Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Similar documents
Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

IECEx Certificate of Conformity

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Cable End Boxes Series 8146

Technical Data. General specifications. Rated operating distance s n 3 mm

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A

IECEx Certificate of Conformity

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

ECE Cert.fic te of Con ormity

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Grounding Monitoring Device Series 8485

Terminal Boxes Series 8118

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

Minimum cross sectional area of Conductor mm²

Product manual plug, sockets and coupler 16 A.- Z0251

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

DECONTACTOR METAL 20 A/30 A/50 A/90 A

Grounding Monitoring Device Series 8485

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

IECEx Certificate of Conformity

Technical Information Promonitor NRF560

INSTALLATION TECHNOLOGY MADE EASY

30 A / 50 A / 90 A / 150 A / 250 A

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

FEATURES DESCRIPTION

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

versatile connectors for any application

For situations susceptible to interference and safety-related applications

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Safety Instructions Cerabar S PMP71, PMP75

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Inductive sensor with analog output BI15-M30-LI-EXI

exlink Mining Electrical connectors for mining

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Sensor boxes SRBG Key features

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

SolConeX Wall-Mounted Socket, 16 A

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

IECEx Certificate of Conformity

Linear Luminaire with LED Series 6412/5

Connecting cables for valves, Sub-D socket Type codes

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Linear Luminaire with LED Series 6012/5

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Exd Connectors. for Harsh and Hazardous Locations. Connection Solutions HPG01 - REPRINT UPD300614

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

SUBCON-PLUS-PROFIB...

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Ex Junction Boxes & Control Stations

Throughwiring. single-ended. twin-ended

BA414DF Fieldbus indicator Single variable

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Bayonet resistance thermometer Model TR53

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

Content. I Explosion Protected Connectors exlink I COOPER CROUSE-HINDS GMBH

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

M E M O R A N D U M I.S.

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

General Specifications

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

Material: Weight: Bearing Life: Shaft Speed: Shaft Loads: Shock: Vibration: Bump:

Tubular Light Fitting with LED Series 6036

IECEx Certificate of Conformity

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Shaft: Ø 10 mm or Ø 12 mm. Material: Weight: Bearing Life: Shaft Speed: Shaft Loads: Shock: Vibration: Bump:

SolConeX extra-low voltage flange socket

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

ATEX Certified EExd Connectors for Worldwide Applications

Position Switches Series 8070

Series Panel Mounted Control Devices

mini CLIX: Explosion protected plug-in connector

IECEx Certificate of Conformity

Supplementary Components WirelessHART products

PHOENIX CONTACT - 01/2008

Plugs & sockets. Industrial plugs and sockets - Scame I-1 4. Industrial switched sockets - Scame I-4 5. Distribution assemblies - Scame I-6

HART Density Gauge Datasheet

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Pneumatic Control/Feedback

Hazardous Location plug and receptacle

Transcription:

Connectors, Plugs & s Technical Datasheet Table of Contents Selection Guide 2 16A Range (ELCX 0251..) 3 32A Range (ELCX 0252..) 5 63A Range (ELCX 0253..) 7 125A Range (ELCX 0254..) 9 Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 1

Selection Guide Understanding pin & sleeve configurations: A clock face is used to represent the grounding contact position for all female connectors and receptacles. With the keyway at the bottom, the female grounding contact will appear at one of the twelve hour positions. To identify the system s voltage, identify the housing colour and hour location of the connector or receptacle grounding outlet. Connector Types: Connector Type Description General Arrangement Coupler Our Coupler can be used along side our plugs to safely extend the reach of of your hazardous area equipment. Available in 16A and 32A models, these can be used to build your own ATEX/IECEx compliant extension leads. Panel Mount Plug Our Panel Mount s can be mounted to our Increased Safety Enclosures, or into your own existing equipment or enclosures to produce weather-proof, ATEX and IECEx compliant connection facilities. Available in 16A to 125A models, these can be used to safely connect your portable equipment. Our Hazardous Area Plugs can be used along side our sockets to safely connect or extend the reach of of your portable hazardous area equipment. Wall Mount Our s can be mounted alongside our Increased Safety Enclosures, or at distribution points around your facility to produce weather-proof, ATEX and IECEx compliant connection facilities. Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 2

