BACnet Protocol Implementation Conformance Statement OEMPrtl Pro

Similar documents
BACnet Protocol Implementation Conformance Statement Automated Logic Corporation LGR25, LGR250, LGR1000

BACnet Protocol Implementation Conformance Statement Unitary Protocol Converter (UPC)

BACnet Protocol Implementation Conformance Statement Automated Logic G5RE

MatrixBBC. Protocol Implementation Conformance Statement (PICS) Product Description: BACnet Standardized Device Profile:

entelibus CPU Engine (eb-eng) Firmware

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

Delta Controller Engine (DCE) Firmware

NB-GPC Family Protocol Implementation Conformance Statement (PICS)

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

PXC Compact Series on BACnet/IP

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

BCM-ETH BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

Date: Vendor Name: Product Name: Product Model Number: Applications Software Version: Firmware Revision: BACnet Protocol Revision:

Wireless Pneumatic Thermostat BACnet Gateway PICS. Document No rev 01

TRIDIUM NIAGARA AX 3.8

! BACnet Operator Workstation (B-OWS)! BACnet Advanced Operator Workstation (B-AWS)! BACnet Operator Display (B-OD)

IQ4NC/.../ BACnet PICS

1. BACnet Protocol Implementation Conformance Statement

1. BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

EC-Net AX /NIAGARA AX Framework 3.5 BACNET PICS

FX Server BACNET AWS Protocol Implementation Conformance Statement

HMS-1655 BACnet MS/TP Protocol Implementation Conformance Statement

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

S4 Open: BACnet N2 Router

EC-Net AX 3.6 BACnet PICS

Distech Controls Application Specific Controllers PICS

BACnet Protocol Implementation Conformance Statement

SAUTER BACnet PICS EY-modulo 5 ecos504/505 BACnet Protocol Implementation Conformance Statement

Visi.Plus Protocol Implementation Conformance Statement (PICS)

Additional BACnet Interoperability Building Blocks Supported (Annex K):

BACnet Protocol Implementation Conformance Statement

Product Implementation Conformance Statement bcx1-r

BACnet Protocol Implementation Conformance Statement

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

QC BAC-BOX PIC STATEMENT

Modular Series BACnet Protocol Implementation Conformance (PIC) Statement A6V Building Technologies

BACnet Protocol Implementation Conformance Statement

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

EC-Net AX 3.6 BACnet PICS

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

PXC Compact Unitary Equipment Controller BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement (PICS) der Automationsstation miles-as29/b

Integration Specification Sheet

DDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1

Protocol Implementation Conformance Statement (PICS)

Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

ENC/JACE/NXT G3 Release 3.6 Network Controllers

BACnet Protocol Implementation Conformance Statement

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

BACnet Protocol Implementation Conformance Statement

CAS BACnet Stack Product Data Sheet

homelynk/spacelynk BACnet Protocol Implementation Conformance Statement

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

DS-RP-A AE-N-I-B DM-DCC-B DS-RP-B AE-ACK-B DM-PT-A DS-RPM-B AE-ASUM-B DM-PT-B DS-WP-A AE-INFO-B DM-TS-A DS-WP-B DM-DDB-B DM-UTC-B

BACnet Protocol Implementation Conformance Statement (PICS) MULTICAL 62/601/602/6L2/6M2/801

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3

BACnet Protocol Implementation Conformance Statement

Input/Output Module (IOM) Series Protocol Implementation Conformance Statement

NXAC-120 Area Controller

ETC Reference Guide BACnet PICS for P-CCS

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

BACnet protocol implementation conformance

MicroTech II Multiple Air Handler Controller

MULTICAL 403 MULTICAL 603

BACnet Protocol Implementation Conformance Statement (PICS) Product Discription V1.0

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

Sales and Engineering Data Sheet ED

Building Operation. Vendor ID 10

BACnet Protocol Implementation Conformance Statement

Honeywell Novar XIO Remote I/O Protocol Implementation Conformance Statement (PICS)

PXC Modular Series for BACnet Networks

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

BACnet protocol implementation conformance statement (PICS)

BACnet protocol implementation conformance statement (PICS)

PICS EE160D & EE210D BACnet Protocol Implementation Conformance Statement

Product Implementation Conformance Statement bcx-4040

SyxthSense Room Controller (SRC1) Platform. BACnet Protocol Implementation Conformance Statement

