VISTA-10SE, VIA-30PSE, VISTA-20SE E2 ZONE PROGRAMMING. An Improved Zone Programming and 5800 Wireless Device Enrollment Procedure

Similar documents
ADEMCO VISTA-48A Security Systems

First Alert FA160C/162C Installer Notes M. Leuck

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

ADEMCO LYNXR-ENSIA Security System

Ademco/Protection One 250P1-1 Programming Form

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

CUSTOMER INFORMATION

Ademco Vista-20SE/First Alert FA-162C Program Sheet

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

LYNX Security System 3URJUDPPLQJ)RUP 6XPPDU\RI&RQQHFWLRQV. Features Q.E.D. programming for quick enrollment of devices.

For use with QED controls panels ONLY

5HDG\*XDUG56HULHV 6H XULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU5HDG\*XDUG5DQG 5HDG\*XDUG5(1 K /01 OFF AWAY STAY AUX

VISTA-50P VISTA-50PUL

Property of Monitronics Inc

For use with QED and hardwired control panels ONLY!

Property of Monitronics Inc

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

INSTALLATION INSTRUCTIONS

APX32EN Security Systems

Installation Instructions

4140XMPT2 PROGRAMMING FORM

Property of Monitronics Inc

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

High Security and Access System EVO48 V2.1 EVO192 V2.1

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

Quick Start: 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 44).

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

VISTA-128BP/VISTA-250BP Programming Form

Lynx Plus Security System

IDS X-Series User Manual E Issued June 2013

DSC programming for the Alexor and Impassa

Telephone and Reporting Setup in ElkRP

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA

Digiplex EVO High Security and Access System What s New EVO192 V2.7

2 IDS LCD Keypad User Manual C Issued March 2009

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

Modules Programming Guide. paradox.com

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NX-148 LCD KEYPAD INSTALLATION MANUAL

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

NetworX Series NX-8V2 Control Panel Installation and Startup

Series. NX-8-EUR Control Panel. Installation manual

Honeywell Total Connect enables notifications and control via the Web, , or Phone from a Remote Location

EVOHD. Programming Guide. Version

GEM-P9600 CONTROL PANEL/COMMUNICATOR

Important Notice. Customer Information. 2 WisDom User Manual

VISTA-40. Programming Guide. 2-Partition Security System. Single Partition and 2-Partition Programming Forms N7001PRV4 7/98

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

Modules Programming Guide

QUICK CONSUMER REFERENCE GUIDE

Installation Manual IMPORTANT NOTE

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG/SP Series (V4.9/V5.1) What s New

REMOTE KEYPAD with NFC Tag (KPT-32N, KPT-32N-F1)

VISTA-50PADT VISTA-50PADTUL

Programming Worksheets

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Programming Default Tables

SECURITY MODULE CG3 User Manual

Control Panel. D9412GV4/D7412GV4/D7212GV4 v1.xx. Release Notes

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

Installation Manual GENERAL DESCRIPTION...2 WIRING INFORMATION FOR NX-507 AND NX NX-507 TERMINAL DESCRIPTION...3 NX-507 DRAWING...

GEM-RP3DGTL Digital Keypad

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

NX-1248E LCD KEYPAD Installation and Setup

July Domonial Wireless Alarm System TCPA Keyfobs

User Guide. K V1 7/05 Rev A

INT-KSG Keypad Quick user s guide

DAS LCD ALPHA NUMERIC CODEPAD

Agility Installation Quick Start Guide 1

Keypad LCD (software version 3.10) CA-10 plus

XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

PC4164 v2.1 Installation Manual

PROGRAMMING AND INSTALLATION MANUAL

Colour Graphic Terminal User Manual. Rev 3.1

TABLE OF CONTENTS. Service Access and Commands... 78

Integrating the HouseLogix Honeywell Integration Module with Control4

Solution 16 plus. User Guide Security System

NX-2192E PINPOINT SYSTEM

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

NetworX Series NX-216 Zone Expander Installation and Startup

Includes: 413oxM 513oxM 414oxM 414oxMP

XT30/XT50 OVERVIEW. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training System Overview. XT30/XT50 Description

