WTDIO-M. e e d e r. Digital I/O Module. Technologies FEATURES. Price $59 SPECIFICATIONS DESCRIPTION. Weeder Technologies

Similar documents
WTDIO-M. eeder. Digital I/O Module. Technologies FEATURES SPECIFICATIONS DESCRIPTION. Weeder Technologies

Weeder Technologies. 90-A Beal Pkwy NW, Fort Walton Beach, FL

Weeder Technologies. 90-A Beal Pkwy NW, Fort Walton Beach, FL

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

USB1. Encoder Data Acquisition USB Device Page 1 of 6. Description. Features

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

ICP PANEL-TEC PEX3000 II

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

EWAVE Inc Gracefield Ln. Dallas, Texas (972)

Serial Communication Prof. James L. Frankel Harvard University. Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved.

Bolt 18F2550 System Hardware Manual

LK Technical Manual. Revision: 2.0

ADR7700. RS232 / Data Acquisition Interface USER MANUAL V 1.0

Instruction Manual for BE-SP3 Circuit. 10/21/07

Rapid28iXL PIC Prototyping PCB User Manual

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6

OPERATING MANUAL AND TECHNICAL REFERENCE

Rapid40iXL PIC Prototyping PCB User Manual

Manual 601: : USB/RS232. Specifications. Contents. Options

Blue Point Engineering

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

Flex Series User Guide

Suprex RS-485 SPX-7500 Wired Reader-Extender

Getting started with your DGH module:

Home Security System with Remote Home Automation Control

MIDI CPU Hardware Rev K. User Manual

CMM 900-3W USER GUIDE

Select a Data Communication Interface

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

Universal RFID Socket board with USB interface

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

RTU560 Connections and Settings DIN Rail RTU 560CIG10

PCI Host Controller 14a Hardware Reference Release 1.2 (October 16, 2017)

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

MX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00

NORITAKE ITRON VFD MODULES GU128x18F-K612A2

ISA Host Controller 15a Hardware Reference Release 1.2 (October 16, 2017)

EGW1-IA3-MB User s Manual

TinyTrak4 v7 Hardware Manual

Serial Interface Module

SC1602LC 16x2 Large Characters RS232 LCD Module. User s Manual. Large Viewing Area 99mm x 24mm. Large Character Size. 4.84mm x 9.66mm.

School of Computer Science Faculty of Engineering and Computer Science Student ID Number. Lab Cover Page. Lab Date and Time:

Mounting the Model 2601

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

HC-8+ IO Expander Version 1.0

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

MicroBolt. Microcomputer/Controller Featuring the Philips LPC2106 FEATURES

DSP240-LPI Inverter Controller Card. Technical Brief

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Overview. The DIN-RS232 has three primary functions: Isolated parallel RS-232 interface Fused power distribution Animatics peripheral expansion bus

Universal RFID Socket board with RS232 / USB interface

8520/8520R. User Manual

CONNECTING YOUR PC TO THE USB EVALUATION BOARD

[WIR-1286]868MHz LORA Wireless Module. Page 1. LORA 868MHz Wireless serial link [WIR-1286]

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

4.3 Digital Communication

SPX-7400_SPX-7410_MAN_161028

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

IO64 User's Manual. Rev C. Document

Installation & Operation Guide

Automationdirect.com. D i r e c t L o g i c M O D B U S S L A V E F 4 S L V - M B

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Troubleshooting Guide

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

AB300-Series Automated Filter Wheels

ONYX-MM-XT PC/104 Format Counter/Timer & Digital I/O Module

180 Series Keypad. Handbook. Revision 2.1

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

MegaAVR-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

DATA CONNECT ENTERPRISE

Intelligent Devices IDI 1100 Series Technical Manual

SIXTEEN UNIVERSE CONTROLLER

Ocean Controls KTA-224 Modbus IO Module

WIR-1386 / WIR-1186M Long Range 865MHz 867MHz RF Wireless Module with WIR-METERING Mesh Stack

With a digital input we can read two states, a high or low. A switch can be open or closed.

