T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

Similar documents
COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

Data Broadcast Switch

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

Conitel ASYNC Adapter

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

Multi-Port Controller

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

SCADA Point-to-Point Multiplexer

SCADA Multidrop Multiplexer

XC300 VDSL Network Extender Owners Manual

Passive CCTV Hub Plus (500134) Installation Guide

Proliphix EPA-60 Installation Guide

SPL - DS TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

SRX Multidrop TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

SRX Frame Relay TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

BT-1 TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4 SECTION 4 - OPERATION...

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

USB 2.0 LR 4-Port Extender

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

CAT5-1600A Extender. EXT-CAT5-1600A. User Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

USB 2.0 LR Extender. EXT-USB2.0-LR User Manual.

iconverter 2-Module Power Chassis

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

F271XA Fiber-Optic Telephone Modem Technical Manual

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking

CAT U S E R M A N U A L

SERVICE MANUAL MODEL SSW-520-F

DVI Extra Long Range Extender

SERVICE MANUAL MODEL SSW-321-X

EXT-DVI-CAT5-4X User Manual

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

USBTHERE User Guide USB110EXT USB120EXT. USB110 EXT shown. Extending the Range of USB

Installing the Cisco 2524 and Cisco 2525 Routers

VIP-812A DUAL NETWORKED STATION PORT

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

DVI Extra Long Range Extender

TB-100 ControLynx Terminal Block

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

SERVICE MANUAL MODEL SSP-350-X

Enterprise Call Manager

Plus-X 300. Installation and Operation Manual

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

Integrated Stepper Drive & Motor

CAT5-1600A Extender. EXT-CAT5-1600A User Manual.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

ASKING FOR ASSISTANCE

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Audisey REM-PACK-8. by Intelix

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

AD-1 POWER SUPPLY. AD-1 listed AC ADAPTER. Supplies 12 Vdc to both AP-1TB and remote speaker/microphone.

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Digital Lighting Systems, Inc.

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Boca s Family of Ethernet Products

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Digital Lighting Systems, Inc.

OP8/16 Optoisolated Digital Input Board User's Manual

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Installing the Cisco AS5400XM Universal Gateway

SMD Series Integrated Stepper Driver and Motor Revision 1.3

HDKVM ELR extension for HDMI and USB Over One CAT5

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Crestron CEN-SW-POE-5 5-Port Power over Ethernet Switch Installation Guide

Enclosure TS-530 User Manual

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

USBTHERE User Guide USB100EXT. Featuring ExtremeUSB Technology

NT1B-300 Rack Installation Instructions

SERVICE MANUAL MODEL SSW-321-D

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Power Rack 58. EXT-PS5-8R User Manual.

Card Nest Universal 12 position card nest for all K-AB cards above and all other K-AB cards.

Installation Guide for Flex Tap

USB Ranger User Guide. Cat 5 USB 2.0 Extender with Remote Power. Powered by

MODEL No. SW1X8 RS422 SWITCHER

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

FDCCM1-MM-L & FDCCM1-MM-R

SI-IES-1200-LRT Hardened Gigabit PoE/PoE+ Injector User Manual PN Rev. D

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

DP-222Q Color Video Door Phone Manual

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

Transcription:

T-Monitor E-Monitor TABLE OF CONTENTS SECTION - DESCRIPTION... SECTION - SPECIFICATIONS...3 SECTION 3 - INSTALLATION... SECTION - FRONT PANEL INDICATORS...7 SECTION - INTERFACE SIGNALS AND CABLES...8 SECTION 6 - TROUBLESHOOTING... SECTION 7 - WARRANTY...3 Data Comm for Business, Inc. PO Box 639 Champaign, IL 686-639 May 7, 009 7-897-6600 www.dcbnet.com 8007

