Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Similar documents
VAR4. 4x4 DSP Audio Router. Installation Guide. ASL Document Ref.: U doc Issue: 02 complete, approved - Date: 02/12/09 Part Number: M0450_17

Broadband Automatic Disconnect Switch. User Manual

V400. Amplifier Mainframe. Installation Guide. ASL Document Ref.: U doc Issue: 02 complete, approved - Date: 30/11/09 Part Number: M0398_63

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

MPP200 User s Manual

Quick Start Guide and Health and Safety Information

Variable-Speed Vortex Mixer

Vigil 3 Amplifiers. Installation Instructions

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

MPS10 - MPS50. Modular Paging and Emergency Microphones

MPS01. Paging and Emergency Microphone

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

high fidelity engineering since 1974 cd player

EC Series. Safety Guide

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

CMSA-100 Manual. Cinema Media Server Automation

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Installation and Maintenance

Kramer Electronics, Ltd.

Zonit μats TM Users Guide μats1-lv Version 1.2

HX1 Bluetooth Stereo Headset

All company and product names are or Registered Trademarks of their respective owners.

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

icore Kiosk system Installation Guide

Gobo Projector XP 80W

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Rear Cover(CA1-RCVLRG-01) Desktop Stand(CA1-STDLRG-01) Installation Guide

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

903 PORTABLE TEMPERATURE TEST UNIT

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

SP-1400P POWERED SPEAKERS OWNERS MANUAL

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

EVO-TM2A EVO-TM2B Touch Screen Monitor

Chameleon Stand-alone

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Operating instructions Evaluation system for flow sensors VS / / 2013

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

ClockWatch. User Manual. Cueing and Presentation Control Specialists

Installation & Operation Instructions

Slimline CW & WW Series

LED-Illumination with Control Unit Ident.-No

Operating Instructions

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Kramer Electronics, Ltd. USER MANUAL. Model: VM-4HDCP. 1:4 DVI Distributor

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

2-Way Wireless I/O Expander Installation Guide

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Dummy Heavy Duty Camera

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

MPP1700 User s Manual

5 B&W Rear View System Camera

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

9040/9040UK. Users Manual. Phase Rotation Indicator

PSA200 User s Manual

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

S82S (3/7.5-W Models)

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

CS2 DMX Distribution Splitter

Operating Instructions

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

B&W RearView Camera Installation & Operation

CD 3.1x/II CD PLAYER OWNER S INFORMATION

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

MMLG 01, 02, 03, 04 MMLB01

Rack Power Distribution Unit AP7530, AP7540

Installation Instructions

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

Operating instructions. Switching amplifier DN0210 DN / / 2015

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Blitzer RGB Strobe. User Manual. Order code: EQLED365

iq 16 Sync Charge Box

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

JanusRAID SA-6692J Hardware User Manual

Flex-Share Charging Station CSE-1615

dedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes

LVN5200A-R2, rev. 1, Hardware Installation Guide

Ultra Slim Relays 24

MoniCom 15 and 19 User Manual Documentation Version:

SP-1200P POWERED SPEAKERS OWNERS MANUAL

Instruction Manual. Smart (Powered) Hub weatherproof passive RS485 hub and optional power supply V Please check regularly for updates.

RGB Power Batten. User Manual. Order code: EQLED032

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

NI PXI-1042 Series Power Supply Shuttle

V2000. Modular Amplifier Mainframe. Installation Guide

Transcription:

Product Manual ASL Document Ref.: U-0618-0103.doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23 RCS01 RPA Transmitter Charging Station

This equipment is designed and manufactured to conform to the following EC standards: EMC EN50121-4:2006, ENV50204:1996 Safety EN60950:2000 Failure to use the equipment in the manner described in the product literature will invalidate the warranty. A Declaration of Conformity statement to the above standards, and a list of auxiliary equipment used for compliance verification, is available on request. This product must be disposed of in accordance with the WEEE directive. This product is RoHS compliant. Copyright 2008 Application Solutions (Safety and Security) Ltd. Application Solutions (Safety and Security) Ltd. Unit 17 Cliffe Industrial Estate Lewes - East Sussex BN8 6JL - UK Tel: +44(0)1273 405411 Fax: +44(0)1273 405415 www.asl-control.co.uk All rights reserved. Information contained in this document is believed to be accurate, however no representation or warranty is given and Application Solutions (Safety and Security) Ltd. assumes no liability with respect to the accuracy of such information. Page 2 of 24

