DSX-1 Plug-On Board USER MANUAL. Part Number L L1-1A August L1-1 DSX-1 Plug-On Board User Manual i

Similar documents
HDLC Module. User Manual. Part Number L1

DBU INTERFACE OPTION MODULE (MULTIPORT)

Modem-16 Module. User Manual. Part Number L1

IMUX-56/64 Module. User Manual. Part Number L1

ATLAS Quad USSI Module

Configuring Cisco Integrated Data Service Unit/Channel Service Unit (DSU/CSU) Modules and WAN Interface Cards

Configuring the E1 + G.703 and T1 + DSX-1 Modules

Dual U-BR1TE Plug-In Option Card. and Dual U-BR1TE Plug-On Option Card USER MANUAL

Chapter 4 Front Panel Option Selection

DSU 5600 Data Service Unit USER MANUAL

Octal E&M Module. User Manual. Part Number L1

2FWDOý%5,î8ý0RGXOH 8VHUý0DQXDO 3DUWý1XPEHUýìëííìåç/ë L2-1A December 1999

TDU 120e. User Manual. Part Number L L2. September L2-1C

TSU 120 & 120e User Manual

TDU 120e User Manual Part Numbers L L1

What is a Hotwire Shelf Concentration Module?

ESU LT User Manual Part Number L2

Atrie WireSpan 620. User's Manual

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

Overview. Port Adapter Overview. Channelized T1/E1 Overview CHAPTER

6-Circuit ( ) and 3-Circuit ( ) 56/64xN Data Service Unit (DSU) Data Port (DP)

MT1500A T1/FT1 CSU/DSU

VIP-812A DUAL NETWORKED STATION PORT

T1 ESF CSU Reference Manual. May B

4100/ VDC Converter Installation Instructions

Dialogic TX 5000 Series SS7 Boards

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT.

Multi-Messager USB by Nel-Tech Labs, Inc. Installation & User Manual

Configuring Clear Channel T3/E3 and Channelized T3 and T1/E1 Controllers on the Cisco ASR 9000 Series Router

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

and Network Interface Modules Installation Instructions

Dialogic TX 4000 Series SS7 Boards

1558D APS CSU/DSU st Edition

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

Metroplex 6000/T1 Global T1 Access Multiplexer HIGHLIGHTS Metroplex 6000 System Overview Diverse Applications Unified System Architecture

Owner s Instruction Manual

Product Documentation on the World Wide Web

How to Contact Us. Warranty. How to Get Support. Trademark Credits

DSU IV ESP Data Service Unit with Embedded SNMP

User's Guide. Analog Expansion Board for DIGI96/8 Series and Hammerfall Serie 4/8 Channels, 24 Bit

Product Documentation on the World Wide Web

User's Guide. Analog Expansion Board for DIGI96/8 Series, Hammerfall Series and HDSP /8 Channels, 24 Bit

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

INSTRUCTION MANUAL MODE D EMPLOI MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONI BEDIENUNGSANLEITUNG GEBRUIKSAANWIJZING KDS-100 KENWOOD CORPORATION

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

USER MANUAL CAMPUS-RS FRACTIONAL INTERFACE CARD

Appendix HSSI. M500 High Speed Serial Interface Addendum

ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT.

Access System Centum Series User Manual

T-Monitor E-Monitor TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...5

NEW ERA METER. Installation & Operation Guide NE METER

Hardware Installation & Reference Manual Megaport SS Serial I/O Board Series

MODEL 7520 DSU USER S GUIDE. Document No A2-GB May 1998

fiber optic gateway control box

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

COPPER-T EXTENDER TABLE OF CONTENTS SECTION 1 - DESCRIPTION SECTION 2 - SPECIFICATIONS... SECTION 3 - INSTALLATION

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

PCI Hardware Installation

Wireless System Receiver User s Guide

Configuring the SS7 Port Adapter

IC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est

2200 Series POS System

Westell SWI3 Digital Network Interface Unit (NIU)

Intelligent Channel Bank Craft Terminal for T1 User s Guide

2 Mesa Ethernet Dock User s Manual

10 Slim Digital Photo Frame Instructional Manual

ESU LT. User Manual. Part Number L1

ACCESS SYSTEM Test System 2000 Release Notes

14 Digital Photo Frame Instructional Manual

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

USB Port Hub HO

Port PCI Quick Installation Guide

midibox 2 user manual

DCB FT-DSU/CSU Models FT-2DS and FT-4DS USER'S MANUAL

Chapter 2. Installing the Chapter 2. Contents

Cisco 4000 Series Integrated Services Router T1/E1 Voice and WAN Network Interface Modules Data Sheet