16A Range (ELCX 0251..) Connector Variants: Rated Current Connector (Female connector shown) Nominal Voltage Type Aux. Contact Order Code (ELCX 025A BCDE FGHI ) Coupler - ELCX 0251 3304 0001 110-130V Panel Mount - ELCX 0251 8304 0001 Plug - ELCX 0251 7304 0001 - ELCX 0251 4304 0001 Coupler - ELCX 0251 3306 0001 200-250V Panel Mount - ELCX 0251 8306 0001 Plug - ELCX 0251 7306 0001 - ELCX 0251 4306 0001 Coupler - ELCX 0251 3406 0001 Panel Mount - ELCX 0251 8406 0001 Plug - ELCX 0251 7406 0001 Y ELCX 0251 4406 4001 N ELCX 0251 4406 0001 16A 480-500V Coupler - ELCX 0251 3407 0001 Panel Mount - ELCX 0251 8407 0001 Plug - ELCX 0251 7407 0001 Y ELCX 0251 4407 4001 N ELCX 0251 4407 0001 Coupler - ELCX 0251 3405 0001 600-690V Panel Mount - ELCX 0251 8405 0001 Plug - ELCX 0251 7405 0001 Y ELCX 0251 4405 4001 N ELCX 0251 4405 0001 Coupler - ELCX 0251 3506 0001 200-250V Panel Mount - ELCX 0251 8506 0001 Plug - ELCX 0251 7506 0001 Y ELCX 0251 4506 4001 N ELCX 0251 4506 0001 Hazardous Area Certification: 16A Plugs, Couplers & 16A Panel Mount s Approvals: ATEX, IECEx ATEX, IECEx Ex Marking: Ex de IIC T6 (Tamb 45 C) / T5 (Tamb 55 C) Gb Ex de IIC Gb Ex td A21 T80 C (Tamb 45 C) / T95 C(Tamb 55 C) Ex td A21 IP66 Zones of use: Zones 1 & 2 Zones 1 & 2 Ambient Temperature Range: -40 C to +55 C -40 C to +55 C Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 3

Mounting Dimensions: See general arrangement diagrams on page Connector Types: Connector Type Pin Configuration D1 D2 D3 L1 L2 L3 L4 L5 L6 1P+N+E 73 4.5 8.4 74 83 66 68 53 - Panel Mount 3P+E 77 4.5 8.4 75 83 86 88 70 - (ELCX 0251 8.) 3P+N+E 84 4.5 8.4 75 83 86 88 70-1P+N+E 6 - - 223 156 142 103 86 122 3P+E 6 - - 241 176 163 123 106 147 (ELCX 0251 4.) 3P+N+E 6 - - 241 176 163 123 106 147 Cable Entry Details: Connector Type Pin Configuration Cable Entries Cable Outside Diameter 1P+N+E - 5 18.5mm Coupler 3P+E - 5 20mm (ELCX 0251 3.) 3P+N+E - 5 20mm 1P+N+E - 5 18.5mm Plug 3P+E - 5 20mm (ELCX 0251 7.) 3P+N+E - 5 20mm 1P+N+E 1 x M25 Gland 8 17mm* 3P+E 1 x M25 Gland, 1 x M25 Plug 8 17mm* (ELCX 0251 4.) 3P+N+E 1 x M25 Gland, 1 x M25 Plug 8 17mm* *Standard Cable Entry, these may be changed using options below. Accessories/Options: Connector Accessory Description Plug Protective Cap The protective cap can be installed to protect the plug pins from damage or environmental influence whilst unplugged in the field, during storage or transportation. To be used with metal cable glands, it allows easy termination of metal cable glands Brass into the GRP enclosure. Connecting Plate This is included when the option of metallic glands is selected. Wall Mount The standard cable entries may be customised with the following options: 1 x M25 Moulded Plastic Ex e Gland, 1 x M25 Moulded Plastic Plug* Alternate Cable 1 x M25 Brass Gland (non-armoured cable), 1 x M25 Moulded Plastic Plug Entries 1 x M25 Brass Gland (armoured cable), 1 x M25 Moulded Plastic Plug 2 x M25 Moulded Plastic Ex e Gland *Standard Cable Entry Configuration Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 4

