StorageNet Fibre Channel Switch 4000 SES (SCSI-3 Enclosure Services) User Guide

Similar documents
IBM System Storage TS3100 Tape Library and TS3200 Tape Library. Reference. Machine Type 3573 GA

IBM System Storage TS3310 Tape Library. Reference GA

The Tape Library Experts TM RLS. SCSI Interface Reference Rev. B

Intel Storage System JBOD 2000S3 Product Family

22 March r1 FCP-4 QUERY TASK task management function

TLS-5000 TLS-6000 TLS-8000 SCSI-2 Interface Manual

Related Documents ses2r00 - SCSI Enclosure Services - 2 revision r0 - SES-2 INVOP for Threshold In page

04-218r1 SAT SPC-3 INQUIRY contents 29 July 2004

COPYRIGHT DISCLAIMER TRADEMARK NOTICES PART NUMBER REVISION HISTORY CONTACTING TANDBERG DATA CORPORATION

04-218r5 SAT SPC-3 INQUIRY contents 30 October 2004

IEEE Tutorial for SCSI use of IEEE company_id

500 disc CD-ROM Changer DRM-5004x series Changer Mechanism Controller SCSI Specifications

The next page shows the questions asked in revision 0 of this proposal and the answers supplied by the May SCSI Working Group meeting.

[1]StorageTek SL4000 Modular Library System. SCSI Reference Guide E

04-374r0 SES-2 Define a SAS Expander element 7 November 2004

[1]StorageTek Automated Cartridge System Library Software SCSI Reference Guide Release 8.5 E

T30A/T60A Tape Library SCSI I/F Specification Revision 8 19 Nov 2012

John Lohmeyer, chairperson, T10 From: Bob Snively Date: February 2, 2000 Subject:Comments on the FCP-2 letter ballot of revision 04

StorageTek T10000 Tape Drive

CONTENTS ISO/IEC:2005(E)

3 2 Parameters and states for managing asymmetrical access to SCSI logical units

Overview of operation

REMOVABLE / RE-WRITABLE MEDIA SPECIFICATION. Draft Proposal DOCUMENT STATUS. Universal Command Set for Removable/Re-Writable Media T10/97-227r0

INTERFACE SPECIFICATION GB - SCSI INCH DRIVE RELEASE 6.01

4 July r1 SAS-2 Enable and disable zoning

FCP-2 Issues To Resolve (T10/02-267r0) Dave Peterson, Cisco Systems, Inc.

Subject SMC-3 TapeAlert enhancements

04-374r2 SES-2 Define a SAS Expander element 13 January 2005

draft standard for an American National Standard for information systems - Revision 10 SCSI-3 Primary Commands 23 July 1996

Hypervisor Storage Interfaces for Storage Optimization White Paper June 2010

1.0 Editorial Changes

Revision History Related Documents Overview 1. iscsi port names and device names Suggestion 2. iscsi logical unit names Suggestion

10.2 SCSI application layer

dpans X3.xxx-199x, Rev 4.0

03-347r0 SES-2 Reporting peer enclosure service processes 15 October 2003

6 May 2008 T10/08-018r3

MAA3182SC, MAB3091SC INTELLIGENT DISK DRIVES OEM MANUAL

03-344r2 SPC-3 SAM-3 Report all initiator and target ports 30 December 2003

Plasmon M-Series M500 Optical Disk Library System. SCSI Software Interface Specification

CISS Command Interface for SCSI-3 Support Open Specification

06-378r0: SAT - Miscellaneous changes 18 August 2006

Subject Report Volume Information. This command is a companion to , Report Element Information. Full background is available in that proposal.

Related Documents r1 SCSI Management Server Commands (MSC) Project Proposal Others as needed

Revision History Revision 0 (2 November 2002) first revision Revision 1 (31 December 2002) incorporated comments from November CAP WG.

ATA Command Pass-Through

16 July r1 SAS-2 Add device slot numbering fields to DISCOVER

Information technology - Small Computer System Interface Part: 326 Reduced Block Commands (RBC), 2 nd Edition

The warranty for the library shall not apply to failures caused by: Removal of the Tandberg Data identification label(s).

ATA Command Pass-Through

SES Firmware Management Interface Specification. 4U60 Storage Enclosure G460-J-12 1ET0168 November 2015 Revision 1.1 Long Live Data

Proposal for Storage and Access of Data on Media Auxiliary Memory

04-352r0 SAS-1.1 Phy test functions for SMP 29 October 2004

2 May r2 SAS-2 WWN-based Attached Device Name for SATA

ATA Command Pass-Through

SCSI is often the best choice of bus for high-specification systems. It has many advantages over IDE, these include:

Operating System Installation Guide for Models 3xx, 5xx, 7xx, and 9xx

9 January r0 SAS-2 SPC-4 Enabling and disabling Transport Layer Retries

COMMON COMMAND SET (CCS)

DRM-7000 Service Mode Entry Procedure

September 11, T10 Technical Committee John Lohmeyer, LSI Logic Principal Member of T10 Expander Communication Protocol. Revision 3 changes:

X3T10/ revision 2 5/6/97

8 January r3 SAS-2 More counters

1 Overview. Changes to document r4. T10/ revision 0

03-344r4 SPC-3 SAM-3 Report all initiator and target ports 9 February 2004

TCG. TCG Storage Interface Interactions Specification. Specification Version 1.0. January 27, Contacts:

August 14, T10 Technical Committee John Lohmeyer, LSI Logic Principal Member of T10 Expander Communication Protocol. Revision 1 changes:

T10/06-393r1 On-disk bitmap support. Date: October 24, T10 Committee (SCSI) Roger Cummings (Symantec)

T10/03-183r1 page 1. New Inquiry VPD Page Management Network Address

T10/06-393r3 On-disk bitmap support. Date: January 16, T10 Committee (SCSI) Roger Cummings (Symantec)

Add the following section to REPORT SUPPORTED OPERATION CODES command.

04-075r0 SBC-2 Obsolete more features 27 February 2004

Proposal for Storage and Access of Data on Auxiliary Memory

Class 3 Error Detection and Recovery for Sequential Access Devices Preliminary ANSI T10 Working Document R22

Here are the updated comments as revised at the SCSI working group meeting.

03-364r1 MSC Report Bridge Mapping command 27 February 2004

14 January 2009 T10/08-018r4

T10/05-142r3 SAT - LOG SENSE command and SMART

The number in square brackets at the end of each comment description counts all the comments presented in this document.

