AS-i Safety Relay Output Module with Diagnostic Slave

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

AS-i Safety Output Module, IP20

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

System manual AS-i safety monitor AC041S /00 05/2013

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Operating instructions AC010S Compact AS-i E-STOP safety module

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i Safety Analog Input Module, IP20

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-Interface Safety Monitor. Connecting and Operating Instructions Version V 3.0

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Operating instructions Solenoid interlock MZM About this document. Content

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

Operating instructions Safety-monitoring module SRB-E-204ST / SRB-E-204PE. Content. 1. About this document

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-I Safety Monitor ASM1/ASM1E/ASM2E

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

MSI-RM2 Safety Relays

MANUAL VAS-*A-K12, VAS-*A-K12-U, VAS-*A1L-K12 AS-Interface Safety Monitor

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

Operating instructions. Standstill monitor A / / 2011

Operating instructions Safety-monitoring module SRB 324ST V About this document. Content

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Phone: Fax: Web: -

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Datasheet - SLB 200-C04-1R

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content

Pluto AS-i. Safety PLC. Approvals: Control of: Features:

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

PSR DC/ESP4/2X1/1X2

CONFIGURABLE SAFETY RELAYS

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

MANUAL Functional Safety

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

to 12a Added Standard and Electrical requirements for UL table 1.1

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions. Speed monitor D / / 2014

XPSMCMDO Digital output pairs expansion modules with screw term

Datasheet - SRB 301LC/B-24V

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Operating instructions Safety-monitoring module SRB 301ST V.2. 1 About this document

EM-F-7G Safety Extension Module

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

Original operating instructions Fail-safe inductive sensor GI712S

Operating instructions Safety sensor BNS About this document. Content

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Original operating instructions Fail-safe inductive sensor GG711S

Operating instructions Safety sensor RSS About this document. Content. 7 Set-up and maintenance 7.1 Functional testing 8 7.

PSR UC/ESAM4/3X1/1X2/B

ISO SINAMICS G110D FAQ

AS-i Sicherheitsmonitor ASM1/ASM1E Anschluss- und Betriebsanleitung. AS-i Safety Monitor ASM1/ASM1E Connecting and Operating Instructions

Operating instructions Safety sensor BNS About this document. Content

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Transcription:

AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3

Subject to modifications without notice. Generally, this manual refers to products without mentioning existing patents, utility models, or trademarks. The absence of any such references does not indicate that a product is patent-free.

Table of Contents Table of Contents AS-i Safety Relay Output Module with Diagnostic Slave 1 Symbol Catalog...5 1.1 Abbreviations... 5 2 General Remarks...6 2.1 Product information... 6 2.2 Function of this manual... 6 2.3 Target group... 6 2.4 AS-i specifikation 3.0... 6 3 Safety...7 3.1 Experienced staff... 7 3.2 Application area of the device... 7 3.3 Correct use... 7 3.4 Disposal... 8 4 Product Description...9 4.1 AS-i Safety at Work... 9 4.1.1 Special characteristics of the AS-i Safety Output Relay... 9 4.2 Technical Data... 10 4.3 Safety relevant data... 14 4.4 Connecting a safety contactor... 15 5 Maintenance...16 5.1 Controlling safe shutdowns... 16 6 Address Assignment...17 6.1 Programming of the safety relevant AS-i address... 17 6.2 Programming of the non-safety relevant AS-i address... 17 7 Safety Requirements...18 3

EC Declaration of Conformity EC Declaration of Conformity EC Declaration of conformity Translation of the original declaration of conformity K.A. Schmersal GmbH & Co. KG Möddinghofe 30, 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described safety components both in its basic design and construction conform to the applicable European Directives. Name of the safety component: Safe output module Type: ASOM-1SO-R2 Description of the safety component: Safe AS-i output module with relay enabling Relevant EC-Directives: 2006/42/EC EC-Machinery Directive 2004/108/EC EMC-Directive Person authorized for the compilation of the technical documentation: Notified body for the prototype test: Oliver Wacker Möddinghofe 30 42279 Wuppertal TÜV NORD CERT GmbH Langemarckstraße 20 45141 Essen, Germany ID n : 0044 EC-prototype test certificate: 44 205 12 410213 007 Place and date of issue: Wuppertal, September 03, 2012 4