BACnet IP Enabled InFusion Controller Bacnet-IP-IC BACnet Protocol Implementation Conformance Statement

Functional Specifications Gateway

Protocol Implementation Conformance Statement (PICS)

SITRANS F. Ultrasonic Flowmeters SITRANS F US Clamp-on Communications Module. Introduction 1. F US Clamp-on Communications Module Kit 2

BACnet Protocol Implementation Conformance Statement

BACnet Simulator User s Manual

BACnet RIB July 1, 2014

Swegon GOLD BACnet PICS Version E BACnet Protocol Implementation Conformance Statement

PICS_EE10D // v1.0 / Technical data subject to change. PICS EE10D BACnet Protocol Implementation Conformance Statement

Transcription:

Date: 12/13/2011 Vendor Name: OEMCtrl Product Name: Product Model Number: Applications Software Version: <user specified> Firmware Revision: 4.02 BACnet Protocol Revision: 9 Product Description: The is an extremely powerful, high-speed device router and gateway. It can connect hundreds of controllers to a BACnet/IP backbone. Supports communications for BACnet/IP, BACnet-over-Ethernet, ARC156, MS/TP, BACnet PTP, Modbus, N2, and LonWorks*. A wide range of open and proprietary protocol translator drivers allow the OEMPrtl Pro to also serve as a gateway to other manufacturers equipment. BACnet Standardized Device Profile (Annex L): BACnet Operator Workstation (B-OWS) BACnet Building Controller (B-BC) BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) BACnet Smart Sensor (B-SS) BACnet Smart Actuator (B-SA) List all BACnet Interoperability Building Blocks Supported (Annex K): DS-RP-B DS-RPM-B DS-WP-B DS-WPM-B DS-COV-A DS-COV-B DS-COVU-A DS-COVU-B DS-RP-A DS-RPM-A DS-WP-A DS-WPM-A AE-N-I-B AE-ACK-B AE-ASUM-B AE-INFO-B AE-ESUM-B SCHED-I-B SCHED-E-B T-VMT-I-B T-ATR-B NM-RC-B DM-DDB-A DM-DDB-B DM-DOB-A DM-DOB-B DM-DCC-B DM-PT-A DM-PT-B DM-TS-B DM-UTC-B DM-RD-B DM-LM-B DM-BR-B DM-R-B Segmentation Capability: Able to transmit segmented messages Able to receive segmented messages Window Size 1 Window Size 1 Standard Object Types Supported: An object type is supported if it may be present in the device. For each standard Object Type supported provide the following data: 1) Whether objects of this type are dynamically creatable using the CreateObject service 2) Whether objects of this type are dynamically deletable using the DeleteObject service 3) List of the optional properties supported 4) List of all properties that are writable where not otherwise required by this standard 5) List of proprietary properties and for each its property identifier, datatype, and meaning 6) List of any property range restrictions (List of object types starts on page 3 ) Page 1 of 25

Data Link Layer Options: BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7) ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s) 156k baud_ MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 78600 MS/TP slave (Clause 9), baud rate(s): Point-To-Point, EIA 232 (Clause 10), baud rate(s): 9600, 19200, 38400, 57600, 115200 Point-To-Point, modem, (Clause 10), baud rate(s): 9600, 19200, 38400, 57600, 115200 LonTalk, (Clause 11), medium: Other: Device Address Binding: Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and certain other devices.) Yes No Networking Options: Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc. Ethernet-UDP/IP, Ethernet-PTP, BACnet/IP-UDP/IP, BACnet/IP-PTP, Ethernet-BACnet/IP, Ethernet- BACnet/IP-UDP/IP, Ethernet-BACnet/IP-PTP, ARCNET-UDP/IP, ARCNET-PTP, Ethernet-ARCNET, Ethernet-ARCNET-UDP/IP, Ethernet-ARCNET-PTP, BACnet/IP-ARCNET, BACnet/IP-ARCNET- UDP/IP, BACnet/IP-ARCNET-PTP, Ethernet-BACnet/IP-ARCNET, Ethernet-BACnet/IP-ARCNET- UDP/IP, Ethernet-BACnet/IP-ARCNET-PTP, MS/TP-UDP/IP, MS/TP-PTP, Ethernet-MS/TP, Ethernet-MS/TP-UDP/IP, Ethernet-MS/TP-PTP, BACnet/IP-MS/TP, BACnet/IP-MS/TP-UDP/IP, BACnet/IP-MS/TP-PTP, Ethernet-BACnet/IP-MS/TP, Ethernet-BACnet/IP-MS/TP-UDP/IP, Ethernet- BACnet/IP-MS/TP-PTP Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BBMD support registrations by Foreign Devices? Yes No Character Sets Supported: Indicating support for multiple character sets does not imply that they can all be supported simultaneously. ANSI X3.4 IBM /Microsoft DBCS ISO 8859-1 ISO 10646 (UCS-2) ISO 10646 (UCS-4) JIS C 6226 If this product is a communication gateway, describe the types of non-bacnet equipment/networks(s) that the gateway supports: Various protocols, depending on which firmware is loaded. Page 2 of 25

Analog Value (PAR): acked-transitions cov-increment deadband event-time-stamps high-limit limit-enable low-limit priority-array cov-increment deadband high-limit limit-enable low-limit present-value units present-value limited by min-pres-value and max-pres-value properties limited by min-pres-value and max-pres-value properties must be valid 0 to 4294967295 Page 3 of 25

Analog Value (RS): cov-increment present-value units cov-increment None Page 4 of 25

Analog Value (STAT): acked-transitions cov-increment deadband event-time-stamps high-limit limit-enable low-limit cov-increment deadband high-limit limit-enable low-limit units must be valid 0 to 4294967295 Page 5 of 25

Binary Value (PAR): acked-transitions active-text alarm-value change-of-state-count change-of-state-time elapsed-active-time event-time-stamps inactive-text minimum-off-time minimum-on-time priority-array time-of-active-time-reset time-of-state-count-reset active-text alarm-value change-of-state-count elapsed-active-time inactive-text minimum-off-time minimum-on-time present-value active-text change-of-state-count 0 to 4294967295 elapsed-active-time 0 to 4294967295 inactive-text minimum-off-time 0 to 4294967295 Page 6 of 25

minimum-on-time 0 to 4294967295 must be valid 0 to 4294967295 Page 7 of 25

Binary Value (CLOCK): acked-transitions active-text alarm-value change-of-state-count change-of-state-time elapsed-active-time event-time-stamps inactive-text minimum-off-time minimum-on-time priority-array time-of-active-time-reset time-of-state-count-reset active-text alarm-value change-of-state-count elapsed-active-time inactive-text minimum-off-time minimum-on-time present-value active-text change-of-state-count 0 to 4294967295 elapsed-active-time 0 to 4294967295 inactive-text minimum-off-time 0 to 4294967295 Page 8 of 25

minimum-on-time 0 to 4294967295 must be valid 0 to 4294967295 Page 9 of 25

Binary Value (STAT): acked-transitions active-text alarm-value change-of-state-count change-of-state-time elapsed-active-time inactive-text minimum-off-time minimum-on-time time-of-active-time-reset time-of-state-count-reset event-time-stamp active-text alarm-value change-of-state-count elapsed-active-time inactive-text minimum-off-time minimum-on-time active-text change-of-state-count 0 to 4294967295 elapsed-active-time 0 to 4294967295 inactive-text minimum-off-time 0 to 4294967295 minimum-on-time 0 to 4294967295 must be valid 0 to 4294967295 Page 10 of 25

Binary Value (MODULE ALARM): acked-transitions alarm-value event-time-stamps alarm-value must be valid 0 to 4294967295 Page 11 of 25

Calendar: date-list date-list limited to 30 BACnetCalendarEntrys Page 12 of 25

Device: active-cov-subscriptions active-vt-sessions apdu-segment-timeout backup-failure-timeout configuration-files database-revision multi-max-master multi-max-info-frames multi-mstp-network-numbers last-restore-time list_of_session_keys local_date local_time location max-segments-accepted vt-classes-supported utc-offset time-synchronization-recipients max-master max-info-frames last-restart-reason time-of-device-restart restart-notification-recipients utc-time-synchronization-recipients time-synchronization-interval align-intervals interval-offset object-identifier object-name location local-time local-date utc-offset apdu-segment-timeout apdu-timeout number-of-apdu-retries time-recipient max-master max-master-frames multi-max-master multi-max-info-frames backup-failure-timeout last-restart-reason Page 13 of 25

restart-notification-recipients utc-time-synchronization-recipients time-synchronization-interval align-intervals interval-offset 5. Proprietary properties: Property no. Property name 4146 file-free-size 4147 file-overhead-size 4149 auto-identity-scheme 4150 auto-identity-base 4153 serial-number 4162 test-mode location max-master 1 to 127 object-identifier must be a valid device identifier object-name utc-offset -780 to 780 last-restart-reason limited to BACnetRestartReason restart-notification-recipients 0 to 10 BACnetRecipients last-restart-reason limited to BACnetRestartReason File: archive file-type file-size modification-date read-only file-type Page 14 of 25

