EnergyLok Environmental Monitoring System 300 Product Training. Stephanie Christensen National Account Manager 03/24/16

Similar documents
WIRELESS ENVIRONMENTAL MONITORS

Automation Monitoring Control. EDN 2010 Hot 100

User Manual. Per Port Monitoring Models

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

VT805 / Monitoring system

Monitoring system LN-VT325. Environmental Infrastructure monitoring

VT608 / Switched PDU with 8 outlets

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

ROOM GUARD VT335. Environmental Infrastructure monitoring

BACnet Controller for General-purpose Building Applications

Comprehensive Data Center Energy Management Solutions

ROOM GUARD VT335. Environmental Infrastructure monitoring

The Four 4R s. of Data Center Airflow Management. About Upsite Technologies

Environmental Monitor (RSMICRO)

Product Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102

Features and Benefits. Certifications

HYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home

NetBotz Wireless Environmental Monitoring

M a/b/g Outdoor Layer-2 MESH AP

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

StruxureWare TM. Data Center Expert. Data Center Infrastructure Management (DCIM) Software

Connector for sensing cable

Geist EMEA. Geist USA. Geist APAC

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Data Center Infrastructure Management (D.C.I.M.)

Model# ANI SWH. Ver. 1.1

ZLJ\YP[`7YVIL, :[HUKHYK

PowerNetGuard INVENTORY MANAGER SOFTWARE HIGHLIGHTS. Features

RAMP DCIM Data Center Infrastructure Management Software

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories

[SmartX Controller ] Introduction. Features. SmartStruxure solution

EP2 EP8 User Manual. Copyright 2007,ATAL

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

sensorprobe2 / sensorprobe8 User Manual

Monitoring. WiNG System. User Guide. WiNG-MGR WiNG-RXT. Version 1.3 Firmware Version 3.3.2

Software and accessories

Industrial Serial Device Server

Eaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved..

Poseidon 4002 MANUAL

Polar PDUs POWER MANAGEMENT

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

Industrial IOT Gateway Family Datasheet

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

Liebert GXT MT kva

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring

DLB 5-15B. Outdoor Wireless Device COPYRIGHT 2015 LIGOWAVE

Delivered the Way Yo u Want

ProtoConvert Modbus RTU / Modbus TCP/IP / BACnet MSTP / BACnet IP / SNMP - Telnet (Lighting Controller) PG

Technical Manual Nova: Cabinet Security Management System (CSMS)

Hardwired Uninterruptible Power Supply

MGate 5102-PBM-PN Series

Technical Overview CM-5 The Compact Climate Monitor Bundle. Get yours direct at:

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

LDALI ME204-U, LDALI ME201 U

Temperature Alert. LAN-based Temperature and Humidity Data Logger

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

MGate 5105-MB-EIP Series

DCIM Data Center Infrastructure Management

Installation, Operation, and Maintenance Lifetime Power Wireless Sensor System

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

NetCom Plus 113 (NetCom 113, NetCom 113 PRO)

DPM/DE19B/DEPC User Manual

The securityprobe5es-x20 s software motion detection and a rich notification suite keeps you up to date 24 hours a day. securityprobe5es-x20

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

Intelligent Monitoring. Taking intelligent monitoring to a higher level

NetCom Plus 111 (NetCom 111)

Data Center Infrastructure Management ( DCiM )

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

See it. Control it. The TelPro Solution

EC-BOS-8 Multi-protocol Web Building Controller

Network agent NetMan 101/102 Plus

EdaFastCam The Smart Clip-on Meter Reader for Home and Business

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

Eaton Power Xpert Gateway Series 2000 Card

Please See Inside for Detailed Information about our Controls...

LDALI ME204-U, LDALI ME201 U

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

EC-BOS-8 Multi-protocol Web Building Controller

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

May Delivers real-time, Web-enabled monitoring of electrical distribution and control equipment

All it takes to measure, collect and analyze energy consumption in heating and cooling applications

FAST EnergyCam. The Smart Clip-on Meter Reader for Home and Business

WISE-52xx Intelligent IIoT Concentrator

JetPort 5801 V3. Overview. 1-port RS-232/422/485 Wireless Serial Device Server INDUSTRIAL SERIAL DEVICE SERVER

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

Frequently Asked Questions

Data logger systems from ROTRONIC

Overview. Product Terminology. Autonomous Access Points. Lightweight Access Points CHAPTER

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

RN-174 WiFly Super Module

DIRIS Digiware D and C Communication and control power interfaces

Transcription:

EnergyLok Environmental Monitoring System 300 Product Training Stephanie Christensen National Account Manager 03/24/16

Introduction Environmental Monitoring Defined Consists of a variety of solutions developed to combat threats to a mission critical facility s environment and assure continuous business function Current Facility Monitoring Product 1. EnergyLok Environmental Monitoring System 200 (Wired Version) 2. Launched on 05/11/15 New Facility Monitoring Product 1. EnergyLok Environmental Monitoring System 300 (Wireless Version) 2. Launch Date 03/14/16 Ideal Monitoring Environments 1. Co-location Facilities 2. Small to Large Telecommunication Rooms 3. Small Data Centers 4. Enterprise Data Centers