. DESCRIPTION The DCB T-Monitor and E-Monitor use -wire repeater technology to provide a monitor point for T or E lines. The T/E-Monitor uses repeater circuits on all data paths. This active repeater function is superior to simple passive monitor devices. For some T and E circuits, the double termination of passive monitor devices will attenuate the signal enough to generate data errors. The T/E- Monitor units are the solution to this attenuation problem. The units provide both electrical isolation and actively repeat the signal. The circuitry is rated to 36 db dynamic range at the T- rate of. Mbps and 3 db dynamic range at the E- rate of.08 Mbps. Solid copper AWG, two twisted pair is the preferred cable for connection between the units (we do not recommend CAT cable). Connection to the Monitor is made through RJ8 modular connectors or -wire screw down terminal blocks. Each Monitor comes standard with three screw down terminal blocks and two RJ8 connectors. If only RJ8 connections are desired extra RJ8 adapters (part number 90 to connect to telco, 907 to connect to customer equipment) can be ordered. The T/E-Monitor is transparent to the type of data sent over the T or E link. The data can be D-, ESF, PRI, G.703, G.70, etc. The DCB T-Monitors and E-Monitors are powered by a small wallmount 0 or 0VAC transformer (included). DC power options are available (see below). Features Actively monitor T and E lines Actively repeats the T and E signals RJ8 or screw down connectors Simple connection to -wire circuits Power options 0 or 0 VAC;,, 8, or VDC U high rack mountable,,, or 3 x 9 rack 0 slot rack chassis option DIN mount option Applications Monitor T/E line to extract SS7 info Monitor T/E lines for voice applications Monitor T/E lines for data analysis

. SPECIFICATIONS. General T or E monitor output Actively repeats T or E bi-polar signals Indicators Power Accessories RJ8 wiring adapters P/N 90 and 907 (included) RJ to RJ straight through cable P/N 90009 RJ to RJ crossover cable P/N 900099 Rack shelf, U for to 3 T-Monitors 0 slot, U high 9 rack mount chassis. T Output Level: 0.dBdsx, 7.0dBm, 6.3v p-p Input Sensitivity: -36dB.3 Wire Two twisted pair solid copper. T/E In and Out Connectors RJ8 modular 90 907 Pin - In Receive Transmit Pin - In Receive Transmit Pin - Out Transmit Receive Pin - Out Transmit Receive -Wire terminal block Receive - In Receive - In Transmit - Out Transmit - Out Connect the transmit pair of one Monitor to the receive pair of the other Monitor. Pairs are not polarity sensitive. Units are supplied with 3 screw down and RJ8 adapter connectors (one each 90 and 907) 3

. Physical/Electrical. x 7. x. 00 ohm T- interface, 0 ohm E interface lbs including wall transformer 0 VAC external wall transformer included Optional 0 VAC;,, 8, VDC 30 ma.6 Environmental -0 to +70 C operating temperature

3. INSTALLATION 3. Unpacking The following is included with each unit: Unit and external power supply. Two RJ8 to terminal block adapters. One provides an equipment interface the other provides a network interface. Manual Information regarding warranty, maintenance contracts and repair. 3. Location Place the unit in a clear area where you can reach the rear panel to connect the cables. The unit has an external power supply that requires a 0 VAC outlet. The total power cord length is about 6 feet. 3.3 Connections On the unit, transmit is an output, receive is an input. The Monitor pairs are output. When connecting units to each other, the transmit of one unit must be connected to the receive of the other. Pairs are not polarity sensitive. See Section for connector pinouts. Cables for connecting the units to the telco demarc and a DSU/CSU or router are available from DCB. See Section for part numbers. NOTE Cable should be Category 3, twisted pair, shielded. DO NOT use Category cable unless absolutely necessary. If Cat cable must be used, use separate bundles for the and pairs. Demarc RJ8C & T-Mon CSU or Router & & & Monitor Connections for local monitor.

Location Location Demarc RJ8C T-Ext T-Mon CSU or Router Pins & & Pins & & Monitor Connections for remote monitor. The supplied RJ8 adapters allow all of the above connections to be made using straight through wired RJ to RJ cables (patch cords). For connection to a TELCO Demarc use the adapter labeled To TELCO Net, P/N 90 (green circuit board). To make the crossover connection between two T/E-Monitors or between a T/E-Extender and a T/E-Monitor use adapter To TELCO Net, P/N 90 on one unit and P/N 907, To Cust Equip (blue circuit board) on the other. To connect to customer equipment such as a Router, DSU or PBX, use the adapter labeled To Cust Equip, P/N 907 (blue circuit board). 6

