SCSI HP Administrator s. Vectra PCs Guide. Kayak PC

Similar documents
Installation Guide AHA-2930B. PCI-to-Fast SCSI Host Adapter with SCSISelect

Installation Guide AHA-1540CP/1542CP. ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility

SCSI device drivers are provided for the following operating systems:

Installation Guide AHA -1530P/1532P. Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility

SUPERMICRO RAID Port Manual

Tower to Rack and Rack to Tower System Conversion Guide

Appendix A Fast!UTIL

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

hp digital home networking phoneline USB network adapter hn210p quick start guide

USER S REFERENCE SCSI CARD 2940U2W

Computer Setup (F10) Utility Guide HP Compaq d220 and d230 Microtower

HP NetServer E 800 Installation Guide

Installation Guide AHA-1540CF/1542CF. High-Performance Bus Master ISA-to-SCSI Host Adapter with SCSISelect

Replacing the Battery HP t5730 and t5735 Thin Clients

User s Guide. HP Vectra VL 5/xxx

AHA-3980/3980W AHA-3985/3985W

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Model A4268A FWD SCSI Adapter Installation and Service Guide. Embedded Systems Operation Part No. A Edition E1097

Quick Setup & Getting Started

Upgrading and Servicing Guide

Upgrading and Servicing Guide

service handbook chapter

For Removable Docking Modules with 3.5"/2.5" HDD. or Optional for zip /SuperDisk LS-120/MO/TR-4 Tape or ATA Flash Memory Reader

Upgrading and Servicing Guide

Getting Started. HP Business PCs

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

Data Protector Express Hewlett-Packard Company

AHA-2940UW/OF and AHA-2944UW/OF

HP Server tc2110 Network Operating System Installation Guide

Computer Setup (F10) Utility Guide HP Elite 7000 MT Series PCs

AHA-1540C/1542C Installation Guide

SCSI Adapter. A device-independent interface for attaching tape drives. Documentation Edition 2

Getting Started. HP Business PCs

Upgrading and Servicing Guide

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

Upgrading and Servicing Guide

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

FASTTRAK S150 TX4 QUICK START GUIDE. Version 1.2

HP / HP HPIB Driver Installation and Troubleshooting ChemStation Version A.07.0x- A.08.0xon Windows NT

82341C HPIB Installation and Troubleshooting Agilent ChemStations on Windows 95 and Windows NT

Rocket 133/133S/133SB User s Manual. Revision: 1.1 Date: Dec HighPoint Technologies, Inc.

Upgrading the MSA1000 for Enhanced Features

Version 1.0 March 2014 OLC 10.1

Upgrading and Servicing Guide

HP OmniBook DiagTools. User s Guide

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

HP NetServer LC 3 User Guide

Computer Setup (F10) Utility Guide HP Business Desktops dx5150 model

DesignJets 500 and 800 Series Large-Format Printers Service Manual

Wall-Mounting your HP TouchSmart. User Guide

Quick Setup & Getting Started Business PCs

FASTTRAK S150 TX2PLUS QUICK START GUIDE. Version 1.2

Compaq PowerStorm 300/AGP and 300/PCI Graphics Options Installation Guide

Getting Started Guide

FASTTRAK TX4000 USER MANUAL. Version 1.3

User Manual. August 2008 Revision 1.0. SKH300 ibutton Reader Configuration Utility

HP ProLiant DL580 Generation 2 and HP ProLiant ML570 Generation 2 Server Hot-Add Memory. July 2003 (Second Edition) Part Number

2500C/C+/CM. Professional Series Color Printer NETWORK GUIDE

Dell PowerEdge 2650 Systems User's Guide

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

LSI Integrated SCSI. LSI bit 2Ch. Ultra2 SCSI LSI bit 2Ch. Ultra160 SCSI LSI bit 2Ch. Ultra160 SCSI

Firmware Guide. Keysight PXIe Chassis Family

Dolphin TM 6500 Mobile Computer. Quick Start Guide

G-MAX TM. ATX Series User s Manual

Support for Non-Ultra2 SCSI Devices

Targus Memory Stick Reader for Notebook Computers

ADSP-218x Family EZ-ICE Hardware Installation Guide

HP Pocket Media Drive User s Guide. book title

TD220 System Resources

IBM Netfinity Servers

Tutorial. Includes lessons on transferring music to ipod, playing music, and storing files on ipod

Agilent 86121A WDM Channel Analyzer

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

User s Manual. USB 2.0 IDE External Enclosure. Table of Contents

hp l1619a smart attachment module

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

SCSI Hard Disk Drives For IBM PCs. User's Guide OPTIONS. by IBM

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

Configuring the MSA1000 for Linux or NetWare Environments

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

EVO-TM2A EVO-TM2B Touch Screen Monitor

Ultra ATA/133 RAID Card. User Manual

HP ProLiant Storage Server iscsi Feature Pack

Backpack Help and User's Guide rev

Laser Beam Printer. Network Guide. IMPORTANT: Read this manual carefully before using your printer. Save this manual for future reference.