ARDUINO LEONARDO WITH HEADERS Code: A000057

Quick Start Guide. ZR1x/ZR2x. Wireless Single / Dual Relay Controllers. Copyright 2012 National Control Devices. All Rights Reserved.

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

NORITAKE ITRON VFD MODULES GU128x18F-K610A2

Quick Start Installation Guide

EMS467 Monitoring System. Installation and Operations Manual Section 40

EtherSeries Modbus Gateway EMB-2 User s Guide

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

Digital Keypad Introduction

C10S- PARALLEL PORT INTERFACE CARD Rev. 1.4

BTH-1208LS Wireless Multifunction DAQ Device

DX-10 tm Digital Interface User s Guide

HAND HELD PROGRAMMER QUICK START GUIDE

Modtronix Engineering Modular Electronic Solutions SBC28DC. Single board computer for 28 pin DIP PICs

EASY219 / IEC CANopen Master / Slave

RS485 MODBUS Module 8I8O

T1K MODBUS Base Controller Specifications

BV4542. I2C or Serial 16x2 with Keypad interface

11 Serial Communications

Transcription:

e e d e r Technologies 90-A Beal Pkwy NW, Fort Walton Beach, FL 32548 www.weedtech.com Voice/Fax 850-863-5723 Digital I/O Module FEATURES 14 I/O channels; individually configured for input or output. All inputs incorporate a pull-up resistor to 5-volts, simplifying hookup to switch contacts. DIP switch addressable; stack up to 32 modules on the same port for 448 I/O points. Outputs can sink/source up to 25 ma each. Responds to button presses and switch transitions using automatic debounce and typematic repeat with adjustable delay. Decodes 4x4 matrix keypad using autodebounce and typematic repeat. Turns on/off relays, triacs, switching transistors, etc. One-shot pulse output with software programmable length of 10 to 655,350 µs. Industry standard RS-232 interface. Meets all EIA/TIA-232E and V.28 specifications. Wide power supply range (8 to 30 VDC). Screw-terminal connectors used on all inputs and outputs. DESCRIPTION Connects to the RS-232 serial port of a PC, laptop, or other host. Enables software programs to interact with the hardware of a mechanical world via 14 distinct digital-logic input/output channels. Uses include industrial automation, process control, alarm/security, home automation, remote data entry/retrieval, keypad access systems, etc. Easy to use command set minimizes user learning curve but preserves a robust, feature rich, functional environment. Ideal for quick set-up and run applications. SPECIFICATIONS Digital Inputs Buffer Type Digital Outputs Output Current Processor Clock Up to 14, accepting 5V logic signals 7 use Schmitt Trigger, 7 use TTL Up to 14, generating 5V logic signals 25 ma max per chn. 90 ma total source 200 ma total sink PIC16C62B 4 MHz Communications 9600 Baud, N, 8, 1 Power Requirements Current Draw Operating Temperature +8 to +30 VDC 13 to 26 ma, plus any output drive current -20 C to +80 C Board Dimensions 3.1" x 2.0" x 0.7" Weight 1.8 oz Price $59 Page 1

