Networking sensors. Distributing safety. Reducing automation cost. Product Overview AS-Interface

Similar documents
Product Overview. by Bihl+Wiedemann

CERTUS Configurable Safety Module

Certus Configurable Safety Module

Revolutionizing control wiring

MSI Safety Devices PRODUCT INFORMATION

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

FOOD AND BEVERAGE AUTOMATION & ELECTRICAL SOLUTIONS

Compact Power for Decentralized Applications MOVIPRO SDC/ADC

Balluff smart safety BE ON THE SAFE SIDE. SAFETY OVER IO-LINK

selos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail

L-force. Inverter Drives 8400 protec. On site and all systems go!

POINT I/O Family. Chapter. Overview

Trusted Strategic Partners in Process Automation. Alliance Member

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

FIeldbus. Sense it! Connect it! Bus it! Solve it! /03

Making Hazardous Operations Safe and Productive

CLIPLINE complete. The modular terminal block system for all applications

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

CIP Safety for Drives

Siemens Safety Integrated Take a safe step into the future

POINT I/O Family. Chapter. Overview

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

AUTOMOTIVE AUTOMATION & ELECTRICAL SOLUTIONS

MSI 100, MSI 200 Programmable Safety Controllers

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

POINT I/O Family. Chapter. Overview

Electrical Demand Specification (Reference SOP: )

1. Introduction. 2. Design. Safety and Emergency Stop Circuit Design Standard. Safety and Emergency Stop Circuit Design Standard.

Phone: Fax: Web: -

Compact Coded Magnetic Safety Interlock Switch and Control Units

MVK Metal Safety. Active Safety Technology. ÔMaximum Ô Safety. ÔÔRobust. ÔÔSealed

SIRIUS Monitoring and Controlling. Overview of safety relays. Safety Integrated. Answers for industry.

Safety is a SIRIUS business

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

POINT I/O Family. Chapter. Overview

NE1A/DST1. DeviceNet Safety System

SMARTSCAN INFORMATION T4 SERIES LIGHT CURTAINS HANDBOOK

Industrial Controls. Safety Integrated Application Manual. ASIsafe circuits for safety technology with AS-Interface safety monitor and DP/AS-i F-Link

1. Summary. 2. Contacts. Safety Controls Guidelines. Table of Contents

EM-F-7G Safety Extension Module

MODULAR SAFETY INTEGRATED CONTROLLER

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Pluto AS-i. Safety PLC. Approvals: Control of: Features:

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Solid-State Switching Devices

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Transponder-coded. with guard locking

Safety is a SIRIUS business

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02

for a perfect electrical installation. The range of rail-mounted terminal blocks

FieldLink process networking

POINT I/O Family. Chapter. Overview

ABB ROBOTICS PRODUCT MANAGEMENT, JUNE 2017 SafeMove2. Product Overview

CompactBlock Guard I/O Modules ArmorBlock Guard I/O Modules POINT Guard I/O Modules

Process Automation. Chemical/Petrochemical

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

6222 Two Door Module Technical Operations Manual

MSR178DP. Description. Features. Specifications

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

SUNCLIX Connection technology for photovoltaics

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

SIRIUS Motor Management and Control Devices

samos Product Range samos Modular Electronic Safety System

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

PRSU/5 Safety Interface Controller

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview

Non-Contact Safety System CES-AZ

FACTORY AUTOMATION 2009 REFERENCE & BUYER'S GUIDE AS-INTERFACE PRODUCTS

Your Global Automation Partner. Elevating Ethernet Intelligence: Implementing Ethernet Technology in Industrial Applications. White Paper - W1004

AS-Interface Safety at Work

Safety PLC. Safety Controller. Safety Relays. AS-Interface Safety at Work. Light Curtains. Safety Interlock Switches

CERTUS Configurable Safety Module

Safety in system: Protection for man and machine Installation systems for safe series connection

Product Overview Safety Engineering electronic

Quick Disconnect vs. Hard-Wiring: Selecting A Connectivity System For Your Industrial Application

Partner for automation Water technology

INSTALLATION INSTRUCTIONS

Introduction to Safety PLCs GuardLogix & CIP Safety

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Drives & Controls. IndraDrive Mi2 motor-integrated drive system. Open and flexible communication through integrated multi-ethernet interface

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Industrial Revolutions. Smart Industry / Industry 4.0

Versatile and safe. Transponder-coded safety systems CES

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

AS-Interface Safety at Work

Roof Truss Roller Press, Tables and Jigging

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

AS-i Safety Relay Output Module with Diagnostic Slave

General. Remote I/O A4/1.

