MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

Similar documents
MANOMETER OPERATION MANUAL. 200 mbar, differential input. Model : PM-9102

VACUUM METER Model : VC-9200

PRESSURE METER OPERATION MANUAL. Model : PS-9302

Humidity + Temp. + Dew Point Pocket size HUMIDITY METER. Model : HT-315

INSTRUCTION MANUAL FOR TQ-8800 TORQUE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

40.00/400.0/4,000/40,000/400,000 Lux LIGHT METER

DIGITAL ANEMOMETER Model : AM-4203

AC/DC MAGNETIC METER OPERATION MANUAL. Model : MG G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

AC/DC MAGNETIC METER OPERATION MANUAL. Model : PCE-MFM G ( Gauss), mt ( milli Tesla ), USB/RS232. Your purchase of this

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS General Specifications Electrical Specifications...3

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M

UV LIGHT METER UVC-254

Heavy Duty Differential Pressure Manometer. Model User's Guide

VIBRATION METER Model : VB-8213

User's Guide. Heavy Duty Differential Pressure Manometer. Model

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

CONDUCTIVITY METER OPERATION MANUAL. Model : CD-4322

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

MOISTURE METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. 3, Hagavish st. Israel Tel: , Fax:

AC/DC MAGNETIC METER

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

Torque Meter. Instruction Manual

HOT WIRE ANEMOMETER. Model : 204HA

TORQUE METER Model : TQ-8800

12 channels TEMPERATURE RECORDER Model : BTM-4208SD

OPERATION MANUAL. SD card real time Data Recorder SOLAR POWER METER. Model : SPM-1116SD

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

600 g x 0.02 g DIGITAL BALANCE

LIGHT METER OPERATION MANUAL. auto range 0 to 50,000 Lux, 3 ranges. Model : LX-113S

VB Model. Instruction Manual. Vibration Meter. reedinstruments. www. com

LED LIGHT METER OPERATION MANUAL. Model : LX-1148SD. SD card real time Data Recorder 10 Light Source select, Auto range 0 to 50,000 LUX

OPERATION MANUAL. UVA and UVB measurement UV LIGHT METER. Model : YK-35UV

SD Card real time data recorder + type K/J TEMP. CUP ANEMOMETER

Vacuum Meter Instruction Manual

SOIL MOISTURE METER OPERATION MANUAL. Model : DSMM500. Your purchase of this

OPERATION MANUAL. SD card real time datalogger HUMIDITY/TEMP. MONITOR. Model : MHT-381SD

Wide Range Pressure Meter Instruction Manual

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

Light Meter with Bar Graph

LIGHT METER OPERATION MANUAL. Model : LM-81LX

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

VANE ANEMOMETER HUMIDITY/TEMP.

TORQUE WRENCH OPERATION MANUAL. Model : TQ Kgf-cm, heavy duty, professional

Laser, PHOTO TACHOMETER RS

TU-2016 TURBIDITY METER

OPERATION MANUAL. SD card real time datalogger 3 Channels TEMPERATURE DATA RECORDER. Model : MTM-380SD. Your purchase of this 3

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

one probe, SD card real time data recorder CO2, %RH, Temp., Dew point, Wet bulb CO2 METER + HUMIDITY/Temp. Model : CO2-9914SD

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

4 in 1 Anemometer, Humidity Light Meter, Thermometer

UVA LIGHT METER OPERATION MANUAL. Model : UVA-365SD. SD card real time datalogger + Type K/J thermometer

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

OPERATION MANUAL. ph/mv SD card real time data logger ph METER. Model : PH-230SD

MOISTURE METER OPERATION MANUAL. all in one. Model : PMS-713

MMD7003 USER S MANUAL. DIGITAL and LED PRECISION MOISTURE METER

Torque Meter. Instruction Manual

DATALOGGER. SD card, real time OPERATION MANUAL. Model : DL-9602SD

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

LIGHT METER. Model : LM-81LX. Digital Measurement Metrology, Inc Digital Measurement Metrology, Inc

SD card real time data logger TDS ( Total dissolved solids ), Salt '20 us/200 us/2 ms/20 ms/200 ms CONDUCTIVITY METER.

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

OPERATION MANUAL. SD card real time datalogger HEAT INDEX WBGT METER. Model : WBGT-2010SD

Model LM-81LX. Instruction Manual. Light Meter. reedinstruments. REED Instruments

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

Anemometer, Hygrometer Light Meter, Thermometer

OPERATION MANUAL. SD card real time data logger DISSOLVED OXYGEN METER. Model : DO-5512SD

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

User's Guide. Heavy Duty Conductivity / Temperature. Model Introduction

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

TA 888 Hot Wire Anemometer

SD Model. Instruction Manual. Humidity/Temperature Datalogger. reedinstruments

SD card real time datalogger, RS232/USB Frequency weighting and Time weighting meet IEC class 2, Personal sound exposure meet IEC 61252

INSTRUCTION MANUAL. Models: H100 Light Meter

Therma-Stor LLC Model LM in-1 Pocket Thermo-Anemometer, Hygrometer, Thermometer & Illuminometer. Instruction Manual.