Symbol Catalog 1. Symbol Catalog Information! This symbol indicates important information. Attention! This symbol warns of a potential failure. Non-compliance may lead to interruptions of the device, the connected peripheral systems, or plant, potentially leading to total malfunctioning. Warning! This symbol warns of an imminent danger. Non-compliance may lead to personal injuries that could be fatal or result in material damages and destruction. 1.1 Abbreviations AS-i AOPD CRC I/O EDM EMC ESD PELV PFD PLC SaW AS-interface (actuator sensor interface) Active opto-electronic protective device Cyclic redundancy check Input/output External device monitoring Electromagnetic compliance Electrostatic discharge Protective extra-low voltage Probability of failure on demand Programmable logic control Safety at Work, safety technic 5

General Remarks 2. General Remarks Please read this chapter carefully before working with the documentation and the "AS-i Safety Relay Output Module with Diagnostic Slave". 2.1 Product information This user manual is valid for the following Schmersal devices: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM input ASOM-1SO-R2 2.2 Function of this manual This manual instructs for the safe assembly, electrical installation, addressing, start-up as well as for the operation and for the maintenance of the AS-i Safety Output Relay. This manual does not provide instructions for operating machines, on which this module is built in. Please view the appropriate machine manual for corresponding information. Information! Additional information concerning the technical data as well as the parameterization of the AS-i Safety Output Relay can be found in data sheet ASOM-1SO-R2 that can be located at http://www.schmersal.net. 2.3 Target group This manual is intended for designers, developers and operators of systems that will be safeguarded by one or more AS-i Safety Output Relays. The manual is also targeted to people integrating AS-i Safety Output Relays into machinery, performing the initial start-up, or maintaining them. 2.4 AS-i specifikation 3.0 The "AS-i Safety Relay Output Module with Diagnostic Slave" is designed according to the AS-i specification 3.0. Earlier specifications (2.1 and 2.0) continue to be fully supported. 6

Safety 3. Safety This chapter contains user safety information. Warning! Please read this chapter carefully before using the AS-i Safety Output Relay in combination with other machine safeguarding components on protected machinery. 3.1 Experienced staff The AS-i Safety Relay Output Module with Diagnostic Slave must only be installed, operated, and maintained by qualified staff. Qualified is a person who has a suitable technical education has been instructed in operating the machinery and has been informed about the valid safety guidelines by the machinery operator has access to the user manual. 3.2 Application area of the device The ASOM-1SO-R2 is a decentralized output-module that safely controls actuators on the AS-i Safety at Work (SaW) safety bus system. In this set-up, a Safety Monitor or a Gateway with integrated Safety Monitor, respectively, controls the ASOM-1SO-R2. A special characteristic of this module is its two different kinds of AS-i addresses: Safe AS-i address ASOM-1SO-R2 listens to the communication on the safe address and switches based on these data. Non-safety relevant AS-i address The non-safety relevant AS-i address is used for diagnostic purposes and for switching under PLC control. All SaW output modules with the same safe AS-I address switch at the same time. The ASOM-1SO-R2 is certified according to EN 62 061, SIL 3, and EN 13 849, performance level e. 3.3 Correct use The AS-i Safety Relay Output Module with Diagnostic Slave must only be used as defined in chap. Application area of the device. The AS-i Safety Relay Output Module with Diagnostic Slave must only be used on the system, at which it was installed in accordance with this manual by adept personnel. Information! If used in a way differing from this description or if the device has been changed in any way even during installation any warranty claims with respect to Schmersal are invalid. 7

Safety 3.4 Disposal Information! Electronic waste is hazardous waste. Please comply with all local ordinances when disposing this product! The device does not contain batteries that need to be removed before disposing it. 8

