Cisco ONS CL Shelf Assembly Hardware

Similar documents
Cisco ONS MA Shelf Assembly Hardware

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.

Install the Cisco ONS CL

Cisco ONS MA Shelf Assembly Hardware

Install the Cisco ONS CL

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

Shelf and Backplane Hardware

Installing the Cisco 2524 and Cisco 2525 Routers

Shelf and FMEC Hardware

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Installing the Cisco AS5400XM Universal Gateway

Connecting and Routing the Cables

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Install the Shelf and Backplane Cable

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Overview. Features CHAPTER

Connecting Power and Ground

Junos WebApp Secure 5.0 Hardware Guide

Preparing to Install the Cisco AS5350XM Universal Gateway

Connecting and Routing the Cables and Wires

Installing Power Modules

DLPs H1 to H99. DLP-H1 Unpack and Verify the Shelf Assembly. DLP-H2 Inspect the Shelf Assembly CHAPTER

Preparing to Install the VG248

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installing the Cisco XR Router

Quick Start Guide. C-100 Series Switches

Installation Job Aid for Ethernet Routing Switch 3600 Series

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Installing the Cisco ME 2600X Shelf

Installing the Cisco NCS 2006 Door and Other Modules

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Site Preparation CHAPTER

Installing the DS1-28/DS3-EC1-3 and DS1-84/DS3-EC1-3 Cards in the Cisco ONS MA

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

This chapter describes fabric card, line card, and CPT 50 panel.

Power Supply Installation

Installation Manual. Table of Contents

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

TRC-190 User s Manual

Installing the Cisco NCS 2006 Door and Other Modules

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

D-Link Switch User Manual. Table of Contents

Installation Job Aid for VSP 4450GTX-HT- PWR+

ECS4620 Series 28/52-Port Layer 3 Stackable GE Switch Installation Guide

Installing the ONS M12 (ANSI and ETSI) Shelf

Installation Job Aid for Ethernet Routing Switch 5900 Series

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Installation Job Aid for VSP 4850GTS

FSM-510G Series Ethernet Management Switch Quick Start Guide

High Power over Ethernet Midspans PD Port Model PD Port Model

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Replacing the Power Supply

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Traverse Hardware Installation and Commissioning Guide

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Perle SMI Media Converter Installation Guide

Installing the Cisco MDS 9020 Fabric Switch

Metropolis ADM MultiService Mux Compact Shelf

8~14-Port Managed Ethernet Switch

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

Introducing the Cisco NAM 2220 Appliance

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Installing and Removing SDRAM and DRAM

Introduction to the CRS Back-to-Back System

Installation Instructions for UL Rev A

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Card Protection. 4.1 Overview CHAPTER

Installing a Network Module

TRC-190 User s Manual

Disclaimer. Note that the Midspan is designed for indoor use only.

Storage/Control I/O Module

Maintaining the Cisco Internet Router

ex-s1110-xt Gigabit Ethernet Extenders

Perle 10GT Media Converters

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PD-6506, PD & PD-6524

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

PIX 520. PIX 520 Product Overview CHAPTER

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

F1000 User's Manual. (Version: V1.01)

10/28/52-Port Web-Smart Pro Gigabit Ethernet Switch 26-Port Web-Smart Pro 10G Ethernet Switch. Installation Guide.

INSTALLATION GUIDE. AXIS 291 1U Video Server Rack ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL

MONITORING INTELLIRACK USER MANUAL

Overview: Cisco Series Router Shared Port Adapters

Cisco Internet Router Chassis and Backplane Replacement Instructions

DS3 SPOT Bays (CLEC and TIE Bay) Installation and Maintenance Guide)

iconverter 2-Module Power Chassis

PLC Racks IC697CHS782/783

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

PACSystems RX7i IC698CHS009/119

Transcription:

CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide. Chapter topics include: 1.1 Installation Overview, page 1-1 1.2 Rack Installation, page 1-2 1.3 Power and Ground Description, page 1-5 1.4 Cable Description and Installation, page 1-5 1.5 Fans, page 1-9 1.6 Cards and Slots, page 1-9 The Cisco ONS 15310-CL assembly is intended for use with telecommunications equipment only. The ONS 15310-CL is designed to comply with Telcordia GR-1089-CORE Type 2 and Type 4. Install and operate the ONS 15310-CL only in environments that do not expose wiring or cabling to the outside plant. Acceptable applications include Central Office Environments (COEs), Electronic Equipment Enclosures (EEEs), Controlled Environment Vaults (CEVs), huts, and Customer Premise Environments (CPEs). 1.1 Installation Overview You can mount the ONS 15310-CL in a 19- or 23-inch (482.6 or 584.2 mm) rack or it can be placed on a flat surface using the installed rubber feet. When installed in a rack, reversible mounting brackets should be used on each side of the shelf. The shelf assembly weighs 11.5 pounds (5.22 kg) without a card installed and 12.5 pounds (5.67 kg) with all hardware installed. The ONS 15310-CL is powered using 48 VDC or 100/240 VAC power. AC power terminals are accessible on the front panel and the DC power connection is accessible on the rear of the shelf assembly. CRIT, MAJ, MIN, and REM alarm LEDs are visible on the front of the node and indicate whether a Critical, Major, Minor, or Remote alarm is present anywhere on the ONS 15310-CL. Ethernet cards, small form-factor pluggables (SFPs), cables, and ports are accessible through the front of the shelf assembly only. 1-1

1.2 Rack Installation Chapter 1 When installed in an equipment rack, the ONS 15310-CL assembly is typically connected to a fuse and alarm panel that provides centralized alarm connection points and distributed power for the ONS 15310-CL. Fuse and alarm panels are third-party equipment and are not described in this documentation. If you are unsure about the requirements or specifications for a fuse and alarm panel, consult the documentation for that product. In this chapter, the terms ONS 15310-CL and shelf assembly are used interchangeably. In the installation context, these terms have the same meaning. Otherwise, shelf assembly refers to the physical steel enclosure that holds cards and connects power, and ONS 15310-CL refers to the entire system, both hardware and software. Install the ONS 15310-CL in compliance with your local and national electrical codes: United States: National Fire Protection Association (NFPA) 70; United States National Electrical Code Canada: Canadian Electrical Code, Part I, CSA C22.1 Other countries: If local and national electrical codes, are not available, refer to IEC 364, Part 1 through Part 7 Detailed compliance and safety information is provided in the Cisco Optical Transport Products Safety and Compliance Information document that ships with the Cisco ONS 15310-CL. 1.2 Rack Installation The ONS 15310-CL is easily mounted in a 19- or 23-inch (482.6 or 584.2 mm) equipment rack. The shelf assembly can be mounted so that it projects five inches from the front of the rack. It mounts in both EIA-standard and Telcordia-standard racks. The shelf assembly is a total of 17.25 inches (438.2 mm) wide. The ONS 15310-CL measures 1.75 inches high, 19 or 23 inches wide (depending on which brackets are installed), and 15 inches deep (44.4 x 482.6 or 584.2 x 381 mm). Figure 1-1 shows the dimensions of the ONS 15310-CL shelf assembly. 1-2

Chapter 1 1.2.1 Mounting Bracket Figure 1-1 ONS 15310-CL Shelf Assembly Dimensions Top View 17.25 in. (438.2 mm) 13.0 in. (330.2 mm) 19.0 or 23.0 in. (482.6 or 584.2 mm) Side View 13.0 in. (330.2 mm) Front View 17.25 in. (438.2 mm) 1.75 in. (44.4 mm) 19.0 or 23.0 in. (482.6 or 584.2 mm) 124898 1.2.1 Mounting Bracket Caution Use only the fastening hardware provided with the ONS 15310-CL to prevent loosening, deterioration, and electromechanical corrosion of the hardware and joined material. Caution When mounting the ONS 15310-CL in a frame with a non-conductive coating (such as paint, lacquer, or enamel) use either the thread-forming screws provided with the ONS 15310-CL shipping kit or remove the coating from the threads to ensure electrical continuity. The shelf assembly comes with two mounting brackets, one for use with a 19-inch (482.6 mm) or 23-inch (584.2 mm) rack. Figure 1-2 shows the mounting bracket orientation for a 19-inch rack. 1-3

