

RXTP ROOM TEMPERATURE

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

CONVERTER FOR MONITORING STATION SMET-256

Connecting a Cisco Reader Module

TCNM-ACBB1 Installation Manual

MCT82M-IO-CH Operating Manual

PROGRAMMING. Alarm Control Panel. SATEL sp. z o.o. ul. Budowlanych Gdańsk POLAND tel Firmware Version 1.

Breadboard & Digital Input/Output Modules

RS485 MODBUS Module 8AO

ISE 021 S-DIAS Interface Module RS232 / RS485

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

RXTH DUAL ROOM SENSOR / SWITCH

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

CA-A480-A Elevator Controller. Reference & Installation Manual

TO 161 S-DIAS Digital Output Module

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

GSM-X. Communication module. Firmware version 1.00 gsm-x_en 01/18

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RFT1000 reader in RACS 5. User Manual

Compact Coded Magnetic Safety Interlock Switch and Control Units

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM

PR402 v2.0 Installer Manual Rev.C

Introduction. 1. RF Module

PR602LCD v1.0 Installer Manual Rev. A

AWARD WINNING PRODUCTS AND SERVICES TAKING OUT COST AND INCREASING OPERATING EFFICIENCY

Installation guide for PR602LCD type access controller

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

Alarm Control Panels. Firmware Version 1.04 INSTALLER MANUAL GDAŃSK. integra_i_e 07/06

16-Way Input 48-Way Output Card

Accessories and options

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Transcription:

INT-IORS INT-ORS DIN-RAIL EXPANDER int-iors_en 10/14 The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8 programmable wired outputs. The INT-ORS expander enables the system to be expanded by 8 programmable wired outputs. The modules are designed for mounting on 35 mm DIN rail, which facilitates installation process and integration with other automation systems. The expanders work with INTEGRA, INTEGRA Plus and CA-64 control panels. Additionally, the INT-ORS expander is supported by the VERSA control panel. This manual applies to the expanders with electronics version 2.1 and firmware version 2.00 (or newer). 1. Features 8 programmable hardwired zones only INT-IORS: support for NO and NC type detectors, as well as roller shutter and vibration detectors, support for Single EOL, Double EOL and Triple EOL configuration (Triple EOL when working with INTEGRA Plus control panels), programming end-of-line resistor values. 8 programmable relay outputs for control of the electrical devices supplied with 230 V AC. Capable of being integrated with dedicated power supply unit (operation in "expander with power supply" mode). Connectable to RS-485 bus (firmware update through the bus). 35 mm DIN rail mountable. 2. Specifications Supply voltage... 12 V DC ±15% Standby current consumption INT-IORS...35 ma INT-ORS...35 ma Maximum current consumption INT-IORS...350 ma INT-ORS...310 ma Relay output rating (resistive load)... 16 A / 230 V AC +12V output rating... 2,5 A / 12 V DC Environmental class according to EN50130-5... II Operating temperature range...-10 C...+55 C Maximum humidity...93±3% Dimensions...122 x 93 x 58 mm Weight INT-IORS... 300 g INT-ORS... 285 g The declaration of conformity may be consulted at www.satel.eu/ce

2 INT-IORS / INT-ORS SATEL 3. Description Explanations to Fig. 1: LED indicators of the status of individual relays (the digit between green and red LED is the number of relay output in the expander): red LED ON the relay is inactive, green LED ON the relay is active. LED indicating the status of communication with the control panel: ON no communication with the control panel, blinking communication with the control panel OK. DIP-switches (see: DIP-SWITCHES). connector for a dedicated power supply unit (e.g. APS-412). Description of terminals: NO - relay output normally open contact. C - relay output common contact. NC - relay output normally closed contact. Z1...Z8 - zones. only INT-IORS COM - common ground. +12 - +12 V DC power input / output. Do not connect power to the terminals, if the dedicated power supply unit is connected to the connector on electronics board. DAT - data (communication bus). CLK - clock (communication bus). A, B - RS-485 bus.