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Manual Digital Thermometer PCE-T 390

User's Guide. Hot Wire Thermo-Anemometer. Model

Pen type, with separate electrode PH METER Model : PH-220 OPERATION MANUAL

SD Model. Instruction Manual. Heat Stress Meter and Datalogger. reedinstruments

Datalogging Hot Wire CFM Anemometer

Clamp meter with Data recorder SERIES set

Pocket type SOUND LEVEL METER Model : SL-4030

Datalogging Conductivity/ TDS Meter. Instruction Manual

The Specification of Hot Wire Anemometer Manual PCE-423

Heavy Duty Hot Wire CFM Thermo-Anemometer

PM930SD USER S MANUAL

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

350 SMART MANOMETER OPERATING INSTRUCTIONS

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

Transcription:

7000 mbar, differential input MANOMETER Model : PM-9107 Your purchase of this MANOMETER marks a step forward for you into the field of precision measurement. Although this MANOMETER is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are developed. Please read the following instructions carefully and always keep this manual within easy reach. OPERATION MANUAL

TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications... 1 2-2 Electrical Specifications... 3 3. FRONT PANEL DESCRIPTION... 4 3-1 Display... 4 3-2 Power Off/On Button... 4 3-3 Hold Button... 4 3-4 Zero Button... 4 3-5 " MAX./MIN. " Button...4 3-6 Unit Button... 4 3-7 P1 input socket... 4 3-8 P2 input socket... 4 3-9 RS-232 Output Terminal... 4 3-10 Battery Compartment/Cover... 4 3-11 PLug/quick coupler... 4 4. MEASURING PROCEDURE... 5 5. AUTO POWER OFF DISABLE...6 6. RS232 PC SERIAL INTERFACE... 7 7. BATTERY REPLACEMENT... 8

1. FEATURES * Dual & differential input, 7000 mbar ( 7 bar ) max. range. * Application : Industrial, laboratory, heating, ventilation, medical hospital, used for air or not corrosive and not ionized gas & liquid. * Sensor is built inside the housing. * Single lugs for pipe connection. * 8 kind display units ( mbar, psi, Kg/cm 2 mm Hg, inch Hg, meter HF2, inch HF2, Atmosphere ) select by push button on the front panel * Auto shut off saves battery life. * Zero button on the front panel, easy to offset the zero value. * Microprocessor circuit assures maximum possible accuracy, provides special functions and features, * Super large LCD display with contrast adjustment for best viewing angle. * Records maximum & minimum readings with recall. * Data Hold function for stored the desired value on display. * Built-in low battery indicator. * RS232 PC serial interface, can match the personal computer used as the Data Logger, Recorder... & other modern pressure measuring system. 2. SPECIFICATIONS 2-1 General Specifications Circuit Microprocessor LSI circuit. Display 61 mm x 34 mm supper large LCD display. 15 mm ( 0.6" ) digit size. 1

Display units mbar, psi, Kg/cm 2 mm Hg, inch Hg, meter HF2, inch HF2, Atmosphere. Function Dual & differential input, data hold, zero/relative, memory. Zero adjust Push button on the front panel. Sensor * Sensor is built inside the housing. * Piezoelectric sensor. * Used for dry, non-corrosive and non-ionic air and gas only. Liquid is prohibited. Data hold By push button. Data record Record maximum & minimum readings. Data output RS 232 PC serial interface. Sampling time Approx. 0.8 second. Power off Auto shut off, saves battery life or manual off by push button. Operating 0 to 50 蚓 ( 32 to 122 蚌 ). temperature Operating Less than 80% R.H. humidity Power supply 006P DC 9V battery ( heavy duty ). Power current Approx. DC 6.0 ma. Weight 345 g/0.76 LB. Dimension 180 x 72 x 32 mm ( 7.1 x 2.8 x 1.3 inch ). Accessories * Instruction manual... 1 PC. included * Hard carrying case... 1 PC. * PLug for quick coupler... 2 PCs. Optional * Data acquisition software accessories ( Windows version )...SW-U101-WIN * RS232 cable... UPCB-01 2

2-2 Electrical Specifications Unit Max. range Resolution mbar 7000 mbar 5 mbar psi 101.5 psi 0.05/0.1 psi * Kg/cm 2 7.135 Kg/cm 2 0.005 Kg/cm 2 mm Hg 5250 mm Hg 5 mm Hg inch Hg 206.7 inch Hg 0.1 inch Hg meter HF2 71.35 meter HF2 0.05 meter HF2 inch HF2 2810 inch HF2 2 inch HF2 Atmosphere 6.905 Atmosphere 0.005 Atmosphere * psi resolution : Less than 100 psi is 0.05 psi, others is 0.1 psi. Unit Max. range Accuracy mbar 7000 mbar 2 % F. S. psi 101.5 psi Kg/cm 2 7.135 Kg/cm 2 Note : mm Hg 5250 mm Hg * 23 5 蚓. inch Hg 206.7 inch Hg * F.S. : full scale meter HF2 71.35 meter HF2 * Included linearity, inch HF2 2810 inch HF2 hysteresis and Atmosphere 6.905 Atmosphere repeatability Remark : Measuring unit Display unit mbar m Bar psi Psi Kg/cm 2 Kg /cm 2 mm Hg mm /Hg inch Hg in/hg meter HF2 m HF2 inch HF2 inch HF2 Atmosphere ATP 3

