Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Similar documents
Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

DAQ-System for DynoWare

MODEL 9250 Preliminary data sheet

SCP for Plastics Processing

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

PRODUCT DATA. Charge to CCLD Converter Types 2647 A, B, C, D, D 001, D 002, D 003, D 004, and E. Features and Benefits. Features

GFK-2415A March Type of sensor connection

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input with Loop Power 7B35

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

KiTorq Stator. Torque. Torque Evaluation Unit (Stator) for a Torque Measuring Flange. Type 4541A...

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T

HV-4U for imc CRONOSflex (CRFX/HV-4U)

Advanced Wind Turbine Concept. Mita-Teknik. Data Sheets. Condition Monitoring Mita-Teknik. All rights reserved

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

high performance signal conditioner cards

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

digiclip Data sheet DF31DP Special features B en

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

USB-1602HS-2AO Specifications

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

MX1609TB. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ComoNeo. Electronics & Software. System for Process Monitoring and Process Optimization in Plastic Injection Molding Applications. Type 5887A...

Micro Motion Model 7950 and Model 7951 Signal Converters

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

Application The standard SmartCrash segment is used vertically in the automotive industry and in vehicle crash test centers, and horizontally in tower

Instruction Manual. 8 Channel IEPE Conditioner M208A. From Version Manfred Weber

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

BSL Hardware Guide for MP35 and MP30-1 -

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

USB-2527 Specifications

Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies

IST ULTRASTAB Power Supply for high precision transducers

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

IOC4T. Input / output card. » From the Vibro-Meter product line» Signal interface card with 6 channels, for the MPC4 machinery protection card

TraNET FE Data Acquisition Instrument

Data Acquisition & Signal Conditioning Units

TANDO 700. High-precision measuring and analysis system for dissipation/power factor and capacitance

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

digiclip Data sheet DF31CAN Special features B en

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

6220 Ethernet-Based Voltage Measurement Module

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

ComoNeo. Electronics & software. System for process monitoring and process optimization in plastic injection molding applications. Type 5887A...

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

imc CRONOSflex Base Unit (CRFX-400/CRFX-2000)

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

WP3x00 MK ll Controller. control systems. All control functions are integrated. Integrated realtime grid measurement

WebDAQ 316. Internet Enabled Thermocouple Logger. Remote Configuration and Monitoring. Virtually Unlimited Storage. Integrated HW and SW

Programmable Power Supplies 188 W 384 W HMP Series

MB Millenium Single- and Multi-Axis Vibration and Motion Control System

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

MX590B-R. Pressure amplifier. Special features. Data sheet. Block diagram

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ControlMonitor CoMo View

Inform IT Single Pen Circular Chart Recorder

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

dac1421 Users Manual Discrete R-2R DAC / HeadAmp

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

HCS1 Three-Axis Helmholtz Coil System

High Voltage Power Supplies

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

6220 Ethernet-Based Voltage Measurement Module

SYSTEM DATA. VC-LAN Vibration Controller Types 7541 and Uses and Features

SYSTEM DATA. VC-LAN Vibration Controller Types 7541 and Uses and Features

Trend-1 Vibration Data Logger. User Manual

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Instruction Manual. CCP Supply Type 12AL SOUND & VIBRATION. Skovlytoften 33, 2840 Holte, Denmark

Features. Description. Applications

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

General information. Display. Supply voltage. Input current

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Model KT 53 Cooling incubators with thermoelectric cooling

Ultra-Accurate Temperature Measurement Instruments

SCC-AO10 Isolated Analog Output Module

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

Precision Voltage Measurement. Instruments. Applications. Voltage Inputs. High-Stability, Low Drift Voltage References. Key Design Features

DSP Filter System. Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, Doc Number: AIGO-009

Transcription:

Electronics & Software Kistler LabAmp Charge Amplifier and Data Acquisition Unit for Dynamic Measurements This universal laboratory charge amplifier can be used wherever dynamic signals of mechanical quantities are measured with piezoelectric sensors, Piezotron sensors (IEPE) or sensors with voltage output. Piezoelectric sensors produce an electric charge which varies in direct proportion with the load acting on the sensor. The amplifier converts this charge directly into digital values or a proportional output voltage. 1 or 4 channel amplifier for piezoelectric sensors (charge), Piezotron sensors (IEPE) and voltage Integrated 24-bit data acquisition with up to 200 ksps per channel Continuous digital signal processing at minimal latency Fully flexible low-pass, high-pass and notch filter adjustment Low-noise design TEDS (IEEE 1541.4) for Piezotron sensors 1 or 4 analog outputs with fully flexible 2-point scaling and internal routing Status indication per channel via LED Configuration and control in a standard web-browser Virtual instrument driver for LabVIEW Two Ethernet interfaces with included switch functionality Description The Kistler LabAmp is not only an outstanding low-noise charge amplifier for dynamic signals but also a powerful data acquisition device delivering the digitized measurement values directly to a host computer for further analysis. It is configured and operated in a web-interface, conveniently accessible by a standard web-browser. Thanks to advanced signal processing technology, the Kistler LabAmp offers impressive flexibility. The frequencies of the highpass, low-pass and notch filters can be directly entered as numeric values in Hertz. Virtual channels allow mathematical calculations in real-time. The input signals and the virtual channels can be flexibly routed to the analog outputs. The graphical user interface not only offers a simple and intuitive way to configure the device but also displays different measurement values (e.g. live value, peak value, root mean square). Furthermore, the browser-based data download allows the acquired data to be processed in an analysis software. For more advanced tasks or direct analysis, the amplifier can be integrated directly into LabVIEW thanks to the provided Virtual Instruments Driver. Page 1/5

