Model Curriculum. Assistant Technician: Street Light Installation & Maintenance SECTOR: SUB-SECTOR: OCCUPATION: POWER DISTRIBUTION

Model Curriculum. CCTV Installation Technician

Working under tension V Tool cases. ...convincing solutions. Hard top tool cases, Leather tool cases

Electrician. Skilled Migration Assessment Services / Trades Recognition Services

CURRICULUM FOR SIX MONTH CERTIFICATE COURSE FITTING & PLUMBING UNDER DEVELOPMENT. Prepared By CURRICULUM DEVELOPMENT CELL

Model Curriculum. Handset Repair Engineer (Level II) TELECOM HANDSET CUSTOMER SERVICE TEL/Q2201, V1.0 4

Frequently Asked Questions (FAQs) for Master Trainers

Tech-Vidhya (A Unit of Aayan Infratel Pvt. Ltd.) An ISO 9001 : 2008 Certified Company. Course Information!

Course Title: Core Curriculum, Introduction to Craft Skills, Year One 1 st Semester. A.M. Session: 7:25AM 9:45AM. P.M. Session: 11:35AM 2:00PM

Frequently Asked Questions (FAQs) for Trainer

Image Key Part Number Description Substitution Qty.

Blackout Shutter Kits with Breathable Wall Light Traps

Model Curriculum. Installation Technician-Computing and. Peripherals SECTOR: SUB-SECTOR: OCCUPATION: REF ID: NSQF LEVEL:

Model Curriculum. Broadband Technician SECTOR: SUB-SECTOR: OCCUPATION: REF ID: NSQF LEVEL:

Blackout Shutter Kits with Breathable Wall Light Traps

Model Curriculum. Telecom Embedded Hardware Developer SECTOR: SUB-SECTOR: OCCUPATION: REF ID: NSQF LEVEL:

ABB DRIVES UK gland plate (+H358) ACS880-11, ACS880-31, ACH580-31, ACQ Installation guide

Tata Hitachi JIM (Japan-India Institute for Manufacturing)

Model Curriculum. Equity Dealer. Equity Dealer SECTOR: SUB-SECTOR: OCCUPATION: REFERENCE ID: NSQF LEVEL:

Model Curriculum GRTP SECTOR: TELECOM SUB-SECTOR: NETWORK MANAGED SERVICES OCCUPATION: OPERATION & MAINTENANCE REF ID: TEL/Q6207 NSQF LEVEL: 4

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

Terragraph Installation Guide. March 8, 2017 Version 0.3

CHAPTER 3B: ELECTRONIC POWER STEERING

Illustrated Parts List

Model Curriculum. Telecom Terminal Equipment Application Developer (Android)

Model Curriculum. Field Technician Computing and Peripherals

INSTALLATION MANUAL. LO SIDE BOX ADD-ON KIT For driver or passenger side configurations TRUCK STORAGE SOLUTIONS FOR THE WAY YOU WORK

DEVELOP YOUR SKILLS & GET A REPUTED JOB

KING TONY LIST 2014 CODE DESCRIPTION 1/4"DR SOCKET SETS & ACESSORIES

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

LCD Watch. Figure 1. Views of the inner case of the watch: front (left) and back (right).

EVERYTHING FOR YOUR CAR CAR & CO

Furniture and Fittings Skill Council (FFSC) Summative Assessment Framework

AIR CUSHION TECHNOLOGY

Datasheet RS Pro Tool Cabinet & Tool Module Kit

C764i Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

NZQF NQ Ref 1093 Version 3 Page 1 of 10. This qualification has been reviewed. The last date to meet the requirements is 31 December 2022.

RATHETING TAPS AND DIES SETS RATCHETING TAPS & DIES Pc. Ratcheting Tap and Die Set SAE

FlexClock Z18 USER MANUAL & SETUP GUIDE FLEXCLOCK SERIES 1 MULTI-PURPOSE TIME DEVICE

2. Acquired the know how about the principle of automation. 3. The capability to understand the PLC based systems and machinery.