04-082r0 SBC-2 Replace Notch and Partition mode page with READ CAPACITY 5 March 2004

Overview This proposes topics and text for an InfiniBand annex for the SCSI over RDMA (SRP) standard.

Item 2) In clause PL_OC2:Overall_Control state frame transmission cancellations: change the text to be as follows:

ADT Frame Format Notes (Paul Suhler) ADI ADT Frame Format Proposal (Rod Wideman)

TrustedFlash Security System Mapping for ATA-ACS8

Hard Drive Self-tests

Null second level LUN (0000h) (LSB) Null third level LUN (0000h) Null fourth level LUN (0000h)

These changes would become part of the peripheral device type table in the SCC standard. The new peripheral device type table would appear as follows:

Block Data is the data transferred to or from the device using SCT Command Transport feature set capabilities.

1 Overview. 2 Changes to SPC-4. T10/ revision 5

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service

17 March r1 SAM-4 SAS-2 QUERY UNIT ATTENTION task management function

Information technology - Small Computer System Interface - Part 412: SCSI Architecture Model - 2 (SAM-2)

IBM BladeCenter Chassis Management Pack for Microsoft System Center Operations Manager 2007 Release Notes

03-388r0 SBC-2 Nonvolatile caches 11 December 2003

INTERNATIONAL STANDARD

17 Distributed Switch Environment

ISO/IEC RBC 2nd Edition FCD. T10 Review Draft Only. Not an official ISO/IEC document

SMC-3 Vendor Specific Sense Code Survey

1 Overview. T10/ revision 0

4.3 The Command Descriptor Block (CDB)

Revision History Revision 0 (T10/06-225r0): Posted to the T10 web site on 4 May 2006.

Transcription:

StorageNet Fibre Channel Switch 4000 SES (SCSI-3 Enclosure Services) User Guide 8946121402

StorageNet Fibre Channel Switch 4000 SES (SCSI-3 Enclosure Services) User Guide 8946121402

Revision History Tab Level/Date The U.S. Department of Commerce restricts the distribution of technical information contained in this document when exported outside the U.S. Therefore, careful attention should be given to compliance with all applicable U.S. Export Laws if any part of this document is to be exported. 1999 Storage Technology Corporation, Louisville, Co. All rights reserved. Printed in USA. Address comments concerning this manual to: StorageTek Technical Communications 7600 Boone Avenue North Minneapolis, MN 55428-1099 USA Comments may also be submitted over the Internet by addressing them to: doccomment@network.com Description 01 (08/98) Initial release. 02 (03/99) Manual release corresponding to Release 1.6a. Always include the complete publication number and title of the document with your comments. ii 8946121402

About This Document Introduction Use this guide for monitoring, configuring, and maintaining a StorageNet Fibre Channel Switch 4000 through SCSI-3 Enclosure Services (SES). You should be knowledgeable about networking in general, routing and bridging in particular. A clearly defined network and security plan is necessary. Your security plan should assess the possible risks to your network and define access policies to deal with those risks. How This Guide is Organized This guide is divided into the following chapters: Chapter 1 Product Overview, provides an overview of SES and SES Management. Chapter 2 SES Concepts, describes the concepts associated with SES. Chapter 3 SES Commands, describes FC-PH constructs, FCP and SES commands, and diagnostics pages. Chapter 4 Troubleshooting, describes command error messages. The following appendix is also included in this guide: Appendix A Glossary. Reference Documents The following documents contain information related to SES: Fibre Channel Standards. For detailed information on the Fibre Channel standards, see the Fibre Channel Association web site at http://www.fibrechannel.com. StorageNet Fibre Channel Switch 4000 Installation and Reference Guide (8946119902) StorageNet Fibre Channel Switch 4000 WEB TOOLS User Guide (8946121602) StorageNet Fibre Channel Switch 4000 ZONING User Guide (8946121502) 8946121402 iii

Notice to the Reader The material contained in this publication is for informational purposes only and is subject to change without notice. StorageTek is not responsible for the use of any product options or features not described in this publication, and assumes no responsibility for any errors that may appear in this publication. Refer to the revision history (at the beginning of this document) to determine the revision level of this publication. StorageTek does not by publication of the descriptions and technical documentation contained herein, grant a license to make, have made, use, sell, sublicense, or lease any equipment or programs designed or constructed in accordance with this document or programs designed or constructed in accordance with this information. Customer Support For technical support, please call StorageTek at 1-800-248-8777. Before calling StorageTek, please have your information from the Problem Reporting form ready. This form is located at the back of this manual. If a problem cannot be resolved through Customer Support, a Return Material Authorization (RMA) is issued. Instructions are provided on where to return the part and how to receive a replacement part. If the product is installed by the customer, the customer is responsible for returning the product with freight paid to the nearest repair center. iv 8946121402

Table of Contents Chapter 1 Product Overview Introduction..............................................................1-1 SES Management.........................................................1-1 Chapter 2 SES Concepts Introduction..............................................................2-1 SES Functional Model......................................................2-1 Access to the Enclosure Services Process......................................2-3 Access Through an Enclosure Services Device..................................2-3 Indicators and Control Management...........................................2-3 Chapter 3 SES Commands Introduction..............................................................3-1 Constructs, Commands and Diagnostic Pages...................................3-1 FCP Constructs...........................................................3-2 FCP Command Information Unit...........................................3-2 FCP Transfer Ready Information Unit.......................................3-3 FCP Data Information Unit................................................3-3 FCP Response Information Unit...........................................3-3 FCP and SES Commands...................................................3-4 Switch Diagnostics Pages................................................3-5 Supported Diagnostics Pages..........................................3-5 Switch Page.......................................................3-6 Sensor Table Page..................................................3-7 Fabric Page........................................................3-7 Neighborhood Table Page.............................................3-8 Fibre Channel Port Table Page.........................................3-8 Name Server Local Table Page........................................3-10 Inquiry..............................................................3-11 Receive Diagnostic Results..............................................3-13 Report LUNs.........................................................3-14 Request Sense.......................................................3-14 Send Diagnostic.......................................................3-15 Test Unit Ready.......................................................3-15 Reject...............................................................3-16 8946121402 v