32A Range (ELCX 0252..) Connector Variants: Rated Current Connector (Female connector shown) Nominal Voltage Type Aux. Contact Order Code (ELCX 025A BCDE FGHI ) Plug - ELCX 0252 7406 0001 Coupler - ELCX 0252 3406 0001 Panel Mount - ELCX 0252 8406 0001 Y ELCX 0252 4406 4001 N ELCX 0252 4406 0001 Plug - ELCX 0252 7407 0001 480-500V Coupler - ELCX 0252 3407 0001 Panel Mount - ELCX 0252 8407 0001 Y ELCX 0252 4407 4001 32A N ELCX 0252 4407 0001 Plug - ELCX 0252 7405 0001 600-690V Coupler - ELCX 0252 3405 0001 Panel Mount - ELCX 0252 8405 0001 Y ELCX 0252 4405 4001 N ELCX 0252 4405 0001 Plug - ELCX 0252 7506 0001 Coupler - ELCX 0252 3506 0001 Panel Mount - ELCX 0252 8506 0001 Y ELCX 0252 4506 4001 N ELCX 0252 4506 0001 Hazardous Area: 32A Plugs, Couplers & 32A Panel Mount s Approvals: ATEX, IECEx ATEX, IECEx Ex Marking: Ex de IIC T6 (Tamb 40 C) / T5 (Tamb 55 C) Gb Ex de IIC Gb Ex td A21 T80 C (Tamb 40 C) / T95 C(Tamb 55 C) Ex td A21 IP66 Zones of use: Zones 1 & 2 Zones 1 & 2 Ambient Temperature Range: -40 C to +55 C -40 C to +55 C Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 5

Mounting Dimensions: See general arrangement diagrams on page Connector Types: Connector Type Pin Configuration D1 D2 D3 L1 L2 L3 L4 L5 L6 Panel Mount 3P+E 96 5.5 10 90 142 86 88 69.5 - (ELCX 0252 8.) 3P+N+E 101 5.5 10 90 142 86 88 69.5-3P+E 6 - - 294 211 198 133 118 162 (ELCX 0252 4.) 3P+N+E 6 - - 294 211 198 133 118 162 Cable Entry Details: Connector Type Pin Configuration Cable Entries Cable Outside Diameter Coupler 3P+E - 10 28mm (ELCX 0252 3.) 3P+N+E - 10 28mm Plug 3P+E - 10 28mm (ELCX 0252 7.) 3P+N+E - 10 28mm 3P+E 1 x M32 Gland, 1 x M32 Plug 12 21mm (ELCX 0252 4.) 3P+N+E 1 x M32 Gland, 1 x M32 Plug 12 21mm *Standard Cable Entry, these may be changed using options below. Accessories/Options: Connector Accessory Description Plug Protective Cap The protective cap can be installed to protect the plug pins from damage or environmental influence whilst unplugged in the field, during storage or transportation. To be used with metal cable glands, it allows easy termination of metal cable glands Brass into the GRP enclosure. Connecting Plate This is included when the option of metallic glands is selected. Wall Mount The standard cable entries may be customised with the following options: 1 x M32 Moulded Plastic Ex e Gland, 1 x M32 Moulded Plastic Plug* Alternate Cable 1 x M32 Brass Gland (non-armoured cable), 1 x M32 Moulded Plastic Plug Entries 1 x M32 Brass Gland (armoured cable), 1 x M32 Moulded Plastic Plug 2 x M32 Moulded Plastic Ex e Gland *Standard Cable Entry Configuration Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 6

63A Range (ELCX 0253..) Connector Variants: Rated Current Connector (Female connector shown) Nominal Voltage Type Aux. Contact Order Code (ELCX 025A BCDE FGHI ) Plug - ELCX 0253 7406 0001 Y ELCX 0253 4406 4001 N ELCX 0253 4406 0001 63A 480-500V Plug - ELCX 0253 7407 0001 Y ELCX 0253 4407 4001 N ELCX 0253 4407 0001 600-690V Plug - ELCX 0253 7405 0001 Y ELCX 0253 4405 4001 N ELCX 0253 4405 0001 Hazardous Area: 63A Plugs & Approvals: ATEX, IECEx Ex Marking: Ex de IIC T6 (Tamb 40 C) / T5 (Tamb 55 C) Gb Ex td A21 T80 C (Tamb 40 C) / T95 C(Tamb 55 C) IP66 Zones of use: Zones 1 & 2 Ambient Temperature Range: -40 C to +55 C Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 7

