Communication objects. Use of the application program. Note. Functional description. Parameters General

Similar documents
Use of the application program. Functional description. GAMMA instabus Application program description. March S1 rocker (BCU2)

Use of the application program

Use of the application program

EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO

Functional description. Use of the application program. GAMMA instabus Application program description. June C0 Sensor Switch

Use of the application program

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit

Use of the application program. Functional description. GAMMA instabus Application program description. April A4 Roller shutter switch

Din Rail 8 Input / 8 Output Module

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary

EAE KNX Room Control Unit Product Manual RCUXXYY

Contents. GAMMA instabus Application program - Descriptions. June B0 KNX / DALI Gateway Twin N 141/

Use of the application program

Push Button Interface UP 220D31

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Binary Inputs, 4 fold K-BUS R. User manual-ver. 1 CTBI-04/00.1. KNX/EIB Intelligent Installation Systems

K-BUS Binary Inputs. User manual-ver. 1

Push button UP 287, 4 - fold

Technical Manual MDT Push Buttons

MA /2015. User manual CU-DIN DRY 4-Z KNX EC

Push-button, 1-gang. (switch/neutral position) Programming push-button LED. Programming push-button LED. Ref.-No.

Philips LightMaster. KNX Commissioning Guide

Din Rail Universal Module 8 inputs / 8 outputs IO88E01KNX

Application description. KNX push-button 1gang. KNX push-button 2gang. KNX push-button 3gang. KNX push-button 4gang. Page 1/51

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

Application description. KNX Push-button module 1gang. KNX Push-button module 2gang

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product and functional description

DELTA i-system wall switch single UP 221/2 5WG AB_2

PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX. Product Handbook

Tebis application software

Operation and installation manual KNX IO 511 (1O2I) Application. 1. Installation and Connection

Application description. Motion detector KNX- BCU

Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX

EASY application description KNX room thermostat/room controller. Application description

Technical Manual MDT Glass push buttons

KNX/EIB Intelligent Installation Systems

KNX Communication. KNX Association

Application description

Technical Manual MDT Glass push buttons

Use of the application program

Application description

K-BUS Shutter Actuator. User manual-ver. 1

Use of the application program

Using the application program. Functional description. GAMMA instabus Application Program Description. October Event Module 800A06

B.IQ push button 3gang, Flush-mounted (Up) x

Application program: description and examples

SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION

Technische Daten: instabus EIB supply instabus line: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Product documentation

DIN RAIL 12/8/4 OUTPUT MODULE. BOxxB01KNX. Product Handbook

Product documentation

EIB/KNX ENO Radio bus interface (32-channel)

Use of the application program

R oom C ontroller K -B U S. U ser m anual-v er.2.1 AMRM-41/00.1. KNX/EIB Intelligent Installation Systems

Room controller LS 990 / LS plus Stainless Steel / Aluminium

Technical Manual MDT Universal Interfaces

Product documentation

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Product and functional description

Operation and installation manual KNX IP Multi IO 580 (48I/O) Application. 2. Factory default settings. 1. Installation and connection ❹ ❼ ❻ ❷

instabus EIB System Actuator

Technical Manual MDT LED Controller

Use of the application program. Contents overview. GAMMA instabus Application program description. August 2012

Water-protected surface-mounted push-button bus coupler Order No , , ,

Application description for the KNX Roombox. (Art. no. ORBK8L0S4HW/ORBK8D0S4HW/ORBK4L4S4HW/ORBK4D4S4HW)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Weather station GPS AP 257/61 Weather station AP 257/51

KNX S4-B10 230V. Multifunctional Actuator. Installation and Adjustment

Technical Manual. KNX/DALI ACTUATOR 1x8 channels Art /70100

ABB i-bus KNX Room Master RM/S 3.1 Product Manual

Application program usage. Functional description

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

KNX S-B2-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Weather station AP 257/51