Chapter 4 Troubleshooting Introduction..............................................................4-1 License Reject.........................................................4-1 CHECK CONDITION....................................................4-1 Invalid Field Errors......................................................4-1 Appendix A Glossary vi 8946121402

List of Figures Figure 1-1 SES Overview...............................................1-2 Figure 2-1 SES Distribution.............................................2-1 Figure 2-2 SES Functional Model.........................................2-2 8946121402 vii

viii 8946121402

List of Tables Table 1-1 Example LUN Mapping.......................................1-2 Table 2-1 Format of LUN recognized by SESD..............................2-2 Table 2-2 LUN Mapping...............................................2-2 Table 3-1 Constructs, Commands and Diagnostic Pages.....................3-1 Table 3-2 FCP Information Unit Descriptions...............................3-2 Table 3-3 FCP_CMND IU Format.......................................3-3 Table 3-4 FCP_RSP Format............................................3-3 Table 3-5 FCP_STATUS Format.........................................3-4 Table 3-6 Supported Operation Codes....................................3-4 Table 3-7 Diagnostics Pages............................................3-5 Table 3-8 Switch MIB Groups...........................................3-5 Table 3-9 Page Code 0 Format Supported Diagnostic Pages................3-5 Table 3-10 Switch Page Format..........................................3-6 Table 3-11 Sensor Table Page Format.....................................3-7 Table 3-12 Format of Fabric Page........................................3-7 Table 3-13 Neighborhood Table Page Format................................3-8 Table 3-14 Fibre Channel Port Table Page Format...........................3-9 Table 3-15 Format of Name Server Local Table Page........................3-10 Table 3-16 Inquiry Command Format.....................................3-11 Table 3-17 Inquiry Data Format.........................................3-11 Table 3-18 Page Codes................................................3-12 Table 3-19 SESD Return Codes for 00h...................................3-12 Table 3-20 SESD Return Codes for 80h...................................3-12 Table 3-21 SESD Return Codes for 83h...................................3-13 Table 3-22 Receive Diagnostic Results Command Format.....................3-13 Table 3-23 Report LUNs Command Format................................3-14 Table 3-24 Reported LUNs Format.......................................3-14 Table 3-25 Request Sense Command Format..............................3-14 Table 3-26 Send Diagnostic Command Format.............................3-15 Table 3-27 Test Unit Ready Command Format..............................3-15 Table 3-28 Reject Command Format.....................................3-16 8946121402 ix

x 8946121402

Chapter 1 Product Overview Introduction This chapter describes StorageTek s implementation of SES (SCSI-3 Enclosure Services) on the StorageNet Fibre Channel Switch 4000. SES implementation in a SCSI-3-based Host Adapter is up to the adapter manufacturer and StorageTek cannot determine their implementation. Therefore, the focus of this guide is to discuss StorageTek s implementation of SES within the Fabric. Note: Currently, the SES standard is in DRAFT status and is subject to change. See Reference Documents for a pointer to the SES Standards Committee s web site. SES Management SES is an in-band mechanism for managing devices, such as switches, within a Fabric or other enclosures. SES commands are used to manage and sense the operational status of the power supplies, cooling devices, displays, indicators, individual drives, and other non-scsi elements installed in a switch (enclosure). The command set uses the SCSI SEND DIAGNOSTIC and RECEIVE DIAGNOSTIC RESULTS commands to obtain/set configuration information from the switch. SES allows a SCSI entity (or initiator) to communicate with a switch through a standard Fiber Channel Protocol (FCP) connection into the Fabric. The benefits are: SES does not require supporting another protocol SES does not require an additional network link (such as Ethernet) Figure 1-1 shows the Fabric SES view. The switch s Domain_ID is used as the Logical Unit Number (LUN) address to identify each switch including the switch used for access through SES. See the SES Functional Model section in Chapter 2 for more information. Note: The connection to the Fabric is through the switch labeled LUN5 and which is also called LUN0. The connection to the well known management address (FFFFFAh) is always labeled LUN0 no matter which switch is used. 8946121402 1-1

SES Management Figure 1-1 SES Overview LUN addressing within the Fabric can be non-sequential because it is based on the switch s Domain_ID. Table 1-1 shows the sample LUN mapping used with Figure 1-1. Table 1-1 Example LUN Mapping Domain ID Unique LUN Value (in Hex) 5 00000000 00000000 (Note that Domain ID 5 is used for both LUN 0 and 5) 2 01020000 00000000 5 01050000 00000000 6 01060000 00000000 9 01090000 00000000 10 010A0000 00000000 Figure 1-1 shows that the switch in the lower left hand corner is assigned both LUN5 and LUN0. (LUN5 because the switch s Domain_ID is 5 and LUN0 because the client is physically connected to that switch.) LUN values for the first byte, shown in Table 1-1, are: 00000000 00000000 - the bold characters indicate the local switch 0X0X0000 00000000 - the bold characters indicate the SCSI LUN address of the other switches in the Fabric 1-2 8946121402

SES Management Therefore, if there are 5 switches in the Fabric SES reports 6 LUNs, one LUN value for each switch and LUN0 for the local client connection. Other SCSI-3 enclosures can also run SES outside the Fabric, such as JBODs, RAID-5 arrays, SCSI-3 hard drives, and SCSI-3 tape drives. These devices are identified by their Fabric and SCSI addresses, and are assigned LUNs using standard SCSI-3 host adapter LUN addressing. Note: It is not this guide s intent to describe the environment outside of the Fabric. 8946121402 1-3

SES Management 1-4 8946121402

Chapter 2 SES Concepts Introduction This chapter uses generic terms to describe enclosure services and specific SES implementation. SES instances can be distributed inside and outside of the Fabric to any enclosure capable of supporting enclosure services through an SES device. SES is distributed transparently throughout the Fabric, with an instance of a distributed SES Device (SESD) on each switch as shown in Figure 2-1. Figure 2-1 SES Distribution SES Functional Model Each instance may be accessed by an SES Application Client by specifying the associated unique LUN. See Figure 2-2 for information on LUN addressing. SES implementation also provides an SES Application Client an in-band mechanism for managing any Fabric switch that it is attached to. Figure 2-2 shows the SES functional model. 8946121402 2-1