Product Description 4. Product Description This chapter is intended to inform the reader about the special characteristics of the AS-i Safety Relay Output Module with Diagnostic Slave. It describes the design and the functionality of the devices. Warning! This chapter must be read before installation and operation of the device in conjunction with other safety components on protected machinery. 4.1 AS-i Safety at Work AS-i Safety at Work combines safe and non-safe data on a bus system. The classification AS-i Safety at Work identifies the safe data transfer that enables the integration of safety procedures in an AS-i network. The components of AS-i Safety at Work conform to EN 50295 and are compatible with all other AS-i components. Therefore, existing AS-i applications can easily be extended with safety-relevant functions. AS-i Safety at Work always requires a Safety Monitor (as a stand-alone device or integrated into a Gateway), that evaluates the safe signals on the bus, and a safe AS-Interface bus connection, that enables the transfer of safe signals from safety-relevant components (AS-i SaW input). Additionally, decentralized safe AS-I SaW outputs can be added. Controlled by the Safety Monitor these outputs can be used to safely switch off safe actuators. Several Safety Monitors and safe input and output slaves can be used on an AS-i system. At the same time, the Safety Monitors can be parameterized and, thus, be checked through AS-i and the configuration software. Information! By utilizing AS-i Safety at Work safety requirements up to category 4 according to EN 954-1 and additionally performance level "e" according to EN 13 849 as well as SIL 3 according to EN 62 061 can be satisfied. In order to satisfy the requirements of these safety categories, all peripheral components, for instance the Safety Monitors, all safe bus connections, and all connected sensors must satisfy these standards. 4.1.1 Special characteristics of the AS-i Safety Output Relay Two redundant, force-guided relays Two parallel, galvanically isolated contact sets 4 standard inputs External sensors supplied from AS-i Programming jack Operating mode selector switch 9

1.13 AS 1.14 ASI 1.23 NC 1.24 NC I I1 I2 I 3 1.Y1 I I1 RUN FAULT PWR ADDR I2 1.13 1.14 AS ASI I3 I1 I2 I3 1.Y1 1.23 NC PRG 1.Y1 ALARM OUT 1.24 NC AS-i Safety Relay Output Module with Diagnostic Slave Product Description 4.2 Technical Data Article no. ASOM-1SO-R2 ASO-1SO-R2: 2 AS-i modules in one housing! Inputs 1 diagnostic + 1 EDM 1 safety relay 1 diagnostic- and ASOM-1SO-R2 Outputs 1 relay 3A, 24V, DC-13 or 3A, 230V, AC-15 output 1 EDM input AS-i profile S.7.A.E ID1 Code 5 hex (default), value modifiable External device monitoring (EDM) supplied out of AS-i, approx. 24V, approx. 10 ma Indicators 3 x LED yellow (I1, I2, I3) state of standard inputs I1, I2, I3 1 x LED yellow (1.Y1) state EDM input 1.Y1 LED green (PWR) AS-i voltage ON + = LED red (FAULT) AS-i Fault LED yellow (OUT) for definition see table "device color" LED red (ALARM) PLC inidicates alarm Operating current < 200mA Safety address AB address Safety address Current supply of sensors 90mA + AB address Operating voltage AS-i (30V DC ) Voltage of insulation 6kV Applied standards EN 954-1 Cat 4 IEC61508 SIL3 EN 13 849-1/PLe Cat 4 EN IEC 62 061 SIL 3 Housing Din-rail mounting Ambient operating temperature 0 C... +55 C Storage temperature -25 C... +85 C Dimensions (L / W / H in mm) 114 / 22,5 / 99 Protection class DIN EN 60 529 Housing IP20 10