Getting Started. HP Business PCs

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OBSAI Protocol Tester

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

LSIU40HVD PCI to Dual Channel SCSI Host Adapter

ICP RAID Software. Software Installation and User s Guide, Version June Preliminary

Installation and Hardware Guide. AAA-130 Series. PCI-to-Wide UltraSCSI Array Adapters

Backpack Hard Drive Help and User's Guide rev

Server Systems and Motherboards

Flexible Array Storage Tool. User s Guide

TeraJet DOCSIS Modem Installation. Guide

Transcription:

SCSI HP Administrator s Vectra PCs Guide SCSI HP Administrator s Kayak PC Workstations Guide

Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company. Adaptec is a registered trademark of Adaptec, Inc. Microsoft, MS, MS-DOS, Windows, and Windows NT are U.S. registered trademark of Microsoft Corporation. Netscape is a trademark of Netscape Communications Corporation. Pentium TM is a trademark of Intel Corporation. SCSISelect TM is a trademark of Adaptec Incorporated. Hewlett-Packard France Commercial Computing Operation 38053 Grenoble Cedex 9 France 1998 Hewlett-Packard Company

SCSI Administrator s Guide

Who This Manual Is For This manual is for anyone who wants to: Add a SCSI accessory to their PC. Configure a SCSI accessory in an HP PC. Important Safety Information WARNING If you have any doubt that you can lift the PC or display safely, do not try to move it without help. For your safety, always connect the equipment to a grounded wall outlet. Always use a power cord with a properly grounded plug, such as the one provided with this equipment, or one in compliance with your national regulations. This PC is disconnected from the power by removing the power cord from the power outlet. This means the PC must be located close to a power outlet that is easily accessible. For your safety, never remove the PC s cover without first removing the power cord from the power outlet, and any connection to a telecommunications network. Always replace the cover on the PC before switching it on again. To avoid electric shock, do not open the power supply. There are no user-serviceable parts inside. This HP PC is a class 1 laser product. Do not attempt to make any adjustment to the laser units. iv English

Configuring the SCSI Bus You can configure your PC s SCSI bus using the SCSISelect utility. This utility is for use with Internal Wide 16-bit SCSI devices. ATTENTION Using SCSI Select The SCSISelect utility is intended for advanced users only. Note that the SCSISelect option displayed on your screen may be different to the one described here. The SCSISelect utility is accessed by pressing <Ctrl><A> during the computer s start-up process when the message Press <Ctrl><A> for SCSISelect(TM) Utility! is displayed. The Options menu is displayed. SCSISelect(TM) Utility v1.xxx Would you like to configure the host adapter, or run the SCSI disk utilities? Select the option and press <Enter>. Press <F5> to switch between color and monochrome modes. Options Configure/View Host Adapter Settings SCSI Disk Utilities Arrow keys to move cursor, <Enter> to select option, <Esc> to exit Use the and keys and the key to make selections in the SCSISelect utility. Press at any time to return to the previous menu. English 1

Configure/View Interface Settings Menu It is recommended that you do not change these settings. SCSISelect(TM) Utility v1.xxx Configuration SCSI Bus Interface Definitions Host Adapter SCSI ID.............. 7 SCSI Parity Checking.............. Enabled Host Adapter SCSI Termination...Automatic Additional Options Boot Device Options.............. Press <Enter> SCSI Device Configuration........... Press <Enter> Advanced Configuration Options......... Press <Enter> <F6> - Reset to Host Adapter Defaults BIOS Information Interrupt (IRQ) Channel.............. 15 I/O Port Address................. F800h SCSI Channel Interface Definitions: Host Adapter SCSI ID Changes the adapter SCSI ID from its default value of 7. SCSI Parity Checking Enable or disable host adapter SCSI parity checking. Most currently available SCSI devices do support SCSI parity. You should disable SCSI Parity Checking if any of the attached SCSI devices do not support SCSI parity. Host Adapter SCSI Termination It is recommended that you leave this field on its default setting of Automatic. This way, if the host adapter detects a SCSI device connected to either its internal or external connectors, then it enables its terminators (the adapter is at the end of the SCSI bus). If the host adapter detects devices connected to both its internal and external connectors, then it disables its terminators. 2 English

Additional Options: Boot Device Options Press to display the Boot Device Configuration menu, described on the next page. SCSI Device Configuration Press to display the SCSI Device Configuration menu. Array 1000 BIOS (only if HP FastRAID is installed) This option is enabled by default, and instructs the system to use the special BIOS for the FastRAID option. Advanced Configuration Options Press to view the Advanced Configuration Options menu. Boot Device Configuration Menu This menu lets you configure the SCSI boot device. To find out the SCSI ID of a specific SCSI device, you can run the SCSI Disk Utilities (refer to page 7). Boot Boot Device Device Configuration Select SCSI peripheral from which to boot To view peripheral by ID# select SCSI Disk Utilities from previous menu Boot SCSI ID... 0 Option Listed Below Has NO EFFECT if MULTI LUN Support is Disabled Boot LUN Number... 0 Use the and keys to move between options. Press to display a menu with a selection of values. Boot SCSI ID This parameter is the SCSI ID of the boot device. The default value is 0. Boot Lun Number More advanced SCSI devices can have several logical units. This option indicates the logical unit (or Lun) on which to boot for the drive chosen in the Boot SCSI ID. The default value is 0. Use the HP Setup program to select the boot device. You enter Setup by pressing F2 during startup. English 3

SCSI Device Configuration Menu This menu lets you configure parameters for each SCSI device on the SCSI bus. To configure a specific SCSI device, you need to know which SCSI ID it uses. To know the SCSI ID of a specific SCSI device, you can run the SCSI Disk Utilities (refer to page 7). SCSI Device Configuration SCSI Device ID #0 #1 #2 #3 #4 #5 #6 #7 Initiate Sync Negotiation... yes yes yes yes yes yes yes yes Maximum Sync Transfer Rate.. 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 Enable Disconnection... yes yes yes yes yes yes yes yes Initiate Wide Negotiation... yes yes yes yes yes yes yes yes Options Listed Below Have NO EFFECT if the BIOS is Disabled Send Start Unit Command... no no no no no no no no BIOS Multiple LUN Support.. no no no no no no no no Include in BIOS Scan... yes yes yes yes yes yes yes yes SCSI Device ID #8 #9 #10 #11 #12 #13 #14 #15 Initiate Sync Negotiation... yes yes yes yes yes yes yes yes Maximum Sync Transfer Rate.. 40.0 40.0 40.0 40.0 40.0 40.0 40.0 40.0 Enable Disconnection... yes yes yes yes yes yes yes yes Initiate Wide Negotiation... yes yes yes yes yes yes yes yes Options Listed Below Have NO EFFECT if the BIOS is Disabled Send Start Unit Command... no no no no no no no no BIOS Multiple LUN Support.. no no no no no no no no Include in BIOS Scan... yes yes yes yes yes yes yes yes Use the and keys to move between options. Press to display a menu with a selection of values. Initiate Sync Negotiation Some older SCSI-1 devices do not support synchronous negotiation. Set Initiate Sync Negotiation to No for these devices. Maximum Sync Transfer Rate If the SCSI device is an UltraWide SCSI device, you can use the maximum value of 40.0 MB per second. For Ultra narrow SCSI or Wide SCSI devices you can select a maximum transfer rate of 20.0 MB per second. Certain older SCSI-1 devices do not support UltraWide SCSI (up to 40 MB per second) or Ultra narrow SCSI or Wide SCSI data transfer rates (up to 20 MB per second). Select a Maximum Sync Transfer Rate of 10.0 MB per second for these devices. 4 English