Loop Object (BACnet PID): 1. Creatable? No 2. Deletable? No Description Update_interval Proportional_constant Proportional_constant_units Integral_constant Integral_constant_units Derivative_constant Derivative_constant_units Bias COV_increment 4. Writable properties: Description Update_interval Action Proportional_constant Integral_constant Derivative_constant Bias 5. Proprietary properties: Continuous_proportional Deadband Ramp_time 6. Range Restriction: Property no. Property name Property Restrictions DataType 4163 Continuous_proportional Can only be 0 or 1 Boolean 4164 Deadband Must be >=0 Real 4165 Ramp_time Must be >=0 Real Page 15 of 25

Multi-State Value (PAR): acked-transitions alarm-values event-time-stamps fault-values priority-array state-text alarm-values fault-values present-value must be valid present-value must be valid state must be valid state 0 to 4294967295 Page 16 of 25

Multi-State Value (CLOCK): acked-transitions alarm-values event-time-stamps fault-values priority-array state-text alarm-values fault-values present-value must be valid present-value must be valid state must be valid state 0 to 4294967295 Page 17 of 25

Multi-State Value (STAT): acked-transitions alarm-values event-time-stamps fault-values state-text alarm-values fault-values must be valid present-value must be valid state 0 to 4294967295 Page 18 of 25

Notification Class: ack-required priority recipient-list None recipient-list limited to 5 BACnetDestinations Page 19 of 25

Program: -of-halt instance-of program-location reason-for-halt program-change program-location program-location Page 20 of 25

Schedule (ENUM): exception-schedule weekly-schedule effective-period exception-schedule priority-for-writing weekly-schedule list-of-prop-reference schedule-default limited to 30 BACnetSpecialEvents, exception-schedule each being limited to 6 BACnetTimeValues present-value 0 to 4294967295 0 to 4294967295 weekly-schedule limited to 6 BACnetTimeValues per BACnetDailySchedule schedule-default 0 to 4294967295 limited to 4 BACnetReliability limited to Boolean Page 21 of 25

Schedule (UNS): exception-schedule weekly-schedule effective-period exception-schedule priority-for-writing weekly-schedule list-of-prop-reference schedule-default limited to 30 BACnetSpecialEvents, exception-schedule each being limited to 6 BACnetTimeValues present-value 0 to 4294967295 0 to 4294967295 weekly-schedule limited to 6 BACnetTimeValues per BACnetDailySchedule schedule-default 0 to 4294967295 limited to 4 BACnetReliability limited to Boolean Page 22 of 25

Trend-log (of a non-bacnet property, COV or polled): acked-transitions client-cov-increment cov-resubscription-interval event-time-stamps last-notify-record log-interval notification-threshold records-since-notification start-time stop-time align-intervals interval-offset buffer-size client-cov-increment cov-resubscription-interval log-enable log-interval notification-threshold record-count start-time stop-time stop-when-full log_interval 0 to 4294967295 notification_class must be valid notification_class notification_threshold 0 to 4294967295 record_count can only be written to 0 logging-type limited to 3 BACnetLoggingType align-intervals limited to Boolean interval-offset 0 to 4294967295 in hundredths of seconds Page 23 of 25

trigger limited to Boolean limited to 4 BACnetReliability Trend-log (of a non-bacnet property, triggered): acked-transitions client-cov-increment cov-resubscription-interval event-time-stamps last-notify-record log-interval notification-threshold records-since-notification start-time stop-time trigger buffer-size client-cov-increment cov-resubscription-interval log-enable notification-threshold record-count start-time stop-time stop-when-full trigger log_interval 0 to 4294967295 notification_class must be valid notification_class notification_threshold 0 to 4294967295 record_count can only be written to 0 Page 24 of 25

logging-type align-intervals interval-offset trigger limited to 3 BACnetLoggingType limited to Boolean 0 to 4294967295 in hundredths of seconds limited to Boolean limited to 4 BACnetReliability Page 25 of 25