Table of Contents & Introduction 2 Product features & Function. 3. Calibration RS232C Serial communication...6 Specifications

Similar documents
Thanks for buying our product. Specialty of IM-2DT

Table of Contents & Introduction 2 Product features & composition. 3 Functions Specifications

Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.

Features. IDS : Inclinometer Display System with RS232 Output

Hello Angles... A First Use Guide to the VS Product Series: RS232 Interface with LD Standard Communication Protocol & Analogue 4-20mA Output Signals.

User Manual. Borescope. Model THE STANDARD IN PRECISION MEASUREMENT

Model BS-150. Instruction Manual. Video Inspection Camera. reedinstruments. www. com

ISF-1DF SERIES DIGITAL FORCE GAGE OPERATION MANUAL

NannyCam V24. Instructions 1 For Use

FG-7000L Digital Force Gauge Operation Manual

Model BS-150. Instruction Manual. Video Inspection Camera. reedinstruments www.

PointWrite User Manual

-Direct.com FG-3000 Digital Force Gauge Operation Manual

R300. Quick Start Guide 15G06A E3403

from P.R.Engineering Ltd Tel:

FG-7000 Digital Force Gauge Operation Manual

Digi-Pas Innovation & Technology Driven

SHIMPO INSTRUMENTS. ST-320BL LED Stroboscope Array Operation Manual

Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah)

ROGUE Device Quick Reference Guide

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

Digi-Pas Innovation & Technology Driven

FG-3000 Digital Force Gauge Operation Manual

Alignment Software for Linear Guides

Parallel Roll Alignment Software

Digi-Pas Innovation & Technology Driven

GSCOUT GPS MODEL: GSCOUT GPS IN-CAR CAMERA USER MANUAL

f200 English User Manual Contents

Auto-leveling Rotating Laser (RL430G)

Flymote C2. Introduction. IR Learning, Air Mouse, QWERTY Keyboard Combo. User Manual

Operation Manual Defender Car vision 5018FullHD Car DVR

SLIMLINE DASH CAM Audio & Video Recorder

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

CDR-RH Room CO 2, Temperature and Humidity Sensors (Controllers)

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

MINI CLOCK TRAVEL PORTABLE FCC CE. SKU: MiniClockTravel USER MANUAL THANK YOU FOR PURCHASING THE MINI CLOCK TRAVEL

User Manual Video Borescope Model


SPECIFICATIONS. Item No.:DMI800. Description:High Accuracy Dual-axis Digital Display Inclinometer. Version:Ver.06

FG-3000R Digital Force Gauge Operation Manual

Car Video Recorder RoadRunner 560 / RoadRunner 560GPS User Manual Version 1.0

LED Innovative Lights

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

COLOR TFT LCD MONITOR. User Manual

User Manual. (Multi-language LED Digit board)

USER MANUAL.

SCOPE COMMUNICATIONS UK LTD

DashCam HD DVR Operating Manual Step by Step Set-Up Guide DashCam DVR sketch and operating key

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

User Guide. HAWKEYE CLASSIC VIDEO BORESCOPES (Non-Articulating) Hawkeye Classic Video Borescope. Hawkeye Classic Video Borescope - Set Up

DIGITAL HEIGHT GAUGE OPERATION AND MAINTENANCE MANUAL

Instruction Manual. 24" and 48" Electronic Digital Level Model Nos &

User Manual. ipad 360 Keyboard Case. For more support, please us at Your questions will be answered promptly.

Andonstar ADSM302 Digital Microscope USER MANUAL

Trend-1 Vibration Data Logger. User Manual

Inclinometer. 4-20mA and RS232

S500 Series. Operation manual for GSM temperature humidity data logger

Digital Torque Gauge. User s Manual

montana 600 series quick start manual for use with models 600, 650, 650t Montana 600 Series Quick Start Manual 1

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers

Instruction Manual. 24" and 48" Waterproof Electronic Digital Level Model Nos &

USER MANUAL

* 1080P, and can also can shoot 3 mega pixel still pictures. It uses a Micro SD card as a storage device (up to 32G), compact,

IOS I-PHONE Version. I-PHONE is a registered trademark of Apple Corp.

Marshall Electronics

Medimaging Integrated Solution Inc.

GD_MD_GJ C C SERIES. High Performance Thermographic IR Camera

In-Car DVR KPT-700 User Manual

Contents Features :... 3 Performance and Specifications:... 4 Button Functions...5 Video settings:...5 Photo settings:... 6 System Setup settings:...6

3-Axis Stabilized Handheld Gimbal

CLOVER 10 Handheld Video Magnifier User Guide. Rev G

Multi-functional Portable HD LCD Monitor. User Manual

Leica DISTO D2 Laser Distance Meter

ARX 308 User Reference Manual

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

YHC-308 & YHC-618 YHC-309M & YHC-619M

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

Basic Specifications INSPIRON. System Model Dell Inspiron 1545

Portable MEMS Inclinometer

Unit Test Calibration Training. (QL420+ & RW420) Mobile Printers

Introduction. This unit has a wide input range (6-34V) and it can provide a tightly regulated output ranging from 6 to 24V (default set to 12V).