Transcription:

Networking sensors. Distributing safety. Reducing automation cost. Product Overview AS-Interface

How to Use Short Links Why Use AS-Interface? Just insert #keyword in the search field on our website and press ENTER. A list of appropriate products will be displayed. AS-Interface (actuator-sensor interface) is an industrial network solution specifically designed for simplicity, flexibility, and reliability. Easy decentralized installation replaces the clutter, disorder, and the frustration that comes with traditional cabling methods. The network connects your lowest level I/O devices such as discrete I/O, sensors, analog and safety data, encoders, light curtains, and e-stops to a single network cable. It s all about simplifying the design of a control system, reducing wiring complexity, cutting installation costs, improving diagnostics, and ultimately making automation more productive. Flexible and efficient Enables use of any network topology No limitations on how to route, expand, or split network runs Easily integrated into a larger fieldbus network Adding or removing modules has never been easier without disrupting the network Supported by just about every industrial PLC manufacturer Reliable technology guaranteed Successful low-level I/O network Cost-effective, low-level networking solution Millions of AS-Interface field devices installed worldwide Supports transmitting standard and safe signals on one cable Piercing connection technology cannot be beaten in terms of simplicity and connectivity of devices Piercing needles on modules penetrate the conductors of the cable Robust and secure electrical connection Simplicity with a single cable A single, two-conductor cable connects I/O modules from any manufacturer Efficient installation method Cable design eliminates the danger of reversing polarity www.pepperl-fuchs.com 2 3

AS-Interface Infrastructure

Target Markets for AS-Interface Material Handling Industry AS-Interface products are a dependable option for the Material Handling Industry where applications demand fast and reliable networks. Automotive Industry AS-Interface products are often the techno logy of choice in the Automotive Industry where equipment must support lean, flexible manufacturing and provide speed, simplicity, and reliability in I/O networking. Process Industry AS-Interface products are frequently used in Process Industries (chemical plants, paint production, pharmaceuticals) where modules for hazardous areas are required.

Input/Output Modules for Field-Mounted Applications #G10 G10 modules not only mount easily in tight locations but also perfectly address applications where inputs and outputs are highly distributed. G10 modules have a one-piece housing that mounts in seconds. Insert the flat cable, close the top, and tighten the screw. Connect and done! G11 modules offer an innovative seal concept in a robust, compact, round design and are particularly suitable for machine builders and harsh process environments. G12 modules have a one-piece, flat housing that are extremely easy to connect and replace with no tools. #G11 #G12 #G16 G16 modules are specifically designed for installation and use where space is limited. Pepperl+Fuchs offers modules with rugged housings and high IP ratings for a wide range of field applications where cost savings, installation time, and module size are crucial. Each module uses high-quality, machined, gold-plated piercing contacts that provide superior long-term contact stability without damaging the internal strands of the AS-Interface cable. G10 ultra compact module Simple and cost-effective mounting concept Single-piece housing No loose parts, nothing to lose or assemble Mounting is possible even in confined spaces Any sensor or actuator becomes an "AS-Interface device" Ideal for heavily distributed I/O systems with up to three I/O per location G11, G12, G16 modules minimal or tool-free installation Easy to mount or replace with minimal tools needed Modules distinguish themselves by their mechanics and I/O configuration options Variety of mounting types based on application needs Multiple input/output connections with an LED to indicate the presence of a fault Diagnostic features available for output overload/short-circuit indication Analog versions of modules available 8 How to Use Short Links See page 2. More information is available at www.pepperl-fuchs.com/as-interface 9

Input/Output Modules for Field-Mounted Applications G4 modules are unique, with cabling routing from bottom of module, ensuring cleaner installations. G20 modules are effective for controlling DC motor rollers in modern, energy-efficient conveyor applications. #G4 G4 module cord grip Internal cage tension spring terminals enable you to cut the cable to the exact length Module fits directly on top of programmer without cable Mounting through holes or DIN rail G20 module intelligent DC motor control DC motor roller module version available to control all motor functions Digital pneumatic version available for simple on/off functions Modules are easily split into manageable segments preassembled, ready to be transported and tested How to Use Short Links See page 2. More information is available at www.pepperl-fuchs.com/as-interface 10 11

