Installation and Setting-Up Instructions Spare Parts List

Similar documents
HK-H375A HART. Hand Held Communicator. Manual

Humidity limits % RH; freezing of condensed water not allowed in reference pressure channels.

H375A HART. Hand Held Communicator. Manual

Advanced Test Equipment Rentals ATEC (2832)

HART Communicator. MAN 4275A00 PN: English July 2000

Installation and Setting-Up Instructions Spare Parts List

SATRON VL Pressure Transmitter

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

Explosion-Proof Gauge Pressure Transmitter

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Advanced Test Equipment Rentals ATEC (2832)

Dissolved Oxygen (DO) Transmitter SMARTPro HART Command Specification

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

KOBOLD PDA Series Digital Pressure Transmitter

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

User s Manual. Model EJA Series HART Protocol. IM 01C22T01-01E 6th Edition. Yokogawa Electric Corporation IM 01C22T01-01E

DELTA CONTROLS CORPORATION

FOSTEN AUTOMATION SÉRIE F500-A

HART Protocol User Manual Rev. 1.0 December, 2014

914L. Capacitive Level Transmitter. Features. 1 Datasheet 914L Capacitive level transmitter for liquids.

Smart Wireless THUM Adapter

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

Page SATRON VT Pressure transmitter 7 SATRON VB Pressure transmitter 15

Rosemount 2051G Pressure Transmitter

FOSTEN AUTOMATION SÉRIE F500-SRT

Oldham OLCT 200 Revision 1

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

FIELDVUE Digital Valve Controllers. Tri-Loop Signal Converter Operation with FIELDVUE Digital Valve Controllers

Cerabar S. Brief Operating Instructions PMC71, PMP71, PMP75. Process pressure measurement

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

FUJI HART EXPLORER INSTRUCTION MANUAL

THZ 2 & TDZ 2 THZ 2 & TDZ. 2 Programmable Smart HART. TPRG Programmable Smart HART. Temperature Transmitter and Display. November D

914S. Capacitive Sanitary Pressure Transmitter. Features. 1 Datasheet 914S Capacitive Sanitary Pressure Transmitter

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DELTA CONTROLS CORPORATION

HART 7.x Field Device Specification for Honeywell ST 800 Smart Pressure Transmitters Document Number: 34-ST Revision: 1.

INSTALLATION & OPERATION MANUAL IPX/PX SERIES OF SMART MULTI-VARIABLE PRESSURE TRANSMITTERS

Installation and Setting-Up Instructions

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL May/2018 VTT10-FH. HART TEMPERATURE TRANSMITTER field model

HART UNIVERSAL TEMPERATURE TRANSMITTER

Quick Start Guide. Tek-Bar 3120A. 796 Tek Drive, Crystal Lake, IL USA

HART UNIVERSAL TEMPERATURE TRANSMITTER

HART Density Gauge Datasheet

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

Differential Pressure Transmitter STK336

InCos-P Pressure sensor 20 Pa Pa

MODEL 173 PROBE TYPE LEVEL TRANSMITTER With HART INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS DELTA CONTROLS CORPORATION

YTA610 and YTA710 Temperature Transmitters (HART Protocol)

FlexBar HRT Pressure Transmitter

Electrical Measurement Module Kit with Docking Station

Datasheet DE DB_EN_DE45_LCD Rev. ST4-G 11/17. Digital differential pressure switch / transmitter with colour-change LCD * *

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

KROHNE H250 SN /01-03 MC H250/RR/M9/K2/ESK-Z C K F CIV MD C2H50H D 0.93 kg/l V 2.5 mpa.s T 23.5 C P 0.

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

HART Applications SEC-5000 Gas Detector

Table of Contents. 1.1 General System Features Instrument Specifications Performance Specifications 12

DP DP2500 DP0250

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

RS-FS-N01 Wind speed transmitter user's Guide (485type)

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

JT400 Multivariable Transmitter

DTM - HART SERIES 2000 and 2000-SAN

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Series ULT Ultrasonic Level Transmitter

HART Field Device Specification PR 5437 Device Revision 2

Druck DPI 620 advanced modular calibrator

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Temperature Switches

Technical Bulletin, HT/HM HART Module

JERGUSON MTII4300. Installation, Operation, & Maintenance Instructions IOM M per CDC

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

HIGH ACCURACY PRESSURE TRANSDUCERS

SCADAPack Modbus multivariable transmitter

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Fusion of electronic pressure sensor and analogue display.