SES Functional Model Figure 2-2 SES Functional Model SES Application Client SES Request SES Response SES Device FCP Port FCP Command FCP Response FCP _Port FC-PH Request Sequence Response Sequence FC-PH At the Fibre Channel level, each SESD is accessible through the Fibre Channel well known address, FFFFFAh (Management Server). At the SCSI-3 level, it is associated with a LUN. An SES Application Client can refer to any distributed SESD within the Fabric using its LUN. A LUN value of 0 is always associated with the local switch that is physically attached to the SES Application Client. The unique LUN value is mapped based on peripheral device addressing. The bus number for each switch is set to 010000b as shown in Table 2-1. The first byte of the Target/LUN is set using the Domain_ID of the switch. Bytes 2..7 are set to zero. Table 2-1 Format of LUN recognized by SESD Byte/Bit 7 6 5 4 3 2 1 0 0 0 0 Bus Number = 010000b 1 Target... or 7 Logical Unit Number (LUN) Table 2-2 shows the LUN mapping. Table 2-2 LUN Mapping Domain ID Unique LUN Value (in Hex) 0 0h 01000000 00000000 5 5h 01050000 00000000 12 Ch 010C0000 00000000 15 Eh 010F0000 00000000 25 19h 01190000 00000000 2-2 8946121402

Access to the Enclosure Services Process An SES Application Client may easily find the LUN values of all distributed SESDs inside the Fabric by using the Report LUNs command. See the Report LUNs section in Chapter 3 for more information. Access to the Enclosure Services Process An application client can monitor all enclosures capable of processing the enclosure services command set with SES instances distributed throughout a Storage Area Network (SAN). Enclosure services can monitor both devices inside and outside of the enclosure, such as an Uninterruptable Power Supply (UPS). However, SES pertains only to SES instances inside the Fabric. An application client connects through Fiber Channel Protocol (FCP) using the Management Service address (FFFFAh) to any switch through its LUN. See Figure 1-1. The enclosure services command set uses the RECEIVE DIAGNOSTIC RESULTS and SEND DIAGNOSTIC commands to any device capable of supporting SES. Access Through an Enclosure Services Device The Application Client requests information from the SESD to examine status and warning information from the switch. An Application Client through FCP calls the enclosure services process running on any switch as a LUN that has SES enabled. The SESD sets the enclosure services bit (EncServ) in the INQUIRY command to indicate that it can transport enclosure services information. See the Inquiry section in Chapter 3 for more information. Indicators and Control Management SESD is accessed through an application client that uses the SEND DIAGNOSTIC command to transport control information to the enclosure services process. The control information may include operations to perform or to modify its operating mode. The application client uses the RECEIVE DIAGNOSTIC RESULTS command with the PF bit set to obtain enclosure status. The information returned indicates the actual enclosure state. See the Receive Diagnostic Results section in Chapter 3 for more information. Note: The instructions from the application client may be ignored or overwritten by the enclosure service processor to ensure proper state information. For example, the enclosure may ignore an instruction to clear an error condition because the condition is valid or because the instruction is not supported by the enclosure. 8946121402 2-3

Indicators and Control Management 2-4 8946121402

Chapter 3 SES Commands Introduction This chapter contains information and examples on managing SES, including the following: FC-PH constructs FCP and SES commands Diagnostics pages Note: SESD can be accessed from any Fabric switch licensed to run SES. Constructs, Commands and Diagnostic Pages Table 3-1 summarizes the FC-PH constructs, FCP commands, and SES commands. Table 3-1 Constructs, Commands and Diagnostic Pages Command FCP Information Unit FCP Transfer Ready Information Unit FCP Data Information Unit FCP Response Information Unit Supported Diagnostics Pages Switch Page Sensor Table Page Fabric Page Neighborhood Table Page Fibre Channel Port Table Page Name Server Local Table Page Inquiry Receive Diagnostics Results Description SCSI Command to be executed or a task management request. Contains SCSI-3 data delivery service parameters. Transfers data. Contains status and sense information. Contains the diagnostic pages supported. Contains status information about the switch, its operational state and firmware. Contains status information about the state of all sensors in the switch. Contains information about the Fabric, its neighbors and domain_id. Contains information about the switch s neighbors in the Fabric. Contains information about the switch s Fibre Channel ports. Contains information about the SESD. Contains information about the devices and sensors in an enclosure. Contains information returned by the SESD about an enclosure. 8946121402 3-1

FCP Constructs Table 3-1 Constructs, Commands and Diagnostic Pages (Continued) Command Report LUNs Request Sense Send Diagnostic Test Unit Ready Reject Description Contains information returned from SESD containing the LUNs attached to the SESD. Used to sense information from the SESD. Used to configure/diagnose a logical unit. Used to test an LUNs operation state. Contains information and status about a unit s failure. FCP Constructs Before initiating any FCP request, the Nx_Port associated with the SES Application Client (FCP Initiator) must complete an N_Port Login (PLOGI) with the Management Server in Class 2 or 3. Note: The destination address in the PLOGI request must be set to FFFFFAh. The FCP Process Login (PRLI) is not required by the SESD. The format of an FCP Command (FCP_CMND), FCP Transfer Ready (FCP_XFER_RDY), FCP Data (FCP_DATA) and FCP Response (FCP_RSP) conforms to those defined in the SCSI-3 Fibre Channel Protocol (FCP), Revision 12, X3T10/269, working draft. Table 3-2 gives a brief description of the FCP Information Unit. Table 3-2 FCP Information Unit Descriptions FCP Information Unit FCP_CMND FCP_XFER_RDY FCP_DATA FCP_RSP Description The Information Unit contains a SCSI Command to be executed or a task management request on a target. The Information Unit indicates that the target is ready to perform the data transfer associated with a FCP_CMD. The data associated with an I/O operation. The Information Unit contains status and sense information FCP Command Information Unit Table 3-3 shows the FCP_CMND Information Unit (IU) that carries either a SCSI command to be executed or a task management request to be performed. It contains the values and control fields defined in its payload. 3-2 8946121402