1-channel MPEG-4 Video Encoder ACD-2100T. Ver User s Manual 0-0

Perle SMI Media Converter Installation Guide

Black & White Camera Kit with Multiplexer Video Surveillance System

Intraplex T1 CrossConnect

Messager USB w/ Night Answer

Installation Instructions

Enterprise Call Manager

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

ConnectedIO LTE Router Quick Installation Guide Connected IO All Rights Reserved Worldwide

8-port 10/100Base-TX Switch (INS-806) User s Guide

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

PRODUCT DESCRIPTION SPECIFICATIONS INSTALLATION. Dialer codes PRODUCT DIAGRAM. DL2 Dialer Module Digital Alarm Communicator Transmitter. Warning!

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

_A_EN i Doc:

SCS100. Single Channel System. User Manual. HM Electronics, Inc Whiptail Loop Carlsbad, CA USA

1-Port DSU/CSU T1 WIC for the Cisco 1700, Cisco 2600, Cisco 3600, and Cisco 3700 Series Routers

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

310 SERIES LAYER 2 MANAGED NETWORK SWITCHES Quick Start Guide

Transcription:

DSX-1 Plug-On Board Part Number 1200114L1 USER MANUAL 61200.114L1-1A August 1995 61200.114L1-1 DSX-1 Plug-On Board User Manual i

901 Explorer Boulevard Huntsville, AL 35806-2807 Phone: (205) 971-8000 Fax: (205) 971-8699 1995 ADTRAN, Inc. All rights reserved. Printed in USA. ii DSX-1 Plug-On Board User Manual 61200.114L1-1

FEDERALCOMMUNICATIONSCOMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded cables must be used with this unit to ensure compliance with Class A FCC limits. WARNING Change or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. 61200.114L1-1 DSX-1 Plug-On Board User Manual iii

iv DSX-1 Plug-On Board User Manual 61200.114L1-1

Table of Contents Chapter 1. Introduction... 1 DSX-1 Plug-On Board Overview... 1 Functional Description... 1 Features... 2 Interfaces... 2 DSX-1 Plug-On Board Specifications... 3 Physical Description... 4 Chapter 2. Installation... 5 Unpack and Inspect... 5 Shipped by ADTRAN... 5 Provided by Customer... 5 Installing the Option Module... 6 Attaching the Plug-On Board to the Option Module... 6 Wiring... 7 Power-Up Initialization... 8 Operation Alarms... 8 Warranty and Customer Service... 9 Chapter 3. Operation... 11 Overview... 11 Menu Structure... 11 Menu Operation... 11 DSX-1 Plug-On Board Menu Items... 13 Port Status... 13 CRC... 13 BPV... 14 XS0... 14 FER... 14 Port Configuration (PORT CONFIG)... 14 Format... 14 Code... 14 Yellow Alarm... 14 Line Length (ft)... 14 In-band Loopback (INBAND LPBACK)... 15 Robbed Bit Signaling... 15 Port Utility (PORT UTIL)... 16 Port Test... 16 Loopback... 16 61200.114L1-1 DSX-1 Plug-On Board User Manual vi

Table of Contents TSU Features Used With DSX-1 Plug-On Board Option... 18 Factory Restore... 18 Run Self Test... 18 Appendix A. DSX-1 Plug-On Board Failure Messages... 19 Failure Messages At Power-Up... 19 DSX-1 Plug-On Board Alarm Messages... 19 Appendix B. DSX-1 Plug-On Board Menu Tree... 21 Figures Figure 1-1 DSX-1 Plug-On Board... 4 Figure 2-1 Installing Option Module... 6 Figure 3-1 TSU 100 Main Menu... 12 Figure 3-2 Port Status Display... 13 Figure 3-3 Diagram of Loopbacks... 17 Figure B-1 DSX-1 Plug-On Board Menu Tree... 21 Tables Table 2-A Pinout Connectors for Eight-Position Modular Jack Interface... 7 Table 3-A Port Configuration Parameters... 15 vi ii DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 1. Introduction Chapter 1 Introduction DSX-1 PLUG-ON BOARD OVERVIEW FUNCTIONAL DESCRIPTION The DSX-1 plug-on board is one of the plug-on options available for use with the ADTRAN TSU 100/600. The DSX-1 plug-on board provides a single DSX-1 interface that can be used to provide access to a PBX, router, or other equipment that uses a DSX-1 interface. When used with a PBX, this interface permits the combination of voice and data in a single T1 stream. The allocation of the amount of bandwidth for the DSX-1 plug-on board is selectable. When plugged onto any option card other than the drop and insert (D&I) or DSX-1 option modules, the DSX-1 plug-on board operates exactly like the DSX-1 passthru option module. The DSX-1 plug-on board can also be installed on option modules in slots 1 through 5 of the TSU 600 and used as a data port for applications not requiring robbed-bit signaling. When plugged onto a drop & insert option module, the DSX-1 plug-on board can be used as a PBX port for the drop & insert T1. In this configuration, robbed bit-signaling can be enabled or disabled from a front-panel menu option. The DSX-1 plug-on board operates as a plug-on with any TSU option module. The DSX-1 plug-on board is configured from the front panel of the TSU 100/600 or by an external personal computer (PC) program. The 61200.114L1-1 DSX-1 Plug-On Board User Manual 1