Model 332 Differential Pressure Transmitter

Flow Measurement SITRANS F US Inline

Temperature process values at a glance

DM28 - Economical Digital Process and Strain Gauge Panel Meters

MDT 2000 Magnetostrictive linear position transducer

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

IK4A (with ONDA technology)

Quick Start Guide MC-III TM Flow Analyzer

LS 5000 series Vibration Level Switch for liquids

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Transcription:

M2, revision 2 Installation and Setting-Up Instructions Spare Parts List Contents: INSTALLATION. Mechanical installation.2 Electrical connections 2 SETTING UP 2. Using the 275 user interface 2.2 Setting up through HART 275 user interface 2.3 Using the 375 user interface 2.4 Setting up through HART 375 user interface 2.5 Setting up with Satron-pAdvisor Service Software 3 CONSTRUCTION AND OPERATION 4 PARTS LIST DOCUMENTS Technical Specifications: BLV8 Installation and Setting-Up Instructions: We reserve the right for technical modifications without prior notice. HART is a registered trademark of HART Communication Foundation. Hastelloy is the registered trademark of Haynes International. Viton is the registered trademark of DuPont Down Elastomers. Satron Instruments Inc. P.O.Box 22, FIN-3390 Tampere, Finland Tel.int. +358 207 464 800, Telefax +358 207 464 80 www.satron.com, info@satron.com

INSTALLATION VVe pressure transmitter is suitable for liquid level measurements in ground and rock tanks, and in open channels and ships' tanks. Transmitters can also be used in corrosive conditions and to measure contaminating liquids.. Mechanical installation Installation methods Adjustment Adjustment Flange or threaded sleeve! (0)* ()* (2)* E Installing a flange or a threaded sleeve *) See the selection table "Other mounting accessories" Figure - Installation methods 3 Ø6 The screws should not be tightened so much so that ref. pressure hose in the cable blocked! 45 Mounting recommendations: - Process connection direction: vertical - Cable entry direction: horizontal - Connector coupling direction, calibration direction: - vertical or horizontal Other considerations: 40 60 26 - Equipment cabinet is recommended for extremely demanding conditions. The equipment cabinet can be provided with heating. - Freezing of condensed water in reference pressure port must be prevented. Figure - 2 Mounting parts for cable 2

Dimensions (mm) Ø6 40 Std. PG9 35 min. R30 Ø22 00 P, maximum length 50 m 70 Housing type H, plug connector, DIN43650, no display, inlet PG9 35 75 Ø48 Housing type M, junction box/ terminal strip, no display, inlet M20x.5 Std. M20 x,5 70 Housing type N, junction box/ terminal strip, with display, inlet M20x.5 70 Std. M20 x,5 Figure -3a Dimensional drawings 3

Dimensions (mm) Housing type N, with plug connector, DIN43650 90 Std. PG9 Esc Enter Figure -3b Dimensional drawings Protection pipe 60 Ø23 / Ø27 9 x 4 60 50 Figure - 4 Clamp mounting on angle bracket Figure - 5 - mounting accessories code Flange mounting 32035403 4

