Safety switches with separate actuator

Similar documents
Safety switches with separate actuator

Safety switches with separate actuator

Safety switches for hinged doors

Safety switches with manual mechanical delay and separate actuator

Position switches FD series

Position switches FD series

Safety switches with solenoid and separate actuator

Safety switches with manual mechanical delay and separate actuator

Microswitches MS Series

Hinged safety switches, Palladio line

Single contact blocks

Safety coded magnetic sensor SR B series

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Safety coded magnetic sensor SR A series

Safety coded magnetic sensor SR B series

Safety hinge switches HX series

SR B series coded magnetic safety sensors

Safety coded magnetic sensor SR A series

SR A series coded magnetic safety sensor

Coded magnetic safety sensor SR B series

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Hinged-shaped safety switches in stainless steel, HX series

HP-HC series safety hinge switches

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet - AZ 15 ZVRK

Datasheet - ZR Z

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

SAFETY SWITCHES. Phone: Fax: Web: S20 Safety Switch

LED unit. Selection diagram LED COLOUR white LED red LED green LED blue LED orange LED INDICATION MODE CONNECTIONS MOUNTING TYPE

Datasheet - ZS Z

Safety hinge switches HP-HC series

Safety hinge switches HX series

Datasheet - AZ 16-02ZVK

OsiSwitch Limit Switches Innovation through modularity

General Catalogue Safety

Datasheet - AZ 15 ZVK

52 x 72 x 30 (2.05 x 2.83 x 1.18) N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Datasheet - AZ 16ZVRK

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Datasheet - AZ 16-03ZVRK

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

VF CNM5MM-L100. Accessories. M12 male connectors. Code structure. M 12x1

Datasheet - BNS ZG-ST

SAFETY LOCKING DEVICES

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

Datasheet - AZ 16-02ZVRK-ST

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

S20. Safety Switches. Phone: Fax: Web: -

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

Datasheet - ZR Z

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

Tongue Switches Trojan 5 & 6

Safety Switches with Separate Actuator, Metal Housing

GENERAL TECHNICAL DATA Specifications, Directives and Standards

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

S200 Safety Switches SAFE IMPLEMENTATION AND OPERATION. Original operating instructions. make technical changes. We reserve the right to

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

SIRIUS 3SE5, 3SE2 Mechanical Safety Switches Mechanical Safety

SAFETY COMMAND DEVICES

Position Switches Series 8070

S300. Safety Switches. - Fax: Web: - make technical changes. We reserve the right to

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

Safety Systems Safety Integrated

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

Order/Technical Support Tel: (800) / FAX: (800) /

ZB5FG09 flush mounted selector switch head key pos stay put

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Conveyor Belt Alignment Switches from IDEM

SERIES SUBMINIATURE SNAP-ACTION SWITCHES

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

SERIES AZ15/16. Tamper-Resistant Movable Machine Guard Safety Interlock Switch. Features & Benefits. Description. Operation. Typical Applications

Datasheet - RSS 36-D-R-ST

Limit switches 3. with solenoid interlocking. Metal, type XCSE and XCSL. Page 6/284. Page 6/296

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

Datasheet - SRB 402EM-24V

Datasheet - SRB 301LC/B-24V

Limit switches OsiSense XC Special

Inductive sensor BI1.5-EG08-Y1-H1341

Safety and limit switches

83132 / / Subminiature Double Break Switches... 3/ Subminiature Switches... 3/ Sealed Subminiature Switches...

Universal Tongue-Operated Safety Interlock Switch

series Subminiature snap-action switches

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

JULIET-PK. Joystick station

Inductive sensor BI1.5-EG08-Y1-H1341

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor BI5-EM18-Y1X-H1141

Online data sheet. i15-mm0123 Lock i15 Lock SAFETY LOCKING DEVICES

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Transcription:

4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled With M1 plastic connector assembled and wired With M1 metal connector assembled and wired page 4/ General Catalog 00-008

Safety switches with separate actuator 4 Code structure Housing FR polymer housing, one conduit entry FX polymer housing, two conduit entries FW polymer housing, three conduit entries Contact blocks, snap action 6,, overlapped, 0 1NO+, 1 NC, NO+1NC,, 4, Head type detachable head (only for FW housing) Actuators without actuator (standard) D with straight actuator D1 with right-angled actuator D with jointed actuator D with adjustable jointed actuator in two directions D with long actuator D6 with right-angled long actuator D with adjustable jointed actuator in one direction D10 with shaped actuator Housing FK polymer housing, one conduit entry Contact blocks, 4, not detachable head (only for FR-FX-FK housing) Actuator extraction force 10 N (standard) E N Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options FR 6-ED1XGMK0 article Threaded conduit entry PG 1, (standard) (only for FR-FX housing) A PG 11 (only for FR-FX housing) M1 M M M16x1, M0x1, 1/ NPT (only for FR housing) Contacts type silver contacts (standard) G silver contacts gold plated 1 µm External metallic parts zinc-plated steel (standard) X stainless steel FK -ED1XGM1K Actuator extraction force 10 N (standard) E N Actuators without actuator (standard) D with straight actuator D1 with right-angled actuator D with jointed actuator D with jointed actuator adjustable in two directions D with long actuator D6 with right-angled long actuator D with jointed actuator adjustable in one direction D10 with shaped actuator options Preinstalled cable gland or connectors no cable gland or connector (standard) K1 with assembled cable gland suitable for Ø 6 to Ø 1 mm cables range K with M1 metal connector assembled and wired, 8 poles (only for contact blocks 0, 1, )...... For the complete list of all combinations, please contact our technical office. Threaded conduit entry PG 11 (standard) M1 M16x1, Contacts type silver contacts (standard) G silver contacts gold plated 1 µm External metallic parts zinc-plated steel (standard) X stainless steel Preinstalled cable gland no cable gland (standard) with assembled cable gland suitable K for Ø to Ø 10 mm cables range with assembled cable gland suitable K6 for Ø to Ø mm cables range General Catalog 00-008 page 4/10