Input/Output Modules for Enclosure-Mounted Applications KE5 modules are simple to handle and designed with compact housing achieving up to 50% space savings. Input/output channels are LED back illuminated including channel-specific overload indications. Front push-in connector simplifies installation. #KE5 KE5 enclosure mount modules with push-in technology Front side push-in connection for easy mounting Backlit I/O identification and status-indication LEDs Transparent cover make all labels visible at all times Individually removable connectors enable simple removal of single terminals Functionally safe modules can be used for safety applications Cleaner machine design cables are hidden behind the cover AS-Interface or AUX power easily selectable KE1 enclosure mount modules for junction boxes Easy mounting by snapping onto DIN rail LEDs on front control plate display current switching state for each input Pepperl+Fuchs offers modules that fit in small control cabinets. They feature a narrow profile that uses a minimal amount of space. For easy installation, all enclosure modules have removable, mechanical, and color-coded terminals that support wire sizes up to 14 AWG for connection of the I/O. They have an IP20 protection rating and diagnostic LEDs to minimize troubleshooting and maximize runtime. #KE1 KE1 modules are ideal for compact junction boxes where height may be limited. How to Use Short Links See page 2. More information is available at www.pepperl-fuchs.com/as-interface 12 13

Gateways and Power Supplies

Gateways and Power Supplies #K30_ SAFETY Safety at Work gateways are available with gateway and safety monitor in one housing. These gateways provide connectivity to single or dual AS-Interface networks. #K20 Standard gateway characteristics include EFD (Earth Fault Detection), double address detection, and a simple diagnostics interface. Safety At Work Gateways Up to 31 safety modules per gateway Safe outputs onboard Relay and electronic PLe, SIL3, CAT4 rated Best way to get safety diagnostics to PLC VAZ-SW-SUITE software required for configuration, diagnostics, and programming Standard Gateways Single network 62 nodes Dual network 124 nodes LCD text display Integrated memory card Color-coded removable terminals Duplicate address detection Ground fault indication Noise detector Overvoltage indication Built-in coils AS-Interface Power Supplies Power supplies are integral to any AS-Interface network Every AS-Interface network segment requires a power supply AS-Interface runs at 30.5 VDC Power supplies are available from ~ 2.8 A to 8 A What power supply is right for you? The AS-Interface network checking utility helps users choose the correct power supply, ensures that voltage drop has not been exceeded, and verifies the configuration of the AS-Interface network. Pepperl+Fuchs offers gateways for all standard buses such as: EtherNet/IP, PROFINET, PROFIBUS, DeviceNet and CC-Link. Gateways control the AS-Interface system and make the process data available to all higher-level networks of the PLC in a defined configuration. #Power AS-Interface power supplies are needed to decouple the power and data transferred on the same cable. www.pepperl-fuchs.com/ sortiment/power_calc #Power_calc How to Use Short Links See page 2. More information is available at www.pepperl-fuchs.com/as-interface 16 17

Safety

Why Safety at Work? AS-Interface with Integrated Safety Pepperl+Fuchs offers AS-Interface with integrated safety. With Safety at Work, users can quickly implement a safety system that satisfies the rules and regulations needed to meet the most stringent safety requirements of PLe, SIL3, and EN ISO 13849 standard. Safety at Work can be added to any network, new or old. This is a level of backward compatibility and security that no other solution can offer and the reason why AS-Interface is "investment safe." Safe Link (Switch required) Ethernet Switch Benefits of AS-Interface Safety at Work Enables networking of safety devices (safety door switches, emergency stop pushbuttons, safety light curtains, etc.) using standard AS-Interface networks One network required to transfer safe and unsafe data Safety support up to highest performance levels Safety PLC not needed Automatic address replacement Up to 32 independent safe zones Why Safe Link? Safe data sharing over Ethernet Interconnection of multiple safe networks Most efficient and cost-effective way to link safe signals from multiple AS-Interface networks Safety relays have been used to safeguard machines and protect workers. The drawbacks of this approach are wiring complexity, the complete lack of useful diagnostics, nearly nonexistent flexibility, and ultimately, a high total cost of ownership. Configuration and Diagnostics Using the VAZ-SW-SUITE software drag-and-drop interface, the safety logic is defined by picking graphical function blocks from the device library. VAZ-SW-SUITE software offers exceptionally clear and intuitive diagnostics with the same graphical symbols used during configuration: colors indicate operational states. System maintenance is simple with the memory card and removable terminals. Simply replace the safety controller, move the memory card, and apply power. Gateway Power Supply G10 Modules Gateway Power Supply G10 Modules Address: 13 Address: 5 Address: 3 Address: 1 Address: 10 Address: 2 Network 1 Network 2 20 21

