Operating and Maintenance Instructions

Similar documents
4100 and 4100/R Controllers

Assembly instruction / User manual

SX90 Process Controller

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Manual Control Unit GFC 32

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Product Data Sheet. Hochiki 8 Way I/O Card. Features

MINI MCR-SL-UI-REL(-SP)

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

High Performance Tension Controller HPTC Electrical Connection Manual

Non-communicating room controllers

RT4F-48V/50A-WAC RECTIFIER

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 97~214 Vdc 150 W 93.0% 0.98 EBD-150S105DVA

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

60 Watt Medical (MWLT)

Manual Simatek Control Unit GFC 32

ACCESS 9340/9360 Meter Input/Output Module

Switched Mode Power Supply Operating manual PAP800

Output Voltage Range. Power ma ma 700 ma 176~305 Vac 155~343 Vdc 240 W 94.0% 0.98 EBD-240S105DV

SoundwebTM. Installation Guide

Universal Power Supplies

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Temperature controller Ducted systems

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Output Voltage* (nom.)(adjustable)

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

Power supply CP-C 24/5.0

INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY. UF2500 Series

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

Output Voltage Range. Max. Output Power ma ma 700 ma 176~305 Vac 43~107 Vdc 75 W 90.5% 0.98 EBD-075S105DV

MINI-PS AC/10-15DC/8

Rhino PSM Power Supplies. Operating Instructions

QUINT-PS-3x AC/24DC/10

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

Chassis Power Supplies

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Output Voltage* (nom.)(adjustable)

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

INSTALLATION MANUAL ULTRAFLEX POWER SUPPLY. UF1500 Series

Power supply CP-E 48/1.25 Primary switch mode power supply

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

AC/DC Power Supply Series APPLICATION NOTE

Operating instructions. Switching amplifier DN0210 DN / / 2015

Power supply CP-E 24/0.75 Primary switch mode power supply

02/11/2015

Non-communicating room controllers

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

FL MC 2000E (SM40) LC

Vigil 3 Amplifiers. Installation Instructions

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Power supply CP-E 24/10.0 Primary switch mode power supply

LCI User Manual mantracourt.com

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

275 Watt Medical Ultra low profile

LCI Load Cell Junction Box with Fault Monitor

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

C-Bus Ceiling Sweep Fan Controller L5501RFCP. Installation Instructions

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

MC 11 EB-2 Power supply cabinet with external bus, AC version

Resistance measuring module

RT4F-120V/20A-WAC RECTIFIER

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

RT4F-110V/25A RECTIFIER

User s Guide. ivolt. I 2 C Bus/SMBus Voltage Level Translator. For 1.5 V to 5 V Applications.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

±15 V Current-Limited Power Supply

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

C1U-W Tx Series

em4 Accessories Digital expansions

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

(877) CPCI-6U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

P216. Condenser fan speed controller. Product bulletin. Features

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

OPERATOR S MANUAL HSF 1200W/1500W POWER SUPPLY SINGLE OUTPUT POWER SUPPLIES SINGLE PHASE, POWER FACTOR CORRECTED UNIVERSAL AC INPUT, OPTIONAL METER

Typical Efficiency (2) Max. Output Power ma 176 ~ 305 Vac 260~400Vdc 420 W 94.0% 0.95 EBC-420S105DV(SV)

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

Operating instructions. Speed monitor D / / 2014

Model HM-535 Power Supply Installation and Service Instructions

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

Room Temperature Controller

Multifunctional time delay relay MFT U31S, MFT U41SE

MODEL 805 USER MANUAL

Transcription:

Part No Description Dual EC Fan Controller Issue Date Bug no Comments 1 10 July 2012 1205 Signed CE front sheet & instructions clarified 2 28 Jan 2013 1205 Instructions clarified, identify Live & SELV circuits Table of Contents Introduction... 2 Specification... 2 Connection Details (see Terminal Block Use below )... 2 Fan Compatibility... 2 Mechanical Outline... 3 Safety... 3 EMC Compliance... 3 ESD... 3 Installation... 3 Operation... 4 Fan Speed Control and LED s:... 4 Fan Monitor:... 4 Duty Sharing (Alternate Fan Run)... 5 Simultaneous Fan Run (Load Share)... 5 Single Fan operation... 5 Power-up Check... 5 Maintenance and Servicing... 5 Terminal Block Use... 5 PCB Component Location... 6 Declaration of Conformity... 7 The most recent version of this document may be downloaded at: www.ebmpapst.co.uk/instructions 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 1 of 7