FCP Constructs Table 3-3 FCP_CMND IU Format Byte Size Field Name Byte Number Description 8 FCP_LUN 0-7 Logical Unit Number 4 FCP_CNTL 8-11 Control flags and bits for task/execution management 16 FCP_CDB 12-27 SCSI command descriptor block 4 FCP_DL 28-31 Data Length The FCP_LUN value format is described in Table 3-3 or the value is 0. The latter refers to the SESD on the local switch. The FCP_CNTL value is set to 1, 2 or 0 depending on whether READ DATA, WRITE DATA or neither is involved in the command. The FCP_CDB value contains the appropriate command descriptor. The FCP_DL field contains a count of the maximum number of data bytes to be transferred to or from the target for the command. FCP Transfer Ready Information Unit The FCP_XFER_RDY Information Unit contains SCSI-3 data delivery service parameters required by the initiator and must be transmitted preceding each read or write FCP_DATA IU. Note: The SESD does not generate this optional Information Unit. FCP Data Information Unit The FCP_DATA Information Unit transfers the actual data. FCP Response Information Unit Table 3-4 shows the FCP_RSP that carries the response status and sense information associated with a particular FCP_CMND. Table 3-4 FCP_RSP Format Byte Size Field Name Description 8 Reserved Reserved 4 FCP_STATUS Status of the (linked/previous) request 4 FCP_RESID Residual Count 4 FCP_SNS_LEN Length of Sense Information (FCP_SNS_INFO) 4 FCP_RSP_LEN Length of Response Information (FCP_RSP_INFO) m FCP_RSP_INFO FCP Response Information n FCP_SNS_INFO SCSI Sense Information 8946121402 3-3

FCP and SES Commands Table 3-5 shows the FCP_STATUS field format. Table 3-5 FCP_STATUS Format Byte Bit Definition 0 7.. 0 Reserved 1 7.. 0 Reserved 7.. 4 Reserved 2 3 FCP_RESID_UNDER 2 FCP_RESID_OVER 1 FCP_SNS_LEN_VALID 0 FCP_RSP_LEN_VALID 3 7.. 0 SCSI status byte from the SCSI logical unit (not used) The reserved bits are set to 0 by the SESD. FCP_RESID_UNDER indicates that the FCP_RESID field is valid and contains the number of bytes expected to be transferred, but were not transferred. See Table 3-4. This bit is not used by SESD. FCP_RESID_OVER indicates that the FCP_RESID field is valid and contains the number of bytes that have been truncated because the FCP_DL was not sufficient. See Table 3-3. This bit may be set by SESD. FCP and SES Commands Table 3-6 shows the commands supported by SESD. Table 3-6 Supported Operation Codes Command Inquiry Receive Diagnostics Results Report LUNs Request Sense Send Diagnostic Test Unit Ready Operation Code 12h 1Ch A0h 03h 1Dh 00h The value of the FCP_LUN field in FCP_CMND specifies the logical unit for the request in each command. The value of FCP_DL field in FCP_CMND specifies whether there is any data parameter to be transferred to the SESD. The value should be 0 for command 1, 2, 3, 4 and 6. For command 5, the value may be 0 or the size of a diagnostic page whose page code is in the range of 80h through 85h. 3-4 8946121402

FCP and SES Commands Switch Diagnostics Pages Before each SCSI command is discussed in detail, the diagnostics pages are defined in Table 3-7. They are particularly relevant to two commands: Receive Diagnostic Results and Send Diagnostics. The switch SESD supports 7 diagnostics pages. Table 3-7 Diagnostics Pages Page Code 00h 80h 81h 82h 83h 84h 85h Description Supported Diagnostics Pages Switch Page Sensor Table Page Fabric Page Neighborhood Table Page Fibre Channel Port Table Page Name Server Local Table Page Table 3-8 shows the page codes 80h through 85h which are vendor specific pages and are roughly mapped from the switch Management Information Base (MIB) Definition for v1.6a firmware. Table 3-8 Switch MIB Groups Page Code Switch MIB Group 80h System Group, variables 1..8, 20, 21 81h System Group, Sensor Table 82h Fabric Group, variables 1, 2 and 8 83h 84h 85h Fabric Group, Neighborhood Table Fibre Channel Port Table Name Server Local Table Supported Diagnostics Pages If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-9 Table 3-9 Page Code 0 Format Supported Diagnostic Pages Byte/Bit 7 6 5 4 3 2 1 0 0 Page Code = 00h 1 Reserved 8946121402 3-5

FCP and SES Commands Table 3-9 Page Code 0 Format Supported Diagnostic Pages (Continued) Byte/Bit 7 6 5 4 3 2 1 0 2 (MSB) 3 4 00h 5 80h 6 81h 7 82h 8 83h 9 84h 10 85h Page Length = 7 (LSB) Switch Page If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-10. Table 3-10 Switch Page Format Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 80h 1 na na Reserved 2.. 3 na na Page Length = 404 4.. 7 na na swvalid 8.. 71 0 ro Current_Date (in ASCII text) 72.. 135 1 ro Boot_Date (in ASCII text) 136.. 199 2 ro Firmware_Last_Updated_Date (in ASCII text) 200.. 263 3 ro FLASH_Last_Updated_Date (in ASCII text) 264.. 327 4 ro Boot_PROM_Last_Updated_Date (in ASCII text) 328.. 391 5 ro Firmware_Version_Information (in ASCII text) 392.. 395 6 ro Switch_Operational_Status 396.. 399 7 rw Switch_Administrative_Status 400.. 403 8 ro Diagnostics_Result 404.. 407 9 ro Number_of_Sensors Note: na is not available, ro is read only and rw is read/write 3-6 8946121402

FCP and SES Commands The field swvalid is bit mapped and indicates which subsequent fields within the page are valid. The bit position for subsequent fields starts from 0, as indicated in the Field # column of Table 3-10. For example, if the fields: Current_Date, Boot_Date and Number_of_Sensors are valid, it contains the hex value of 0003h. Sensor Table Page If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-11. Table 3-11 Sensor Table Page Format Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 81h 1 na na Reserved 2.. 3 na na Page Length = n - 3 4.. 7 na na swnumentries = i specifies the number of entries received for bytes 8-91, if the number is 5 there are 5 complete outputs for byte 8-91. 8.. 11 na ro swvalidity[0] 12.. 15 0 ro swsensorindex[0] 16.. 19 1 ro swsensortype[0] 20.. 23 2 ro swsensorstatus[0] 24.. 27 3 ro swsensorvalue[0] 28.. 91 4 ro swsensorinfo[0]..... more instances of swsensorentry (swvalidity.. swsensorinfo) if applicable... (n-64)..(n-1) 4 ro swsensorinfo[i-1] Fabric Page If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-12. Table 3-12 Format of Fabric Page Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 82h 1 na na Reserved 2.. 3 na na Page Length = 20 4.. 7 na na swvalid 8.. 11 0 ro swdomainid 8946121402 3-7