Contents 1 Description... 5 2 Operation... 6 3 Installation... 7 3.1 Desktop Installation... 7 3.2 Desk Mount Installation... 9 3.3 Wall Mount Installation... 12 4 Maintenance... 15 4.1 Replacing the Mains Power Supply Fuse... 15 4.2 Spare Parts... 16 5 Product Specification... 17 6 Mechanical Dimension... 18 7 Safety and Precautions... 21 7.1 Environmental... 21 7.2 Electrical Safety... 21 7.3 Unpacking and Handling...21 8 Reference Documents... 22 Service and Warranty... 23 Page 3 of 24

This page intentionally left blank. Page 4 of 24

1 Description The RCS01 RPA Transmitter Charging Station is designed to recharge up to four of the RPA01 transmitters simultaneously. From a flat battery it typically takes two hours to recharge the lithium polymer batteries which are built into the RPA01 transmitters. The unit is supplied with two mounting brackets and four rubber feet. It can be fixed to a wall or desk with the mounting plates, or be left free-standing on the rubber feet. DESKTOP (RUBBER FEET) WALL MOUNT (FIXING BRACKETS) DESK MOUNT (FIXING BRACKETS) RPA Transmitter for illustrative purposes only. Page 5 of 24

2 Operation INSERT THE TRANSMITTER FACING FORWARDS. DO NOT FORCE THE TRANSMITTER DOWN. The LED on the RPA Transmitter indicates the charging progress: LID AMBER: Battery is charging. GREEN: Battery is charged. POWER SWITCH Desktop Charging Station shown with 3 empty bays. POWER SUPPLY IEC INLET POWER ON LED Do not place anything in the Charging Station other than the RPA01 transmitter. You might damage the contacts, this may prevent the RPA01 transmitter from charging. Charging a Battery 1. Switch the power supply ON, using the power switch. The power LED illuminates to indicate that the Charging Station is powered on. 2. Lift up one of the charging bay lids, and place the RPA01 transmitter into one of the four bays so that the battery contacts meet the charger contacts. The transmitter should be only inserted with the display and buttons facing towards as shown in the above figure, and must not be forced. 3. The LED on the RPA01 transmitter will illuminate AMBER to indicate that charging is in progress. Charging will usually be completed within two hours. 4. When charging is complete, the LED on the RPA Transmitter will change to GREEN. 5. Lift the RPA01 transmitter out of the charging bay. The protective lid will then drop back down over the charging bay. Page 6 of 24

3 Installation Please read and observe the Safety and Precautions section on page 21 of this manual. 3.1 Desktop Installation Required Tools 4 x rubber feet (supplied). 1 x IEC connector for the power supply cable (supplied). A pozidrive screwdriver No. 2. A medium flat-bladed screwdriver. Installing the Feet Push the four rubber feet supplied into their fixing holes on the base of the charging station. VIEW OF CHARGING STATION BASE FIXING HOLES FIXING HOLES FEET FITTED FEET FITTED Page 7 of 24

Installing the Power Supply Cable 1. Terminate the power supply cable with the IEC connector provided. a. Remove the cover by undoing the fixing screw. b. Remove the rubber grommet, and pass the mains cable though it, observing the correct orientation of the cable. c. Strip the outer sheath and insulation on the cable to the required lengths, making sure the outer sheath of the cable will be held by the cable grip when the connections are made. d. Remove the cable grip by undoing the top two screws. e. Fit the rubber grommet back into position. f. Make the connections to the terminals as follows: Live to terminal marked L Neutral to terminal marked N Earth to terminal marked E or. g. Re-fit the cable grip back into position using the two screws h. Secure the cable in the cable grip by tightening the two screws. i. Re-fit the cover using the fixing screw. The power supply cable must be terminated with the IEC connector provided (BULGIN PX0587) in order for the retaining clip to fit properly. Normal standard mains cabling to fit the supplied IEC connector. N E L IEC 60446 blue brown green&yellow POWER SWITCH OFF 2. Ensure that the power switch on the Charging Station is switched off. IEC320 INLET WITH RETAINING CLIP 3. Plug the power supply cable into the Charging Station, and secure the power cable with the retaining clip. The retaining clip should be fitted in order to prevent accidental removal of the cable. RETAINING CLIP SECURING THE CABLE Page 8 of 24