Introduction Commercial Dual Fan Controller, mains powered with enclosure, controls two fans Stop/Run and Low/High speed. Speeds preset by on-board trimmers, selected by 230VAC and volt-free inputs. Optional alternate fan run with selectable duty (changeover) period, or simultaneous (Load Share) and Single Fan operation. With LED indicators and alarm output. Configurable options set by on-board DIP switches. Specification Supply Voltage V AC 207 253 VAC AC line Frequency Hz 47 63 Hz Supply Current A 0.05 Amps, plus Fan load if wired via PCB 13A max. Alarm Relay Contacts 100mA max, 60VDC max Operating Environment -30 to 60 C, IP66 Enclosure Connection Details (see Terminal Block Use below ) Mains Connector J1 Pin Function SL1 1 Switched Live 1, Low/High fan speed Select input SL2 2 Switched Live 2, Stop/Run control input (shipped with link to 230VAC Live to Run) L 3 230VAC, Live (for Stop/Run control link) L 4 230VAC, Live (Supply to Fan 1) L 5 230VAC, Live (Input) L 6 230VAC, Live (Supply to Fan 2) N 7 230VAC, Neutral (spare) N 8 230VAC, Neutral (Supply to Fan 1) N 9 230VAC, Neutral (Input) N 10 230VAC, Neutral (Supply to Fan 2) E 11 Earth (Supply to Fan 1) E 12 Earth (Input) E 13 Earth (Supply to Fan 2) E 14 Earth (spare) Control Connector J2 Pin Function 1 Alarm Relay, Contact A (Contacts Closed = No Alarm) 2 Alarm Relay, Contact B 3 Fan 1 Speed Control PWM Output 4 Fan 1 Tachometer Open Collector / Relay Input 5 Fan 1 GND / 0V 6 Fan 2 Speed Control PWM Output 7 Fan 2 Tachometer Open Collector / Relay Input 8 Fan 2 GND / 0V 9 BMS Low/High fan speed Select Input, Volt Free Contacts 10 0V for BMS input 11 Stop/Run control input, Volt Free Contacts (shipped with link to 0V to Run) 12 0V for Stop/Run input 13 Remote Low/High fan speed Select Input, Volt Free Contacts 14 0V for Remote Low/High input Note: all 0V terminals on J2 are commoned. Fan Compatibility Fan Speed control outputs compatible with EC 0-10V or Open Collector PWM speed controlled fans, 2kHz PWM, maximum of 12 EC Fans per 0-10V output. Tachometer / Relay input compatible with Open Collector tachometer or Relay Alarm fans. 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 2 of 7

Mechanical Outline Enclosure PCB LED Identification Trimmer Identification IP Rating Cable Glands 180(L) x 94(W) x 57(H), transparent lid for LED visibility, fixing centres 165 x 79mm 157mm x 71mm, Hole centres 146mm x 60mm. Height 31mm max. LED Fan1 and Fan2 Run and Alarm, indicated by PCB silk screen legend LED En Run Enable and LED B High Speed, indicated by PCB silk screen legend Trimmer indicated by PCB silk screen legend, R1, R2 and R3 IP66 Enclosure Not included. Enclosure has knock-outs to suit 16mm or 20mm glands. Safety Installation must be by qualified personnel in accordance with local applicable standards. This equipment must be Earthed. Access is limited to service personnel only. Residual risk of contact with fan. Maintenance personnel should take due care and attention. Complies with Low Voltage Directive 37/23/EEC as amended by 93/68/EEC Complies with EN60335-1 - Specification for safety of household and similar electrical appliances Connector J1 Terminals SL1 and SL2 may be live even with the controller supply disconnected EC Fans use Capacitors to store mains voltage. Contact with the mains wiring must be avoided for 5 minutes following supply disconnection. EMC Compliance BS EN61000-6-3:2007 (emissions), BS EN61000-6-2:2005 (immunity) Radiated Emissions BS EN55022:2006, Class B, Radiated Immunity EN61000-4-3:2002 +A1+A2 Fast Transient Bursts EN61000-4-4:2004, Conducted Immunity EN61000-4-6:2007 ESD Many modern electronic components are susceptible to damage from Electro Static Discharge (Static Electricity). During commissioning, avoid unnecessary contact with electronic components on PCB s. PCB s which are Static Sensitive should be stored in anti-static packaging until installed. Installation General: See Safety information above. For connections, see Connection Details table above. Route control wiring separately from AC mains wiring. Remove enclosure knock-outs as required to fit cable glands, taking care not to damage the PCB. Cable entry at enclosure end is recommended. Tools: A 2.5mm flat screwdriver is recommended for the screw terminal block clamps and Variable Resistor adjustment. A voltmeter is required during commissioning. 230VAC Supply: Controller connection to 230VAC supply must be fused to 13A maximum. The supply for single phase fans up to 13A total load may be connected via this control PCB, connect Fans to 230VAC output and Earth output terminals. For higher currents or 3-phase fans route supply direct to fans. Fans: Connect fan supply, speed control and tachometer leads, see table above for connections. If fan has a 10V output wire cut back & insulate. If fans are Alarm Relay type (not Tachometer), connect fan relay between 0V and tachometer Input. If fan monitoring is not required, then link tachometer Input to 0V to prevent alarms. Select Inputs: Connect Run/Stop and Speed/Set-point select inputs as required for the application, see Tables below. PCB Switches and Variable Resistors: Set DIP Switches and Variable Resistors as required, see tables and procedures below. 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 3 of 7