DCIM Market Penetration According to the Uptime Institute s 2015 Data Center Industry Survey of over 1000 Data Center End Users: https://www.slideshare.net/fullscreen/uptimeinstitute/avoid-wasting-time-and-money-procuring-andimplementing-dcim/1

Why Monitoring Is Important You can t manage what you don t measure. 1. Save on cooling by confidently raising data center temperatures 2. Maintain cabinet security with contact closure sensors 3. Improve data center uptime by receiving environmental alerts 4. Make strategic decisions on environmental designs and modifications

Wireless Monitoring Technology Advantages: Lower Total Cost of Ownership (TCO) Multiple Wireless signal options (418MHz/433MHz) Auto Discovery & Configuration Easier To Maintain Increased Scalability Improved Battery Life

EnergyLok EMS 300 Up to 150 wireless temperature, temperature /humidity or leak detection sensors with a range up to 100ft indoor or 1,300ft open air transmission with Wireless Point Repeater 4 digital inputs, 2 Relay Outputs, 2 Dry contacts Multiple alarm notification configurations including audible and visible indicators, web interface, email messaging and SNMP traps Modbus output enables simple integration to a Building Management Systems (BMS), Network Management Systems (NMS) & (DCIM) Data Center Infrastructure Management System Access to web interface from mobile device Built-in logging, trending and downloadable data

EnergyLok EMS 300 Anatomy Relay Outputs (2) Digital Inputs(4) Status LED On=Alarm RS232 Port (hyperterminal) RS485 Communication Status EIA-485 Connection Grounding Wire 418MHz or 433 MHz Antennas 900MHz or 2.4 GHZ Antennas Hardwired Power Supply RS485 Termination Resistor 24VAC Power Supply RJ45 Network Port

EnergyLok EMS 300 Parts Included Equipment Mounting Brackets (2) EMS 300 Manager 418MHz (domestic use) or 433 MHz (international use) Antennas (1) Not Shown Plug in Wall Adapter (1) Network crossover cable (1) Wall Adapter is specific to region (dom. vs. int.) 900MHz Antenna (1)

EnergyLok EMS 300 Web Interface Homepage basic information: Current alarm status Data points Configuration Most compatible with Internet Explorer and Firefox

EnergyLok EMS 300 Communication Protocols TCP/IP: ARP; DNS; UDP; DHCP; ICMP Modbus RTU Modbus TCP/IP: Modbus slave; TCP/IP transmission protocol BACnet MSTP: EIA-485 BACnet/IP: ASHRAE STD 135-2004 Annex J SMTP (email): SMTP authentication; SMTP relay; supports SSL; up to 8 recipients SNMP: V1; V2C MIB-2 compliant; NMS Manageable with Get and Traps: V2C Get, V2C and V1 Traps

EnergyLok EMS 300 Accessories Wireless Temperature Sensor 1. Part Numbers 300-TSR-001 or 300-TSR-002 (INT) 2. +/- 1 degree F 3. Transmission range up to 100 feet indoors 4. 3.6V lithium AA battery 5. Up to 4 year battery life Wireless Temperature/Humidity Sensor 1. Part Numbers 300-THS-001 or 300-THS-002 (INT) 2. Digital Temp/Hum measurement 3. Transmission range up to 100 feet indoors 4. 3.6V lithium AA battery 5. Up to 3-4 year battery life Wireless Leak Detection 1. Part Number 300-WLD-001 2. Couples with up to 50 of sensing cable or spot detector 3. Transmission range up to 100 feet indoors 4. 3.6V lithium AA battery 5. Up to 2-3 year battery life

EnergyLok EMS 300 Accessories Wireless Temperature Sensor with Digital Input 1. Part Numbers 300-TSD-001 or 300-TSD-002 (INT) 2. Digital Temperature measurement and dry contact input 3. Up to 100 feet indoors 4. 3.6V lithium AA battery 5. Up to 4 year battery life Wireless Point Repeater 1. 900MHZ 2. Extends signal 3. 1,300ft 4. Increases range 5. Indoor/Outdoor applications

Compatible EnergyLok EMS 200 / 300 Accessories

Unique Selling Features EnergyLok Environmental Monitoring System 300 Value Proposition The EnergyLok EMS 300 provides managers of mission critical spaces a scalable and affordable wireless environmental monitoring system that integrates seamlessly into most facility management systems. Key Selling Points Seamless Integration Wide variety of protocols for seamless integration Integrated email notification and web based dashboard allow it to work well as a standalone system Easy to install and manage, with an auto-discovery feature and user-friendly web interface 2 relay outputs and 4 digital inputs available Scalable Can be easily scaled with up to 150 wireless sensors; potential for up to 400 sensors Affordable Has no annual licensing fee and free firmware updates Battery life Features a replaceable lithium ion battery, which can last up to 4 years at 10-17 second intervals

Other Info EMS Technical Support: upsiteems@upsite.com

Questions