.2 Electrical connections 2 Supply voltage and load of the transmitter according to the figure -8. We recommend shielded twisted-pair cable as signal cable. The signal cable should not be installed near high-voltage cables, large motors or frequency converters. The shield of the cable is grounded at the power supply end or according to the recommendations of the manufacturer of the used control system. Figure-6 Removing the PLUG junction box Open. Remove screw 2. Open 0044093 Position selection 3 x 90 400 250 000 Load / Ω 750 Tighten the screw 0.5....5 mm 2 500 250 Operating region Pg9 0 0 2 5 20 25 30 35 Supply voltage /V Min. load using HART - communication 250 Ω 40 R max = Supply voltage - 2 V I max I max = 20.5 ma using HART -communication I max = 23 ma (when the alarm current 22,5 ma is on) Figure -7 Adjusting the junction box position 0044092 Figure -8 Supply voltage and load capacity 30035453 30035455 30035455 ma - + ma Hart 3 2 Test - + + - Test Load 2 2 3 Power Load Power Figure - 9, wiring housing H Figure - 0, wiring housing M 5

ma Hart - + ma - + + - Test 2 3 Test Load Figure -, wiring housing N Load Power Power Figure -2, wiring housing N with DIN 43650 plug connection, code N---/-P Satron SI-Toole Orded code : M33000 Keyboard : Esc = Press Esc move back towards the top of the main menu. = Use the UP arrow key to move up on the current menu level or to increase the selected parameter value. = Use the DOWN arrow key to move down on the current menu level or to decrease the selected parameter value. Enter = Press ENTER to move to a lower level in a menu or to accept a command or parameter value. Figure - 3 Wiring with Satron SI-Toole Figure - 4 Transmitter with display, code N 2 SETTING UP Setting up is dependent on type of user interface and loaded description VALMET or SATRON. Also must be noted that when the older VALMET description is in use then the transmitter must be configured so that it can operate with the old VALMET description. The change from description to another is made by writing to MESSAGE-field either. VALMET or SATRON (Note, capital letters and dot in front). After writing the message the new description will be activated by switching transmitter's power OFF and ON again. 6

2. Using the 275 user interface Operation keys The six operation keys are located above the alphanumeric keyboard: The ON/OFF key (I/O) switches the user interface on and off. When you switch the user interface on, it starts looking for a HART transmitter connected to it. If the transmitter is not found, the message No Device Found. Press OK will be displayed. The ONLINE menu is displayed when the user interface finds the transmitter. (^) This key allows you to move upwards in menus and scroll lists forwards. (v) This key allows you to move downwards in menus and scroll lists backwards. (<) This two-function key allows you to move the cursor to the left and to go back to a previous menu. (>) This two-function key allows you to move the cursor to the right and to select a menu option. (>>>) The quick-selection key will start the user interface and display the quick-selection menu. You can define the desired menu as quick-selection menu. Function keys With function keys F, F2, F3 and F4 you can perform the program functions displayed above each function key. When you move in the software menus, the functions of these keys will change in accordance with the currently selected menu. 2.2 Setting up through HART 275 user interface After installing and connecting the transmitter, connect the user interface to the transmitter. The following menu is displayed: Measurement 2 Configuration 3 Information 4 Diagnostics To change the measuring range, unit damping time constant to output mode (linear/square-root), select Configuration. The following menu is then displayed: Range values 2 Detailed config To change the measuring range, select Range values. The selection displays the following menu: LRV (lower range value) 2 URV (upper range value) 3 LSL (lower sensor limit) 4 USL (upper sensor limit) 5 Min span (minimum span) 6 Apply values To change the measurement unit, damping time constant or output mode, select Detailed config from the Configuration menu. The selection displays the following menu: Damping 2 Pres. unit 3 Tempr. unit 4 Alarm current 5 Write protect 6 Lin. func 7 Diff El status 8 Burst mode 9 Burst option Poll addr Tag User function User funct. setup After these activities or if the transmitter is supplied with the ready configuration you must correct a zero error of the transmitter in a final installation position. Press Diagnostics and PV Zero calibr. Figure 2-275 user interface The selection displays the following menu: Give correct value for Zero pressure in... The current zero point will be shown in display and the final zero error correction can be done. 7

