SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Similar documents
PIX 515/515E. PIX 515/515E Product Overview CHAPTER

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Basketball Shot Clock Set LX2180 Manual

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

Switched Mode Power Supply Operating manual PAP800

Installing the Cisco MDS 9020 Fabric Switch

PIX 520. PIX 520 Product Overview CHAPTER

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

sonnen Installation Practical

VRp Three-Phase Precision AC Voltage Regulator

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

MC 11 EB-2 Power supply cabinet with external bus, AC version

Rexroth Controller Installation & Operations Manual

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

INSTALLATION MANUAL SLI 50 INVERTER

Resolver to Digital Expansion Board

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

CHAPTER 2 INSTALLATION

PMC494 10BaseT to 10Base2 PMC Media Converter

ICS Entrance Management Sign Installation Guide. Version 1.0

PS/IO Circuit Board Retrofit

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

icore Kiosk system Installation Guide

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TH2683 Insulation Resistance Meter. User s Mannual

MODEL 9386 MULTI-SPORT TIMER

UPS READY POWER DISTRIBUTION ASSEMBLY

HV-CS kv Edge Mount Triaxial Jack

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

Installing and Removing SDRAM and DRAM

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

PIX 535. PIX 535 Product Overview CHAPTER

Replacing the Power Supply

Plasma Panel Replacement Guide DU-42PX12X

Analog Monitor Installation Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Model 2380 Rack-Mount Kit

Model HM-535 Power Supply Installation and Service Instructions

FC-25/50DA Main Circuit Board Replacement Product Installation Document

TA18 active subwoofer. user manual

DYNAVISION D2 TM INSTALLATION MANUAL

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Model 2657A-LIM-3 LO Interconnect Module

Lag-Time Reader INSTALLATION / OPERATIONS MANUAL

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Treadmill Embedded Touch Screen Won t Power Up

INSTALLATION / USER MANUAL UNINTERRUPTIBLE POWER SUPPLY

Service & Maintenance

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SAFETY INSTRUCTIONS WARNING DANGER CAUTION

Charging Cabinet Owner s Manual

4100/ VDC Converter Installation Instructions

MA-4006, MD-4006 and MU-4006 Mounting Assemblies

CAUTION READ CAREFULLY

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

High Voltage Power Supply (MMPS) - Troubleshooting Guide

Model 2380 Rack-Mount Kit

Installation Instructions

COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Analog Input Installation Manual

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

CHAPTER 2 INSTALLATION

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Replacing the Gateway M275 Keyboard

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Procedure to Install an IO Expansion Cage Assembly in a Maxum II Modular Oven Analyzer

TRC-190 User s Manual

To connect the AC adapter:

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Lightning Stitch Assembly

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TPC25 active crossover. user manual

LVN5200A-R2, rev. 1, Hardware Installation Guide

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

ELECTRO-MECH SCOREBOARD CO.

HP4 headphone amplifier. user manual

MOS-1110Y-0101E Isolated 16 DI/8 DO, 1-Ch, DB37, PCIe I/F

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Metro-Optical Transport Access Nodes

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Transcription:

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors Compact Generator. DO NOT PLUG IN THE UNIT TO THE MAINS SOCKET UNTIL SPECIFICALLY INSTRUCTED IN THIS SERVICE MANUAL. THIS GENERATOR IS PERMANENTLY CONNECTED TO THE POWER LINE THROUGH A LINE PLUG. IT IS POWERED ON UNLESS THE SAFETY SWITCH INSTALLED IN THE ROOM ELECTRICAL CABINET IS OFF. WHEN THE UNIT IS POWERED, THE NEON (GREEN) LOCATED ON THE TRANSFORMER 6T2 IS ON. KEEP THE PROTECTION COVERS IN PLACE ALL THE TIME, ONLY REMOVE THE COVERS TO PERFORM SERVICE OPERATIONS. INTERNAL PARTS (CAPACITOR OF HV INVERTER, STORAGE CAPACITORS MODULE, LINE FUSES, DC BUS FUSES, ETC.) CAN BE PERMANENTLY POWERED ON AND HAVE THE FULL VOLTAGE POTENTIAL OF THE CAPACITORS (APPROX. 800 VDC), ALTHOUGH THE UNIT IS DISCONNECTED FROM THE LINE OR THE CONTROL CONSOLE IS OFF. USE CAUTION WHEN WORKING IN THIS AREA. 1