HOW TO REPLACE A PARKER INVERTER DRIVE WITH A YASKAWA V1000 INVERTER DRIVE

Model Curriculum. Telecom -In-Store Promoter TELECOM HANDSET SALES TEL/Q2101, V1.0 4 SECTOR: SUB-SECTOR: OCCUPATION: REF ID: NSQF LEVEL:

QUALIFICATIONS PACK - OCCUPATIONAL STANDARDS FOR TELECOM INDUSTRY. SUB-SECTOR: Handset (Terminal Applications)

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

SPECIALTY & GENERAL PURPOSE TOOLS

Construction Electrician Apprenticeship Year 3 ELEC 3 Trades Training. Program Outline

Model Curriculum. Telecom Terminal Equipment Application Developer (Native) SECTOR: SUB-SECTOR: OCCUPATION: REF ID: NSQF LEVEL:

Model Curriculum. Field Technician (Computing and Peripherals) SECTOR: SUB-SECTOR: OCCUPATION: REF. ID: NSQF LEVEL:

Chinon PW-600 / PW-610 Power Winder for Chinon cameras

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Installation Manual. BN interface. Model name: BMS-IFBN640TLUL. English

DX4085 Z-Meter Tester

DIGIPLAN presents. Portable Folding Chair. Unfolded View. Folded Side View. 2004/01/02 rev

TOYOTA YARIS HATCHBACK Preparation

Training of Assessors (TOA) Process Note SCOPE: Training of Assessors- RASCI Certified Assessors/ Experienced Assessors/ Fresh Assessors

SYLLABUS FOR PLUMBING & SANITARY TRADE

1000 Park Drive Lawrence, PA Fax

WARNING. General Information

Reservation GT-3; Diploma:28,100/- MBC/DNC-1; Semi Skilled (B) (Boiler Operator) / Semi Skilled (A) (Boiler Operator) SC-1 GT-4; BC-2; BCM-1;

ELECTRICIANS REGULATIONS EXAMINATION 21 November 2015 QUESTION AND ANSWER BOOKLET

15 Channel IR transmitter. Total solder points: 53 Difficulty level: beginner advanced K8049 ILLUSTRATED ASSEMBLY MANUAL

MOBILE WORKSHOP SOLUTIONS

MK-101 TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

INSTALLATION INSTRUCTIONS

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

Principal Industrial Training Institute KURUD Details of Proposed Procurement under Shopping Mode

Contents. Communications, Modular (excludes 17B, 17C, MK 21 and KMB BandMasks ) 1.1 Daily Maintenance. 1.2 Monthly Maintenance (or

MK-MANTA I. Model MK-Manta I Core Drill Owner s Manual Parts List & Operating Instructions. serial number CAUTION

Emax SE SCSI Port Emax Plus Retrofit Instructions (Fl360)

QX Series Cordless Precision Tools. FAQs

Multi-Function Ground Resistance Tester Model 6471

LANCER / LANCER EVOLUTION (2008 ) REAR VIEW CAMERA MZ380462EX INSTALLATION AND HANDLING INSTRUCTIONS

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Fire Fighting Practices Level 1 and 2 FIRE 127 Fire Training Certification. Course Outline

Training of Trainers (TOT) Process Note SCOPE: Training of Trainers - RASCI Certified Trainers/ Experienced Trainers/ Fresh Trainers

Miller Nitro 4000 Series

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

Repair Parts List REFRIGERATOR MODEL NUMBER JFC2089HPY. When requesting service or ordering parts, always provide the following information:

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

Electrical Technology (ELT)

Advanced Manufacturing. and Engineering. Machining (Foundation Knowledge) Level 2 Diploma in. Qualification Specification

Model Curriculum. Community Service Provider SECTOR: SUB-SECTOR: OCCUPATION:

Repair Parts List REFRIGERATOR MODEL NUMBER JFC2089HES. When requesting service or ordering parts, always provide the following information:

Industrial Electrical Apprenticeship Year 3 IELEC3 Trades Training. Program Outline

$2, PC AF & METRIC TOOL KIT 11 DRAWER ROLL AWAY CABINET ATK338. Toolkit Catalogue 2018 Edition. kctools.com.au. since 1975

DynoWare EX+ Upgrade Installation Guide for Motorcycle Dynamometers.