DIP Switch Position OFF ON 1 Alternate Fan Run Simultaneous Fan Run 2, 3 Alternate Fan Run Changeover Period, see table 4 No High-Speed Start Delay High-Speed Start Delay, Three minutes 5 Two Fans Single Fan 6 RESERVED, MUST BE [Off] 7 Fan 1 Speed Control, Open Collector Fan 1 Speed Control, 0-10V 8 Fan 2 Speed Control, Open Collector Fan 2 Speed Control, 0-10V DIP Switch Alternate Fan Run Changeover Period 2 3 (Hours) Off Off 3 ON Off 6 Off ON 12 ON ON 24 Potentiometers RV1 Fan Low Speed, 20% to 100% RV2 Fan High Speed, 20% to 100% RV3 High Speed Run-on period, 0-50 minutes Operation Fan Speed Control and LED s: 1) Stop/Run: Fans will not run unless both Run enable signals (Switched Live and Volt Free) are present. LED En will be illuminated if Fan Run is enabled, and will flash mostly off if not. Unit is shipped with both Run enables linked. En LED Off indicates either no 230VAC supply or a PCB fault. 2) High Speed: Fans will run at High speed if any High Speed signal (Switched Live or Volt Free) is active, LED B illuminated. If the High potentiometer set speed is lower than the Low potentiometer set speed the fan will continue at the Low set speed. 3) High Speed Delay Start: Enabled by DIP Switch. Fan Speed Outputs will remain at Low speed after the High Speed Input becomes active, for this timer period. (exception - BMS input responds immediately) If High Speed Delay timer is running LED B will flash, mostly Off. 4) High Speed Run-on: Fan Speed Outputs will remain at High speed after the High Speed input ceases to be active, for a period set by R3. (exception - BMS input responds immediately) If Run-on timer is running LED B will flash, mostly On. Fan Monitor: 1) FAN1 and FAN2 LEDS, Green LED = Fan Running, Red LED = Fan Alarm 2) Alarm Relay output: Contacts closed = No Alarm, Contacts Open = Fan Alarm or Power Fail. 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 4 of 7

Duty Sharing (Alternate Fan Run) The controller will run each fan alternately. Each fan will run for a period selected by the DIP Switch setting, see table. In the event of a fan alarm (detected by controller monitoring the Fan Relay / Tachometer signal) the controller will: 1) Automatically switch over to the alternate fan 2) Indicate the Fan Alarm by means of the Fan red LED and Alarm Relay Note: at the end of each Duty Share period the controller will select the alternate fan. If the alternate fan is faulty the controller will swap back. Simultaneous Fan Run (Load Share) In this mode, for settings above the equivalent of two fans on minimum speed, both fans will run and the load will be shared. For speed settings below this the fans will run alternately to allow the maximum airflow range. In the event of a Fan Alarm the remaining fan speed will be doubled (up to full speed) to compensate, or for low speed setting the alternate fan will run. Single Fan operation For single fan operation connect the fan to Fan 1 controller terminals. Set the DIP switch for Single Fan operation to suppress alarms from the unfitted fan. Power-up Check At power-up all LED s will illuminate and Alarm Relay energise for a few seconds. If only one fan is running the controller will run Fan 1 briefly to check it is operating correctly, then switch to Fan 2 to check that fan. Fan run check inhibited if Enable not active. Maintenance and Servicing The PCB has no replaceable parts, if a fault develops return the PCB to the manufacturer. Terminal Block Use The terminal blocks fitted are operated as follows: Insert a 2.5mm or 3mm flat blade screwdriver fully into the upper hole as shown, to open the terminal wire entry. Insert the wire into the lower hole, then remove the screwdriver to leave the wire clamped in the terminal. Check wire clamp has moved clear to allow wire entry Alternatively, open the wire entry by inserting the screwdriver fully from the opposite side of the connector as shown Insert the wire into the lower hole, then remove the screwdriver to leave the wire clamped in the terminal. 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 5 of 7

PCB Component Location Key PCB components are identified below J1 Pin1 High Speed Run Enabled S1 LED B LED En Live Circuit SELV Circuit R1 R3 Fan1 Run Fan2 Run R2 LED LED Fan1 Alarm Fan2 Aalrm J2 Pin1 LED LED 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 6 of 7

Declaration of Conformity 04/03/2013 08:49:54 210-OMI12492_Iss2.doc ORIGINAL INSTRUCTIONS Page 7 of 7