Property of Monitronics Inc

D1260/D1260B. Owner's Manual. Keypad

Solution 144 Security Systems

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual

Configuring Honeywell Vista Alarm Panels Using the HSIM Interface Module Integration Release Notes

Transcription:

K4240V2 Ê9/99Ê INSTALLATION SUPPLEMENT VISTA-0SE, VIA-30PSE, VISTA-20SE E2 ZONE PROGRAMMING An Improved Zone Programming and 5800 Wireless Device Enrollment Procedure Important! Replace the existing procedures in your Installation Instructions with these instructions Control Panels Affected Vista-0 SE family Via-30P SE Vista-20 SE family Summary of Changes Enhanced 56 Zone Programming Mode Combined transmitter Serial number and Loop number entries on one screen. Provided the ability to enter transmitter serial number, loop number, and confirmation in one step by transmitting multiple times. Added a message to indicate that you are in a Confirmation Mode. Added the ability to copy the serial number from a previously entered zone (for multiple zone transmitters), and then edit the loop number. Added the ability to edit and delete a serial number at the input serial number prompt. Removed the use of a Òprogram tooló for programming transmitters Added 58 Expert Programming Mode The new Expert Mode allows you to: Program zone attributes on a single screen. Copy zone attributes from the last zone saved. Copy a serial number from the last serial number saved. Edit and delete a serial number at the input serial number prompt. Enroll wireless keys using pre-defined default templates. Removed 83 Sequential Mode From System ARMED The 639 Alpha keypad used for programming is shown at the right. Note the locations of the A, B, C, and D keys in particular, which are used in conjunction with other keys during programming. READY A B OFF AWAY STAY 2 3 MAX TEST BYPASS 4 5 6 C INSTANT CODE CHIME 7 8 9 D READY * 0 PANIC #

56 Zone Programming (Revised) Note: Before proceeding, you must program field 22 (RF System) and field 25 (Wired Zone Expansion) as required. In the programming mode, key 56. SET TO CONFIRM? 0 = NO = YES 0 Enter Zn Num. (00 = Quit) 0 ÊÊÊ Zone 0 entered i ZnÊÊZTÊÊPÊÊRCÊÊÊIn:ÊÊÊÊL 0ÊÊ00ÊÊÊÊÊ0ÊÊÊRF:ÊÊ Ð mzone Number 0 Zone Type Perimeter 03 Zone Type i 0 Partition 0 Report Code st 0 2nd 00 0. This display will appear upon entry into 56 mode. The default is 0 (No). If (Yes) is entered, you will be prompted to confirm each transmitter after entering the serial and loop numbers (at the ÒXMIT TO CONFIRMÓ prompt later in this procedure). 2. Zone Number (Zn): Enter the zone number that you wish to program. Press to continue. 3. A summary display appears, showing the status of that zoneõs programming. Note: The summary will only display partition (P) number if your control panel has partitions. Press to continue. 4. Zone Type (ZT): Enter the Zone Type response (or change it, if necessary). Refer to your Installation Instructions for zone types available. Note: If Ò00Ó is entered, ÒDelete Zone?Ó will be displayed. After entering the Zone Type, press [ ] to continue. 5. Partition No. (P):ÊEnter the Partition number (if applicable to your control panel). Partition is shown entered. Press to continue. 6. Report Code (RC): Enter the report code. This consists of 2 hexadecimal digits, each in turn consisting of 2 numerical digits. For example, for a report code of Ò0Ó, enter 0 and 00. Refer to the System Communication section of your Installation Instructions for more information about report codes and report code formats. It should be noted that report codes are factory defaulted to Ò0Ó for use with CID reporting. Press to continue. 0 INPUT TYPE RF TRANS ÊÊÊ 3 0 INPUT S/N: ÊÊÊÊÊ ÊL A022-4064 ÊÊÊ Note: The ÒAÓ and ÒBÓ keys may be used to move the cursor to the right (A) or left (B) within the serial number field, thus allowing you to correct any entry errors that may have been made. 7. Enter Input Device type (In). Used for Input Type entry. 2 = AW (Aux wired zone), 3 = RF (supervised RF transmitter, 4 = UR (unsupervised RF transmitter), 5 = Button type RF transmitter (unsupervised). Note: For the built-in hardwired zones, the Input Device type is automatically displayed as HW and cannot be edited. Response time entry (RT) will be available for hardwired zones Ð8 on Vista-20SE series. Press to continue. 8. Serial Number Entry and Loop Number Entry. Used only when enrolling wireless transmitters. a. Transmit two open and close (or close and open) sequences. For a buttontype transmitter, press and release the button, wait approximately 4 seconds, then press and release the button a second time. OR b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the Alpha keypad. Then press the [ ] key Ñ the cursor will move to the ÒLÓ position. You can edit the loop number, if necessary. When the loop number is acceptable, press [ ]. OR c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several input loops). 2