1.2.1 Mounting Bracket Chapter 1 Figure 1-2 Mounting Brackets (19-Inch Orientation) Figure 1-3 shows the mounting bracket orientations for a 23-inch rack. The brackets are installed in the same mounting holes for both rack sizes. Figure 1-3 Mounting Brackets (23-Inch Orientation) 124943 124942 1-4

Chapter 1 1.2.2 Mounting a Single Node 1.2.2 Mounting a Single Node Mounting the ONS 15310-CL in a rack requires a minimum of 1.75 inches of vertical rack space (plus 1 inch [25.4 mm] for air flow). To ensure that the mounting is secure, use two #12-24 mounting screws for each side of the shelf assembly. 1.2.3 Mounting Multiple Nodes Most standard seven-foot (2.1 m) racks can hold numerous ONS 15310-CL nodes and a fuse and alarm panel. 1.3 Power and Ground Description This section describes how to connect the ONS 15310-CL shelf assembly to the power supply. For detailed procedures, refer to the Install the Cisco ONS 15310-CL chapter in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide. Terminate the chassis ground on the rear of the shelf assembly to either the office ground or rack ground before you install the power. Use the grounding lug to attach the #6 AWG ground cable to the shelf assembly according to local site practice. Ground one cable to ground the shelf assembly. Terminate the other end of the rack ground cable to ground according to local site practice. If the system loses power or the 15310-CL-CTX card is reset, you must reset the ONS 15310-CL clock unless the node has been previously provisioned to use Simple Network Time Protocol (SNTP) to update the clock over the LAN. Caution Always use the supplied ESD wristband when working with a powered ONS 15310-CL. Plug the wristband cable into the ESD jack located to the left of the expansion slot. Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022 The ONS 15310-CL can be ordered with either AC or DC power capability. The DC power option provides redundant 48 VDC power terminals on the rear of the chassis. The terminals are labeled A and B and are located at each end of the shelf assembly. The ONS 15310-CL AC power connector is located at the bottom right on the front of the chassis. The power cables are provided with the ship kit. To install redundant power feeds, use four power cables and one ground cable. For a single power feed, only two power cables and one ground cable are required. Use #14 AWG power cables and a #6 AWG ground cable and, to ensure circuit overcurrent protection, use a conductor with low impedance. However, the conductor must have the capability to safely conduct any fault current that might be imposed. Do not use aluminum conductors. 1.4 Cable Description and Installation This section describes fiber-optic, DS-3/EC-1 (coaxial), DS-1 (96-pin LFH), UDC, and twisted-pair cables. 1-5

1.4.1 Cabling Types Chapter 1 1.4.1 Cabling Types The following types of cables are used with the ONS 15310-CL: Optical cables: The OC-3/12 signals operate over fiber spans via small form-factor pluggable (SFP) optics, including intermediate-reach (IR), and long-reach (LR) SFPs. Specification references can be found for the interface in ITU G.957 and GR-253. See 1.4.2 Fiber Cable Installation section on page 1-6 for more information. Make sure the fiber cables do not bend excessively; maintaining a proper bend radius prevents damage to the optical cable. Coaxial cables: Coaxial cables connect to the electrical ports using MiniBNC cable connectors. Coaxial cables carry DS-3/EC-1 traffic to and from the ONS 15310-CL. The ONS 15310-CL supports up to three transmit and three receive coaxial connectors on each shelf assembly. Cisco recommends you use Cisco-orderable MiniBNC cables to ensure interoperability between the cables and Trompeter MiniBNC connectors on the ONS 15310-CL. LFH cables: A 96-pin LFH cable provides access to a maximum of 21 DS-1s. See the 1.4.4 DS-1 Cable Installation section on page 1-7 for more information about the DS-1 cables and connectors. RJ-45 cables: RJ-45 cables connect to the alarm, LAN, CRAFT, UDC, and timing (BITS) ports. Shielded Twisted-pair (STP) #22 or #24 AWG wire is required for the CRAFT, and UDC ports. Unshielded Twisted-pair is sufficient for the alarm, LAN, and timing ports. 1.4.2 Fiber Cable Installation To install fiber-optic cables on the ONS 15310-CL, a fiber cable with an LC connector must be connected to the SFPs installed in the SFP port on the ONS 15310-CL. The left side connector on the SFP is the transmit port and the right side connector is the receive port. Cisco recommends that you label the transmit and receive ports and the working and protection fibers at each end of the fiber span to avoid confusion with cables that are similar in appearance. Caution You must provide some type of strain relief for the cables, using either the tie-bars specifically designed for the ONS 15310-CL or a site-specific solution. Clean all fiber connectors thoroughly. Dust particles can degrade performance. Put caps on any fiber connectors that you do not use. 1.4.3 Coaxial Cable Installation For DS-3/EC-1 traffic the ONS 15310-CL uses coaxial cables and connectors. Cisco recommends connecting a 735A coaxial cable to a patch panel. Use a compatible straight male BNC connector to connect the cable to the DS-3/EC-1 ports. The DS-3/EC-1 cables should be terminated with MiniBNC connectors on the ONS 15310-CL side and BNC connectors on the client side. The electromagnetic compatibility (EMC) performance of the node depends on good-quality DS-3/EC-1 coaxial cables, such as Shuner Type G 03233 D, or the equivalent. 1-6