TABLE 1: ADDRESS SETTING HEADER CHARACTER ASCII (HEX) DIP SWITCH SETTING 1=on, 0=off 1 2 3 4 5 A (41) 0 0 0 0 0 B (42) 0 0 0 0 1 C (43) 0 0 0 1 0 D (44) 0 0 0 1 1 E (45) 0 0 1 0 0 F (46) 0 0 1 0 1 G (47) 0 0 1 1 0 H (48) 0 0 1 1 1 I (49) 0 1 0 0 0 J (4A) 0 1 0 0 1 K (4B) 0 1 0 1 0 L (4C) 0 1 0 1 1 M (4D) 0 1 1 0 0 N (4E) 0 1 1 0 1 O (4F) 0 1 1 1 0 P (50) 0 1 1 1 1 a (61) 1 0 0 0 0 b (62) 1 0 0 0 1 c (63) 1 0 0 1 0 d (64) 1 0 0 1 1 e (65) 1 0 1 0 0 f (66) 1 0 1 0 1 g (67) 1 0 1 1 0 h (68) 1 0 1 1 1 i (69) 1 1 0 0 0 j (6A) 1 1 0 0 1 k (6B) 1 1 0 1 0 l (6C) 1 1 0 1 1 m (6D) 1 1 1 0 0 n (6E) 1 1 1 0 1 o (6F) 1 1 1 1 0 p (70) 1 1 1 1 1 STACKABLE DATA MODULES All modules in this series incorporate two EIA/TIA-232E serial ports which communicate at 9600 baud, no parity, 8 data bits and 1 stop bit. DB9 connectors are jumpered to satisfy hardware handshaking. The port labeled HOST is configured as a DCE device and should be connected to a PC s serial port. The port labeled SLAVE is a DTE device and can be left open, or connected to another module s host port. Up to 32 modules can be chained together in this fashion to form a network. Either plugged together end to end, or separated by a cable. Because a module contains two individual bi-directional ports which pass data through, it also acts as a repeater, extending the total allowable length of the RS-232 communications line. A modem can serve as the host for remote operation, but since a modem uses a DCE port, a null modem adapter must be placed between the modem and the data module s host port. A gender changer may also be required. In addition, any hardware/software flow control must be disabled in the terminal program. Each module in a network should be set to a different address using the on-board 32-position DIP switch. A module will only respond to data packets that begin with its own unique header character, which is determined by this DIP switch setting. See Table 1. Data packets transmitted by a module will also begin with this header character. The host PC can use the header character to address each individual module in a network, and to identify a module which is talking. COLLISION CONTENTION The utilization of the communications line can be thought of more as a single, bi-directional, data bus, operated in a multi-drop mode rather then a standard RS-232 data link. A transmission from a data module travels in both directions, upstream to the host, and downstream to signal other modules that it has seized the line. Before transmitting, a module will listen to the communications line and wait for quiescence. After a silent period equal to the length of one byte, the waiting module will send its data packet using a Carrier Sense Multiple Access with Collision Detection communications protocol. See the application note (AN100) at the back of this manual for more details. Page 2