0 INPUT S/NÊÊÊÊÊ ÊL ÊÊÊA022-4064 Ê ÊÊ? 0 INPUT S/N ÊÊÊÊÊ ÊL ÊÊÊÊA022-4064 Ê Ê XMIT TO CONFIRM PRESS TO SKIP If Serial Numbers k do not match after activating the transmitter The cursor will then move to the Loop column (L) with the previous serial number displayed, and display a highlighted question (?) mark for the loop number. Enter the loop number and press. The system will then check for a duplicate serial/loop number combination. If a duplicate serial/loop number combination is found, the keypad will emit a single long beep, and prompt with a Ò?Ó again for a different loop entry. If serial/loop number combination is not a duplicate in the system, a display showing the serial number and loop number entry will appear. Press to continue. 9. Confirmation Option: This prompt will only appear if you answered ÒYesÓ in step. The system will enter a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate the loop input or button that corresponds to this zone. If the serial number/loop number combination transmitted does not match the serial number entered, a display similar to the one below will appear. Entd A022-4063 ÊÊÊ2 Rcvd A022-4064 2 If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key twice and then enter or transmit the correct serial number again. To Delete a Serial No.k To delete an existing serial number, enter Ò0Ò in the loop number field. The serial number will change to Ò0Ós. 0 INPUT S/N: Ê ÊÊÊ ÊÊÊÊ L ÊÊÊÊA000-0000ÊÊ Ê ÊÊ0 If Ò0Ó was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the display. ZnÊÊZTÊÊPÊÊRCÊÊIn:Ê L 0ÊÊ03ÊÊÊÊ 0ÊÊÊRF: s If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and a summary display will appear, showing that zone's programming. Note that an ÒsÓ indicates that a transmitterõs serial number has been enrolled. Press to accept the zone information and display the ÒPROGRAM ALPHA?Ó prompt. PROGRAM ALPHA? 0 = NO = YES 0 ENTER ZN NUM. (00 = QUIT) 0. If you want to program alpha descriptors for zones now, enter (Yes). If not, enter 0 (No). Refer to the Alpha Descriptor Programming section in your Installation Instructions for information on programming zone descriptors.. If ÒNoÓ is entered above, the system will return you to the ÒENTER ZN NUM.Ó prompt for the next zone. When all zones have been programmed, enter Ò00Ó to quit. When you have finished programming all zones, test each zone using the systemõs TEST mode. Do not use the Transmitter ID Sniffer Mode for checking wireless transmitting devices, as it will only check for transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop. NOTE: Following the successful enrollment of each wireless device, remove ONE of the serial number labels from the device and affix it in the appropriate column on the worksheet on page 9; then enter the other information (zone number, loop number, zone type, etc.) relevant to that device. See the following pages for Expert Mode Ñ 3

