80W (16V/5A) Power Supply with USB Output. User Manual

Similar documents
1-36V, 0-3A DC Power Supply

Laboratory Switch Mode Power Supply Series. Instruction Manual

Dual Range DC Power Supply

Dual Range DC Power Supply

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

NTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL

DC 100 A Current Probe

Switching DC Power Supply

99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL

INSTRUCTION MANUAL. Triple Output DC POWER SUPPLY MODELS 1651A & 1652 MODELOS 1651A & El Manual de la Instrucción

CIRCUIT-TEST. Switching Mode Power Supply with USB Remote Control PSC VDC / 5A PSC VDC / 3A PSC VDC / 1.

Multi Range DC Power Supply

DC 100 A Current Probe

High Precision Quad Output DC Power Supply

Digital Control Power Supply IT6720. User s Manual. Access for more products information

3700 SERIES USER MANUAL

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

User's Guide. Model W 3-in-1 Switching DC Power Supply

Mini Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

99 Washington Street Melrose, MA Phone Toll Free Visit us at

User's Guide. Model High Precision Quad Output DC Power Supply

MC-12 Software Installation Instructions

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

INSTRUCTION MANUAL MODELS: 1760A, 1761, Triple Output DC POWER SUPPLY With Dual 4-Digit LED Displays

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

LABORATORY GRADE REMOTE PROGRAMMING SWITCHING MODE DC REGULATED POWER SUPPLIES SDP / 3636 / User Manual

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Model 9129B Triple Output Programmable DC Power Supply USER MANUAL

Multi-Range DC Power Supply

PS-3005P Programmable DC Power Supply

Model A Mini AC/DC Clamp Meter. User's Guide

1. PRODUCT INTRODUCTION Description 1-2. Feature...

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

User Guide True RMS Multimeter Extech EX205T

Operating Instructions. LSP-KONSTANTER Series 32K Laboratory Power Supply 8/10.13

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

Agilent 70612B K18 Switch Matrix

Model 7705 Control Module

Digital Clamp Meter User Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Mini Digital Multimeter

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

CS2 DMX Distribution Splitter

Keysight U8030 Series Triple-Output DC Power Supplies

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

User Manual VX4234 Digital Multimeter Module

User Guide. TP3016M Series Switching Mode DC Power Supply

USER S MANUAL Linear Programmable DC Power Supply APS

Users Manual. Two Forward Switching Power Supply ZM500/600-LX. Ver

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Programmable DC Power Supplies

HP4 headphone amplifier. user manual

SBS-S SERIES DC LOAD BANK USER MANUAL Rev

UV Power Flood. User Manual. Order code: EQLED029

HV-CS kv Edge Mount Triaxial Jack

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

PS-5030 (5A) OPERATION MANUAL

Model DCP42 160W Laboratory Grade Constant Power, Switching Mode Power Supply

LABORATORY GRADE. REMOTE PROGRAMMING SWITCHING MODE DC regulated Power Supplies

HCS-3200/3202/3204 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

Agilent E3632A DC Power Supply

TPC25 active crossover. user manual

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

Autoranging True RMS Multimeter User Manual

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Model 9103 and Multi-Range DC Power Supply USER MANUAL

PS-1030 (30V) OPERATION MANUAL

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Crossfire. User Manual. Order code: EQLED061

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

TC100 Precision Thermocouple Calibrator

±15 V Current-Limited Power Supply

USER'S MANUAL DCL-650

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Modular Power System 1200 W per mainframe GPIB

Mini Digital Multimeter Model MN15. User's Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Series Watt DC Power Supplies

OPERATING INSTRUCTION

Universal AC Power Source + AC Power Analyzer

RZ2 BioAmp Processor. Operator s Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Achat 110 MA active full-range speaker. user manual

1. Safety Precautions. 2. Components. 3. Notes on Installation. Caution. Warning

DM3058/DM3058E Digital Multimeter

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

High Power Programmable DC Power Supply

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Transcription:

Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A USB CHARGER GND OUTPUT 5 A MAX.

Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases of operation, service, and repair of this instrument. Before applying power, follow the installation instructions and become familiar with the operating instructions for this instrument. GROUND THE INSTRUMENT To minimie shock haard, the instrument chassis and cabinet must be connected to an electrical ground. This instrument is grounded through the ground conductor of the supplied, three-conductor ac power cable. The power cable must be plugged into an approved three-conductor electrical outlet. Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including control knobs) can render an electric shock. The power cable meets IEC safety standards. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety haard. KEEP AWAY FROM LIVE CIRCUITS Instrument covers must not be removed by operating personnel. Component replacement and internal adjustments must be made by qualified maintenance personnel. Disconnect the power cord before removing the instrument covers and replacing components. Under certain conditions, even with the power cable removed, dangerous voltages may exist. To avoid injuries, always disconnect power and discharge circuits before touching them. 1

DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT Do not install substitute parts or perform any unauthoried modifications to this instrument. Return the instrument to Global Specialties (Cal Test Electronics) for service and repair to ensure that safety features are maintained. WARNINGS AND CAUTIONS WARNING and CAUTION statements, such as the following examples, denote a haard and appear throughout this manual. Follow all instructions contained in these statements. A WARNING statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel. A CAUTION statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in damage to or destruction of parts or the entire product. WARNING Do not alter the ground connection. Without the protective ground connection, all accessible conductive parts (including control knobs) can render an electric shock. The power jack and mating plug of the power cable meet IEC safety standards. WARNING To avoid electrical shock haard, disconnect power cord before removing covers. Refer servicing to qualified personnel. CAUTION Before connecting the line cord to the AC mains, check the rear panel AC line voltage indicator. Applying a line voltage other than the indicated voltage can destroy the AC line fuses. For continued fire protection, replace fuses only with those of 2

the specified voltage and current ratings. CAUTION This product uses components which can be damaged by electro-static discharge (ESD). To avoid damage, be sure to follow proper procedures for handling, storing and transporting parts and sub-assemblies which contain ESDsensitive components. Compliance Statements Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems). This product is subject to Directive 2012/19/EU of the European Parliament and the Council of the European Union on waste electrical and electronic equipment (WEEE), and in jurisdictions adopting that Directive, is marked as being put on the market after August 13, 2005, and should not be disposed of as unsorted municipal waste. Please utilie your local WEEE collection facilities in the disposition of this product and otherwise observe all applicable requirements. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 3

1 Introduction The 1325 is a micro-controller based switching DC power supply with a total supply capability of 80 W. By using a digital + / - keypad operation control, you can easily set the output voltage and current levels. The 1325 s small sie and quiet operation make it ideal for laboratory, work shop, or educational applications where bench space is limited. The 1325 has a USB charger output, constant current operation, tracking OVP, floating ground design, small footprint, output on/off push button and a small form factor. 1.1 Features 80 W Power Voltage: 1 V to 16 V Current: 0 A to 5 A Small compact sie 3-Digit display shows voltage or current Automatic crossover and constant current (CC) Constant voltage operation USB charging port, 5 VDC and 1.2 A Max Tracking Over Voltage Protection (OVP) Over Temperature Protection (OTP) 4

2 Operating the Power Supply 2.1 Connection and Operation Procedure 1. Plug the unit into 110 VAC grounded outlet. 2. Switch on the power supply using the toggle switch on the back and the LED display will come on showing OFF indicating that output is off. The Volt. indicator will light showing that you are displaying voltage. The C.V. indicator will light showing that you are in Constant Voltage mode. 3. Push V to view/change the voltage settings. Push A to view/change the current limit settings. 4. The (+) and (-) keys are used to adjust the value of output voltage or output current limit setting. Press the (+)/(-) once to view the set value without changing the setting. Press (+)/(-) again and the value will start to change. 5. Connect to your load positive to positive and negative to negative. 6. Turn on the output terminal and check if display shows (CV). 7. If display shows (CC), either your preset current limiting value is too low or your load requires more voltage and current. You need to re-access the voltage and current requirement of your load and increase the voltage or current accordingly until (CV) appears. 2.2 Automatic Crossover The power supply functions as a constant voltage source (CV) as long as the load current is less than the set current limit value. When the load current is equal to or greater than the set current limit value, the power supply will automatically cross over to the constant current mode, voltage will drop, (CC) will show on the LCD display panel and it will operate as a constant current source. 6

When the load current drops below the preset current limiting value, the supply returns to constant voltage (CV) mode. 2.3 Tracking Output Over Voltage Protection (OVP) This is to protect the connected load in the event that the output voltage control circuit malfunctions. In the case where the output voltage reaches 15% higher than the set voltage, Over Voltage Protection will engage. The display will show OVP and the main output will switch OFF. The protection message can be cleared by powering up the unit again or by pressing the output ON/OFF key. 2.4 Over Temperature Protection (OTP) When the temperature inside the power supply becomes higher than a predetermined value, the output of the power supply will automatically switch OFF and the display will show OTP. When the temperature inside the power supply drops to an acceptable level, the protection message can be cleared by powering up the unit again or pressing the output ON/OFF key. 2.5 Ground Connection Depending on the application, the power supply output terminals can be grounded in one of the following setups: Negative ground black (-) negative terminal is shorted with green GND terminal. Positive ground red (+) positive terminal is shorted with green GND terminal. Floating ground green terminal is not shorted with any of the output terminals. When operating this power supply as a floating ground, high impedance leakage can exist between the power supply circuitry and the chassis ground. 7

3 Specifications All specifications apply to the unit after a temperature stabiliation time of 15 minutes over an ambient temperature range of 25 C ± 5 C. 1325 Power Supply Electrical Specificaitons Output Voltage 1 16 VDC Output Current 0-5 A Switching Operation Frequency 75 kh to 95 kh Efficiency at Max Power 82% Voltmeter and Ampmeter Display 3 Digit 7-Segments LED Voltmeter Accuracy ±1% rdg + 3 digits Ammeter Accuracy ±1% rdg + 5 digits Resolution 0.1V, 0.01A Line Input 120 VAC (50-60 H) ±10% Full Load Input Current at 120 VAC 1.8 A Cooling System Natural Convection Constant Voltage Characteristics Load regulation (10%-90%) ±50 mv Line regulation (min to max) ±20 mv Ripple (rms) ±20 mv Noise (peak to peak) ±100 mv Constant Current Characteristics Load regulation (10%-90%) ±30 ma Line regulation (min to max) ±10 ma USB Output 8 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

Output Voltage 5 V (±5%) Output Current 1.2 A Max Environmental Conditions max RH of 80% at Operating Temp/Humidity 31 C decreasing linearly to 50% at 40 C Altitude up to 2,000 m Polution Degree Polution Degree 2 Mechanical Characteristics Weight 3.0 lbs (1.4 kg) Dimensions 2.8 x 6.0 x 7.9 in (70 x 150 x 200 mm) Specifications are subject to change without notice. 9

Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 10

450864-001 Rev. B