Safety Monitors KE4 Safety Monitor Can stand alone and replace safe micro PLCs Can be added to an existing AS-Interface system where safety is desirable Memory card available for easy program transfer Safe coupling allows communication between safety monitors Equally valuable when third-party AS-Interface gateway (that does not support safety) exists on the AS-Interface network VAZ-SW-SUITE software required for configuration, diagnostics, and programming KE4 safety monitors are ideal for applications where you would like to introduce safety into an existing system where there is no AS-Interface gateway. #Monitors How to Use Short Links See page 2. More information is available at www.pepperl-fuchs.com/as-interface Networked Safety with AS-Interface Safety at Work Power Supply Gateway Input/Output Modules (non-safety) Pepperl+Fuchs offers Safety Monitors for AS-Interface Safety at Work which can be used as stand-alone devices or can be combined in a safety monitor/gateway combination. Stand-alone safety monitors are a great way to achieve a low-cost, safe output on AS-Interface, because AS-Interface safety can be added to any network regardless of age or master type. Safety Input Safety Input Safety Monitor Safety Input Safety Input Safety Monitor Safety Network 1 Safety Network 2 Multiple KE4 safety monitors can monitor the same safety input module on AS-Interface. 22 23

Safety Input and Output Modules Pepperl+Fuchs offers a variety of safety input and output modules available in field- and enclosure-mounted versions. These modules are specifically designed and constructed to satisfy rules and regulations necessary to obtain desired safety ratings. This construction includes redundancy at the inputs and internal components. G12 safety modules connect dry-contact inputs for connection to standard e-stops and gate switches. KE1 safe input modules connect safe contacts in the control cabinet or junction box via removable, color-coded terminals. KE3 safe output modules connect redundant relay outputs in the control cabinet. Multiple remote safe output modules can be associated with the same safe data channel if required. KE4 rotational speed monitor monitors the standstill, rotational speed and direction of rotation on a maximum of two axes. How to Use Short Links See page 2. #SafetyIO 24 25

Safety Switches

Safety Switches Pepperl+Fuchs offers a variety of safety switches, enabling switches, and e-stops that connect directly to the AS-Interface network, providing seamless integration into standard PLCs and higher-level networks. Emergency stops can be easily connected to the AS-Interface cable with a G10 safety input module. The AS-Interface safety module is integrated into the e-stop itself. Four versions are available: illuminated panel mount, non-illuminated panel mount, illuminated field mount, and non-illuminated field mount. Safe enabling switches allow operators to enter a potentially harmful area without shutting the machine down. If the operator senses an unsafe condition, they can fully push or release the enabling switch, shutting down the machine. Safe magnetic door switches are designed for use on moveable machine guarding components. Coded magnets are needed to bypass the safety operation. With their rugged, noncontact design, these switches withstand typical mechanical abuse and vibration. Safety door interlock switches prevent machine operation in the event of a potential hazard. Switches are available with LEDs (optional) and power to lock or unlock options. Every safety switch has two internal contacts that are safely opened when the key is removed with or without solenoid locking function interruptions. How to Use Short Links See page 2. #Switches 28 29

AS-Interface Accessories Pepperl+Fuchs offers all the accessories you ll need to put your AS-Interface network together from spools of flat cable to splitters, adapters, handheld programmers, and more. Although a standard two-wire round cable can be used, the preferred way to install AS-Interface is via the famous yellow flat cable. It provides an efficient installation method and, with the mechanical keying, guarantees correct polarity. Also, the yellow cable ensures that the network operates at peak electrical performance, regardless of the network length (up to 100 meters per segment) and network topology. A variety of M8 and M12 connectors are available, bringing easy connectivity options to AS-Interface networks. Repeaters enable segments to be strung together, extending the length of an AS-Interface network. Up to two repeaters can be connected in series to achieve a maximum network expansion of 1000 m in combination with the terminators. Stack lights are available to indicate the system status, state of safety components, and warn operators when a problem occurs. With AS-Inter face, the stack light is no longer required to be wired back to the enclosure-mounted PLC. Pushbutton modules and stack lights are frequently used on AS-Interface networks. Operating buttons with a flat cable connection and integrated indicator lights are provided for manual operation. System components can be easily controlled using the START/STOP buttons, providing the operator visual feedback on their system. A handheld programmer is the easiest way to assign addresses to AS-Interface modules on the network. It can also be used as a diagnostic tool to read the module profile, set parameters, read inputs, and set outputs. A variety of G10 AS-Interface splitters are available for flat cable branching and connecting modules to AS-Interface networks. Terminators enable segments to be increased from 100 m to a maximum of 200 m. The terminator reduces reflections at the cable ends and improves communication. With integrated multiple impedance and two options for inserting the flat cable, a network length of 200 m can be achieved with all tested topologies and cable loads. #Indicators How to use Short Links See page 2. #Accessories 30 31

www.pepperl-fuchs.com Subject to modifications Pepperl+Fuchs Printed in USA Part. No. 292211 TDOCT-0661_USA 05/16