Chapter 1. Introduction FEATURES INTERFACES internal menus for its configuration are a part of the passthru and are automatically installed when the DSX-1 plug-on board is present in the unit. The DSX-1 plug-on board has the following features: Operates using 1 to 24 DS0s Executes an extensive self test Can be used as a PBX port for the drop and insert option module Displays menu options for easy configuration Functions as a data port in slots 1 through 5 of the TSU 600 When used as a DSX-1 passthru: Operates as a drop and pass-on or as a standard passon module Provides timing for the TSU 100/600 as an option The DSX-1 plug-on board interface has the following features: DSX-1 per ANSI T1.102 RJ-48C interface connector Alternate mark inversion (AMI) or binary 8 zero substitution (B8ZS) coding Extended superframe (ESF) or superframe (SF) (D4) formatting (independent of T1 facility interface) Line length up to 655 feet Line loopback (front panel/remote/inband) 2 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 1. Introduction DSX-1 PLUG-ON BOARD SPECIFICATIONS The DSX-1 plug-on board conforms to the following specifications: DSX-1 Interface Per ANSI T1.102 Line rate Capacity Line Codes Framing Options Line Length Clock Source Tests Connectors 1.544 Mbps 1 to 24 DS0s (can be user configured, contiguous or noncontiguous) AMI Bipolar return to zero (B8ZS) ESF per ANSI T1.403 and AT&T Publication TR 54016; D4 per AT&T Publication 62411-3 db dsx up to 655 feet in 110 feet steps Supports network, secondary, and CSU timing modes Power-on circuit self test Line loopback Port loopback (internal toward Mux) RJ-45C 61200.114L1-1 DSX-1 Plug-On Board User Manual 3

Chapter 1. Introduction PHYSICAL DESCRIPTION The DSX-1 plug-on board (see Figure 1-1) is a plug-on board that plugs onto the TSU 100/600 option modules. DSX-1 Mounting Screw Holes 2x32 Plug-On Connector Figure 1-1 DSX-1 Plug-On Board 4 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 2. Installation Chapter 2 Installation UNPACK AND INSPECT Shipped by ADTRAN Provided by Customer Carefully inspect the DSX-1 plug-on board for any shipping damage. If damage is suspected, file a claim immediately with the carrier and then contact ADTRAN Customer Service. If possible, keep the original shipping container for use in shipping the DSX-1 plug-on board back for repair or for verification of damage during shipment. The following items are included in the ADTRAN shipment: DSX-1 plug-on board DSX-1 Plug-On Board User Manual (to be inserted into the main TSU 100/600 User Manual) The customer must provide the following: Cable for connection to PBX or other equipment 61200.114L1-1 DSX-1 Plug-On Board User Manual 5