SATEL INT-IORS / INT-ORS 3 4. DIP-switches The DIP-switches 1-5 are used for address setting. A numerical value is assigned to each switch. In OFF position, the value is 0. Numerical values assigned to individual switches in ON position are shown in Table 1. The sum of numerical values assigned to switches 1-5 means the address set on the module. The address must be different from that on the other modules connected to the communication bus of the control panel. DIP-switch number 1 2 3 4 5 Numerical value 1 2 4 8 16 Table 1. Fig. 2 shows some examples of DIP-switches settings. The DIP-switch 10 allows you to define how the expander will be identified by the control panel (see: Table 2 for INT-IORS expander and Table 3 for INT-ORS expander). In the case of the INT-IORS expander, if the switch is set in ON position, the expander will be always identified as an expander with power supply (regardless of whether the dedicated power supply is connected to the PCB connector, or not). Functional differences resulting from identification of the INT-IORS expander are presented in Table 4. DIP-switch position DIP-switch position Identification of INT-IORS expander expander w/o power supply expander with power supply ON INT-PPPS / CA-64 PP OFF INT-IORS INT-IORSPS Table 2. Identification of INT-ORS expander expander w/o power supply expander with power supply ON INT-O / CA-64 O INT-OPS / CA-64 OPS OFF INT-ORS INT-ORSPS Table 3. Notes: The INT-IORS expander will be identified as INT-PPPS / INT-IORSPS by INTEGRA / INTEGRA Plus control panels with firmware version 1.12 or newer. The INT-ORS expander will be identified as INT-O / INT-OPS / INT-ORSPS by INTEGRA / INTEGRA Plus control panels with firmware version 1.12 or newer.

4 INT-IORS / INT-ORS SATEL The switch 10 must be set in ON position, if the expander is connected to the following control panels: CA-64; INTEGRA with firmware version from 1.00 to 1.04, inclusive. If the switch is set in OFF position, the control panel will not be able to identify the expander. If the dedicated power supply is connected to the onboard connector, you can set the switch 10 to OFF position only for the INTEGRA / INTEGRA Plus control panels with firmware version 1.12 or newer. If the dedicated power supply is not connected to the INT-IORS expander onboard connector and the expander has been identified as INT-PPPS / CA-64 PP, no power supply related troubles will be reported. INT-IORS INT-IORSPS CA-64 PP INT-PPPS support for roller shutter / vibration detectors - support for Triple EOL configuration (INTEGRA Plus) - programming end-of-line resistor values - Table 4. 5. Installation and start-up Disconnect power before making any electrical connections. The expander is designed for indoor installation. 1. Mount the expander on DIN rail (see Fig. 3) or attach it to the wall using screws (see Fig. 4). 2. Using the DIP-switches, set the suitable expander address and define how it is to be identified. 3. Connect the CLK, DAT and COM terminals to the corresponding terminals of the control panel communication bus (see: installer manual for alarm control panel). It is recommended that an unshielded non-twisted cable be used to make the connection. If you use the twisted-pair type of cable, remember that CLK (clock) and DAT (data) signals must not be sent through one pair of twisted conductors. The conductors must be run in one cable. 4. In the case of INT-IORS expander, connect the detectors to the zones (for description of detector connection, please refer to the manual of control panel installer). 5. Depending on the selected method of expander powering, connect the dedicated power supply unit to the connector on expander electronics board or connect the power leads to the +12V and COM terminals (the expander may be powered directly from the control panel, from an expander with power supply or from a power supply unit). The expander must not be powered from both sources at the same time.

SATEL INT-IORS / INT-ORS 5 6. Power on the alarm system. 7. Start the identification function in the control panel. After expander identification is completed, the zones and outputs will be assigned their respective numbers in the alarm system. The zone and output numeration rules are described in the control panel manual. The control panel monitors presence of the identified modules. If the module is disconnected from communication bus, position of DIP-switches is changed, or the device

6 INT-IORS / INT-ORS SATEL is replaced with another one with DIP-switches set in the same way, a tamper alarm will be triggered. 8. Configure the outputs and check that they operate properly (the output status is indicated by LEDs). 9. Power off the alarm system. 10. Connect to expander outputs the devices whose operation is to be controlled by the control panel. 11. Power on the alarm system. 6. Updating the expander firmware Using the RS-485 bus, connect the expander to the ACCO-USB converter, and then connect the converter to the computer (see: ACCO-USB converter manual). You can find a program for updating the expander firmware and a detailed description of the firmware update procedure on the www.satel.eu website. SATEL sp. z o.o. Budowlanych 66 80-298 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu