IBM Flex System Storage Expansion Node IBM Redbooks Product Guide

Similar documents
Flex System Storage Expansion Node Product Guide

ServeRAID M5115 SAS/SATA Controller for IBM Flex System IBM Redbooks Product Guide

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide

IBM 6 Gb Performance Optimized HBA IBM Redbooks Product Guide

IBM Flex System FC5024D 4-port 16Gb FC Adapter IBM Redbooks Product Guide

ServeRAID M1015 SAS/SATA Controller for System x IBM System x at-a-glance guide

N2225 and N2226 SAS/SATA HBAs for IBM System x IBM Redbooks Product Guide

S3700 SATA MLC Enterprise SSDs for IBM System x IBM Redbooks Product Guide

ServeRAID M5025 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

IBM High IOPS SSD PCIe Adapters IBM System x at-a-glance guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

IBM High IOPS MLC Adapters IBM Redbooks Product Guide

IBM Flex System EN port 10Gb Ethernet Adapter IBM Redbooks Product Guide

ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

ServeRAID M5016 SAS/SATA Controller IBM Redbooks Product Guide

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Flex System PCIe Expansion Node Product Guide

IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide

ServeRAID M5016 SAS/SATA Controller IBM System x at-a-glance guide

Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide

IBM Flex System EN Gb Ethernet Pass-thru Module IBM Redbooks Product Guide

ServeRAID H1110 SAS/SATA Controller Product Guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide

Integrated Management Module (IMM) Support on IBM System x and BladeCenter Servers

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide

2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide

Broadcom NetXtreme II Dual Port 10GBase-T Adapter for IBM System x IBM System x at-a-glance guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide

ServeRAID M5120 SAS/SATA Controller Lenovo Press Product Guide

Flex System EN port 1Gb Ethernet Adapter Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide

SATA MLC Enterprise Value SSDs (Withdrawn) Product Guide

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide

IBM ServeRAID Adapter Quick Reference

IBM Half-high LTO Generation 4 SAS Tape Drive IBM System x at-a-glance guide

Brocade 16Gb FC Single-port and Dual-port HBAs for System x IBM Redbooks Product Guide

IBM High IOPS MLC Adapters Product Guide

S3500 SATA MLC Enterprise Value SSDs for System x Product Guide

Emulex 10GbE Virtual Fabric Adapter II for IBM BladeCenter IBM Redbooks Product Guide

ServeRAID M1115 SAS/SATA Controller Product Guide

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide

IBM PowerKVM available with the Linux only scale-out servers IBM Redbooks Solution Guide

Brocade 16Gb FC Single-port and Dual-port HBAs for System x IBM Redbooks Product Guide

SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide

ServeRAID M5210 and M5210e SAS/SATA Controllers Product Guide

Lenovo Enterprise Capacity Solid State Drives Product Guide

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

IBM Flex System CN4054/CN4054R 10Gb Virtual Fabric Adapters and EN port 10GbE Adapter IBM Redbooks Product Guide

ServeRAID M1215 SAS/SATA Controller Product Guide

IMM and IMM2 Support on IBM System x and BladeCenter Servers

ServeRAID M5110 and M5110e SAS/SATA Controllers Product Guide

Flex System EN port 10Gb Ethernet Adapter Product Guide

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide

DS8880 High Performance Flash Enclosure Gen2

120 GB, 240 GB, 480 GB, and 800 GB SATA MLC Enterprise Value SSDs Product Guide

Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide

Flex System IB port FDR InfiniBand Adapter Lenovo Press Product Guide

Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

Intel I350 Gigabit Ethernet Adapter for IBM System x IBM Redbooks Product Guide

Implementing IBM CICS JSON Web Services for Mobile Applications IBM Redbooks Solution Guide

ServeRAID C100 and C105 Product Guide

Enterprise Caching in a Mobile Environment IBM Redbooks Solution Guide

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony

IBM z/os Management Facility V2R1 Solution Guide IBM Redbooks Solution Guide

ServeRAID M5225-2GB External SAS/SATA Controller Product Guide

IBM FlashSystem V Quick Start Guide IBM GI

DS8880 High-Performance Flash Enclosure Gen2

Utility Capacity on Demand: What Utility CoD Is and How to Use It

SAS MLC Enterprise SSDs for System x Product Guide

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

QLogic BS21, , and InfiniBand Switches IBM Power at-a-glance guide

IBM Ethernet Switch J48E

iscsi Configuration Manager Version 2.0

Platform LSF Version 9 Release 1.1. Migrating on Windows SC

IBM Flex System FC port 16Gb FC Adapter Lenovo Product Guide

Best practices. Reducing concurrent SIM connection requests to SSM for Windows IBM Platform Symphony

IBM High IOPS Modular Adapters (Withdrawn) Product Guide

IBM ServeRAID M-Series products offer enterpriseclass RAID solutions to enhance server storage and enable use of both SAS and SATA media

Platform LSF Version 9 Release 1.3. Migrating on Windows SC

Elastic Caching with IBM WebSphere extreme Scale IBM Redbooks Solution Guide

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

Best practices. Linux system tuning for heavilyloaded. IBM Platform Symphony

Lenovo PM1635a Enterprise Mainstream 12Gb SAS SSDs Product Guide

Getting Started with InfoSphere Streams Quick Start Edition (VMware)

Emulex 16Gb Gen 5 Fibre Channel Adapters for IBM System x IBM Redbooks Product Guide

IBM Flex System FC3171 8Gb SAN Switch and Pass-thru IBM Redbooks Product Guide

IBM 2-watt 15.8 GB 2.5-inch Solid State Drives provide new technology in performance for storage in BladeCenter

Lenovo PM863 Enterprise Entry SATA SSDs Product Guide

IBM emessage Version 8.x and higher. Account Startup Overview

Transcription:

IBM Flex System Storage Expansion Node IBM Redbooks Product Guide The IBM Flex System Storage Expansion Node is a storage enclosure that attaches to a single half-wide compute node to provide that compute node with additional direct-attach local storage. The Storage Expansion Node provide flexible storage to match capacity, performance, and reliability needs. Ideal workloads include distributed database, transactional database, NAS infrastructure, video surveillance and streaming solutions. For example, when coupled with third-party NAS software, the combined compute node and storage expansion node make for an ideal infrastructure platform for a network-attached storage (NAS) server. Figure 1 shows the IBM Flex System Storage Expansion Node attached to an IBM Flex System x240 Compute Node. Figure 1. IBM Flex System Storage Expansion Node (right) attached to an x240 Compute Node (left) Did you know? The Storage Expansion Node adds 12 drive bays to the attached compute node and all bays in the expansion node are hot-swap. The drive bays slide out on an internal rail system; provided that a suitable RAID level is employed, a failed drive can be removed while the system is still running. With storage capacity of up to 14.4 TB, the Storage Expansion Node is ideal for applications that can use large amounts of additional local storage. IBM Flex System Storage Expansion Node 1

Part number information Table 1. Ordering part number and feature code Description Part number Feature code IBM Flex System Storage Expansion Node 68Y8588 A3JF* * Feature code A3JF is for both the XCC (x-config) and AAS (e-config) ordering systems, however with AAS, this feature code is only selectable with the x220 Compute Node. You cannot order feature code A3JF with the x240 in the AAS ordering system. The part number includes the following items: IBM Flex System Storage Expansion Node Double-wide shelf Documentation CD that contains the Installation and Service Guide Warranty information and Safety flyer and Important Notices document Supported servers The IBM Flex System Storage Expansion Node is supported when it is attached to the IBM Flex System compute nodes listed in Table 2. Only one Expansion Node can be attached to each compute node. Table 2. Supported servers Description Part number IBM Flex System Storage Expansion Node 68Y8588 Y* N Y* N N N N N * The Storage Expansion Node requires that both processors be installed in the x220 and x240. The SEN is standard on one model of the x220 and the x240 as listed in the following table. Table 3. Compute node models with the Storage Expansion Node standard Model Intel processor** Memory RAID Disk bays Disks Embeded Ethernet I/O slots Flex System x220 7906-DBx 2x Xeon E5-2420 6C 1.9GHz 15 MB 1333 MHz 95W 2x 4GB ServeRAID C105 2x 2.5-in internal 12x 2.5-in with Storage Expansion Node Open 1 GbE Standard 1 / 2 Flex System x240 8737-HBx 2x Xeon E5-2640 6C 2.5GHz 15MB 1333MHz 95W 2x 8 GB LSI SAS2004 2x 2.5-in internal 12x 2.5-in with Storage Expansion Node Open 10 GbE Standard 1 / 2 ** Processor details: Processor quantity and model, cores, core speed, L3 cache, memory speed, and power rating. The 2.5-inch drive bays in the compute nodes can be replaced and expanded with 1.8" solid-state drive bays and a ServeRAID M5115 RAID controller to support up to eight 1.8-inch SSDs. (Used / maximum) These models include an Embedded 1 Gb or 10 Gb Ethernet controller. Connections are routed to the chassis midplane using a Fabric Connector. The Fabric Connector precludes the use of an I/O adapter in I/O connector 1 (with the exception of the ServeRAID M5115 RAID controller). IBM Flex System Storage Expansion Node 2

The models in the previous table are Network Attached Storage (NAS)-optimized models that includes the compute node and the SEN connected together as a single unit at the factory. This single model number enables a simpler acquisition for both business partners and direct sales. The combination of the compute node and the SEN is certified with Windows Storage Server 2012 meaning that this configuration is an excellent platform for a low cost NAS solution. Windows Storage Server 2012 is available via the IBM Reseller Option Kit (ROK) program using part number 00Y6302. These models do not include drives giving you maximum flexibility when it comes to selecting drives, either SAS or SATA disk drives or high-performance SSDs. Features The System Expansion Node has the following features: Connects directly to supported compute nodes via a PCIe 3.0 interface to the compute node's interposer connector (also known as the ETE connector) Support for 12 hot-swap 2.5-inch drives, accessible via a sliding tray Support for 6 Gbps SAS and SATA drives, both HDDs and SSDs Based on an LSI SAS2208 6 Gbps RAID on Chip (ROC) controller Supports RAID 0, 1, 5, 10, and 50 as standard. JBOD also supported. Optional RAID 6 and 60 with a Features on Demand upgrade. Optional 512 MB or 1 GB cache with cache-to-flash super capacitor off-load Includes an expansion shelf to physically support the Storage Expansion Node and its compute node attached together Internal and external light path diagnostics Optional Feature on Demand upgrades for RAID 6, 60 support and SSD performance and caching enablers Optional support for SSD performance acceleration and SSD caching with Features on Demand upgrades Support for up to 64 virtual drives, up to 128 drive groups, up to 16 virtual drives per one drive group, and up to 32 physical drives per one drive group Support for logical unit number (LUN) sizes up to 64 TB Configurable stripe size up to 1 MB Compliant with Disk Data Format (DDF) configuration on disk (COD) S.M.A.R.T. support Managed through the IMMv2 management processor on the compute node and with the MegaRAID Storage Manager management software IBM Flex System Storage Expansion Node 3

Architecture Figure 2 shows the architecture of the Storage Expansion Node when connected to a compute node. Figure 2. Architecture of the Storage Expansion Node The Expansion Node connects to a standard-width compute node using the interposer cable, which plugs into the expansion connector on the compute node. This link forms a PCIe 3.0 x8 connection between Processor 2 on the compute node and the LSI RAID controller in the Expansion Node. The result is that the compute node sees the disks in the expansion node as locally attached. Management of the Storage Expansion Node is via the IMMv2 located on the compute node. Note: The expansion connector in the x220 and x240 compute nodes is routed through processor 2. Therefore, processor 2 must be installed in the compute node. IBM Flex System Storage Expansion Node 4

Supported disk drives The Storage Expansion Node is a PCIe 3.0 and a SAS 2.1 complaint enclosure supporting up to twelve 2.5-inch drives. The drives can be HDD or SSD, and both SAS or SATA. Drive modes supported are JBOD or RAID-0, 1, 5, 6, 10, 50, and 60. The drives are accessed by opening the handle on the front of the Storage Expansion Node and sliding out the drive tray. Opening the drive tray can be done while it is operational. Figure 3 shows the Storage Expansion Node connected to an x240 compute node and with the drive tray extended part way out. With the drive tray extended, all twelve hot-swap drives can be accessed on the left side of the tray. Figure 3. Storage Expansion Node with drive tray part way extended The following table lists the hard disk drives (HDDs) and solid state drives (SSDs) supported within the Storage Expansion Node. Both SSDs and HDDs can be installed inside the unit at the same time. Preferred practice when creating logical drives is to use similar disk types. For example, for a RAID 1 pair, choose identical drive types, SSD or HDD. Table 4. Supported drives (Part 1) Part number Feature code Description Maximum supported 10K SAS hard disk drives 90Y8877 A2XC IBM 300GB 10K 6Gbps SAS 2.5" SFF G2HS HDD 12 90Y8872 A2XD IBM 600GB 10K 6Gbps SAS 2.5" SFF G2HS HDD 12 81Y9650 A282 IBM 900 GB 10K 6 Gbps SAS 2.5" SFF HS HDD 12 00AD075 A48S IBM 1.2TB 10K 6Gbps SAS 2.5'' G2HS HDD 12 15K SAS hard disk drives 90Y8926 A2XB IBM 146GB 15K 6Gbps SAS 2.5" SFF G2HS HDD 12 IBM Flex System Storage Expansion Node 5

Table 4. Supported drives (Part 2) Part number Feature code Description Maximum supported NL SATA 81Y9722 A1NX IBM 250 GB 7.2K 6 Gbps NL SATA 2.5" SFF HS HDD 12 81Y9726 A1NZ IBM 500 GB 7.2K 6 Gbps NL SATA 2.5" SFF HS HDD 12 81Y9730 A1AV IBM 1TB 7.2K 6 Gbps NL SATA 2.5" SFF HS HDD 12 10K and 15K Self-encrypting drives (SED) 90Y8944 A2ZK IBM 146GB 15K 6Gbps SAS 2.5" SFF G2HS SED 12 90Y8913 A2XF IBM 300GB 10K 6Gbps SAS 2.5" SFF G2HS SED 12 90Y8908 A3EF IBM 600GB 10K 6Gbps SAS 2.5" SFF G2HS SED 12 81Y9662 A3EG IBM 900GB 10K 6Gbps SAS 2.5" SFF G2HS SED 12 00AD085 A48T IBM 1.2TB 10K 6Gbps SAS 2.5'' G2HS SED 12 SAS-SSD Hybrid drive 00AD102 A4G7 IBM 600GB 10K 6Gbps SAS 2.5'' G2HS Hybrid 12 Solid-state drives - Enterprise 41Y8331 A4FL S3700 200GB SATA 2.5" MLC HS Enterprise SSD 12 41Y8336 A4FN S3700 400GB SATA 2.5" MLC HS Enterprise SSD 12 41Y8341 A4FQ S3700 800GB SATA 2.5" MLC HS Enterprise SSD 12 49Y6129 A3EW IBM 200GB SAS 2.5" MLC HS Enterprise SSD 12 49Y6134 A3EY IBM 400GB SAS 2.5" MLC HS Enterprise SSD 12 49Y6139 A3F0 IBM 800GB SAS 2.5" MLC HS Enterprise SSD 12 49Y6195 A4GH IBM 1.6TB SAS 2.5" MLC HS Enterprise SSD 12 Solid-state drives - Enterprise Value 90Y8643 A2U3 IBM 256GB SATA 2.5" MLC HS Enterprise Value SSD 12 IBM Flex System Storage Expansion Node 6

Feature upgrades The Storage Expansion Node supports the upgrades listed in the following table. Table 5. Supported adapter cards Part number Feature code Description Maximum supported Cache upgrades 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash/RAID 5 Upgrade for IBM System x 1* 81Y4487 A1J4 ServeRAID M5100 Series 512MB Flash/RAID 5 Upgrade for IBM System x 1* Features on Demand upgrades (license only) 90Y4410 A2Y1 ServeRAID M5100 Series RAID 6 Upgrade for IBM Flex System 1** 90Y4447 A36G ServeRAID M5100 Series SSD Caching Enabler for IBM Flex System 1** 90Y4412 A2Y2 ServeRAID M5100 Series Performance Accelerator for IBM Flex System 1** * The cache upgrades are mutually exclusive. ** FoD upgrades for ServeRAID are system-wide: If you have these features installed on the M5115 in the compute node they will automatically be activated on the LSI controller in the Storage Expansion Node. ServeRAID M5100 Series 512MB and 1GB Flash Upgrade option part numbers include the following items: Cache module Flash power module Cable The cache module is installed at the rear of the Storage Expansion Node and the power module is installed near the front of the expansion node. The provided cable is used to connect the cache module to the power module. Figure 4 shows the flash-backed cache module, power module, and power cable. Figure 4. Flash-backed cache module, power module, and power cable IBM Flex System Storage Expansion Node 7

The following license-only Features on Demand upgrades are available; RAID 6 Upgrade (90Y4410) Adds support for RAID 6 and RAID 60. This is a Feature on Demand license. Performance Upgrade (90Y4412) The Performance Upgrade for IBM Flex System (implemented using the LSI MegaRAID FastPath software) provides high performance I/O acceleration for SSD-based virtual drives by using an extremely low latency I/O path to increase the maximum I/O per second (IOPS) capability of the controller. This feature boosts the performance of applications with a highly random data storage access pattern, such as transactional databases. Part number 90Y4412 is a Feature on Demand license. SSD Caching Enabler for traditional hard drives (90Y4447) The SSD Caching Enabler for IBM Flex System (implemented using the LSI MegaRAID CacheCade Pro 2.0) is designed to accelerate the performance of hard disk drive (HDD) arrays with only an incremental investment in solid-state drive (SSD) technology. The feature enables the SSDs to be configured as a dedicated cache to help maximize the I/O performance for transaction-intensive applications, such as databases and web serving. The feature tracks data storage access patterns and identifies the most frequently accessed data. The hot data is then automatically stored on the SSDs that are assigned as a dedicated cache pool on the ServeRAID controller. Part number 90Y4447 is a Feature on Demand license. This feature requires that at least one SSD drive is installed. FoD upgrades are system-wide: The FoD upgrades are the same ones as used with the ServeRAD M5115 available for use internally in the x220 and x240 compute nodes. If you have an M5115 installed in the attached compute node and have installed any of these upgrades, the upgrades will automatically be activated on the LSI controller in the Storage Expansion Node. You do not need to purchase the FoD upgrades separately for the expansion node. LED indicators The Storage Expansion Node has a number of LEDs on the lower right front for identification and status purposes, as shown in Figure 5. Figure 5. LEDs on the front of the Storage Expansion Node IBM Flex System Storage Expansion Node 8

The following table identifies the meanings of the LEDs. Table 6. External LED status table LED Color Meaning Activity light (each drive bay) Green Blinks with Activity, displaying drive number. Fault/Locate Amber Solid: Indicates a fault on one of the drives Blink: One of the drives is set to identify Tray Open Amber Flash/beep 15 sec interval: Drawer is not fully closed. Flash/beep 5 sec interval: Drawer has been opened to long, close drawer immediately Flash/beep.25 sec interval: Expansion node has reached thermal threshold. Close door immediately to avoid drive damage. In addition to the lights described in the previous table, there are LEDs locally on each of the drive trays. These lights can be observed when the drive tray is extended and the unit is operational. A green LED indicates disk activity and an amber LED indicates a drive fault. With the Storage Expansion Node removed from the Flex System chassis and its cover removed, there are additional LEDs visible. If there is a fault detected then the relevant LED will light: Flash/RAID adapter: RAID Cache card fault. Control panel: LED panel card not present Temperature: A temperature event has occurred Storage expansion: Fault on the storage expansion unit Light path: Verify that the light path diagnostic function, including the battery, is operating properly Physical specifications Dimensions and weight (approximate): Height: 56 mm (2.2 in.) Depth: 504 mm (19.8 in.) Width: 229 mm (9.2 in.) Maximum weight: 5.9 kg (13 lb) Shipping dimensions and weight (approximate): Height: 240 mm (9.5 in.) Depth: 680 mm (26.8 in.) Width: 601 mm (23.7 in.) Weight: 9.5 kg (21 lb) IBM Flex System Storage Expansion Node 9

Operating environment When the unit is powered on, it is supported in the following environment: Temperature: 5 C to 40 C (41 F to 104 F) Humidity, non-condensing: -12 C dew point (10 F) and 8% - 85% relative humidity Maximum dew point: 24 C (75 F) Maximum altitude: 3048 m (10,000 ft) Maximum rate of temperature change: 5 C/hr (41 F/hr) Regulatory compliance The unit conforms to the following standards: ASHRAE Class A3 FCC - Verified to comply with Part 15 of the FCC Rules Class A Canada ICES-004, issue 3 Class A UL/IEC 60950-1 CSA C22.2 No. 60950-1 NOM-019 Argentina IEC 60950-1 Japan VCCI, Class A IEC 60950-1 (CB Certificate and CB Test Report) China CCC (GB4943); (GB9254, Class A); (GB17625.1) Taiwan BSMI CNS13438, Class A; CNS14336 Australia/New Zealand AS/NZS CISPR 22, Class A Korea KN22, Class A, KN24 Russia/GOST ME01, IEC 60950-1, GOST R 51318.22, GOST R 51318.249, GOST R 51317.3.2, GOST R 51317.3.3 IEC 60950-1 (CB Certificate and CB Test Report) CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3) CISPR 22, Class A TUV-GS (EN60950-1/IEC 60950-1, EK1-ITB2000) IBM Flex System Storage Expansion Node 10

Related publications For more information, see the following resources: IBM US Announcement Letter http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/enus112-185 IBM Flex System product page http://ibm.com/systems/flex IBM Flex System Information Center http://publib.boulder.ibm.com/infocenter/flexsys/information/index.jsp IBM ServerProven hardware compatibility page for IBM Flex System http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/ IBM Flex System x240 Compute Node, IBM Redbooks Product Guide http://www.redbooks.ibm.com/abstracts/tips0860.html IBM Flex System x220 Compute Node, IBM Redbooks Product Guide http://www.redbooks.ibm.com/abstracts/tips0885.html ServeRAID M5115 SAS/SATA Controller for IBM Flex System, IBM Redbooks Product Guide http://www.redbooks.ibm.com/abstracts/tips0884.html?open IBM Flex System Storage Expansion Node 11

Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-ibm product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-ibm Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.ibm may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-ibm products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-ibm products. Questions on the capabilities of non-ibm products should be addressed to the suppliers of those products. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. Copyright International Business Machines Corporation 2012. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. IBM Flex System Storage Expansion Node 12

This document was created or updated on July 30, 2013. Send us your comments in one of the following ways: Use the online Contact us review form found at: ibm.com/redbooks Send your comments in an e-mail to: redbook@us.ibm.com Mail your comments to: IBM Corporation, International Technical Support Organization Dept. HYTD Mail Station P099 2455 South Road Poughkeepsie, NY 12601-5400 U.S.A. This document is available online at http://www.ibm.com/redbooks/abstracts/tips0914.html. Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol ( or ), indicating US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: IBM Flex System IBM Redbooks Redbooks (logo) ServerProven System x Other company, product, or service names may be trademarks or service marks of others. IBM Flex System Storage Expansion Node 13