COMMAND SET The host PC communicates with the Digital I/O Module using a command set comprised of standard ASCII character strings as depicted in Table 2. Each I/O channel will be configured as either an input or output depending on the need of the particular function evoked by the reception of a command string. A detailed description of each command and configuration follows. HIGH/LOW - Changes the specified I/O channel to an output, if not already, and sets it to the desired logic state. The I/O channel can be TABLE 2: COMMAND SET instructed to remain at this new state, or simulate a one-shot multivibrator and return to the original state after a user defined time-out period in the range of 10 to 655,350 µs. Note, the value assigned to the time variable is multiplied by 10 when loaded. BUTTON - Configures the specified I/O channel to sense and respond to a low-going transition such as the press of a normally-open button wired to ground. A built-in debounce feature is used to mask multiple transitions produced by contact bounce. The response character string will be retransmitted at a rate determined by TYPEMATIC while the button is held down. TITLE COMMAND DESCRIPTION HIGH H chn time Make channel chn an output and set high for time x10 microseconds. chn = A-N, time = 1 to 65535. If time omitted, chn remains high.(note 3) LOW BUTTON SWITCH MATRIX READ WRITE INPUT TYPEMATIC ECHO L chn time B chn S chn M R chn W data I chn T chn time X value Make channel chn an output and set it low for time x10 microseconds. chn = A-N, time = 1 to 65535. If time omitted, chn remains low. (Note 3) Make channel chn an input and respond to button press. Returns "chn L" when pressed. Repeated if held down. chn = A-N. (Note 3) Make channel chn an input and respond to switch transition. Returns "chn L" or "chn H" when toggled. chn = A-N. (Note 3) Use channels G-J as outputs and channels K-N as inputs to decode a 4x4 matrix keypad. Returns "M row col ". row = G-J, col = K-N. (Note 3) If chn = A-N, read state. Returns "chn H" or "chn L". If chn = P, read channels A-H as an 8-bit parallel port (A = LSB). Returns 00 to FF. If chn omitted, read all channels as parallel port. Returns 0000 to 3FFF. Make required number of channels an output (see text), and writes data to them as a parallel port. data = 0 to 3FFF. (A = LSB) (Note 3) If chn = A-N, make channel chn an input. If chn = P, make 8-bit port channels (A-H) an input. If chn omitted, make all an input. (Note 3) Sets the typematic repeat delay for a specific input channel which will be used for BUTTON or MATRIX functions. chn = A-N, time = 1 to 15 listed in 1/10 of a second. Default = 3 (0.3 sec). If time = 0, typematic repeat disabled. If time omitted, reads the current setting. (Note 3) Turns on or off the reception confirmation echo. Value = 0 or 1. 0 = off, 1 = on, default = 1. If value omitted, reads the current setting. ERROR? This character will be returned after an invalid command or variable. RESET! This character will be returned after a power-on reset, or brownout. Note 1: All command strings sent to the data module should be preceded with the header character (see Table 1), and terminated with a carriage return. All responses from the data module will also appear in this format. Note 2: Any spaces shown above in the listing of the command strings are for clarity only. They should not be included in the actual transmission from the host, nor expected in a response from the data module. Note 3: If ECHO is on, after successful execution this command will be echoed back to the host in the same format as received. Page 3

TABLE 3: TERMINAL / CONNECTOR DESCRIPTION NAME TYPE ELECTRICAL SPECS COMMENTS: HOST DB9 (female) EIA/TIA-232E Standard RS-232 serial port configured as DCE. Connects to host PC. Hardware handshake jumpered. SLAVE DB9 (male) EIA/TIA-232E Standard RS-232 serial port configured as DTE. Can be connected to another data module's HOST port for networking. Power Source Jumper N/A Power source selection jumper. Selects either external, or port powered. (Note 1) + Screw Term +8 to +30 VDC External unregulated power supply input. - Screw Term GND External power supply ground. A N Input Screw Term VIL = 0 to 0.8V TTL, 0 to 1.0V ST VIH = 2.0 to 5V TTL, 4.0 to 5V ST Max = -0.3 to 5.3V (Note 2) If configured as input, will decode logic levels. All channels incorporate a pull-up resistor to 5 volts which will hold it high if left open. A-G = Schmitt Trigger, H-N = TTL. A N Output Screw Term VOL = 0 to 0.6V VOH = 4.3 to 5V Sink/Source 25mA (Note 3) If configured as output, will change logic state upon command. +5 Screw Term +5V @ < 100 ma Regulated 5 volt output. GND Screw Term GND Logic ground. Note 1: Selecting "port powered" will draw from the power supply source of an upstream data module. Caution, the COM port of a PC or laptop does not supply enough current to serve as the power supply source. Note 2: Due to internal 20 ma clamping diodes, a series input resistor will increase the maximum allowable input voltage. Note 3: Each I/O channel can individually sink or source 25 ma. Maximum current sunk by all output channels combined should not exceed 200 ma. Maximum current sourced by all output channels combined should not exceed 90 ma. SWITCH - Configures the specified I/O channel to sense and respond to a logic transition. This can be an SPST toggle switch wired to ground. A built-in debounce feature is used to mask multiple transitions produced by contact bounce. This configuration differs from BUTTON in that it reports both low to high, and high to low transitions, and does not incorporate the typematic repeat function. MATRIX - Configures the last eight I/O channels to be used to automatically scan and decode a 4x4 matrix keypad. To hookup to a keypad, connect channels G-J to the keypad s "row" contacts, and channels K-N to the keypad s "col" contacts. When a button is pressed, the "row" and "col" channels which make contact are reported to the host. A built-in debounce feature is used to mask multiple transitions produced by contact bounce. The response character string will be retransmitted at the rate determined by TYPEMATIC while a button is held down. READ - Reads the logic state of a specified I/O channel, or reads multiple channels as a parallel port in hexadecimal notation. Note, this command will not change the direction (input or output) of a channel, therefore it can be used to check the current state of an output as well as read an input. WRITE - Writes data to the I/O channels as a 4, 8, 12 or 14-bit parallel port. The data must be in hexadecimal notation from 0 to 3FFF. The number of characters (nibbles) in the data field determines how many channels are changed to output and manipulated. For example, if data = F, channels A-D will be set high, all other channels will not be effected. In contrast, if data = 000F, channels A-D will be set high and channels E-N will be set low. INPUT - Sets the specified I/O channel, or multiple parallel port channels, to a high impedance state (input), and cancels any other Page 4