3.2 Desk Mount Installation Required Tools 2 x desk mounting brackets (supplied). 4 x M4 pozidriv countersunk screws for fixing the brackets to the unit (supplied). Use only the M4 screws provided. Alternative screws must not exceed 8 mm. 1 x IEC connector for the power supply cable (supplied). A pozidrive screwdriver No. 2. A medium flat-bladed screwdriver. Suitable fixings for the unit. A screwdriver, nut spinner, or other appropriate tool to fix the above fixings. Installing the Fixing Brackets Fit the two fixing brackets to the base of the unit using the screws provided. VIEW OF CHARGING STATION BASE BRACKET FIXING HOLES BRACKET FIXING HOLES BRACKET M4 COUNTERSUNK SCREWS BRACKET Countersunk holes to be used for fixing the brackets. Use only the M4 screws provided. Alternative screws must not exceed 8 mm. BRACKET FITTED BRACKET FITTED Page 9 of 24

Installing the Unit on the Desk 1. Mark the surface on which the Charging Station will be fitted. The unit has four fixing holes on 60 mm x 450 mm centres. See Figure 2 for further details. FIXING HOLES VIEW OF CHARGING STATION BASE FIXING HOLES 60 mm 450 mm 2. Prepare the mounting holes appropriately. 3. Fix the Charging Station to its mounting position using the selected fixings and appropriate tools. Page 10 of 24

Installing the Power Supply Cable 1. Terminate the power supply cable with the IEC connector provided. a. Remove the cover by undoing the fixing screw. b. Remove the rubber grommet, and pass the mains cable though it, observing the correct orientation of the cable. c. Strip the outer sheath and insulation on the cable to the required lengths, making sure the outer sheath of the cable will be held by the cable grip when the connections are made. d. Remove the cable grip by undoing the top two screws. e. Fit the rubber grommet back into position. f. Make the connections to the terminals as follows: Live to terminal marked L Neutral to terminal marked N Earth to terminal marked E or. g. Re-fit the cable grip back into position using the two screws h. Secure the cable in the cable grip by tightening the two screws. i. Re-fit the cover using the fixing screw. The power supply cable must be terminated with the IEC connector provided (BULGIN PX0587) in order for the retaining clip to fit properly. Normal standard mains cabling to fit the supplied IEC connector. N E L IEC 60446 blue brown green&yellow POWER SWITCH OFF 2. Ensure that the power switch on the Charging Station is switched off. IEC320 INLET WITH RETAINING CLIP 3. Plug the power supply cable into the Charging Station, and secure the power cable with the retaining clip. The retaining clip should be fitted in order to prevent accidental removal of the cable. RETAINING CLIP SECURING THE CABLE Page 11 of 24

3.3 Wall Mount Installation Required Tools 2 x desk mounting brackets (supplied). 4 x M4 pozidriv countersunk screws for fixing the brackets to the unit (supplied). Use only the M4 screws provided. Alternative screws must not exceed 8 mm. 1 x IEC connector for the power supply cable (supplied). A pozidrive screwdriver No. 2. A medium flat-bladed screwdriver. Suitable fixings for the unit. A screwdriver, nut spinner, or other appropriate tool to fix the above fixings. Installing the Fixing Brackets Fit the two fixing brackets to the rear of the unit using the screws provided. VIEW OF CHARGING STATION REAR FIXING HOLES FIXING HOLES BRACKET M4 COUNTERSUNK SCREWS BRACKET Countersunk holes to be used for fixing the brackets. Use only the M4 screws provided. Alternative screws must not exceed 8 mm. BRACKET FITTED BRACKET FITTED Page 12 of 24

Installing the Unit on the Wall 1. Mark the surface on which the Charging Station will be fitted. The unit has four fixing holes on 60 mm x 450 mm centres. See Figure 3 for further details. FIXING HOLES VIEW OF CHARGING STATION REAR FIXING HOLES 60 mm 450 mm 2. Prepare the mounting holes appropriately. 3. Fix the Charging Station to its mounting position using the selected fixings and appropriate tools. Page 13 of 24