FCP and SES Commands Table 3-12 Format of Fabric Page (Continued) Byte/Bit Field # Access 7 6 5 4 3 2 1 0 12.. 15 1 ro PrincipalSwitchFlag 16.. 19 2 ro NumberOfImmediateNeighbor 20.. 23 3 ro NumberOfFabricISL_Entries Neighborhood Table Page If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-13. Table 3-13 Neighborhood Table Page Format Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 83h 1 na na Reserved 2.. 3 na na Page Length = n - 3 4.. 7 na na swnumentries = i specifies the number of entries received for bytes 8. Note that each entry consists of swvalidity[0] field through field 5. 8.. 11 na rw swvalidity[0] 12.. 15 0 ro swnbindex[0] 16.. 19 1 ro NswNbMyPort[0] 20.. 23 2 ro swnbremotedomainid[0] 24.. 27 3 ro swnbremoteport[0] 28.. 31 4 ro swnbbaudrate[0] 32.. 35 5 ro swnbislstate[0]..... more instances of swnbentry (swvalidity.. swnbislstate) if applicable... (n-4)..(n-1) 0-5 ro swnbislstate[i-1] Fibre Channel Port Table Page If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response shown in Table 3-14. 3-8 8946121402

FCP and SES Commands Table 3-14 Fibre Channel Port Table Page Format Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 84h 1 na na Reserved 2.. 3 na na Page Length = n - 3 4.. 7 na na swnumentries = i specifies the number of entries received. Note: Each entry consists of swvalidity[0] field through field 27. 8.. 11 na rw swvalidity[0] 12.. 15 0 ro swfcportindex[0] 16.. 19 1 ro swfcporttype[0] 20.. 23 2 ro swfcportphystatus[0] 24.. 27 3 ro swfcportopstatus[0] 28.. 31 4 rw swfcportadmstatus[0] 32.. 35 5 ro swfcporttxwords[0] 36.. 39 6 ro swfcportrxwords[0] 40.. 43 7 ro swfcporttxframes[0] 44.. 47 8 ro swfcportrxframes[0] 48.. 51 9 ro swfcporttxc2frames[0] 52.. 55 10 ro swfcporttxc3frames[0] 56.. 59 11 ro swfcportrxlcs[0] 60.. 63 12 ro swfcportrxmcasts[0] 64.. 67 13 ro swfcporttoomanyrdys[0] 68.. 71 14 ro swfcportnotxcredits[0] 72.. 75 15 ro swfcportrxencinfrs[0] 76.. 79 16 ro swfcportrxcrcs[0] 80.. 83 17 ro swfcportrxtruncs[0] 84.. 87 18 ro swfcportrxtoolongs[0] 88.. 91 19 ro swfcportrxbadeofs[0] 92.. 95 20 ro swfcportrxencoutfrs[0] 96.. 99 21 ro swfcportrxbados[0] 100.. 103 22 ro swfcportrxc3discards[0] 104.. 107 23 ro swfcportmcasttimedouts[0] 8946121402 3-9

FCP and SES Commands Table 3-14 Fibre Channel Port Table Page Format (Continued) Byte/Bit Field # Access 7 6 5 4 3 2 1 0 108.. 111 24 ro swfcporttxmcasts[0] 112.. 115 25 ro swfcportlipins 116.. 119 26 ro swfcportlipouts 120.. 123 27 ro swfcportliplastalpa..... more instances of swfcportentry (swvalidity.. swfcporttxmcasts) if applicable... (n-4)..(n-1) 0-27 ro swfcportliplastalpa[i-1] Name Server Local Table Page If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the following response as shown in Table 3-15. Table 3-15 Format of Name Server Local Table Page Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 85h 1 na na Reserved 2.. 3 na na Page Length = n - 3 4.. 7 na na swnumentries = i Note that each entry consists of swvalidity[0] field through field 10. 8.. 11 na ro swvalidity[0] 12.. 15 0 ro swnsindex[0] 16.. 19 1 ro swnsporttype[0] 20.. 23 2 ro swnsportid[0] 24.. 31 3 ro swnsportname[0] 32.. 287 4 ro swnsportsymbolicname[0] 288.. 295 5 ro swnsnodename[0] 296.. 551 6 ro swnsnodesymbolicname[0] 552.. 559 7 ro swnsinitialprocessinitiator[0] 560.. 575 8 ro swnsclassofservices[0] 576.. 579 9 ro swnsclassofservices[0] 580.. 643 10 ro swnsfc4types[0]...... more instances of swnslocalentry (swvalidity..swnsfc4types) if applicable... (n-4)..(n-1) 0-10 ro swnsfc4types[i-1] 3-10 8946121402

FCP and SES Commands Inquiry An SES Application Client may send an Inquiry command to obtain information about a switch in the Fabric. The format of the FCP_CDB is shown in Table 3-16. Table 3-16 Inquiry Command Format Byte/Bit 7 6 5 4 3 2 1 0 0 Operation Code = 12h 1 Reserved CmdDt=0 EVPD=0 2 Page Code = 0 3 Reserved 4 Allocation Length 5 Control = 0 If the field, EVPD (Enable Vital Product Data) is set to 0 and the value of the page code is 0, the standard Inquiry Data is returned as shown in Table 3-17. Table 3-17 Inquiry Data Format Byte/Bit 7 6 5 4 3 2 1 0 0 Peripheral Qualifier = 0 Peripheral Device Type = 0Dh 1 RMB= 0 Reserved = 0 2 ISO version = 0 ECMA version = 0 ANSI version = 3 3 AERC =0 TrmTsk= 0 NormAC A=1 Reserv ed=0 Response data format = 2 4 Additional Length = 31 (1Fh) 5 Reserved 7 Reser ved EncServ =1Bh VS = 0 MultiP =1Bh MChngr =0 ACKREQ Q=0 Addr32 =0 Addr16 =0 7 RelAdr =0 WBus32 =0 Wbus16 =0 Sync= 0 Linked= 0 Trandis= 0 CmdQu e=0 VS=0 8..15 Vendor identification = STORAGETEK 16. 31 Product identification = Switch 32. 35 Product revision level = v{n}.{m}{p (where {N} is a single number designating the major release number, {m} is a single number designating the minor release number), and {p} is a single alpha character designating a patch. There may be a space indicating there s no patch. For example, v1.5a 8946121402 3-11