e?e??ee??ee??e e?e??ee??ee??e h? h? h? h? h? h???ee??ee??e??ee??ee??e e?e??ee??ee??e e?e??ee??ee??e h? h? h? h? h? h???ee??ee??e??ee??ee??e Summary of Expert Mode ( 58) The following is a summary of the Expert Mode in the form of a flow chart. Step-by-step instructions for the Expert Mode start on the next page. SET TO CONFIRM? 0 = NO = YES 0 Zn ZT P RC In: L 0 09 0 HW Ð IN = HW or AW g g g g g g 0 INPUT S/N L AXXX-XXXX No???????? IN = RF, BR, or UR Zn ZT P RC In: L 09 0 RF Ð g g g g g g Is Confirm Bit Set? Yes Confirm by transmission???????? Question is asked once upon entering the Expert Mode Default is ÒNoÓ If ÒYesÓ, Confirmation prompts will be displayed later Enter desired zone number and press Note: ÒRTÓ will appear in place of ÒLÓ for VISTA-20SE type control panel Enter all information except for Loop number Use ÒAÓ (forward) and ÒBÓ (back) keys to move cursor within the screen Press ÒCÓ key (with cursor under ÒZTÓ) to copy the last enrolled zoneõs attributes Press ÒDÓ key (with cursor under Zn) to enter and duplicate wireless keys Ð skip to chart for ÒDÓ keys that follows Press to accept existing information Press [#] to back up without saving For wireless zones, enter serial and loop number, either manually, or by two open and close (or close and open) sequences. On button type transmitters, press the button twice, but wait approximately 4 seconds before pressing the button the second time. To copy a previous zoneõs serial number, press the ÒCÓ key Ð then enter loop number Use ÒAÓ and ÒBÓ keys to move cursor within screen Press to accept existing serial and loop number System checks for duplicate If a duplicate exists (long error beep), press [#] to back up without saving and re-enter serial and/or loop number Prompt to confirm appears if YES was answered to first prompt To confirm, activate loop input or button that corresponds to this zone If serial number entered matches serial number transmitted, the system will advance to the summary display for the next zoneõs programming If the ÒDÓ key is pressed, the following screens will appear: TEMPLATE? Ð6 L 0 02 03 04 T 23 22 2 23 PARTITION INPUT S/N AXXXÐXXXX ENTER START ZONE 00 = QUIT XX No Is Confirm Bit Set? Yes Confirm by transmission Zn ZT P RC In: L 09 0 RF Ð Enter Template number Select from 6 templates (Ð3 = 5804, 4Ð6 = 5804BD) Press to display template Press [#] to return to zone attributes screen Selected template is displayed Top line of display represents loop number, bottom line represents zone type or function Press to accept template Press [#] to back up and re-enter template number Enter partition number (if applicable) for wireless key Enter desired starting zone number System searches for highest consecutive 4-zone group available, starting with the desired zone entered. If not found, the first (lowest zone number) of any four available consecutive zones will be displayed. Press to accept Enter serial number for the wireless key or press any button on the key. Press to accept existing serial number System checks for duplicate If duplicate exists (long error beep), press [#] to back up without saving and re-enter serial and/or loop number Use the [A] key to move forward within the screen Use the [B] key to move backward within the screen Prompt to confirm appears if YES was was answered to first prompt To confirm, activate button that corresponds to this zone If serial nnumber entered matches serial number entered, the system will advance to the summary display for the next zone to be programmed 4