2.3 Using the 375 user interface The following menu is then displayed: Measurement 2 Configuration 3 Information 4 Diagnostics 5 Review To change the measurement unit, damping time constant or output mod, select Configuration. The following menu is then displayed: Range values 2 Output 3 Tranfer function 4 General setup To change the measurement unit, select Range values. The following menu is then displayed: LRV 2 URV 3 LSL 4 USL 5 Min span 6 Apply values To change the damping time constant, select Output from the Configuration menu. The following menu is then displayed: Damping 2 Alarm current To change the output mode, select Transfer function from the Configuration menu. The following menu is then displayed: Lin. func 2 User function data After these activities or if the transmitter is supplied with the ready configuration you must correct a zero error of the transmitter in a final installation position. The First press Diagnostics and then Sensor trim and then Zero trim Figure 2-2 375 user interface 2.4 Setting up through HART 375 user interface The following text is then displayed : WARN-Loop be removed from automatic control The final zero error correction can be done to select ABORT or OK on the display. After installing and connecting the transmitter, connect the user interface to the transmitter. The following menu is displayed: Main menu. To select the HART Application. 8

R SATRON VVFe pressure transmitter 2.5 Setting-up with Satron-pAdvisor Service Software When you will have available all the operations of the Smart transmitter, we recommend the use of Satron-pAdvisor Service Software and Satron SI-Toole USB-Hart-modem in setting-up. Test connections for configuration and pressure/ output current values checking and calibration and for SENSOR TRIM function Recommended equipment for calibration Satron-pAdvisor service software for SATRON Smart transmitter (can be loaded free of charge from www.satron.com) PC: operating system Win-98, Windows 2000 or Windows XP) DMM: Digital multimeter, basic DCV accuracy better than 0,0 % of reading (for example Fluke 8840A, Keithley 2000) Cal. pressure generation and measurement device (accuracy better than 0,03 % of reading) USB-Hart modeemi, Satron SI Toole, tilauskoodi: M33000 Digital multimeter for output current measuring Um+ Si-Toole USB / HART modem www.satron.com USB Rx USB Tx HART Pwr OK + +5V 28mA 24V - Um- Ext. power in 4mA = 0.4V 00R 9... 30V 20mA = 2VDC 0.0% IL DC or AC Um+ 50R IP40 NOTE! Do not switch Vsup ON in live circuit Um+ Um- Vsup+ Rx HART R Tx Um- Vsup- Vsup ON/OFF PC VVFe transmitter Cal. pressure generation and measurement device Figure 2-2 Calibration connections window 9

Measurement PV Pres. AO % rnge LRV Sensor Housing URV LSL USL Configuration Range values Min Span Apply values 275 software tree (Valmet transmitters) 4 ma 20 ma ON LINE Detailed config Damping Pres. unit Tempr. unit Alarm current Write protect Lin.func Diff El status Burst mode Point pressure Burst option Point output Poll addr... Tag Point6pressure User function Point 6 output User funct. setup Ref. temperature Vol. temp.coeff. Manufacturer Model Information Device info Sensor s/n Message Universal rev Fld dev rev Software rev Hardware rev Descriptor Final asmbly num P-SMART special Selection code P-SMART Process seal Housing type Body/Flange mater Diaph/(+)diaph mat (-)diaphragm mater Diaphragm coating Extension material Fill fluid Explosion proof Diagnostics Device status flags Zero device status Loop test Loop calibr. PV Zero calibr PV Span calibr Digital inputs Date Tempr calibr. ALARM CPUEE ER ALARM ADSEN ER ALARM ADTS ER ALARM ADTH ER ALARM ELDR ER SCI ERR AD ERR HA FR ERR HA DA ERR ADCEE ERR Reserved Reserved2 Sensor tempr cal Housing tempr cal 0

ON LINE Measurement Configuration PV Press AO % rnge Sensor Housing Range values Output Transfer function General setup LRV URV LSL USL Min Span Apply values Damping Alarm current Lin. func User function data Pres. unit Temp unit Write protect Tag Descriptor Message Date 4 ma 20 ma 275/375-software tree (Satron transmitters) User point cnt User unit USER Temp correction. Pres. Out... 6. Prs 6. Out Reference temp Vol. temp coeff. Information Measuring point Device info Construction info HART Manufacturer Model Dev Type Serial no. Sensor no. Device no. Software rev Hardware rev Selection code Process connection Housing type Body/flange mater Diaphragm mater (+) Diaphragm mater (-) Diaphragm coating Extension material Ext lenght code Fill fluid Explosion proof Temp code Process connect (-) Universal rev Fld dev rev Poll addr Burst mode Burst option Diagnostics Review Device status Sensor trim Output functions Temperature trim Other functions Self test Error info Statistics Zero trim Lower sensor trim Upper sensor trim Loop test Output trim Sensor temp trim Housing temp trim Master reset Factory defaults