Chapter 2. Installation INSTALLING THE OPTION MODULE Unless the plug-in module is hot replaceable, power to the TSU 100/600 should be Off when installing the option module with the plug-on board in the TSU 100/600. Attaching the Plug-On Board to the Option Module Figure 2-1 represents the action required for proper placement of a plug-on board on the option module. 1. Hold the plug-on board above the option module. 2. Using a downward and right-to-left motion, slip the RJ-45 connector pins into the opening in the option module back panel. 3. Moving the plug-on board downward, secure the connection of the header pins at the front of the board. 4. Install the two 4-40 screws at both edges of the option module. DSX-1 Nx 56/64 Port X.1 V.35 Nx 54/64 V.35 Figure 2-1 Installing Option Module The connection of the header pins between the option module and the plug-on board must be visually verified. Severe damage of the device can result from an improper connection. 6 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 2. Installation Wiring The DSX-1 plug-on board has an RJ-48C connector as defined in Table 2-A. Table 2-A Pinout Connectors for Eight-Position Modular Jack Interface PIN NAME DESCRIPTION 1 R1 TXDATA-RING Send data towards the DTE (PBX) 2 T RXDATA-TIP Send data towards the DTE (PBX) 3 UNUSED --- 4 R RXDATA-RING Receive data from the DTE (PBX) 5 T RXDATA-TIP Receive data from the DTE (PBX) 6,7,8 UNUSED --- 61200.114L1-1 DSX-1 Plug-On Board User Manual 7

Chapter 2. Installation POWER-UP INITIALIZATION Operation Alarms No initialization input is required. Any previously configured setting for the DSX-1 plug-on board is restored automatically upon power-up. The red Alarm LED with the Module LEDs on the TSU 100/600 front panel illuminate when an alarm condition is detected. The green OK LED illuminates when no alarm conditions are detected. 8 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 2. Installation WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five years from the date of shipment, if the product does not meet its published specifications or if it fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure. Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, or further information, contact one of the numbers on the last page of this manual. 61200.114L1-1 DSX-1 Plug-On Board User Manual 9

Chapter 2. Installation 10 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 3. Operation Chapter 3 Operation OVERVIEW Menu Structure Menu Operation The DSX-1 plug-on board is controlled as part of the TSU 100/600 using the same methods as described in the user manual for the TSU 100/600. Refer to the user manual for the TSU 100/600 for descriptions of front panel indicators and buttons. When an option card, such as the option module with the DSX-1 plug-on board, is installed in the TSU 100/ 600, the unit adds the board to the list of selectable options under the Port menu items. These menu items are shaded in the limited overview of the TSU 100 menu shown in Figure 3-1. The appendix, TSU 100 Menu Tree in the TSU 100 User Manual shows a complete menu diagram. An option module must be selected from the listing in one of the Port menu options before its menus are applicable. With the cursor on one of the Port menu items, press Enter to display a list of the currently installed option modules. To activate menus for the DSX-1 plug-on board, scroll through the list to display 1.2 DSX1 DP and press Enter. 61200.114L1-1 DSX-1 Plug-On Board User Manual 11

Chapter 3. Operation Once the option module is selected, the DSX-1 plug-on board menus appear as a subset of, and operate the same as, menus for the TSU 100/600. With the cursor on one of the TSU 100/600 four Main menu choices, press Enter or a menu number to display the first two submenu items. Use the up and down Arrows to place the cursor on the desired item and press Enter to display the first two submenu choices. TSU 100 MAIN MENU 1)STATUS 2)CONFIG 3)UTIL 1)NETWORK (NI) 2)UNIT 3)MAP XCHNG 4)MAP IN USE A (B) 5)DS0 MAP A 6)DS0 MAP B 7)PORT CONFIG 1)NI PERF REPORTS 2)NI ERRORS 3)ACTIVE ALARMS 4)VIEW HISTORY 5)PORT STATUS 1)ENTER PASSCODE 2)TIME/DATE 3)FACTORY RESTORE 4)REINIT UNIT 4)TEST 1)NETWORK TESTS 2)RUN SELF TEST 3)PORT TESTS 5)UNIT ID 6)SOFTWARE REV 7)PORT UTIL 4)CANCEL TEST Figure 3-1 TSU 100 Main Menu 12 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 3. Operation DSX-1 PLUG-ON BOARD MENU ITEMS Port Status The DSX-1 plug-on board menus are accessed from and operate the same as menus for the TSU 100/600. The DSX-1 plug-on board menu items are submenu choices of the TSU 100/600 four Main menus, as shown in Figure 3-1. For information on Factory Restore and Run Self Test, see TSU Features Used with DSX-1 Plug-On Board Option in this chapter. The DSX-1 plug-on board menu items are: Port Status Port Configuration Port Utility Port Test Port Status, a submenu of TSU 100/600 Main menu item Status (STATUS), displays error information about the DSX-1 plug-on board interface. There are four information fields. See Figure 3-2. An asterisk (*) indicates an item is active. * Figure 3-2 Port Status Display CRC An asterisk is displayed under the CRC if there are CRC errors in extended superframe format (ESF) mode. If the DSX-1 plug-on board is configured for D4 Frame format, the LCD displays n/a. 61200.114L1-1 DSX-1 Plug-On Board User Manual 13