58 Expert Programming Mode (Step-By-Step Procedure) This method is designed for use by installers with previous experience in programming Ademco control panels. Enter the program mode and follow the step-by-step instructions that follow. Note: Before proceeding, you must program field 22 (RF System) and field 25 (Wired Zone Expansion) as required. SET TO CONFIRM? 0 = NO = YES 0 ÊÒRTÓ displayed here ÊÊfor VISTA-20 SE m Zn ZT P RC In:Ê Ê ÊL 0ÊÊ 09ÊÊ ÊÊ0Ê ÊHW:ÊÊÐ Zn ZT P RC In:ÊÊ L ÊÊ ÐÊ Ð Ð ÐÊ:Ê Ð Zn ZT P RC In:ÊÊ L 0 00Ê 0 RF:Ê * If HW (hardwired) or AW Auxiliary) is entered for Input Device Type, the next screenwill be similar to the above, except that HW or AW will be displayed under ÒIn.Ó If RF, BR, or UR is entered, a prompt for Serial and Loop number will be displayed, as below. 0 INPUT S/N: ÊÊÊÊÊ ÊL ÊÊÊÊAXXX-XXXX Ê Ð 0 INPUT S/N: ÊÊÊÊÊÊ ÊL ÊÊÊA022-4064 ÊÊÊÊ. Key 58. This display will appear upon entry into this mode. The default is 0 (No). If (Yes) is entered, you will be prompted to confirm each transmitter after entering the serial and loop numbers (see ÒXMIT TO CONFIRMÓ prompt on the next page). A summary screen will appear, showing zone ÒÓÕs current programming or default values. 2. If you want to use a Template to enter a wireless key, press the [D] key and go to the instructions on the following page under the title ÒEntering and Duplicating Wireless Keys.Ó When the [D] key is pressed, a special prompt will be displayed which offers a series of default templates for wireless keys. Otherwise, enter the first digit of the zone number to be programmed, as shown at left. 3. Enter the 2nd digit of the zone number to be programmed (in the example on the left, zone 0 has been entered). The display will show that zoneõs current programming. Press [ ] to continue. 4. The attributes for the zone must now be entered, Zone Type [ZT], Partition [P] if applicable, Report Code [RC] and Input Device Type [ I n] *. If desired, you can use the [C] key to copy the attributes and/or serial No. from the last enrolled zone (assuming you have previously enrolled at least one zone), or you can enter the attributes manually as follows: Enter Zone Type (ZT), Partition (P) if applicable, Report Code (RC), and Input Device Type (In)* sequentially, but not the Loop No. (L). Use the [A] (Advance) and [B] (Back) keys on the keypad to move the cursor within the screen. 5. Press if the existing information is acceptable. If not, you can press the [#] key to back up without saving, and make any necessary changes. 6. Serial Number Entry and Loop Number Entry. Used only when enrolling wireless transmitters. a. Transmit two open and close (or close and open) sequences. For a buttontype transmitter, press and release the button, wait approximately 4 seconds, then press and release the button a second time. OR b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the Alpha keypad. Then press the key Ñ the cursor will move to the ÒLÓ. You can edit the loop number, if necessary. When the loop number is acceptable, press. OR c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several input loops). 7. Press to advance to the loop number, then enter loop number. 8. Press To accept the existing serial and loop number. If necessary, press [#] to back up and re-enter or edit the serial number before pressing to save. The system checks for duplicate. If a duplicate exists, a long error beep will sound. Press [#] to backup and re-enter the serial and/or loop number. 5