function (SWITCH, BUTTON or MATRIX) assigned to that I/O channel(s). The READ command can then be used to retrieve data from external logic sources. Note, this is the natural state of all I/O channels upon power-up, or after a power disruption or brown out. FIGURE 1: MODCOM APPLICATION TYPEMATIC - Sets the typematic repeat delay of a specific I/O channel which will be used when that channel is configured for BUTTON or MATRIX functions. ECHO Turns on or off the confirmation echo which is used to verify reception of a command. If reception confirmation is not needed, turning ECHO off will increase the repetitive rate at which the host can manipulate the I/O channels. ERROR - Any data string sent from the host containing the correct header character but an invalid command or variable will be responded to with this error indicator. RESET - Upon power-up or any other reset condition, this indicator is transmitted to the host. If a data module encounters an unintentional reset due to a power disruption or brown-out, all configuration info will be lost. Therefore, upon reception of this indicator, the host should retransmit any configuration information originally sent at the start of the operating program. OPERATION To hook the data module to a host PC, use a standard RS-232 cable with male and female DB9 connectors on opposite ends. This cable should be wired straight through (pin to pin) with no crossover of the data lines. In other words, not a null modem cable. Connect a suitable DC power source to the + and - terminals of the data module. This power source can be a simple wall mounted AC adapter or wall-wart, however, avoid adapters which were originally intended to charge a cordless device since most of these do not provide filtering. The high noise content will wreck havoc on a microcontroller based circuit. When the data module is first powered up, the red LED will flash briefly. This indicates that the on-board microcontroller has booted up, successfully completed it's internal diagnostic test, and has transmitted the reset character to the host to signal that it is up and running. The red LED will also flash anytime the module receives or transmits any data packet, thus making it a valuable diagnostic tool when troubleshooting communications problems. An easy-to-use Windows software package called "ModCom" is available and can be downloaded from Weeder Technologies' web site. This program will allow the user to quickly set up custom buttons which transmit commands, custom windows that poll for data, and a variety of other screen objects such as slider controls, event counters & timers, bar-graph level indicators, button selection arrays, and more. In addition, conditional statements can be set up to take action when specific events or conditions are met, sequences can be written and then called by other screen objects during run-time, and data can be logged to a file automatically at user-defined intervals. Once ModCom is installed and running, go to the <Communicate> menu item at the top of the screen and click on <Send/Receive>. A dialog box will pop up which you can use to type in the commands from Table 2, transmit them directly to the data module, and see the response coming back. Use this dialog box to familiarize yourself with the command set and to experiment with the various features supported by the module. The experience gained here is significant since these are the same command strings you will use when setting up the other objects in ModCom. To operate the Digital I/O Module, start with the sample application "WTDIO.mod" which can be found in the ModCom subfolder called "Samples". After this file is opened, it will appear as shown in Figure 1. To start the main run-loop, click on the green toolbar button at the top of the screen. At this time, ModCom will transmit a series of initialization commands, found in the <Run-Loop><Initialization> menu item, to the WTDIO module to set up it's I/O channels for the Page 5