Product documentation. KNX Blind Act.FM w.3 Inputs Art.-No. MTN

KNX S-B4T-UP. Actuator for 230 V or 24 V. Installation and Adjustment

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and functional description

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

ABB i-bus EIB Parameterisation software PZM 1 for application unit AB/S 1.1

KNX Gateway RGK02E Operating Instruction

GAMMA instabus Application Program Description. November CO Touch-Panel

Technical Documentation Intensity

Binary Input Module 2, 4 or 6 Channels. Product Manual 2017 INTERRA

Verwendung des Applikationsprogramms. 1. Function overview. GAMMA instabus Application program description. September 2010

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

1 Gang STD, 2 Gang STD, 3 Gang STD

MTN MTN

Software-Information. Binary 8f 23021/1.3b, Binary 8f 2021/1.3b. Software-Information to: Binary 4f 23021/1.3b, Binary 4f 2021/1.

Content 1 Generally Installation...3

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Four-channel Venetian blind actuator 230 V Installation Instructions

GAMMA instabus Application Program Description. July CO Colour Touch-Panel

Transcription:

Use of the application program Product family: Product type: Manufacturer: Input Binary input, 4-fold Siemens Name: Push button interface UP 220/03 Order no.: 5WG1 220-2AB03 Name: Push button interface UP 220/13 Order no.: 5WG1 220-2AB13 Functional description With this application program, it is possible to use conventional push buttons via the push button interfaces UP 220/03 and UP 220/13 for switching, dimming and shutter control functions as well as for sending values and storing and retrieving scenes. Two of the four inputs / two inputs can be combined functionally to create a 2-fold switch sensor. With push button pair A/B for example, it is possible to switch on and off via a short push button action as well as dim brighter and darker via a longer operation. Push button pair C/D for example generates telegrams for the shutter function up/down after a long push button action while a short push button action generates the stop command or louvre adjustment. The following functions are available for a push button pair: Switch, push buttons, value sending, scene Dimming on/off Dimming toggle/toggle Shutter up/down The dimming function is implemented with a stop telegram. In the dimming setting, a dimming telegram for 100% brighter or darker is generated with a long push button action while a stop telegram is sent when the push button is released. In the switch setting (ON/OFF/TOGGLE), there is no evaluation of the duration of the push button action. A switching telegram is sent immediately after operation. Maximum number of group addresses: 12 Maximum number of associations: 12 Note The view of the objects can be arranged individually i.e. this view can vary. All objects that correspond with a user operation have to be assigned to a group address. 1. 1.1. General Number of Inputs (depending of type) /B /B and C/D please select It can be set in this parameter whether a 2-fold or 4-fold push button interface is used. When retrieving the device from the database using the order number, the correct setting is carried out automatically. If this parameter is modified at a later date, the assignments of the group addresses are lost. Debounce time 10 milliseconds 30 milliseconds 50 milliseconds 100 milliseconds A temporary contact bounce is created when a push button is pressed. The contact opens and closes several times until it finally remains closed. The duration of the contact bounce is dependent on the push button used. The multiple operation of the push button would be detected by the rapid scanning of an input via the application software and therefore several switching telegrams are sent. This is prevented by the debounce time since after the initial detection of a change in the status, there is a delay for the set period and then the current status is used for further processing. Siemens AG 220710, 6 pages Technical manual Electrical Installation Technology Siemens AG 2007 Update: http://www.siemens.de/gamma 3.6.1.4.1/1