4 Safety switches with separate actuator Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin and with double insulation FR and FK series one conduit entry FX series two conduit entries FW series three knock out conduit entries Protection degree: IP6 (electrical contacts) Patent pending Main data Housing polymer housing, from one to three conduit entries Protection degree IP6 contact blocks available 8 stainless steel actuators available M1 assembled connector versions Silver contacts gold plated versions Markings and quality marks: Approval IMQ: EG610 (FR-FX-FK series) Approval UL: E118 Approval CCC: 0001001 (FR-FX-FK series) Approval EZU: 101011 General data Ambient temperature: from - C to +80 C Version for operation in ambient temperature from - C to +80 C on request Max operating frequency: 600 operations cycles 1 /hour Mechanical endurance: 1 million of operations cycles 1 Max actuating speed: 0, m/s Min. actuating speed: 1 mm/s Actuator extraction force 10 N ( N -E version) (1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by IEC 4--1 standard. Cross section of the conductors (flexible copper wire) Contact blocks 0, 1,,, 4: min. 1 x 0,4 mm (1 x AWG ) max. x 1, mm ( x AWG 16) Contact blocks, 6,, : min. 1 x 0, mm (1 x AWG 0) max. x, mm ( x AWG 14) In conformity with standards: IEC 604--1, EN 604--1, IEC 6004-1, EN 6004-1, EN 1088, EN ISO 1100-1, EN ISO 1100-, IEC, EN 60, NFC 6-1, VDE 0660-00, VDE 011, CENELEC EN 001, BG-GS-ET-1. Approvals: IEC 604--1, UL 08, GB148.-001 In conformity with requirements requested by: Low Voltage Directive 006//EC, Machinery Directive 006/4/EC and Electromagnetic Compatibility 004/108/EC. Positive contact opening in conformity with standards: IEC 604--1, EN 604--1, VDE 0660-06. If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page 6/1 to page 6/8. Electrical data Utilization categories without connector Thermal current (Ith): 10 A Rated insulation voltage (Ui): 00 VAC 600 VDC 0 VAC for contact blocks 0, 1,,, 4 Protection against short circuits: fuse 10 A 00 V type am Pollution degree: Alternate current: AC1 (0...60 Hz) Ue (V) 0 0 00 Ie (A) 6 4 1 Direct current: DC1 Ue (V) 4 1 0 Ie (A) 6 1,1 0,4 with 4 poles M1 connector Thermal current (Ith): 4 A Rated insulation voltage (Ui): 0 VAC 0 VDC Protection against short circuits: fuse 4 A 00 V type gg Pollution degree: Alternate current: AC1 (0...60 Hz) Ue (V) 4 10 0 Ie (A) 4 4 4 Direct current: DC1 Ue (V) 4 1 0 Ie (A) 4 1,1 0,4 with 8 poles M1 connector Thermal current (Ith): A Rated insulation voltage (Ui): VAC 6 VDC Protection against short circuits: fuse A 00 V type gg Pollution degree: Alternate current: AC1 (0...60 Hz) Ue (V) 4 Ie (A) Direct current: DC1 Ue (V) 4 Ie (A) page 4/11 General Catalog 00-008