Technical Data Connections Number of channels Type 5165A1 1 Type 5165A4 4 Input connector type BNC neg. Analog output connector type BNC neg. Ethernet interface 2xRJ45 Charge Input Measuring range pc ±100 1 000 000 Frequency range ( 3dB) 0,1 100 000 Input noise (typ.) 100 pc pc pp 0,035 1 000 pc pc pp 0,055 10 000 pc pc pp 0,35 100 000 pc pc pp 5,5 1 000 000 pc pc pp 35 100 pc pc pp 0,035 1 000 pc pc pp 0,04 10 000 pc pc pp 0,25 100 000 pc pc pp 2,9 1 000 000 pc pc pp 20 Maximum input voltage V ±30 Measuring range <100 pc % <1 Measuring range 100 pc % <0,5 impedance MΩ >10 Piezotron Input Gain 1/10 supply voltage V 22 Power supply ma 4/10 Frequency range ( 3dB) 0,1 100 000 Input interference (typ. 0 Ω shunt at input) Gain 1 μv pp 435 Gain 10 μv pp 55 Gain 1 μv pp 316 Gain 10 μv pp 22 Maximum input voltage V ±30 Gain 10 % <1 Gain 1 % <0,5 Voltage Input Input type single-ended Measuring range V ±1 10 Input impedance MΩ 10 Frequency range ( 3dB) 0 100 000 Input interference (typ. values) Measuring range 1 V μv pp 55 Measuring range 10 V μv pp 435 Measuring range 1 V μv pp 22 Measuring range 10 V μv pp 360 Max. input voltage V ±30 Measuring range <1 V % <1 Measuring range 1 V % <0,5 Voltage Output Nominal output range V ±10 Measuring range scaling factor ±0,1... ±10 Output impedance Ω 10 Max. common mode voltage V ±14 between input and output ground Output interference (all ranges) 0,1... 1 M, typ./max. mv pp 2,6/5, typ. mv pp 2,3 Frequency range ( 3dB) 0 100 000 Group delay (filters off) μs 12 Zero error mv <±2 DAC resolution (analog out) Bit 16 Page 2/5

Technical Data (Continuation) Data Acquisition resolution Bit 24 Sampling rate per channel ksps 200 (adjustable) Digital High-Pass Filter Filter type Bessel or Butterworth Order 2./4. Cutoff-frequency ( 3dB) 10 selection in 1 steps Ethernet Interface Data rate MBit 100 Power Supply Requirements Supply voltage range VDC 18 30 Power consumption W <15 Socket for barrel jack plug mm 5,5x2,5x9,5 (IEC 60130-10 Type A) Power supply requirements galvanic isolation PE and GND not connected Digital Low-Pass Filter Filter type Bessel or Butterworth Order 2./4. Cutoff-frequency ( 3dB) 10 selection in 1 steps Digital Notch Filter Center frequency 15 selection in 1 steps Q factor 0,8... 100 General Data Operating temperature range C 0 60 Storage temperature range C 10 70 Rel. humidity, not condensing % 90 Degree of protection (EN 60529) IP20 Outer dimensions incl. feet and mm 218x50x223 connectors (WxHxD) Weight kg 1,2 Application The instrument has been designed for use in research, development and the laboratory. The Kistler LabAmp is the perfect choice wherever dynamic signals need to be measured precisely and with high resolution. Acceleration and vibration measurements, pulsating pressure applications or force measurements of fast machining procedures are just a few examples where the Kistler LabAmp Type 5165A can demonstrate his strengths. Operation All settings are configured in a standard web-browser through the graphical user interface. Simply connect to the Kistler LabAmp by its network name and start working. A simple data acquisition is also implemented, offering a data download controlled by a start/stop button. In addition, an API is available to perform automated measuring tasks PCbased. Page 3/5

Block Diagram Isolated Output Supply Power Power Supply 1 Out 1 2 Out 2 3 Digital Signal Processing Out 3 4 DAC _ Out 4 10M USB Processor Ethernet 1 Ethernet 2 Case Fig. 1: Block diagram of the Kistler LabAmp Page 4/5

Dimensions LabAmp Type 5165A 1 2 3 4 Out 1 2 3 4 8,6 40,95 217,5 ca.16 202 5 120 6,7 Power 24V GND SN 1234567 18... 30V W Kistler Instrumente AG Winterthur Switzerland Made in Switzerland USB Ethernet 1 Ethernet 2 Reset Fig. 2: Dimensions of Kistler LabAmp Type 5165A4 Included Accessories Type/Mat. No. Calibration sheet Quick-start guide Optional Accessories Power supply* 24 V incl. country-specific plug Ethernet cable, l = 2 m* 19" rack mounting tablet Dummy panel for empty 19" position * Available as combined kit together with the amplifier Type/Mat. No. 5779A2 tbd 5748A1 5748A2 Ordering Key LabAmp Single-channel 1 4 channels 4 Amplifier only Kit with amplifier, 24 V power supply, K 2 m Ethernet cable Type 5165A LabVIEW is a registered trade mark of National Instruments Corporation. Page 5/5