5.6 Color Rear View Safety System Installation & Operation. RV56 (Includes MO56 monitor & CA56 camera)

DX4085 Z-Meter Tester

Vividia HM-250 HDMI/LCD/USB/TV Portable. Digital Measurement Microscope

FEC-240G. Rev. Date

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

Contents: Introduction Page Hardware...Page Connecting Inputs and Outputs..Page Software.Page 6

Equine Dental Scope VET /2017-E

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

DMI600 - Dual-Axis Digital Display Inclinometer

User Manual XPIN Clip

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Marshall M-CT710. Camera-Top Monitor. Owner s Manual

Digital thermo-hygro-barometer with external probe Manual for use

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

Transcription:

High Precision 2-Axis Digital Electronic Inclinometer IM-2DW User s Guide The contents of this manual could be different according to the software version and it can be changed without notice. Please use this good after reading the manual thoroughly.

Table of Contents Table of Contents & Introduction 2 Product features & Function. 3 Setup. 4 Calibration. 5 RS232C Serial communication....6 Specifications.7 Introduction Thanks for buying our product. IM-2DW is a high precision dual axis inclinometer with LCD display. It is different from analogue method. It indicates digital method of numerical value and direction of dual axis angle. It is possible to do high speed horizontal plane setting for high precision machines or home appliance as like laundry machine. Specialty of IM-2DW 1. Easy to set the level of the space with 2 axis angles display at once. 2. Small & light so that possible to use to a sensor unit. 3. Possible to insert to high precision systems. 4. Included the RS232C output. 5. Built-in Li-ion rechargeable battery. (Rechargeable to USB port on PC)

Product features and function Unit change ( mm/m ) Power on/off & Menu & Zero LCD backlight on/off Unit change button: 1. To change the measurement unit. ( mm/m) 2. To move up the cursor or increase the value in the setup menu. Power on/off button : 1. To turn on the power or off the power. - Power on: Pushing the button once if the power is off then the power is on with a sound. - Power off: Pushing the button for around 2 sec when the power is on. Then the power is off. 2. To enter the setup menu. - Pushing the button for around 2 sec when the power is off. Then the setup menu is displayed. 3. To change the absolute value and relative value. - Abs. value Rel. value : After pushing the button, ABS mark is disappeared on the LCD and set the current angle to zero in 5 seconds. - Rel. value Abs. value : If push the button, ABS mark is appeared on the LCD and the absolute X/Y angle values are displayed. 4. To select item on the cursor in setup menu. Backlight on/off button: 1. To turn on/off the backlight of the LCD. 2. To move down the cursor or decrease the value in the setup menu. Charge & RS232C port

Setup Turn on the power in condition of push the Power on/off button for around 2 sec. then the setup menu is come up. Using (Up) key and (Down) key, you can move the cursor, or increase/decrease of the setting values. Locate the cursor at item you re going to change, and push the key in the middle. Then you can enter the item. You must choose the Save item to save the changes you ve done.

Calibration * To calibrate the absolute zero. Please follow the steps carefully. If not, it can not be guaranteed the angle data. Step 1 [XY Calibration] 1. Choose the Calibrate item on the menu. 2. Move the cursor to the Set-XY 3. Put the inclinometer on the surface as like Fig.1 and wait until the values are settled. 4. Push the button in the middle. Then you might see Please rotate 180 and Push button again on the screen. 5. Turn around the inclinometer 180 and push the same button again if the values are settled. 6. Finished the XY calibration. Fig.1 Fig.2 Step 2 [X Calibration] 1. Choose the Calibrate item on the menu. 2. Move the cursor to the Set-X 3. Put the inclinometer on the surface as like Fig.3 and wait until the values are settled. 4. Push the button in the middle. Then you might see Please rotate 180 and Push button again on the screen. 5. Turn around the inclinometer 180 and push the same button again if the values are settled. 6. Finished the X calibration. Fig.3 Fig.4 * [Y Calibration] User doesn t have to do the Y calibration because the Y calibration is done automatically if the X calibration is done.

RS232C serial communication * ISC-T : It is necessary to do RS232C serial communication with IM-2DW / IM-2DT. Communication protocol(ascii)

Specifications System Model IM-2DW Measuring range ± 30 Resolution 0.01 Accuracy ±0.03 Non linearity < 1% FS Response time < 1.0 sec Input / Output port Charging / RS232C Mini type 5 pin USB connector Power & Other features Power Li-ion Battery 3.7V (Rechargeable) Operation time Around 7 hours with fully charged battery. * Charging LCD Size(W/L./H) Weight 5 pin mini type USB cable to PC or USB connector type adapters. 128 x 64 pixel, Black & White LCD. 115 x 66 x 23mm 180g Operation environment Temp. : 0 C ~ +45 C / Humidity : below 80% * Tip to save the battery power: 1. Reduce the brightness of the LCD. 2. Reduce the backlight turn on time if it s not uncomfortable. 3. Reduce the power on time if it s not uncomfortable. Dimensions 115mm 98mm 65.5mm 24mm 50.5mm M6 mounting threads

High Precision 2-Axis Digital Electronic Inclinometer