Product Description Diagnostic operation ID1 = 5 hex (default) Programming instructions (Bit values of inputs/outputs Diagnostic Slave) Bit AS-i output Bit AS-i input O0 1: Alarm LED on 0: Alarm LED off I0 Diagnostic (for definition see table device colors) O1 Parameter P1=1 Parameter P1=0 I1 not used 1: output controlled by safety release 0: inhibits output on irrespective of safety release O2 not used I2 O3 inexistent I3 1.Y1 Diagnostic (device colors) Value Color Description State change LED "Out" 0 green output on on 1 green flashing 2 yellow restart inhibit auxillary signal 2 1 Hz 3 yellow flashing 4 red output off off 5 red flashing waiting for "reset of error condition" auxillary signal 1 8 Hz 6 grey internal error, such as "fatal error" only via "Power On" on device all LEDs flashing 7 green/yellow output released, but not switched on switching-on by setting of O1 off Programming instructions Programming instructions Diagnostic Slave (bit values of the AS-i parameter) Bit P1 P1=1 safety output controlled by safety release only P1=0 safety output controlled by output O1 in addition to safety release Bits P0, P2, P3: not used Release AS-i Parameter (Diagnostic Slave) changes the function of output bit O1 AS-i Parameter P1=1 (default) O1=0 AS-i Parameter P1=1 O1=1 AS-i Parameter P1=0 O1=0 AS-i Parameter P1=0 O1=1 AS-i Safety Relay Output Module, safety release from the AS-i safety monitor...... not received... received safety output contact set closed safety output contact set closed safety output contact set closed 3I standard inputs (instaed of diagnostic) ID1=7 hex, or ID1=F hex Connection of sensors Programming instructions (Bit values of inputs/outputs AB-Slave) Bit AS-i output Bit AS-i input O0 1: Alarm LED on I0 I1 0: Alarm LED off O1 Parameter P1=1 Parameter P1=0 I1 I2 not used 1: output controlles by safety release 0: inhabits output on irrespective of safety release O2 not used I2 Parameter P2=0 Parameter P2=1 I3 1: feedback for user: safety release on 0: feedback for user: safety release off O3 inexistent I3 1.Y1 11

Product Description Programming instructions Programming instructions AB slave (bit values of the AS-i parameter) Bit P2 P2=1 feedback: safety release at AS-i bit I2 / LED I3 P2=0 input I3 at AS-i bit I2 Bit P1 P1=1 safety output controlled by safety release only P1=0 safety output controlled by output O1 in addition to safety release Bits P0, P3 not used Release AS-i parameter (AB slave) changes the function of output bit O1 AS-i Parameter P1=1 (default) O1=0 AS-i Parameter P1=1 O1=1 AS-i Parameter P1=0 O1=0 AS-i Parameter P1=0 O1=1 AS-i Safety Relay Output Module, safety release from the AS-i safety monitor...... not received... received safety output contact set closed safety output contact set closed safety output contact set closed Operating elements and clamp assignment 1.13 1.23 Freigabe (Release) AS-i + AS-i - F-Logik (F-Logic) Freigabe (Release) AS-i 1.14 1.24 I I1 RUN FAULT PWR ADDR I2 I3 I1 I2 I3 1.Y1 1.Y1 PRG ALARM OUT Clamps/Switch Description I1, I2, I3 standard inputs I1, I2 and I3 1.13, 1.14 safety output contact set 1 1.23, 1.24 safety output contact set 2 I-, supply voltage for inputs (out of AS-i) 1.Y1 EDM / input for electronic device monitoring AS-i+, AS-i AS-i network connection ADDR addressing socket PRG protective mode not possible. Programming of safety-related AS-i address enabled RUN protective mode possible. Programming of non safety-related AS-i address enabled I1 I2 I3 1.Y1 Eingänge (Inputs) 1.13 1.14 AS ASI 1.23 NC 1.24 NC 12

Product Description LEDs State Signal / Description no operating voltage PWR (green) 1Hz operating voltage present, safety-related AS-i address and/or AS-i AB address is 0 operating voltage present FAULT (red) AS-i communication OK no data exchange with AB slave output relays contacts open restart inhibit, waiting for the start signal, the output relays switch-on after the start signal OUT (yellow) 1Hz 8Hz device is in unlockable error state. Waiting for "reset of error condition signal". After receiving this signal the device follows up with normal operation. output relays contacts closed ALARM (red) AS-i output bit A0 is not set AS-i output bit A0 is set I1, I2, I3, 1.Y1 (yellow) the corresponding input is not connected (mode standard inputs) or release has not been issued (I3, diagnostic mode) the corresponding input is connected (mode standard inputs) or release has not been issued (I3, diagnostic mode) (running light) switch is adjust to PRG position LED on LED flashing LED off In case all LEDs are blinking simultaneously in fast rythm a fatal error has been detected. This message is reset by a short-run disconnection of the power supply (Power On Reset). 13