Safety switches with separate actuator 4 These safety switches are ideal to control gates, sliding doors and other guards protecting dangerous parts of machine. The stainless steel actuator is fastened to the moving part of the guard, so it is removed from the switch on every opening of the guard. The switch mechanism guarantees that removing the actuator forces the positive opening of the electrical contacts. Easy to install, these switches can be applied to any kind of protection (with hinge, sliding and removable ones). Besides, the possibility to actuate the switch only with its actuator guarantees that the machine can be restarted only when the guard has been closed. All products (except FW series) are equipped with a particular mechanical hooking that does not allow the separation of the head from the body during its positioning. Rotating heads Removing the two fastening screws, in all switches, the head can be rotated in 0 steps. Actuator regulation zone 0,... 4, mm This switch has a wide backlash of the actuator into the head (4 mm) for an easier installation. With closed door, check that the actuator doesn t knock straight against the head of the switch; it must be in the adjustment zone (0, 4, mm) Not detachable head The action head type is completely interchangeable and compatible with previous head type, but it has the advantage to be not detachable from the switch body even if it is always adjustable in 0 steps (Pizzato Elettrica patent). The new head is safer because it cannot be ruined during installation. The head fixing screws have been reduced to only two (instead of the previous four) and so the rotation operation will be quicker and cheaper. Versions with N actuator extraction force Versions with N actuator holding force instead of the standard 10 N are available. Installation examples Limits of utilization Do not use where dust and dirt may penetrate in any way into the head and deposit there, in particular where metal dust, concrete or chemicals are spread. Do not use where explosive or inflammable gas is present. Data type approved by IMQ, CCC and EZU Rated insulation voltage (Ui): 00 VAC 0 VAC for contact blocks 0, 1,,, 4 Thermal current (Ith): 10 A Protection against short circuits: fuse 10 A 00 V type am Protection degree: IP6 MV terminals (screw clamps) Pollution degree Utilization category: AC1 Operation voltage (Ue): 0 VAC (0 Hz) Operation current (Ie): A Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X Positive opening of contacts on contact block, 6,,, 0, 1,,, 4 In conformity with standards: EN604-1, EN 604--1 and subsequent modifications and completions, fundamental requirements of the Low Voltage Directive / EEC and subsequent modifications and completions. Data type approved by UL Utilization categories Q0 (6 VA, 1-0 VDC) A600 (0 VA, 10-600 VAC) Data of the housing type 1, 4X (indoor use only), 1, 1 In conformity with standard: UL 08 For all contact blocks use 60 or C copper (Cu) conductor and wire size No. 1-14 AWG. Terminal tightening torque of,1 Lb-In. Please contact our technical service for the list of type approved products. Please contact our technical service for the list of type approved products. General Catalog 00-008 page 4/1

4 Safety switches with separate actuator Dimensional drawings Contacts type: R = snap action L = LO = overlapped Contact blocks R 41. 1. FR polymer housing polymer housing polymer housing polymer housing 0.8 0 6. 4 4.x. 4. 14...8 86. 41. 4 FX 0 4 0 0 6. 4 18. 4.x.. 4. 14. 1. conduit entries thread M0x1, 18 0. 0.. FW -M 0 6.. 1.8.1.6 14.1 1.6 8 41. 6. 0.8 4 4.x. 4. 14..8 6 L FR 6 4.6 FX 6 4.6 4.6 FW 6-M 0 4.. 0 4.. 0 4.. LO FR FX FW -M 0 6.6.1 0 6.6.1 0 6.6.1 L FR FX FW -M 0 6. 0 6. 0 6. 0 L FR 0 1NO+ FX 0 1NO+ FW 0-M 1NO+ 1 L FR 1 NC FX 1 NC FW 1-M NC L FR NO+1NC FX NO+1NC FW -M NO+1NC L FR FX FW -M FK 4 L FR 4 FX 4 FW 4-M FK 4 Min. force 10 N (18 N ) 10 N (18 N ) 10 N (18 N ) 10 N (18 N ) All switches listed above are available in the version with N actuator extraction force. To obtain these products, the order code has to be changed adding the extension -E, for example FR 6-E. Min. force N version N (8 N ) N (8 N ) N (8 N ) N (8 N ) How to read travel diagrams Example diagram NC opening Max travel Closed contact 0 1-1-14 8 Open contact NO closing All measures in the diagrams are in mm IMPORTANT: NC contact has to be considered with inserted actuator. In safety applications it is necessary to activate the switch at least up to the positive opening point indicated in the diagrams with the symbol. Operate the switch at least with the positive opening force, indicated between brackets, below each article, next the value of minimum force. Positive opening travel Accessories See page /1 Items with code on the green background are available in stock All measures in the drawings are in mm page 4/1 General Catalog 00-008

Safety switches with separate actuator 4 Actuators stainless steel IMPORTANT: These actuators must be used with FR, FX, FK e FW (e.g. FR 6) VF KEYD Straight actuator VF KEYD1 Right-angled actuator 10 pcs packs 1 4 11. 8 1 4. 14. 4 6. 8 1 14. Ø 4. 6 VF KEYD Jointed actuator 0 16 R>0 11 1 4. R>0 4 4 R>0 The actuator can flex in four directions for applications where the door alignment is not precise VF KEYD Jointed actuator adjustable in one direction 6 16 10. VF KEYD Jointed actuator adjustable in two directions 0 1 1 4. 0 4 1 11 Actuator adjustable in two directions for doors with reduced dimensions. VF KEYD Long actuator VF KEYD6 Right-angled long actuator.6.4.6.1 8 1. 0.6 14.4 64 18.1.6 1 0.6 14.4 41.. 16 1.6.1 VF KEYD10 Shaped actuator 11 R>0.4 4 14.4 11 14 14..4 R>0 8.6. Actuator adjustable in one direction for doors with reduced dimensions. General Catalog 00-008 page 4/14