Dual Mount Universal Kit Aftermarket CMOS Camera with Optional Parking Gridlines Installation Instructions (Kit # )

Training of Trainers (TOT) Process Note SCOPE: Training of Trainers - RASCI Certified Trainers/ Experienced Trainers/ Fresh Trainers

Installation Manual - Suntrol STD500LED

1000 Park Drive Lawrence, PA Fax

INSTALLATION INSTRUCTIONS

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)

Repair Parts List REFRIGERATOR MODEL NUMBER MFI2067AEB. When requesting service or ordering parts, always provide the following information:

Transcription:

- () 1. Minimum qualification for Trainers Sector name QP Code Job Role Name Meter Meter Meter Meter Minimum Educational Qualification of the Trainer TOTAL Experience (In Years) required for the Trainer Out of Total Experience, Sector Specific Experience (in years) Out of Total Experience, Teaching Experience (in years) ITI 5 5 0 Diploma 2 2 0 B.E. 1 1 0 B.Tech 1 1 0 Remarks from SSC 2. Minimum required Class room & Lab Size ( in sqft) Sector Job Role / Trade QP code NSQF Job role type Lab Size Remark exception Class room Size level Manufacturing 250 Sq ft 00 Sq ft. Minimum Qualification of Trainees SUNAINA SAMRIDDHI FOUNDATION Page 1

- () 4. Prescribed Duration of the training & common norms category Theory Practical Additional Duration: Entreprene urship and Softskills Additional Duration: Digital Literacy - Not to be counted in total hours - trainee will undergo this on his/her own via online - available in English and Regional Languages at indiaskilsonline.com Training Duration (excluding Digital Literacy) Content Available Comm on Norms Categ ory ClassificationA: Regular Class& lab C: High Capex Training involving Hi capex Manufac turing / Service 100 250 40 20 90 Yes I A NA Manufac turing Technical / Non- Technical Industry visit/ojt - Not applicable (NA) Technical 200 5. Tools & Equipment required in Lab SSC QPCode Job Role Name NSQF Level Equipment Name Minimum number of Equipment required (per batch of 0 trainees) Unit Type Is this a mandatory Equipment to be available at the Training Center (Yes/No) Dimension/Specification/D escription of the Equipment/ ANY OTHER REMARK Double Test Lamp units Yes SUNAINA SAMRIDDHI FOUNDATION Page 2

- () Clamp On Tester Or Clip On Meter To Test Line Current set Yes Multi Meter To Test Continuity And Polarity Of Ct S With The Help Of 1.5 Volt Dc Cell units Yes Accuracy Test With Portable Standard Meter (Accucheck Etc. Optional) 1 unit no Drill M/C With Drill Bit For Mounting Energy Meter And Meter Box units Yes Electrician S Tool Kit Having Combination Plier, Screw Driver 8, 10, Spanner Set, Hammer, Knife, Phase Or Neon Tester, Nose Plier, Hacksaw, Measuring Tape, File Etc. SUNAINA SAMRIDDHI FOUNDATION Page

- () Cable Socket Punch Tool Safety Safety Helmet 2 unit Yes Rubber Gloves 2 pair Yes Safety Belt Or Full Body Harness Spectacle Or Mask And Safety Rubber Boot. Ladder 1 unit Yes Chain 1 unit Yes Rope 1 unit Yes Discharge Rod 1 unit Yes Safety/Danger Sign Boards 1 unit Yes SUNAINA SAMRIDDHI FOUNDATION Page 4

- () Cordon Tape 1 unit Yes Caution & Do Not Operate Tags 1 unit Yes Single Phase Energy Meter (Electronic) units Yes Lt Three Phase Whole Current Energy Meter (Electronic)Of Any Rating Not Above 100 A 2 units Yes Lt Ct Energy Meter Electronic (P4W, X- /5A, X240V) Or Of Any Rating Not Above 100/5A 2 units Yes Lt Ct S Combination Of Or 4 (As Per Meter) Ofany Rating Not Above 100/5A 2 sets Yes Service Cable 1 unit Yes SUNAINA SAMRIDDHI FOUNDATION Page 5

- () Load Like Set Of 100W, 200W Lamps, Heaters, Motors Water Pump Etc. 1 unit Yes Hardware Items Like Screws, Fasteners, Clamps Etc For Fixing Meter Boxes And Cables. (*Tool / Equipment marked not mandatory are optional) SUNAINA SAMRIDDHI FOUNDATION Page 6