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-7 P1 input socket 3-2 Power Off/On Button 3-8 P2 input socket 3-3 Hold Button 3-9 RS-232 Output 3-4 Zero Button Terminal 3-5 " MAX./MIN. " Button 3-10 Battery Compartment 3-6 Unit Button /Cover 3-11 PLug/ quick coupler 4

4. MEASURING PROCEDURE 1) Power on the meter by pressing the " Power Off/On Button " ( 3-2, Fig. 1 ). 2) Select the desired temperature units ( mbar, psi, Kg/cm 2 mm Hg, inch Hg, meter HF2, inch HF2, Atmosphere ) by pushing the " Unit Button " ( 3-6, Fig. 1 ). 3) Zero adjusting Adjust the display reading to zero value by pushing the " Zero Button " ( 3-4, Fig. 1 ) 4) Install the measuring pipe to " Plug/quick coupler " ( 3-11, Fig. 1 ). 5) The meter is build the two input socket ( P1 input socket, P2 input socket) for accepting the differential pressure input. Connecting the pipe along the " Plug " ( 3-11, Fig. 1) to a. " P1 input socket " ( 3-7, Fig. 1 ) only b. " P2 input socket " ( 3-8, Fig. 1 ) only c. Both P1 & P2 input socket The LCD will show the measuring pressure value. Note : * If the P1 pressure > P2 pressure, the display will get positive reading. * If the P1 pressure < P2 pressure, the display will get negative reading. 6) Data Hold * During the measurement, pressing the " Hold Button " ( 3-3, Fig. 1 ) will freeze the measured value & the LCD will show " HOLD " symbol. * Press the " Hold Button " again to cancel the data hold function. 5

7) Data Record ( Maximum, Minimum reading ) * The DATA RECORD function displays the maximum and minimum readings. To start the DATA RECORD function, press the " MAX./MIN. Button " ( 3-5, Fig. 1 ) once. " REC " symbol will appear on the LCD display. * With the " REC " symbol on the display : (a) Press the " MAX./MIN. Button " ( 3-5, Fig. 1 ) once, the " Max " symbol along with the maximum value will appear on the display. (b) Press the " MAX./MIN. Button " again, the " Min " symbol along with the minimum value will appear on the display. (c) To exit the memory record function, press the " MAX./MIN. Button " continuously for at least 2 seconds. The display will revert to the current reading. 8) For quick measurement, follow the procedures shown below : Main procedures : POWER ON ZERO ADJUST DETERMINE UNIT Optional measuring procedures : DATA HOLD MEMORY RECORD RS232 OUTPUT Max., Min. Power management AUTO POWER OFF or MANUAL POWER OFF (Not activated during Memory Record Selection) 6

5. AUTO POWER OFF DISABLE The instrument has built-in " Auto Power Shut-off " in order to prolong battery life. The meter will switch off automatically if none of the buttons are pressed within 10 min. To de-activate this feature, Select the memory record function during measurement, by pressing the " MAX./MIN. Button " ( 3-5, Fig. 1 ). 6. RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3.5 mm Terminal ( 3-9, Fig. 1 ). The connector output is a 16 digit data stream which can be utilized to the user's specific application. An RS232 lead with the following connection will be required to link the instrument with the PC serial input. Meter PC (3.5 mm jack plug) (9W 'D" Connector) Center Pin...Pin 2 Ground/shield... Pin 5 7

The 16 digit data stream will be displayed in the following format : D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Each digit indicate the following status : D0 End Word D1 to D8 Display reading, D1=LSD, D8=MSD For example : If the display reading is 1234, then D8 to D1 is 00001234 D9 Decimal Point ( DP ) for Upper display. 0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP D10 Polarity 0 = Positive 1 = Negative D11 & D12 Annunciator for Upper Display mbar = 86 psi = 23 mm Hg = 78 inch Hg = 80 inch HF2 = 25 Kg/cm 2= 77 Atmosphere = 26 meter HF2 = 79 D13 1 D14 4 D15 Start Word 7. BATTERY REPLACEMENT 1) When the left corner of LCD display show " LBT ", it is necessary to replace the battery. However, in-spec measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2) Slide the Battery Cover ( 3-10, Fig. 1) away from the instrument and remove the battery. 3) Install a 9 V battery (PP3 type) and replace the cover. 8 0101-PM-9107