SECTION 1 UNPACKING AND INSTALLATION The generator is shipped in one box to facilitate transport and installation. Upon receipt of the X-ray unit and associated equipment, inspect all shipping containers for signs of damage. If damage is found, notify the carrier or his agent immediately. 1.1 CAPACITORS POWERED COMPACT GENERATORS Illustration 1-1 Capacitors Compact Generators 1. Open the shipping box, then move away the Control Console, Interconnection Cables, Cabinet Cover and other furnished parts. Do not discard any packing material such as envelopes, boxes, bags until all parts are accounted for as listed on the packing list. 2. Remove the packing material from the pallet. 3. Remove the Generator Cabinet from the shipping pallet and place it near to its site in the room. At least two people are required for this operation. 4. When the equipment is unpacked, verify that all items on the customer order are present, and the hardware and internal wiring is secure. 5. Check the part numbers / serial numbers of each component with its identification labels, and inspect all pieces for visible damage. If any damaged parts are found, repair or order replacements to prevent unnecessary delay in installation. 2

6. Usually Generator Cabinet stands freestanding. Seismic areas and other conditions require to make firm the Generator Cabinet to the floor through the mounting holes on the bottom. In some cases due to transport safety requirements, the HV Transformer is shipped out of the Generator Cabinet. Install the HV Transformer inside the Cabinet (upper area) and secure it with the respective anchors or plates, then connect the following cables from the Power Module to the corresponding terminals on the HV Transformer: G G P2-Shield (2 thin wires), P1 and P3. Take care to connect these cables to the stud-brass terminals, use two wrenches to tighten the nuts and avoid twisting the studs. Ground wire to Ground stud. G Connector J1. THE HV TRANSFORMER HAS TO BE SECURED WITH ITS ANCHORS OR PLATES INSIDE THE CABINET. OTHERWISE P1, P2 AND P3 STUDS MAY BE IN CONTACT WITH THE CABINET FRAME AND PRODUCE A SHORT-CIRCUIT. 7. Control Console can be freestanding, wall supported or mounted on an optional Pedestal. Console is provided with a several mounting holes on the bottom for anchoring to the Pedestal or another support. Console CPU Boards and AEC Control Board can be located inside the Console (standard) or inside the Generator Cabinet (for Serial communication). 8. When a Pedestal is used, secure the Pedestal to the floor through the anchoring holes on its base and place the cover base. Assemble the Console to the Pedestal through the mounting holes on the bottom of the Console. 9. When the Console is wall supported, secure the support to the wall and assemble the Console to the support through the mounting holes on the bottom of the Console. 10. Leave a working area around the equipment until its final assembly. 3

SECTION 2 CABLE CONNECTIONS This section provides the information necessary to connect the Generator Cables with the system and options. Note. Note. For more information about electrical requirements and cable connections, refer to Pre- and documents of the Service Manual. Identification of some terminal connections (TB, TS), boards, etc... along this document (text and schematics) may have a prefix number which indicates the module number in the equipment. (a.e. TS2 as 4TS2, 10TS2 or 11TS2). Some safety devices such as Safety Switch / Emergency Switch, Warning Light, and Door Interlock Switch are supplied and installed by the customer. Verify that safety devices have been properly installed and routed during the Pre- procedure. 2.1 CABLE ROUTING INSIDE CAPACITORS GENERATOR CABINET Illustration 2-1 Cable Outlet Previous to cable connections inside the Generator Cabinet, route and secure the cables in the following way: 1. All cables have to be routed over the Fastening Bar (upper rear bar) of Cabinet Frame. Be in mind the Cable Outlet at the rear side of Cabinet Cover. Cable Outlet (rear side) 4

2. For Capacitors Compact Generators, Line Cord have to be fastened and routed over the Fastening Bar and Cabinet Frame as illustrated below, before connecting the cable to the Line Terminals (L1 and L2/N) in Fuses 8F1 and 8F2. 3. Stator and Interconnections Cables have to be routed internally through the Cabinet close to the Input Transformer. 4. Connect all cables as indicated along Section 2 Cable Connections of document in Service Manual. 5. Secure all cables to the Fastening Bar using cable ties after all cable / wire connections are completed. Illustration 2-2 Cable Routing Stator & Interconnections Cables Entrance Cable Ties Fastening Bar Input Transformer Ground Terminals HV Cables Stator & Interconnections Cables Cable Outlet (rear side) Power Line Cord in Capacitors Generator Stator & Interconnections Cables Entrances Cable Ties Input Line Fuses 5