FCP and SES Commands If the field, EVPD is set to 1, then the value of the page code may be set to one of the codes shown in Table 3-18. Table 3-18 Page Codes Page Code 00h 80h 83h Description Supported vital product data pages Unit Serial Number Page Device Identification Page If the page code is set to 00h, the SESD will return codes shown in Table 3-19. Table 3-19 SESD Return Codes for 00h Byte/Bit 7 6 5 4 3 2 1 0 0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh 1 Page Code = 00h 2 Reserved 3 Page length = 3 4 00h 5 80h 6 83h If the page code is set to 80h, the SESD will return codes shown in Table 3-20. Table 3-20 SESD Return Codes for 80h Byte/Bit 7 6 5 4 3 2 1 0 0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh 1 Page Code = 80h 2 Reserved 3 Page length = 24 4 Product Serial Number = the switch World_wide Name in ASCII string format E.g. 10:00:00:60:69:00:01:b4... 27 3-12 8946121402

FCP and SES Commands If the page code is set to 83h, the SESD will return codes shown in Table 3-21. Table 3-21 SESD Return Codes for 83h Byte/Bit 7 6 5 4 3 2 1 0 0 Peripheral qualifier = 0 Peripheral Device Type = 0Dh 1 Page Code = 83h 2 Reserved 3 Page length = 32 4 Reserved = 0 Code set = 2 5 Reserved = 0 Identifier type = 1 6 Reserved = 0 7 Identifier length = 28 8 Identifier = Vendor Identification (8 bytes) + Product identification (16 bytes) + Product revision level (4 bytes)... See Table 3-17. 35 Receive Diagnostic Results An SES Application Client sends a Receive Diagnostic Results command to return diagnostic or management data. The FCP_CDB format is shown in Table 3-22. Table 3-22 Receive Diagnostic Results Command Format Byte/Bit 7 6 5 4 3 2 1 0 0 Operation Code = 1Ch 1 Reserved PCV 2 Page Code 3.. 4 Allocation Length 5 Control = 0 A Page Code Valid (PCV) bit of zero indicates that the most recent Send Diagnostic command defines the data returned by this command. A value of 1 indicates that the Page Code field defines the data to be returned for this command. The page codes and formats are defined in the Switch Diagnostics Pages section. 8946121402 3-13

FCP and SES Commands Report LUNs An SES Application Client sends a Report LUNs command to obtain the number of logical units (each is a switch in SCSI impersonation) in the Fabric. The CDB format is shown in Table 3-23. Table 3-23 Report LUNs Command Format Byte/Bit 7 6 5 4 3 2 1 0 0 Operation Code = A0h 1.. 5 Reserved 6.. 9 Allocation Length 10 Reserved 11 Control = 0 The SESD reports the LUNs of associated switches with the format shown in Table 3-24. Table 3-24 Reported LUNs Format Byte/Bit 7 6 5 4 3 2 1 0 0.. 3 LUN list length (n-7) 4.. 7 Reserved 8.. 15 LUN.... (n-7)..n LUN Request Sense An SES Application Client sends a Request Sense command to obtain sense data. The CDB format is shown in Table 3-25. Table 3-25 Request Sense Command Format Byte/Bit 7 6 5 4 3 2 1 0 0 Operation Code = 03h 1.. 3 Reserved 4 Allocation length 5 Control = 0 The SESD returns a sense key of NO SENSE and an additional sense code of NO ADDITIONAL SENSE INFORMATION. 3-14 8946121402

FCP and SES Commands Send Diagnostic A SES Application Client can use a Send Diagnostic command to configure/diagnose a logical unit. After the command completion, the SES Application Client sends a Receive Diagnostic Results command. See Table 3-22. The FCP_CDB format is shown in Table 3-26. Table 3-26 Send Diagnostic Command Format Byte/Bit 7 6 5 4 3 2 1 0 0 Operation Code = 1Dh 1 Reserved PF Reserved selftest DevOfL UnitOfL 2 Reserved 3.. 4 Parameter list length 5 Control = 0 A Page Format (PF) bit of 1 specifies that the Send Diagnostic parameters conform to the page structure as specified in SCSI-3 Primary Command (SPC), Revision 11a, X3T10/995D, working draft. A value of 0 specifies that all parameters are vendor specific. At present, the SESD only supports the vendor-specific page structures as defined in the Switch Diagnostics Pages section. The selftest, DevOfL and UnitOfL bits are ignored by the SESD at present. The Parameter List Length field specifies the length in bytes of the parameter list that shall be transferred from the SES Application client to the SESD. Test Unit Ready An SES Application Client sends a Test Unit Ready command to check if the logical unit is ready. The FCP_CDB format is shown in Table 3-27. Table 3-27 Test Unit Ready Command Format Byte/Bit 7 6 5 4 3 2 1 0 0 Operation Code = 00h 1.. 4 Reserved 5 Control = 0 The SESD returns the status of GOOD and CHECK CONDITION and a sense key of NO SENSE and an additional sense code of NO ADDITIONAL SENSE INFORMATION. 8946121402 3-15

FCP and SES Commands Reject The SESD issues a Reject command to set status to Check Condition and the appropriate values for the Sense Key (SK) field. Additional Sense Code (ASC) and Additional Sense Code Qualifier (ASCQ) values are as shown in Table 3-28. Table 3-28 Reject Command Format SK ASC ASCQ Explanation 2 04h 0 Logical Unit not ready 2 35h 0 Enclosure Service failed 2 35h 2 Enclosure Service unavailable (memory allocation problem) 5 1Ah 0 Parameter List length error (too small or too big) 5 20 0 Invalid command operation code 5 20 0 Logical Unit not supported (invalid LUN value in FCP_CDB) 3-16 8946121402

Chapter 4 Troubleshooting Introduction This chapter discusses the SEND DIAGNOSTIC command error messages. License Reject A license reject is generated when the SES license key is improperly entered or is not installed. The following message is generated: Probable cause: Invalid Field Action: See the Reject section in Chapter 3 for more information. CHECK CONDITION CHECK CONIDITION is generated when the SES Device (SESD) terminates an operation because an error was encountered. These error conditions can be from invalid operations, warning indications and failure conditions. The sense key and sense code describe the error. Invalid Field Errors ILLEGAL REQUEST is generated from any invalid fields in the CDB, from parameters of a SEND DIAGNOSTIC command and from the CDB of a RECEIVE DIAGNOSTIC RESULTS command. The sense code identifies the location of the invalid fields, parameter or CDB. The following message is generated: Probable cause: Invalid Field Action: See the Reject section in Chapter 3 for more information. 8946121402 4-1