various functions shown on the screen. You can then use the mouse to click on the Push Buttons and control the logic state of the channels which are setup for output, and hook up switches to those channels setup for input and experiment with their functions. To understand how this application works, first halt the run-loop by clicking on the red toolbar button at the top of the screen, then right-click on any screen object to pull up it's properties dialog box. In this box you will be able to view the commands which the Push Buttons use to control the output channels, or view the input strings which the Event Counters and Event Timers watch for to control their operation. Channels G and H use conditional statements to detect a switch transition and send the appropriate message to their windows. To view or edit these conditional statements, go to the <Run-Loop> menu item at the top of the screen and click on <Conditionals>. Refer to the help files for more information. CONTACT DEBOUNCE A typical switch or button uses metal plates (called contacts) which can be moved together or apart in order to make or break the current path. During switch closure, when these plates first make contact with each other they will bounce several times before coming to rest. This bouncing of the contacts will appear as multiple transitions to a digital system, and in most cases, not be desirable. Each I/O channel of the incorporates its own debounce timer used to mask these multiple transitions by disabling the input for a short period of time after each logic state change. When an I/O channel detects a change of state, the action is immediately reported to the host, it's debounce counter is loaded with a time value equal to 100 ms, and the input is disabled until this time period has lapsed. Because each I/O channel's timer operates independently of each other, the can still report actions on additional inputs while it's waiting for one or more debounce timers to expire. TYPEMATIC REPEAT In addition to the debounce timers mentioned above, each I/O channel has it's own typematic repeat timer which operates both independently of each other, and independent of it's own debounce timer. The later being important in order to allow the to respond to multiple switch closures on a single I/O channel even though the typematic repeat delay for that particular channel may be set to a much slower rate. To set the typematic repeat delay of the buttons on a matrix keypad, work with the I/O channels which are setup for input (K-N). These channels correspond to the four columns of the keypad and may be set to different values if wishing to have certain button columns repeat at a different rate then others. USING BUTTONS & SWITCHES To hook the to a button or switch, simply run a wire from one contact of the switch to the desired I/O channel's screw terminal, and a wire from the opposite contact to the screw terminal labeled GND. A 10KΩ pull-up resistor is already included on the board for each I/O channel so no additional components are required. The logic level at the I/O channel will be high when the switch is open, and low when the switch is closed. DRIVING RELAYS The I/O channels of the can sink or source only 25 ma. This current is insufficient to drive most relays therefore a switching transistor must be used as shown in Figure 2. The voltage applied to V+ should be that which is necessary to drive the relay and can be the same power source which is connected to the data module, or a completely separate supply as long as the ground terminals of the two supplies are tied together. Caution! DO NOT use the +5 volt output of the as your relay power source. FIGURE 2: HOOKING UP TO RELAYS To I/O Channel 1K 2N2222 or equivalent Relay coil 1N4001 V+ Page 6

Address Setting This DIP switch sets the address of the Data Module and determines the header character of it's data packets. Trans/Rec Indicator LED Flashes whenever there is communications between host PC and Data Module. RS-232 Slave Port Connects to the Host port of another Data Module. SLAVE HOST RS-232 Host Port Connects to the serial port of the host PC. A B C D E F G H I J K L M N +5 GND Power Source Jumper Draw power from external input terminals, or from an upstream Data Module via the host port. Power Supply Inputs Will accept any voltage between 8 and 30 VDC. Digital I/O Channels TTL level inputs and outputs which can be individually configured. Holes will accept size 440 screws 0.5" 1.0" 2.0" 0.5" 0.375" 2.35" 0.375" 3.1" Page 7

Page 8