3. CONSTRUCTION AND OPERATION Sensor Module The piezoresistive sensor, which has a silicone oil fill, is isolated from the process with a diaphragm. Sensor pressure and temperature are measured with a 24-bit AD converter. Linearity and temperature effects are digitally corrected with an internal microprocessor connected to the sensor module. The sensor converts pressure to electrical signal. The conversion is carried out through a Wheatstone bridge supplied with direct current. The elastic displacement produced in the bridge by the pressure causes bridge unbalance which is measured as a DC voltage signal. Electronics Module The electronics module converts the process pressure signal from the sensor module to 4-20 ma output signal. The conversion can be made in linear, square root or inverted mode, or it can be done through user-selectable pressure/output point pairs (2-6 points). Transmitters provided with own display (code N) is equipped with operating keys that allow you to define the transmitter s all functions. The active functions required for signal shaping are in a customized IC which is divided into two sub-blocks: amplifier block and standard-signal shaping block. The standard-signal shaping block also includes zero, span and damping adjustments. Compensation includes temperature compensation and linearization. Each sensor is calibrated individually through a resistance network connection. The temperature information required by compensation is derived from a temperature measuring element located by the Wheatstone bridge. The interface stage includes failure protections to ensure the transmitter's operation and nonfailure in possible failure conditions. This stage also includes the TEST and cable connections Sensor Module CPU Module Analog to Digital Conversion Non-Volatile Memory for Parameters - Correction Coefficients - Transmitter Information - Transmitter Configuration (Range Values, Damping, Lin.Funktion...) Microcontroller with Flash-memory Functions - Range Settings - Damping - Diagnostic - Units - Communication - Transfer function - Correction Calculation for Temperature and Linearization Interface Stage - Failure protection - Test Connections - Cable connections Analog Output HART Digital to Analog Conversion (4... 20mA) HART Digital Communication Module Temperature Temp. Sensor Pressure Sensor Module Abs. or Gage Pressure Sensor Temp. Sensor dp Sensor Module dp Sensor Display Module (optional) Buttons LCD-Display Pressure - + Differential Pressure Figure 3- Functional construction of the SATRON VVe pressure transmitter 30035456 4. PARTS LIST When ordering spares, please quote this document s number BLV80AV and date, the name and order number of the required part, and the transmitter s serial number. Parts indicated with asterisk (*) as well as screws, nuts and seals (packings) are spare parts. 2

3 3 2 9 8 4 0 Figure 4- Parts list: Housing with PLUG connector, code H 3 9 20 Figure 4-2 Parts list: Housing with junction box, code M 3 2 22 23 Figure 4-3 Parts list: Housing with junction box and display, code N 32035405 3

Number Name Order number Number Name Order number 2 * 3 4 Sensing element Seal Device plug DIN43650 Cylinder-head screw M3 x 0 SFS279 Zne T300207 729004 560302 9 * 20 2 * 22 23 O-ring, 42x2 FPM (Viton ) Cover M Seal, Silicone rubber Back plate V Fastening screw M4 8003800 T300256 T300387 T30039 T325347 8 Seal GDM3-7,silicone 729006 * 9 0 Wiring box GDM3009, DIN43650 Cylinder-head screw S M3 x 35 SFS279 A4 72900 5723053 Cylinder-head screw S M3 x 4 VSM 3302 Zne 563009 * 3 * 3 Protection cup, housing H, M and T Protection cup, housing N T300295 T300400 Satron Instruments Inc. P.O.Box 22, FIN-3390 Tampere, Finland Tel.int. +358 207 464 800, Telefax +358 207 464 80 www.satron.com, info@satron.com 4