To Delete a Serial No.k To delete an existing serial number, enter Ò0Ò in the loop number field. The serial number will change to Ò0Ós. 0 INPUT S/N: Ê ÊÊÊÊÊÊÊ L ÊÊÊÊ A000-0000ÊÊ ÊÊÊ0 If Ò0Ó was entered in error, simply re-enter the loop number, and the serial number will return to the display. Press [ ] to accept. 0 XMIT TO CONFIRM PRESS TO SKIP EntdÊÊA022-4063Ê 2 Rcvd ÊA022-4064Ê 2 Zn ZT P RC In:ÊÊ L 00Ê 0 RF:Ê Ð 9. The prompt to confirm appears. This prompt will only appear if you answered ÒYesÓ in step. To confirm, activate the loop input or button that corresponds to this zone. If the serial/loop number combination transmitted does not match the serial and loop number entered, a display similar to the one at left will appear. If so, activate the transmitterõs loop input or button one or more times. If a match is still not obtained (i.e., summary display does not appear), press the [#] key and enter the correct loop input or, if correct, press [#] again and then enter the correct serial number. If the serial number transmitted matches the serial number entered, the system will beep 3 times and advance to the summary display for the next zoneõs programming. NOTE: Following the successful enrollment of each wireless device, remove ONE of the serial number labels from the device and affix it in the appropriate column on the worksheet on page 9; then enter the other information (zone number, loop number, zone type, etc.) relevant to that device. Entering and Duplicating Wireless Keys If the D key was previously pressed to enter and duplicate 5804 and/or 5804BD wireless keys, the following screens will appear: TEMPLATE Ê? Ð6 L = Loop No. LÊÊÊ0ÊÊ02ÊÊ03ÊÊ04 TÊÊ 23ÊÊ22ÊÊ2ÊÊ23 T = Zone Type PARTITION ÊÊ ENTER START ZONE 00 = QUIT 22 Example of zone i suggested by the system. This indicates that zones 22, 23, 24, & 25 are available.. Enter Template number (Ð6). Ð3 = 5804 templates; 4Ð6 = 5804BD templates. See the defaults provided for each template in the chart that follows these procedures. 2. Select from templates. Press [ ] to display template ( shown selected). Note: If necessary, press [#] to back up and re-enter template number. 3. Press [#] if you want to return to zone attributes screen. 4. When [ ] is pressed, the selected template will be displayed. Top line of display represents loop numbers, bottom line represents zone type assigned for each zone. 5. Press to accept template. 6. Enter Partition number (if applicable) for wireless keys. Press to continue. 7. The system will search for the highest available, consecutive 4-zone group, (the four zones required for the 5804 and 5804BD), and display the lowest zone number of the group. If you want to start at a different zone, enter the zone desired, and press. If that zone number is displayed, the system has the required number of consecutive zones available, beginning with the zone you entered. If not, the system will again display a suggested zone that can be used. If the required number of consecutive zones is not available at all, the system will display Ò00Ó. 8. Press to accept. 6

INPUT S/NÊÊÊÊÊÊÊÊÊÊÊÊÊÊÊL AXXX-XXXXÊÊÊÊÊÊÊÊÊÊ ÊÐ XMIT TO CONFIRM PRESS TO SKIP Entd A022-4063Ê Ð Rcvd A022-4064Ê 9. Press and release a button on the wireless key. OR Enter the serial number printed on its label. 0. Press to accept the serial number. The system will check for duplicate.. If necessary, press the [#] key to back up without saving, and re-enter the serial number. Use the [A] key to move forward within the screen, and the [B] key to move backward. 2. If ÒYesÓ was entered at the SET TO CONFIRM prompt previously (see first prompt following entry into the 58 Expert Programming Mode), the display on the left will appear. Confirm serial and loop numbers by activating the wireless key. 3. If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and you will then be returned to step 6 to enter the starting zone for the next wireless key. If the serial number transmitted does not match the serial number entered, a display similar to the one at the left will appear. If so, activate the loop input or button on the transmitter once again. If a match is not obtained, press the [#] key and then enter the correct serial number. NOTE: Following the successful enrollment of each wireless device, remove ONE of the serial number labels from the device and affix it in the appropriate column on the worksheet on page 9; then enter the other information (zone numbers, loop numbers, zone types, etc.) relevant to zones for that device. GREEN/YELLOW LED GRE GREEN/YELLOW LED RED/YELLOW RED/YELLOW LED LED BUTTON A3 BUTTON 2 B BUTTON 4 C (YOU MUST PROGRAM THIS BUTTON) BUTTON D ENROLL AS "BR" 5804BD FRONT VIEW 5804BD 2-Way Wireless Key Transmitter Note: These transmitters are not intended for use in UL installations. YOU PROGRAMME MUST PROGRAM THIS BUTTON THIS 4 BUTTON ( 4) Ê ENROLL AS "BR" 3 3 2 2 5804 Wireless Key Transmitter For 5804 Wireless Key Pre-Defined Default Templates For 5804BD TEMPLATE Loop Function Zone Type TEMPLATE 4 Loop Function Zone Type No Response 23 No Response 23 2 Disarm 22 2 No Response 23 3 Arm Away 2 3 Arm Away 2 4 No Response 23 4 Disarm 22 TEMPLATE 2 Loop Function Zone Type TEMPLATE 5 Loop Function Zone Type No Response 23 No Response 23 2 Disarm 22 2 Arm Stay 20 3 Arm Away 2 3 Arm Away 2 4 Arm Stay 20 4 Disarm 22 TEMPLATE 3 Loop Function Zone Type TEMPLATE 6 Loop Function Zone Type 24-hour Panic 07 24-hour Panic 07 2 Disarm 22 2 Arm Stay 20 3 Arm Away 2 3 Arm Away 2 4 Arm Stay 20 4 Disarm 22 7

