GSV-2MSD-DI DMS-Data Logger

Similar documents
Version: 16/12/2013. GSV-2MSD-DI Data Logger Instruction manual

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain Gage Measuring Amplifier GSV-3

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain Gage Measuring Amplifier GSV-1

GSV-1A4 M12/2 M12/2. Highlights

6-Channel measuring amplifier GSV-6BT

GSV-6BT GSV-6BT. Description

Multi-axis force-torque-sensor K6D27

GSV-3USBx2 3,5mV/V 4,2V

Revision B 9330 Operating Manual

MODEL 9250 Preliminary data sheet

SCP for Plastics Processing

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Hand-held thermometer Model CTH7000

digiclip Data sheet DF31DP Special features B en

digiclip Data sheet DF31CAN Special features B en

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DMX-K-DRV Integrated Step Motor Driver Manual

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Hand-held thermometer Model CTH7000

LAN-XI Front Panels UA-2100 to -2105, UA-2107 to -2114, UA-2116 to and UA-3100 to -3102; LAN-XI Array Front Panel UA-2145-D

E101 - Strain Gauge Transducer Display Module. Contents

Expansion Module HZS 541-1S

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Trend-1 Vibration Data Logger. User Manual

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

LGR-5325 Specifications

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Technical data. Your advantages

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

The SilverNugget is a servo controller/driver for NEMA 34 frame microstep motors.

IPM650 Intelligent Panel-Mount Display

6224 Ethernet-Based Strain Measurement Module

OPERATION MANUAL - DS-MOD-

KiTorq Stator. Torque. Torque Evaluation Unit (Stator) for a Torque Measuring Flange. Type 4541A...

F USB Charger Controller F Release Date: Dec., 2011 Version: V0.11P. Nov., 2011 Data Sheet

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

BP16 Backplane for MAL Amplifiers

Isolated Process Current Input with Loop Power 7B35

SLC Commercial and Industrial Secure Digital (SD/SDHC) Card

LE 2 C CABLE-FREE READ-HEAD LINEAR ENCODER

Relay Deck Datasheet

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

RE 2 52 ROTARY ENCODER

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LGR-5327 Specifications

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

Characteristics and functioning

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

^2UMAC-CPCIAccessory Cx Family

RE 2 37 ROTARY ENCODER

BSL Hardware Guide for MP35 and MP30-1 -

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

User Manual CTP64-Rotate

Characteristics and functioning

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

VGA Port Companion Circuit

Precision hand-held pressure indicator Model CPH6400

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Technical data. Your advantages

Operation Manual for Sensor Interface LCV-USB2

Technical data. General specifications. Indicators/operating means

DPM-3221 Digital DC Power Meter with data logging capability.

CANcheck. Installation Tester for CAN/CANopen Networks MANUAL ENGLISH

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6.

TECHNICAL NOTE. VS1000: Evaluation Kit EVBA_2.0. Contents. EVBA_2.0 is a plug and play Evaluation Kit for Colibrys VS1000 accelerometers line.

VersaMax IP I/O Module

SYSTEMS ELECTRONICS GROUP

Installation Instructions for: Channel Thermocouple Amplifier

Modular Connector System with High Power, Signal, Fibre-Optic, Coaxial Contacts and Pneumatic Valves

USB Charging Controller. Features. General Description. Applications. Order Information

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

Ethernet OptoLock EDL300T

Preface About this User's Guide... iv What you will learn from this user's guide... iv Conventions in this user's guide... iv

PCI-FPGA-1B User Guide

Absolute Encoders Multiturn

Applications: Power generator sets and control systems for industrial engine applications.

ACU6. Technical Reference Manual. Specifications Interfacing Dimensions. Document topics. ANSARI Controller Unit Type 6 technical reference manual

SY061 Portable Load Meter with IEEE TEDS capability User Instructions

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

Connecting a Cisco Input Module

Specifications minilab 1008

AbstractAVR. Ledbuddy controller. Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel:

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

SY021 Portable Load/Force Meter User instructions

RWT310/320 SERIES TRANSDUCER. PRODUCT DATA SHEET 0.5Nm to 10,000Nm

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

10/100 Application Note General PCB Design and Layout Guidelines AN111

Transcription:

GS-2MSD-DI DMS-Data Logger Description The GS-2MSD-DI is a measuring amplifier with integrated data logger, which is suitable as a hand-held device and for stationary use. Due to its compact size, the GS-2MSD-DI fits in every bag. Data logger with SD card slot USB interface For DMS quarter, half and full bridges 0...0, potentiometric sensor 24 bit resolution sensor configurations available Battery mode Real-time clock IP version optional The sensors are connected via -pin Sub-D connector. Force sensors, torque sensors, DMS, quarter bridges, half bridges and full bridges can be connected. The measuring amplifier has integrated bridge completition for 20 ohm, 30 ohm and 000 ohm strain gauges. Active sensors with 0...0 output signal and potentiometric distance sensors can also be connected. A version of the device with protection class IP is also available. The SD card slot and the USB interface are then sealed with an additional cover. The SUB-D sensor connection and the housing seals are then reinforced for this protection class. The measurement data is saved with time stamp. Different operating modes e.g. individual value request, permanent recording, triggering per control line, min./max. mode and other settings are possible. The measuring rate can be set up to 370. Recording on SD card is possible up to 000. Up to sensor configurations can be defined and retrieved, e.g. for switching a sensor or quickly setting the measurement conditions. Tel +49 (0)3302 720 0, Fax +49 (0)3302 720 9, info@me-systeme.de, www.me-systeme.de

Dimensions Terminal assignment Sensor terminal, Sub-D Screen 2 GNDA Ground analogue input 7 Tare Zero-setting input / Trigger input 9 UE Analogue input 0 UA Analogue output +US Positive bridge power supply -US Negative bridge power supply (GND) +UD Positive differential input -UD Negative differential input 3 +UF Positive sensor cable 2 -UF Negative sensor cable 4 HB Half Bridge selector QB20 3 QB30 4 QB000 Bridge Completition Resistor 20 ohm Additional quarter bridge 30 ohm Additional quarter bridge 000 ohm Pin 4 must be bridged with Pin to connect half and quarter bridges. Quarter bridge are connected in three-wire connection to Pin, Pin and QB (3 and/or or 4). 9 Table : Allocation Sub-D socket 2 Tel +49 (0)3302 720 0, Fax +49 (0)3302 720 9, info@me-systeme.de, www.me-systeme.de

Connection plan for DMS bridges Full bridge Half bridge Quarter bridge -pole Sub D -pole Sub-D -pole Sub-D R R 4 R 4 QB Shield Shield No bridge Bridge between 4 and Bridge between 4 and Table : Connection of full and/or half and quarter bridges to -pin Sub D socket The following are supplied as standard accessories: Switching power supply 00..240 /.7A -pin Sub-D mating connector USB cable Software CD Instruction manual Required accessories: SD memory card, Class 0 (recommended for recordings of 000) Tel +49 (0)3302 720 0, Fax +49 (0)3302 720 9, info@me-systeme.de, www.me-systeme.de 3

Technical data (in battery operation or UB = 2 DC in the nominal temperature range) Size alue Unit Accuracy class Analogue 0, Digital Inputs Measurement range 0,0 ± (JP on with sensor supply) ±2 or ±3. per software (JP on 2 with 2, sensor supply) m/ m/ Connectible full bridge 4 x 30 Bridge supply voltage 2, / Input impedance >20 (300pF) M Common mode rejection DC 00 Analogue input ) Input voltage range >20 >00 0 0 Input resistance k Accuracy Linearity deviation <0,02 of unit Influence of temperature on Measurement range m/: <0.4 type 0.2 of unit the zero point per 0K Measurement range 2m/: <0.2 type 0. of unit Influence of temperature on the measurement sensitivity per 0K referring to the measured value < 0,; type. 0,0 Analogue output <0,0; type. 0,00 Display / digital Resolution Peak value >30000 parts RMS >0000 parts Output Analogue output filter -3dB cut-off frequency, Bessel, 2. order Digital output filter - 3dB cut-off frequency Digital output measuring rate Analogue output Source resistance Control cables 3.; 20; 700 (can be switched using software) 0.0..700 0..370 -...+ 47 High level: 3.4 (active high) Automatic zero-point adjustment Low level: <.4 4 Tel +49 (0)3302 720 0, Fax +49 (0)3302 720 9, info@me-systeme.de, www.me-systeme.de db db

Supply Supply voltage Nominal range Operating range Size alue Unit 7..27...30 Power input 2 (charge battery: max. ) A Battery 3,2 Wh Operating time with battery Normal operation Standby Duration of battery charging Supply voltage 0..27 Supply with USB (standby operation) Interface USB version max. 20 max. 300 max. max. 27 2.0 Fullspeed Device classes Mass Storage Device, Communication Device Class Memory card SD (.x), SDHC File system FAT, FAT32 Functions, user menu (selection) Parameter memory Last setting (automatic) Manufacturer s settings parameter sets Other functions - programmable amplification - programmable adjustment of the digital final value - activation of the zero-point adjustment Temperature range Nominal temperature range 0 +0 Storage temperature range Dimensions L x B x H Weight Protection class -20 +70 3 x 7 x 0 0 IP / IP ) The analogue input is not switched over to the analogue output. Absolute limit values (all voltages based on supply chassis) Differential input:: Sense inputs: Control cables: Analogue input: Subject to technical modifications. ersion. 7.04.203-2 +2-2 +2-30 +30-20 +20 DC DC Days C C mm g Tel +49 (0)3302 720 0, Fax +49 (0)3302 720 9, info@me-systeme.de, www.me-systeme.de