2.1.1 CAPACITOR COMPACT GENERATORS 1. Before connecting the cables, check that an Emergency Switch has been connected to Room Electrical Cabinet so that it cuts the power to the generator when it is off. 2. Measure the line voltage at the wall socket. Obtain a suitable line cord and plug to conform to local codes and requirements. The power supply line should be according to the Pre- document. 3. Cut the line cord to the appropriate length, route and connect it to the Line Terminals (L1 and L2/N) of Fuses 8F1 and 8F2, and the Ground wire to the Ground Stud close to these fuses. (Refer to Schematics 54302020). 4. Connections of Power Line wires must be made as indicated below: INPUT LINE VOLTAGE 1 Phase + Neutral 2 Phases L1--Phase Neutral Ground L1--Phase L2--Phase Ground L1 (8F1) N (8F2) GND Stud L1 (8F1) L2 (8F2) GND Stud THE CAPACITORS GENERATOR IS FACTORY DELIVERED TO OPERATE ON PHASE AND NEUTRAL. IN CASE OF CONNECTING THE UNIT TO A TWO PHASES LINE, REPLACE NEUTRAL CARTRIDGE BY THE FUSE SUPPLIED WITH THE GENERATOR. Illustration 2-3 Power Line Connection 5. Install the line plug to the other end of the cord. Extra fuse for 2 Phases Line Power Line Cord GND Stud Cable Ties L1 (8F1) Neutral or L2 (8F2) Input Line Fuses 6

6. According to the Room Circuit Breaker (Magnetothermic), set the Jumper at the Capacitors Charger Board (A3517-01) to the indicated position. This Jumper is factory set at JU2 for a 20 Amps Circuit Braker. CIRCUIT BRAKER (MAGNETOTHERMIC) 8Amps JUMPER POSITION JU6 10 Amps JU5 12.5 Amps JU4 16 Amps JU3 20 Amps JU2 Note.- Jumper JU1 has to be always set at Manual position Illustration 2-4 Jumper Setting at Capacitors Charger Board 7. Re-install the plastic covers over Inputy Line Fuses and Capacitor Charger Board. DO NOT PLUG IN THE UNIT TO THE MAINS SOCKET UNTIL SPECIFICALLY INSTRUCTED IN THIS SERVICE MANUAL. 7

2.1.2 PROCEDURE FOR STORAGE CAPACITORS DISCHARGING AND VOLTAGE TESTING PERFORM THIS PROCEDURE PREVIOUS TO MANIPULATE INSIDE THE CAPACITORS GENERATOR FOR SERVICE. CAREFULLY HANDLE ALL INTERNAL PARTS OF THE EQUIPMENT, SPECIALLY PARTS UNDER COVERS. DANGEROUS DC VOLTAGE IS PRESENT IN THE UNIT EVEN IF IT IS UNPLUGGED FROM THE AC LINE. NEVER TOUCH METAL PARTS UNDER COVERS BEFORE TESTING THAT VOLTAGE IS BELOW 10 VDC. PERFORM THE PROCEDURE FOR CAPACITORS DISCHARGING AND VOLTAGE TESTING PREVIOUS TO MANIPULATE INSIDE THE GENERATOR FOR SERVICE. KEEP IN MIND THE GENERAL CAUTIONS FOR CAPACITOR ASSISTED GENERATORS INDICATED BEFORE. 1. With the Generator turned OFF, be sure that the Power Supply Cable is unplugged from the Mains socket. 2. Take away the Generator cover. 3. Carefully, remove the Protection Cover over the Capacitor Charger Board (A3517--xx). DO NOT TOUCH ANY METAL PART UNDER COVERS UNTIL THE CAPACITORS ARE FULLY DISCHARGED AFTER THIS PROCEDURE. 8

4. Resistor 8R1 (1K5 ohms, 250 W) is assembles close to the Capacitor Charger Board to allow the Capacitors discharging. Connector J4 (from this resistor) must be disconnected for normal operation of the Unit, and ONLY MUST BE CONNECTED to the J4 of the Capactitor Charger Board for Capacitors discharging process. 5. Plug Connector J4 in the Capacitor Charging Board. Check that LEDs D48 and D49 of this Board are blinking. When the Capacitors are fully discharged, both LEDs will be OFF. Capacitors will be discharged from 800 VDC (fully charged) to 10 VDC in approximately 5 minutes. Illustration 2-5 Connection of J4 for Capacitor Discharging LEDs D48 & D49 Connector J4 (PCB Connector) Capacitors Charging Board Connector J4 (Aerial Connector) Resistor 8R1 9

6. Check that the voltage stored in Capacitors is < 10 VDC (maximum voltage for a safe service manipulation). It is recommended that voltage will be close to 0 VDC. For that, check that LEDs D48 and D49 are OFF, and then measure the voltage at the base of Fuses 8F3 and 8F4. DO NOT MANIPULATE INSIDE THE UNIT WITHOUT CHECKING THAT VOLTAGE IN CAPACITORS MODULE HAS BEEN DISCHARGED (LESS THAN 10 VDC). Illustration 2-6 Checking voltage Check that voltage on 8F3 and 8F4 is > 10 VDC Note. Storage Capacitors are fully charged four seconds after turning the Generator ON (for a line of 230 VAC with selection of 20 A in the Generator, or maximum 40 seconds for a line of 110 VAC with selection of 8 A in the Generator). 10