. FRONT PANEL INDICATORS. Indicators Indicator Condition Meaning Power ON Power is applied to the unit. T-MONITOR POWER DCB 7

. INTERFACE SIGNALS AND CABLES. Connector Location and Pin Reference Monitor TX RX Right Left TX RX Power TX TX RX RX Rear Panel and Connectors 3 6 7 8 RJ Positions 8

. T- Interface.. Terminal Block Signal Receive Receive Transmit Transmit In/Out IN IN OUT OUT.. RJ8 Adapter, To TELCO Net P/N 90 (Green) Pin Signal In/Out Receive IN Receive IN 3 not used Transmit OUT Transmit OUT 6 not used 7 not used 8 not used Use this adapter and a straight through cable to connect to a TELCO Demarc (Network) interface...3 RJ8 Adapter, To Cust Equip P/N 907 (Blue) Pin Signal In/Out Receive OUT Receive OUT 3 not used Transmit IN Transmit IN 6 not used 7 not used 8 not used Use this adapter and a straight through cable to connect to an Equipment (DSU, Router, PBX, etc.) interface. 9

.3 Cables.3. T-Monitor to TELCO Demarc using RJ8 adapter 90. This cable is available from DCB, P/N 90009. RJ- RJ- DEMARC RJ-8 T-Monitor Terminal Block 68B Cable ORG Pair BLU Pair.3. T-Monitor to a T-Extender or another T-Monitor using RJ8 adapter 90 on both. This cable is available from DCB, P/N 900099. RJ- RJ- Terminal Block Terminal Block NOTE If one adapter 90 and one 907 are used then this connection can be made using straight through RJ to RJ wiring. 0

.3.3 T-Monitor to a DSU/CSU, PBX or Router with RJ8 interface using RJ8 adapter 90. This cable is available from DCB, P/N 900099. RJ- RJ- Equipment RJ-8 ORG 68B Cable T-Monitor Terminal Block Pair BLU Pair.3. T-Monitor to a DSU/CSU with DA- interface RJ- DA- 9 3.3. Sources for Individually Shielded Twisted Pair Cable: Beldon # 7838A Comm Scope # 0D General Cable # 706880 Madison Cable # 03 Quabbin Wire & Cable # 9770

6. TROUBLESHOOTING 6. General Approach When troubleshooting problems, a rational plan can save you many hours of frustration. The following is a brief outline of standard troubleshooting procedures.. Gather the facts to determine the exact nature of the problem.. Draw a picture of the system showing the equipment at both ends and the in-house wiring. Use this as a reference to note your observations, test steps and test results. A picture keeps you focused and often saves duplicate effort. 3. If you change anything, change only one thing at a time. 6. Common Problems The most common problems when installing the T-Monitor are wiring problems. Wiring problems fall into two categories; incorrect cable type and improper connections. We recommend using only Category 3, two twisted pair, shielded cable. Category, e, or 6 cable should not be used. If cat. cable must be used, it is recommended that one pair be used from each of two separate cat. cables to minimize cross-talk (NEXT). When connecting T/E-Monitors be sure that outputs are connected to inputs and inputs are connected to outputs. See diagram on page and interface information in Section. 6.3 Assistance If you need assistance troubleshooting your system, contact DCB customer support at (7) 897-6600 between 8:00 am and :00 pm central time Monday through Friday.

7. WARRANTY DCB products are warranted to be free of defects in materials and workmanship for two years. Data Comm for Business, Inc. will repair or replace any equipment proven to be defective within the warranty period. All warranty work is F.O.B. Dewey, IL. This warranty is exclusive of abuse, misuse, accidental damage, acts of God or consequential damages, etc. DCB liability shall not exceed the original purchase price. All equipment returned for warranty repair must be accompanied by a Returned Material Authorization (RMA) number. To receive an RMA number, call (7) 897-6600 between the hours of 8 AM and PM central time. Equipment must be shipped prepaid to DCB and will be returned at DCB's expense. Ship returned items to: Data Comm for Business 99 County Road 000E Dewey, IL 680 ATTN: your RMA number Data Comm for Business, Inc. PO Box 639 Champaign, IL 686-639 Tel (7) 897-6600 Fax (7) 897-33 3