Installing the Power Supply Cable 1. Terminate the power supply cable with the IEC connector provided. a. Remove the cover by undoing the fixing screw. b. Remove the rubber grommet, and pass the mains cable though it, observing the correct orientation of the cable. c. Strip the outer sheath and insulation on the cable to the required lengths, making sure the outer sheath of the cable will be held by the cable grip when the connections are made. d. Remove the cable grip by undoing the top two screws. e. Fit the rubber grommet back into position. f. Make the connections to the terminals as follows: Live to terminal marked L Neutral to terminal marked N Earth to terminal marked E or. g. Re-fit the cable grip back into position using the two screws h. Secure the cable in the cable grip by tightening the two screws. i. Re-fit the cover using the fixing screw. The power supply cable must be terminated with the IEC connector provided (BULGIN PX0587) in order for the retaining clip to fit properly. Normal standard mains cabling to fit the supplied IEC connector. N E L IEC 60446 blue brown green&yellow POWER SWITCH OFF 2. Ensure that the power switch on the Charging Station is switched off. IEC320 INLET WITH RETAINING CLIP 3. Plug the power supply cable into the Charging Station, and secure the power cable with the retaining clip. The retaining clip should be fitted in order to prevent accidental removal of the cable. RETAINING CLIP SECURING THE CABLE Page 14 of 24

4 Maintenance There are no routine maintenance tasks for the Charging Station, except for mains supply fuse replacement when required, and occasional removal of any dust or debris, which may have fallen into the charging bay. 4.1 Replacing the Mains Power Supply Fuse Please read and observe the Safety and Precautions section on page 21 of this manual. FUSE DRAWER 2 x T 1A L 250V 1. Ensure that the power switch on the Charging Station is switched off. 2. Disconnect the power supply cable. 3. Pull out the fuse drawer, located with the IEC inlet at the left side of the Charging Station. 4. Check that the fuses are intact, and then replace them if required. Replace with type T 1A L 250V. Page 15 of 24

4.2 Spare Parts ASL Part Number Additional Information 207635 IEC Female Connector for Power Supply Cable 1 Manufacturer/Supplier: Bulgin Manufacturer/Supplier Part No.: PX0587 Manufacturer/Supplier Description: Straight female connector, rewirable. K0618003 RCS01 Charging Station Fixing Kit Manufacturer/Supplier: Application Solutions (Safety and Security) Ltd. Manufacturer/Supplier Part No.: K0618003 Manufacturer/Supplier Description: 4 rubber feet, 2 wall-mount bracket and screws, IEC Female Connector for Power Supply Cable 1 This connector type must be used in order for the retaining clip to work properly. Page 16 of 24

5 Product Specification General Power Supply...100 V 240 V AC, 47 Hz 63 Hz Current... 0.5 A Fuse Rating...T 1A L 250 V Capacity...up to 4 RPA01 Radio Microphones Flat Battery Recharging Time...2 hours (typical) Connector...IEC inlet Format... Metal case, plastic charging bays Colour Case and Brackets...Grey with white annotation Low Smoke and Fume, Zero Halogen Charging Bays...Black Environmental Temperature (Storage and Operating)... 5 C to +50 C Humidity Range...0% to 93% Non-condensing Safety and EMC EMC...EN50121-4:2006, ENV50204:1996 Safety... EN60950:2000 Dimensions and Weight Desktop Mount (including feet, excluding retaining clip) Dimensions (H x W x D)...90 mm x 424 mm x 100 mm Weight...2 kg Desk Mount (including brackets, excluding retaining clip) Dimensions (H x W x D)...85 mm x 474 mm x 100 mm Weight...2.2 kg Wall Mount (including brackets, excluding retaining clip) Dimensions (H x W x D)...85 mm x 474 mm x 102 mm Weight...2.2 kg Page 17 of 24