Type of contact channel A/B Type of contact channel C/D normally open/n.o. contact normally closed/n.c. contact normally open/n.c. contact normally closed/n.o. contact normally open/n.o. contact normally closed/n.c. contact normally open/n.c. contact normally closed/n.o. contact The contact type of the inputs connected to the push buttons is set here. The contact type can be set separately for each contact. normally open contact : The contacts of the push buttons are closed when they are operated and open when they are not operated. normally closed contact : The contacts of the push buttons are open when they are operated and closed when they are not operated. 1.2. of input A/B: The following parameters are also available for the inputs C/D for the push button interface UP 220/13. 1.2.1. : Switch, push buttons, value sending, scene This parameter defines the precise function of channel A: Switch (rising edge) : A signal is only triggered on rising edge (if the contact changes from 0 /open to 1 /closed). Switch (short/long push button action) : In this case, it is possible after a short push button action to send a different value than for a long push button action or to send the same values to a communication object. Switch (rising and falling edge) : It is possible to send different values or the same values to a communication object on rising edge (if the contact changes from 0 /open to 1 /closed) and on falling edge (if the contact changes from 1 /closed to 0 /open). Value sending (rising edge) : Only one value (8-bit) is sent to the communication object on rising edge (if the contact changes from 0 /open to 1 /closed). Value sending (rising and falling edge) : It is possible to send different values or the same values (8-bit) to a communication object on rising edge (if the contact changes from 0 /open to 1 /closed) and on falling edge (if the contact changes from 1 /closed to 0 /open). Value sending (short/long push button action) : In this case, it is possible after a short push button action to send a different value than for a long push button action or to send the same values (8-bit) to a communication object. Scene : In this setting, an 8-bit scene can be retrieved or stored in actuators. Function of input A/B Switch, push buttons, send value, scene Dimming On/ Dimming toggle/toggle Shutter Up/Down The required function can be set with this parameter. In the setting Switch, push buttons, send value, scene, inputs A and B can be assigned the functions separately. In the dimming and shutter control functions, the inputs are permanently assigned to a push button pair and are evaluated together. Switch (rising edge) Switch (rising and falling edge) Switch (short/long push button action) Send value (rising edge) Send value (rising and falling edge) Send value (short/long push button action) Scene Technical manual 220710, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2007 Electrical Installation Technology 3.6.1.4.1/2

1.2.1.1. : Switch (rising edge): n On / Switch, 1 Bit CRTU The switching telegrams are sent via the group address which n On/ /Toggle Switch, 1 Bit CRWT The switching telegrams are sent via the group address which Value on rising edge Value on falling edge On Toggle On Toggle 1.2.1.3. : Switch (short/long push button action): Value On Toggle This parameter sets the value which is sent when an event is triggered on the instabus KNX EIB. 1.2.1.2. : Switch (rising and falling edge): n On/ Switch, 1 Bit CRWT The switching telegrams are sent via the group address which Siemens AG 220710, 6 pages Technical manual Electrical Installation Technology Siemens AG 2007 Update: http://www.siemens.de/gamma 3.6.1.4.1/3

Value on short push button On action Value on long push button On action Long push button action 0.3; 0.4; 0.5; 0.6; 0.8; 1.0; min. This parameter defines the time limit for a short/long closing of the contacts. If a contact remains closed for longer than the set period, the software detects a long push button action. 1.2.1.4. : Value sending (rising edge): 1.2.1.5. : Value sending (rising and falling edge): n 8-bit value Value, The parameterised 8-bit integer value (EIS 6) is sent via the group address which n 8-bit value Value, The parameterised 8-bit integer value (EIS 6) is sent via the group address which Value on rising edge 0-255 (0 255) Value on falling edge 0-255 (0 255) 1.2.1.6. : Value sending (short/long push button action): Value (0-255) 0-255 This parameter sets the value which is sent when an event is triggered on the instabus KNX EIB. Technical manual 220710, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2007 Electrical Installation Technology 3.6.1.4.1/4