5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones). Transmitter inputs entered as: "RF" (Supervised RF) Type send periodic check-in signals, as well as fault, restore and low battery signals. The transmitter must remain within the receiver's range. ÒUR" (Unsupervised RF) Type send all the signals that the "RF" Type does, but the control does not supervise the check-in signals. The transmitter may, therefore, be carried off-premises. "BR" (Unsupervised Button RF) Type only send fault signals. They do not send restore or check-in signals. They will indicate a low battery condition when tested or activated normally. The transmitter may be carried offpremises. 3 2 580 ENROLL AS "UR" OR "RF" 4 YOU MUST ENROLL THIS BUTTON 5802MN ENROLL AS "UR" OR "RF" ALTERNATE POSITION FOR 2 2 (REED) (TERMINALS) 586MN 587 (PRIMARY) 2 (AUX. CENTER) 3 (AUX. RIGHT) YOU MUST ENROLL THIS BUTTON 4 5804 ENROLL AS "BR" 3 2 2 YOU MUST ENROLL THIS BUTTON 4 2 (REED) 3 (TERMINALS) 589 (TERMINALS) 2 (REED) 3 (TERMINALS) 589S (WHS & BRS) (INTERNAL SHOCK SENSOR) 3 5804BD ENROLL AS "BR" SET HOUSE CODE 5827 SET HOUSE CODE 5827BD SET HOUSE CODE 5809 2 (REED) (TERMINALS) (Green) (Red) (Yellow) (MOTION) 5808 586 5850 (GBD) 5890 NOTE: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc. UL NOTE: The following transmitters are not intended for use in UL installations: 5802MN, 5802MN2, 5804, 5804BD, 584, 586TEMP, 589, 589WHS & BRS, 5827BD, and 5850. 8

USE THIS WORKSHEET FOR ZONE PROGRAMMING PARTITION SERIAL No. (if applicable) ZONE ZONE No. INPUT Affix Serial No. Label. No. TYPE (If applicable) TYPE from Transmitter Here No. DEVICE LOCATION 9

USE THIS WORKSHEET FOR ZONE PROGRAMMING PARTITION SERIAL No. (if applicable) ZONE ZONE No. INPUT Affix Serial No. Label. No. TYPE (If applicable) TYPE from Transmitter Here No. DEVICE LOCATION 0

USE THIS WORKSHEET FOR ZONE PROGRAMMING PARTITION SERIAL No. (if applicable) ZONE ZONE No. INPUT Affix Serial No. Label. No. TYPE (If applicable) TYPE from Transmitter Here No. DEVICE LOCATION

65 Eileen Way, Syosset, New York 79 àk4240v2;ä K4240V2 9/99 Copyright 999 PITTWAY CORPORATION