Chapter 3. Operation BPV An asterisk (*) is displayed under the BPV if the DSX-1 plug-on board is detecting bipolar violations. XS0 An asterisk (*) is displayed under the XS0 if the DSX-1 plug-on board is detecting excessive zeroes (eight consecutive zeroes in B8ZS or 16 consecutive zeroes in AMI). FER An asterisk (*) is displayed under the FER if the DSX-1 plug-on board is detecting frame bit synchronization errors. Port Configuration (PORT CONFIG) Port Configuration, a submenu of TSU 100/600 Main menu item Configuration (CONFIG), is used to configure the DSX-1 plug-on board. When Port Configuration is displayed, place the cursor on it and press Enter to activate. Scroll to display the desired configuration and activate with Enter. The unit displays the first of six submenu items. Table 3-A identifies the available selections for Port Configuration. Continue with standard operating procedures. Format Format sets the frame format for the DSX-1 plug-on board. Code Code sets the data code for the DSX-1 plug-on board. Yellow Alarm YEL Alarm enables and disables the transmitting of yellow alarms. Line Length (ft) Line Length provides selection of the proper output level for the DSX-1 plug-on board based on the length of the interface cable. 14 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 3. Operation In-band Loopback (INBAND LPBACK) In-band Loopback sets the DSX-1 plug-on board to accept or reject in-band loopup and loopdown codes (per ANSI T1.403 specification) which may be sent to the card over the DSX-1 interface. This loopback is a line loopback. Robbed Bit Signaling This menu option is available only when the DSX-1 plug-on board is plugged onto a drop & insert card and is used to enable/disable robbed-bit signaling. MENU ITEM Format Code Yellow Alarm Line Length In-band Loopback Robbed Bit Signaling Table 3-A Port Configuration Parameters PARAMETER CHOICES D4, ESF AMI, B8ZS Enable, Disable 1-110, 110-220, 220-330, 330-440, 440-550, 550-655, >655, -3 db dsx Accept, Reject ON, OFF 61200.114L1-1 DSX-1 Plug-On Board User Manual 15

Chapter 3. Operation Port Utility (PORT UTIL) Port Utility, a submenu of the TSU 100/600 Main menu item Utilities (UTIL) displays the current software information for each port installed in the unit. This information is required when requesting assistance from ADTRAN Customer Service or when updates are needed. When Port Utility is displayed, place the cursor on it and press Enter to display the first available port. Port Test Scroll to display 1.2 DSX1 DP, and press Enter to activate. The unit displays the option card name and the software version installed. The menu Port Utility contains a second option, 2)CMD MODE, for the DSX-1 plug-on board. This option is reserved for factory use only. Press Cancel to exit or select another port. Port Test, a submenu of the TSU 100/600 Main menu item Test (TEST), activates tests of the selected data ports. Selecting the DSX-1 plug-on board displays two loopback tests available for this option module. When Port Test is displayed, place the cursor on it and press Enter to display the first available port. Scroll to select 1.2 DSX1 DP and press Enter to activate. Loopback Loopback activates the loopback function on the DSX-1 plug-on board. All ports contain a local loopback (toward the DTE) and a port loopback (toward the NI) as explained in the section Function Description in the TSU 100/600 User Manual. Line Loopback On the DSX-1 plug-on board, the line loopback causes data received at the DSX-1 plug-on board to be looped back toward the DTE (PBX) achieving a local loopback. 16 DSX-1 Plug-On Board User Manual 61200.114L1-1

Chapter 3. Operation Port Loopback The port loopback is internal and loops all data mapped to the DSX-1 plug-on board back toward the network interface on the controller. The loopback, when used in conjunction with an external bit error rate tester (BERT) to drive the network interface, exercises the entire data path from the network interface (NI) controller, through the Passthru option card, and back out the network interface controller. See Figure 3-3. To deactivate the loopback, select None under the 1.2 DSX1 DP submenu. TSU 100 T1 Network Interface (NI) (Controller) DSX-1 Plug-On Board Interface DSX-1 PBX PORT LINE LOOPBACKS Also called Secondary Interface (SI) Figure 3-3 Diagram of Loopbacks 61200.114L1-1 DSX-1 Plug-On Board User Manual 17