n 8-bit value Value, The parameterised 8-bit integer value (EIS 6) is sent via the group address which Value on short push button 0-255 action (0 255) Value on long push button 0-255 action (0 255) Long push button action 0.3; 0.4; 0.5; 0.6; 0.8; 1.0; min. This parameter defines the time limit for a short/long closing of the contact. If a contact remains closed for longer than the set period, the software detects a long push button action. 1.2.1.7. : Scene 8-bit scene control With the function 8-bit scene control, the user can reprogram scene modules for 8-bit scene control or actuators with integrated 8-bit scene control scene himself without modifying the project design with ETS i.e. he can assign current brightness values or switching states to the respective scene. The scene with the parameterised number (1...64) can be retrieved with a push button and stored via a long push button action. Both the command for saving a scene and the command to retrieve a stored scene and the number of the required scene are transmitted via a single communication object. Before saving a scene, the relevant actuators with the available push buttons/sensors must be set to the required brightness values or switching states. The addressed scene modules or actuators with integrated scene control are requested through the receipt of a telegram to query the currently set brightness values and switching states of the actuators and to store them in the corresponding scene. So that the storing of the scene is not accidentally triggered by a slightly longer push button action, the operating time which leads to the storing of a scene can be set separately to an extra long period. It can also be parameterised whether the push button should only be used to retrieve a scene or whether it is also possible to trigger the storing of a scene via the push button. No special activities take place for this function on mains or bus voltage failure and recovery. n Recall/save Scene, The telegrams for retrieving and saving the scene with the parameterised number (1...64) are sent via the group address which Number of scene (1 64) 1-64 This parameter specifies which scene (1...64) should be saved or retrieved. Enable scene programming Yes No This parameter determines whether the scene can be saved via a long push button action (yes). Long push button action for scene min. 0.3; 0.4; 0.5; 0.6; 0.8; 1.0; This parameter indicates the operating time of the push button which is necessary to trigger the storing of a scene. Siemens AG 220710, 6 pages Technical manual Electrical Installation Technology Siemens AG 2007 Update: http://www.siemens.de/gamma 3.6.1.4.1/5

1.3. : Dimming/shutter Both channels A/B are required here. Dimming on/off n On/ Dimming on/off, /B The ON or OFF switching telegrams are sent via the group address which n Brighter/Darker Dimming on/off, /B 4 Bit CT The dimming telegrams are sent via the group address which Dimming toggle/toggle n Toggle Dimming on/off, /B The ON or OFF switching telegrams are sent via the group address which n Brighter/Darker Dimming on/off, /B 4 Bit CT The dimming telegrams are sent via the group address which Shutter up/down Function of input A/B Switch, push buttons, value sending, scene Dimming on/off Dimming toggle/toggle Shutter up/down The required function can be set with this parameter. In the setting Switch, push buttons, value sending, scene, inputs A and B can be assigned the functions separately. In the dimming and shutter control functions, the inputs are permanently assigned to a push button pair and are evaluated together. Dimming on/off : An ON signal can be sent with channel A after a short push button action while a dimming brighter signal can be sent after a long push button action. With channel B, an OFF signal can be sent after a short push button action while a dimming darker signal can be sent with a long push button action. Dimming toggle/toggle : An ON or OFF signal is sent to channel A or B after a short push button action. An ON signal is sent after the first push button action while an OFF signal is sent after a further push button action. It should be noted that if other sensors with different group addresses affect the same actuator including the push button interface, these group addresses are entered as listening addresses at the communication objects. Dimming brighter is carried out with channel A after a long push button action while dimming darker is carried out with channel B. Shutter up/down : A STOP or CLOSE LOUVRE command is sent with channel A after a short push button action while a DOWN command for the shutters is sent after a long push button action. A STOP or CLOSE LOUVRE command is issued with channel B after a short push button action while an UP command for the shutters is sent after a long push button action. Long push button action from 0.3; 0.4; 0.5; 0.6; 0.8; 1.0; This parameter defines the time limit for a short/long closing of the contacts. If a contact remains closed for longer than the set period, the software detects a long push button action. n Open/closed Louvres, /B The commands STOP or Louvres OPEN/CLOSED are sent via the group address which A short push button action always generates a command to stop the movement or to adjust the louvres by a step. n Up/down Shutter, /B The commands for movement UP/DOWN or for lowering/raising the blind/shutter are sent via the group address which Technical manual 220710, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2007 Electrical Installation Technology 3.6.1.4.1/6