Introduction 4-2 8946121402

Appendix A Glossary Application Client: The source object of the SCSI commands and destination for the command responses. Byte: A group of 8 bits. Command Descriptor Block: The structure of up to 16 bytes in length used to communicate commands from the application client to a device server. Critical Condition: An enclosure condition where one or more elements inside the enclosure have failed or are outside of operational parameters. The element failure makes normal operation of at least some elements in the enclosure impossible, although some of the elements inside the enclosure may be able to continue normal operation. Device: A mechanical, electrical or electronic part in an enclosure. Device Server: A logical unit object that executes SCSI tasks. Device Service Request: A request from an application client of SCSI commands to a device server. Device Slot: An insertion position in an enclosure for SCSI devices. The position provides power, signal and control connections for the SCSI device. The position may also provide protection, automatic insertion, device status LEDs, locking capability, and additional features to manage SCSI devices in the enclosure. Device Type: The device type or device model implemented by the device server. Domain_ID: The domain number uniquely identifies the switch in a Fabric. Normally the switch domain ID is automatically assigned by the principal switch and may be any value between 0 and 31. This number may also be assigned manually. Enclosure: The box, rack or box set that provide power, mechanical protection, external interfaces and cooling for the SCSI device(s). Enclosure Services: The services that establishes indictors and controls for the proper operation and maintenance of devices within the enclosure. Enclosure Services Device: A SCSI device that monitors and controls enclosure services. The switches imbedded port. Initiator: A SCSI device containing application clients that originate device service requests to be processed by the device servers. 8946121402 A-1

Logical Unit: A target-resident entity that implements a device model and executes SCSI commands originated by an application client. Logical Unit Number: A device or element known by an enclosure that identifies it to the application client. Redundancy: The presence in an enclosure of one or more elements capable of automatically taking over the functions of a failed element. SCSI: Small Computer Systems Interface. SCSI Device: A device that is connected to a service delivery subsystem and supports the SCSI application protocol. Target: A SCSI device that receives SCSI commands and directs such commands to one or more logical units for execution. A-2 8946121402

Index A Application Client A-1 ASC Field 3-16 ASCQ Field 3-16 B Bit Page Code Valid 3-13 Byte A-1 C Code Additional Sense 3-16 Additional Sense Code Qualifier 3-16 Sense NO ADDITIONAL SENSE INFORMATION 3-14 Command FCP Data Information Unit 3-3 Information Unit 3-2 Response Information Unit 3-3 Transfer Ready Information Unit 3-3 Inquiry 3-11 Receive Diagnostic Results 3-13, 3-15 Reject 3-16 Report LUNs 3-14 Request Sense 3-14 Send Diagnostic Test Unit Ready 3-15 3-15 Command Descriptor Block A-1 Constructs, FC-PH 3-2 Critical Condition A-1 D Device A-1 Device Server A-1 Device Service Request A-1 Device Slot A-1 Device Type A-1 Diagnostics Pages 3-5 Domain_ID A-1 E Enclosure A-1 Enclosure Services A-1 Enclosure Services Device A-1 F FCP Command, Information Unit 3-2 FCP Data Information Unit Command 3-3 FCP Response Information Unit Command 3-3 FCP Transfer Ready Information Unit Command 3-3 FC-PH Constructs 3-2 Field ASCQ 3-16 SK 3-16 I Initiator A-1 Inquiry Command 3-11 Inquiry Data 3-11 K Key Sense 3-16 No Sense 3-14 L Logical Unit A-2 Logical Unit Number A-2 8946121402 Index-1

P Page Diagnostics 3-5 Fabric 3-7 Fibre Channel Port Table 3-8 Neighborhood Table 3-8 Sensor Table 3-7 Supported Diagnostics 3-5 Switch 3-6 Page Code Valid Bit 3-13 R Receive Diagnostic Results Command 3-13, 3-15 Redundancy A-2 Reject Command 3-16 Report LUNs Command 3-14 Request Sense Command 3-14 S SCSI A-2 SCSI Device A-2 Send Diagnostic Command 3-15 Sense Additional Code Field ASC 3-16 Additional Code Qualifier 3-16 Sense Key 3-16 SilkWorm Fabric Page 3-7 Fibre Channel Port Table Page 3-8 Neighborhood Table Page 3-8 Sensor Table Page 3-7 Switch Page 3-6 SK Field 3-16 Supported Diagnostics Pages 3-5 T Target A-2 Test Unit Ready Command 3-15 Index-2 8946121402

Comment Sheet StorageTek welcomes your comments about this publication. Please complete this form, including your name and address, and mail it to StorageTek, Technical Communications Department, 7600 Boone Avenue North, Minneapolis, Minnesota, 55428-9919, USA. Comments may also be submitted over the Internet by addressing them to: doccomment@network.com Always include the complete publication number and title of the document with your comments. Name: Company: Address: City, State: Zip Code: Publication Number and Revision: Publications Title: COMMENTS:

FOLD 1ST FOLD 1ST NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO. 19774 MPLS, MN POSTAGE WILL BE PAID BY ADDRESSEE ATTN: TECHNICAL COMMUNICATIONS DEPARTMENT STORAGETEK 7600 BOONE AVENUE NORTH MINNEAPOLIS, MN 55428-9919 FOLD FOLD CUT ON VERTICAL LINE TAPE DO NOT STAPLE TAPE

StorageTek Problem Reporting Please direct any product-related problems or complaints to the following toll-free telephone number: 1-800-248-8777 Please be aware that, depending on your maintenance and/or warranty coverage, the services delivered may be chargeable. This form is provided for your convenience in gathering information for your call. Make as many copies as you wish. Please have the following information available when reporting a problem: Site ID Customer Name Serial Number (Hardware Products only) Product being reported on (BorderGuard, RDS) Customer Contact Call back Telephone Number Problem Description (Include error messages or other supporting documentation.) Impact on Customer Operations (Is the problem an annoyance, minor interruption, or severe impact on your operations?) Please record the following information for future reference: Customer Problem Number (if assigned) StorageTek Problem Number Date Reported Time Reported Comments