Mounting Dimensions: See general arrangement diagrams on page Connector Types: Connector Type Pin Configuration D1 L1 L2 L3 L4 L5 L6 3P+E 9 472 371 352 201 181 248 (ELCX 0253 4.) 3P+N+E 9 472 371 352 201 181 248 Cable Entry Details: Connector Type Pin Configuration Cable Entries Cable Outside Diameter Plug 3P+E - 15 35mm (ELCX 0253 7.) 3P+N+E - 15 35mm 3P+E 1 x M50 Gland, 1 x M50 Plug 22 35mm (ELCX 0253 4.) 3P+N+E 1 x M50 Gland, 1 x M50 Plug 22 35mm *Standard Cable Entry, these may be changed using options below. Accessories/Options: Connector Accessory Description Plug Protective Cap The protective cap can be installed to protect the plug pins from damage or environmental influence whilst unplugged in the field, during storage or transportation. To be used with metal cable glands, it allows easy termination of metal cable glands Brass into the GRP enclosure. Connecting Plate This is included when the option of metallic glands is selected. Wall Mount The standard cable entries may be customised with the following options: 1 x M50 Moulded Plastic Ex e Gland, 1 x M50 Moulded Plastic Plug* Alternate Cable 1 x M50 Brass Gland (non-armoured cable), 1 x M50 Moulded Plastic Plug Entries 1 x M50 Brass Gland (armoured cable), 1 x M50 Moulded Plastic Plug 2 x M50 Moulded Plastic Ex e Gland *Standard Cable Entry Configuration Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 8

125A Range (ELCX 0254..) Connector Variants: Rated Current Connector (Female connector shown) Nominal Voltage Type Aux. Contact Order Code (ELCX 025A BCDE FGHI ) Plug - ELCX 0254 7406 0001 Y ELCX 0254 4406 4001 N ELCX 0254 4406 0001 125A 480-500V Plug - ELCX 0254 7407 0001 Y ELCX 0254 4407 4001 N ELCX 0254 4407 0001 600-690V Plug - ELCX 0254 7405 0001 Y ELCX 0254 4405 4001 N ELCX 0254 4405 0001 Hazardous Area: 125A Plugs & Approvals: ATEX, IECEx Ex Marking: Ex de IIC T5 Gb Ex td A21 T95 C IP66 Zones of use: Zones 1 & 2 Ambient Temperature Range: -40 C to +45 C Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 9

Mounting Dimensions: See general arrangement diagrams on page Connector Types: Connector Type Pin Configuration D1 L1 L2 L3 L4 L5 L6 (ELCX 0254 4.) 3P+E 9 537 431 411 249 228 274 Cable Entry Details: Connector Type Pin Configuration Cable Entries Cable Outside Diameter Plug (ELCX 0253 7.) 3P+E - 20 57mm (ELCX 0253 4.) 3P+E 1 x M63 Gland, 1 x M63 Plug 27 48mm *Standard Cable Entry, these may be changed using options below. Accessories/Options: Connector Accessory Description Plug Protective Cap The protective cap can be installed to protect the plug pins from damage or environmental influence whilst unplugged in the field, during storage or transportation. To be used with metal cable glands, it allows easy termination of metal cable glands Brass into the GRP enclosure. Connecting Plate This is included when the option of metallic glands is selected. Wall Mount The standard cable entries may be customised with the following options: 1 x M63 Moulded Plastic Ex e Gland, 1 x M50 Moulded Plastic Plug* Alternate Cable 1 x M63 Brass Gland (non-armoured cable), 1 x M50 Moulded Plastic Plug Entries 1 x M63 Brass Gland (armoured cable), 1 x M50 Moulded Plastic Plug 2 x M63 Moulded Plastic Ex e Gland *Standard Cable Entry Configuration Elecex Ltd, Unit 9, Almond Road, Falkirk, FK2 9FQ, UK www.elecex.com Doc No: 006-M1-A Sheet 10