Chapter 3. Operation TSU FEATURES USED WITH DSX-1 PLUG-ON BOARD OPTION Factory Restore Run Self Test In addition to the DSX-1 plug-on menu items, two additional menu items of the TSU 100/600 may be operated in conjunction with the DSX-1 plug-on board. These are Factory Restore and Run Self Test. Factory Restore, a submenu of the TSU 100/600 Main menu item Utilities (UTIL) restores the factory installed default setting for all DSX-1 plug-on board parameters. When Factory Restore is displayed, place the cursor on it and press Enter to restore preset factory defaults and return to the TSU 100/600 Main menu. Run Self Test, a submenu of the TSU 100/600 Main menu item Test (TEST), executes both the DSX-1 plugon board internal test and the TSU 100/600 internal test. The results of the self test are displayed in the LCD. For additional information on Self Test see the TSU 100/ 600 User Manual. When Run Self Test is displayed, place the cursor on it and press Enter to execute the test. The unit continuously changes the display in the LCD window until all test results are shown. 18 DSX-1 Plug-On Board User Manual 61200.114L1-1

Appendix A. DSX-1 Plug-On Board Failure Messages FAILURE MESSAGES AT POWER-UP Appendix A DSX-1 Plug-On Board Failure Messages The following messages indicate a probable component failure on the DSX-1 plug-on board: EPROM CS RAM ERR EPROM checksum error Static RAM error DSX-1 PLUG-ON BOARD ALARM MESSAGES The following messages indicate an alarm condition on the DSX-1 plug-on board: Red Alarm Yellow Alarm Blue Alarm Loss of Signal Not able to frame data coming from the DSX-1 plug-on board interface; sometimes referred to as out-of-frame (OOF) Remote alarm indicator (RAI) being received from the DSX-1 plug-on board interface Receiving unframed all 1s from the DSX-1 plug-on board interface, alarm indicator signal (AIS) No signal detected from the DSX-1 plug-on board interface 61200.114L1-1 DSX-1 Plug-On Board User Manual 19

Appendix A. DSX-1 Plug-On Board Failure Messages Frame Slip Indicates a Frame Slip has occurred on the DSX-1 plug-on board interface; this is present in Alarm History only 20 DSX-1 Plug-On Board User Manual 61200.114L1-1

Appendix B. DSX-1 Plug-On Board Menu Tree Appendix B DSX-1 Plug-On Board Menu Tree The menu tree for the DSX-1 plug-on board is shown in Figure B-1. 1)PORT STATUS 2)PORT CONFIG 3)PORT UTIL 1)DSX-1 ERRORS 1)SW REVISION 2)CMD MODE: 0 1)FORMAT: D4, ESF 2)CODE: AMI, B8ZS 3)YEL ALARM: ENABLE, DISABLE 4)LINE LENGTH: 1-110, 110-220 220-330, 330-440, 440-550, 550-655, >655, -3dBdsx 5)INBAND LPBACK: ACCEPT, REJECT 6)ROB BIT SIGNL: ON, OFF 4)PORT TEST 1)LOOPBACK: NONE, LINE, PORT Figure B-1 DSX-1 Plug-On Board Menu Tree 61200.114L1-1 DSX-1 Plug-On Board User Manual 21

Appendix B. DSX-1 Plug-On Board Menu Tree 22 DSX-1 Plug-On Board User Manual 61200.114L1-1

Product Support Information Presales Inquiries and Applications Support Please contact your local distributor, ADTRAN Applications Engineering, or ADTRAN Sales: Applications Engineering (800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN Technical Support and have the unit serial number available. Technical Support (800) 726-8663 Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Return Material Authorization (RMA) department to issue an RMA number. For information regarding equipment currently in house or possible fees associated with repair, contact RMA directly at the following number: RMA Department (205) 971-8722 Identify the RMA number clearly on the package (below address), and return to the following address: ADTRAN, Inc. RMA Department 901 Explorer Boulevard Huntsville, Alabama 35806-2807 RMA #

NOTICE If the DSX-1 plug-on board is used on a D&I Module (PN 1200.065L1), the D&I assembly must be Revision H or later. The DSX-1 plug-on board, when used on a DSX-1 Passthru Option Module (PN 1200.055L1) operates only in a TSU 100 with Software Revision K or later, or in a TSU 600 with Software Revision E or later. This addendum suppor PN61200.114L1-1A. ts the DSX-1 Plug-On Board User Manual, 61200.114L1-1A July 1995