It is strongly recommended that you switch the Maximum Sync Transfer Rate to 20 MB per second when connecting an external SCSI device. Enable Disconnection To optimize SCSI bus performance, Enable Disconnection should be set to Yes. Initiate Wide Negotiation This option determines whether the SCSI channel attempts 16-bit data transfer instead of 8-bit data transfer. Send Start Unit Command When set to Yes this option reduces the load on your computer s power supply by allowing the interface to power-up SCSI devices one-at-a-time when you start your computer. This option is not supported by some SCSI devices. Some SCSI devices require a jumper to be changed before they can respond to this command. BIOS Multiple LUN Support More advanced SCSI devices can have several logical units (LUN). This option determines whether booting a SCSI device that has multiple LUNs is supported. Set this option to Yes if your boot device has multiple LUNs. It is set to no by default. Include in BIOS Scan This setting, when set to Yes, allows the SCSI device to be controlled by the host adapter with this SCSI ID. When set to No, the adapter does not control the SCSI device. English 5

Advanced Configuration Options Menu It is recommended that these settings are not changed. Advanced Configuration Options Plug and Play Scam Support...Disabled Extended BIOS Translation for DOS Drives > 1 GByte... Enabled Reset SCSI Bus at IC Initialization... Enabled Options Listed Below Have NO EFFECT if the BIOS is Disabled Host Adapter BIOS (Configuration Utility Reserves BIOS Space).. Enabled Support Removable Disks Under BIOS as Fixed Disks... Boot Only Display F6 Message During BIOS Initialization... Enabled BIOS Support for Bootable CD-ROM...Enabled BIOS Support for Int13 Extensions... Enabled Use the and keys to move between options. Press to display a menu with a selection of values. Plug and Play Scam Support When enabled, this option automatically configures Plug and Play compatible SCSI devices. For SCSI devices that do not support Plug and Play, set this option to Disabled. By default, it is enabled. Extended BIOS Translation for DOS Drives >1 GByte This option is no longer used (and must always be Enabled ). Reset SCSI Bus at IC Initialization When the SCSI controller receives an IC Reset command from the central processor, it can reset either itself and the SCSI bus, or just itself. By default, it will reset both itself and the SCSI bus. Host Adapter BIOS This option enables or disables the SCSI Adapter BIOS. Several options in SCSISelect utility are only valid if the SCSI adapter BIOS is enabled. The SCSI adapter BIOS must be enabled if the computer boots from a SCSI hard disk drive. This option is enabled by default. Support Removable Disks Under BIOS as Fixed Disks When Boot Only is selected, only the removable media drive designated as the boot device is treated as a hard disk drive. If All Disks is selected, all removable-media drives supported by the BIOS are treated as hard disk drives. No removable-media drives are treated as hard disk drives when Disabled is selected. In this case, removable-media drives must be controlled through operating system drivers. 6 English

Display <Ctrl><A> Message During BIOS Initialization When enabled, this option displays the message Press <Ctrl><A> for SCSISelect(TM) Utility! during BIOS initialization. When disabled, this message is not displayed, although you can still press the <Ctrl><A> key combination for the SCSISelect utility. This option is enabled by default. BIOS Support for Bootable CD-ROM When enabled, this option provides BIOS support to boot your PC from a CD-ROM device connected to the SCSI host adapter. BIOS Support for Int13 Extensions When enabled, this option provides BIOS support for hard disk drives with more than 1024 cylinders. It is enabled by default. SCSI Disk Utilities When the SCSI Disk Utilities are selected from the initial Options menu, the SCSISelect utility scans the SCSI bus and lists all the SCSI devices on the SCSI bus. The list shows the SCSI ID and name of each SCSI device. You can use this list to discover the SCSI ID of any device on the SCSI bus. Use the and keys to highlight a device and press to display the Format Disk/Verify Media menu. Format Disk This utility can be used to perform a low-level format of a hard disk. Most SCSI disks are pre-formatted and do not need low-level formatting. You should note that this function can take several hours. Verify Disk Media This utility scans for media defects on the selected SCSI device. Press the key to abort this utility English 7

PC Documentation Roadmap If you want to... Set up your computer Setup HP User s Guide Setting Up and Using Your PC Reference Learn how to use your operating system Learn how to upgrade your computer by installing accessories Find out how to administer your SCSI hard disk drives. Operating System Online Help Start Help Contents Operating System User s Guide HP User s Guide How to Install Accessories Inside Your PC (summary information only) Upgrade & Maintenance Guide, downloadable from: http://www.hp.com/go/vectrasupport This guide, downloadable from: http://www.hp.com/go/vectrasupport Troubleshooting and Support Find out about the different support options available, and how to troubleshoot your PC HP User s Guide HP Support and Information Services Part Number D6946-SAG-ABA Created in France - 09/98