6 Mechanical Dimension Figure 1 Desktop Charging Station 90 mm 84 mm 78 mm 19 mm 419 mm 414 mm 376 mm BACK VIEW FRONT VIEW BOTTOM VIEW THIRD ANGLE PROJECTION 100 mm 98 mm 78 mm 90 mm 84 mm 78 mm 10 mm 424 mm RCS01 RPA Transmitter Charging Station STATUS INDICATOR AMBER: CHARGING GREEN: CHARGED power Page 18 of 24

Figure 2 Desk Mount Charging Station 85 mm 80 mm 12 mm 474 mm 419 mm 414 mm 450 mm BACK VIEW FRONT VIEW BOTTOM VIEW 100 mm 98 mm 60 mm 9.4 mm RCS01 RPA Transmitter Charging Station STATUS INDICATOR AMBER: CHARGING GREEN: CHARGED power 85 mm 80 mm 78 mm 78 mm 50 mm 60 mm 424 mm THIRD ANGLE PROJECTION 78.8 mm Page 19 of 24

Figure 3 Wall Mount Charging Station 12 mm 450 mm 474 mm 419 mm 414 mm 100 mm 98 mm 60 mm 9.4 mm RCS01 RPA Transmitter Charging Station STATUS INDICATOR AMBER: CHARGING GREEN: CHARGED power BACK VIEW FRONT VIEW BOTTOM VIEW 78.8 mm 85 mm 78 mm 85 mm 78 mm 50 mm 60 mm 424 mm THIRD ANGLE PROJECTION 102 mm Page 20 of 24

7 Safety and Precautions 7.1 Environmental Always ensure adequate ventilation is provided for the equipment and do not obstruct ventilation holes. The temperature and humidity ranges shown in the specifications for this product must not be exceeded. This equipment must not be installed in an area that is subject to a corrosive atmosphere, excessive moisture or may allow water or other liquids to come into contact with the unit or its external connections. 7.3 Unpacking and Handling The equipment should be unpacked and inspected immediately on receipt. If damage has occurred please advise your carrier or supplier. It is advisable to retain the original equipment packing in the event that the equipment ever needs returning for service. Ensure that the name and address of the Authorised Distributor from whom you purchased the unit is recorded on the Service and Warranty page of this manual for future reference. Advice on packing the product for return can be provided by Application Solutions (Safety and Security) Ltd.. 7.2 Electrical Safety This product contains wiring that is energised to 230 V RMS AC mains. Always ensure that the equipment is correctly earthed by connection to an AC mains supply with a protective earthing connection. Ensure power supply cabling is adequately rated for the unit s operating current and protected, in case of short circuit, by a correctly rated fuse or circuit breaker. Always replace blown fuses with the correct type and rating. Page 21 of 24

8 Reference Documents Additional reference information may be found in the following documentation, available from the Data Downloads page of Application Solutions (Safety and Security) Ltd. website: www.asl-control.co.uk Table 1 Reference Documents Ref. No Title Filename Ref Origin 1 RPA01 Transmitter Product Manual U-0618-0103 ASL 2 SAP01 Product Manual U-0464-0414 ASL 3 SAP02 Product Manual U-0464-0454 ASL Page 22 of 24

Service and Warranty Name and Address of Authorised Distributor: This product carries a full warranty. For full details of warranty and service agreements, please contact the Authorised Distributor who supplied the product to you. Exclusions The warranty does NOT cover: 1. Customer misuse, including incorrect installation. 2. Damage other than manufacturing defects. 3. Transit / Courier damage. 4. Incorrect voltage or power supply used. 5. Incorrect input signal. 6. Abnormal environmental operating conditions. 7. Damage incurred by accident, fire, lightning or other hazard. 8. Modification to the unit or inexpert / attempted repair. 9. No fault found where no fault can be found after extensive testing, indicating user error or failure in ancillary equipment. 10. Electronic assemblies which are improperly packed when returned for repair or service. Should any of the above apply, Application Solutions (Safety and Security) Ltd. reserves the right to raise any relevant charges to the customer. Application Solutions (Safety and Security) Ltd. shall not be liable for any indirect, special or consequential loss or damage (including without limitation any loss of profits) arising from the use of this product or for any breach of this warranty. In the interest of continual product development, Application Solutions (Safety and Security) Ltd. reserves the right to make changes to product specification without notice or liability. Page 23 of 24