Product Description 4.3 Safety relevant data Identification data Value Standard Safety category 4 EN 954-1 Safety category 4 EN 13849-1:2006/PLe Performance level (PL) e Cat 4 Safety Integrity Level (SIL) 3 IEC 61508 Usage time (TM) in years 20 EN 13849-1:2006/PLe Cat 4 Maximum operating time in month 12 IEC 61508 PFD 1 2 * 10-5 IEC 61508 EN 62061 PFH D 1 (Probability of a dangerous failure per hour) 3,3 * 10-9 IEC 61508 EN 62061 Max. system reaction time in milliseconds 50 IEC 61508 Tab. 4-1. 1.) The PFD and PFH D values stated here are related to the maximum operating time of 12 month and a maximum usage time of 20 years according to EN ISO 13849-1. The relay s maximum switch time (including the occurrence of errors) is 50 ms starting at the time the code sequence is present until the switch-off of the relay. Additionally, the response time of the monitor and the inputs must be included. 14

Product Description 4.4 Connecting a safety contactor I I 1 I + I 2 I + I 3 I + 1.Y1 3 2 1 RUN PRG L 1.13 1.14 ADDR L1 L2 L3 1.Y1 1.13 1.14 ASI + ASI 1.23 NC 1.24 NC K1 AS ASI K2 N Motor 15

Maintenance 5. Maintenance 5.1 Controlling safe shutdowns The plant safety engineer is responsible for verifying that the AS-i Safety Relay Output Module with Diagnostic Slave works correctly as part of the safety system. At least once a year it is necessary to verify the safe shutdown by initiating associated safety-related sensors or switchs: Attention! Press each safety-related AS-i slave and watch the reaction of the output circuits of the AS-i Safety Monitor. Attention! Check the maximum activated time and the total operating time. These values depend on the PFD value chosen for the total failure probability. Please refer to the information in chap. Safety relevant data. After reaching the projected maximum operating time (three, six, or twelve months) the entire safety system must be checked for proper operation. After reaching the projected total usage time (20 years) the device must be checked by the manufacturer concerning its proper operation. 16

Address Assignment 6. Address Assignment The device offers two different types of AS-i addresses: The safety relevant (single) AS-i address is the target address for the device through which it receives the signal for the safe release of the output. This address is not used for communication; the device only uses it to listen to ongoing communications. This address can only be programmed if the switch is set to PRG. The device uses the non-safety relevant (A/B) AS-i address to communicate with the master in order to exchange diagnostics data (I1 I3, 1.Y1) and control signals (Alarm LED). This address can only be programmed if the switch is set to RUN. 6.1 Programming of the safety relevant AS-i address 1. Set device switch to PRG. 2. Set desired address by using the hand-held addressing device or AS-i Master. 3. Check programmed address by using the hand-held addressing device or AS-i Master. 4. Check slave s ID code by using the hand-held addressing device or AS-i Master. The code should be set to F. 5. Check slave s ID1 code by using the hand-held addressing device or AS-i Master. Code should be the same as the tens-digit of the address. 6. Check slave s ID2 code by using the hand-held addressing device or AS-i Master. The code should be the same as the ones-digit of the address. 7. Check slave s IO code by using the hand-held addressing device or AS-i Master. The code should be 7. 8. If the settings in steps 3 to 7 were correct continue with step 9. Otherwise repeat, starting with step 1. 9. Set the switch on the device to RUN.. Warning! The correct safety function of the device must be verified once installed within the protected machinery! 6.2 Programming of the non-safety relevant AS-i address This address can be programmed by using the hand-held addressing device or AS-i Master when the switch is set to RUN. 17

Safety Requirements 7. Safety Requirements The device uses two redundant, force-guided relays. The module recognizes if one of the relays does not switch (for instance if the contacts are welded). The contact sets 1.13/1.23 and 1.14/1.24 use the same relay; they do not operate independently. The contacts 1.13, 1.23, 1.14, 1.24 are potential-free. A cross-short check is not available. If the device is set up to control two independent safety contactors, connected in series, the connection between the safety contactors and the device must never be subjected to another potential as this could result in the inadvertent activation of the safety contactors. Input 1.Y1, just like inputs I1... I3, is a standard AS-i input. 18