Chapter 1 1.4.4 DS-1 Cable Installation 1.4.4 DS-1 Cable Installation The ONS 15310-CL uses 96-pin LFH connector cabling for DS-1 connections. 1.4.5 Alarm Cable Installation The alarm cables attach to the front of the 15310-CL using an RJ-45 connector that plugs into the ALARM port. The other end of the cable plugs into the alarm-collection equipment. Terminate this end of the cable according to local site practice. The pins on the ALARM port correspond to the three external alarm inputs and the two external alarm outputs (controls) that you can define using Cisco Transport Controller (CTC). Table 1-1 lists the input alarm pinouts and the corresponding alarm function numbers assigned to each port. Table 1-1 Alarm Pin Assignments RJ-45 Pin Number Function 1 Alarm Contact 1+ 2 Alarm Contact 1 3 Alarm Contact 2+ 4 Alarm Contact 2 5 Alarm Input 1 6 Alarm Input 2 7 Alarm Input 3 8 Alarm Input Common Figure 1-4 shows RJ-45 pin numbering. Figure 1-4 Pins 1 and 8 on the RJ-45 Connector 49564 Pin 1 Pin 8 For more information about external alarms and controls, see the 11.6 External Alarms and Controls section on page 11-14. 1-7

1.4.6 BITS Cable Installation Chapter 1 1.4.6 BITS Cable Installation The building integrated timing supply (BITS) cables attach to the ONS 15310-CL using BITS clock cable and twisted-pair #22 or #24 unshielded AWG wire terminated with an RJ-45 connector that plugs into the BITS port. The other end of the cable plugs into the BITS clock. Terminate this end of the cable according to local site practice. The 15310-CL has one BITS input and one BITS output. The BITS inputs and outputs have corresponding pins on the RJ-45 BITS ports. When connecting BITS cable to the ONS 15310-CL, see Table 1-2 for the BITS cable pin assignments. For more information about connecting BITS timing to the ONS 15310-CL, refer to Chapter 7, Timing.. Table 1-2 BITS Cable Pin Assignments RJ-45 Pin Number Function 1 BITS Output+ 2 BITS Output 3 BITS Input+ 4 5 6 BITS Input 7 8 Refer to Telcordia SR-NWT-002224 for rules about how to provision timing references. 1.4.7 UDC Cable Installation The 64K/RS-232 user data channel (UDC) interface provides E1, E2, F1, and F2 byte input and output. When connecting UDC cable to the ONS 15310-CL, see Table 1-3 for the UDC cable pin assignments. Shielded Twisted-pair (STP) #22 or #24 AWG wire is required for the UDC ports.. Table 1-3 UDC Cable Pin Assignments Pin Number Function (RS-232 Mode) Function (64K Mode) 1 NC TX+ 2 DTR TX 3 TXD RX+ 4 GND GND 5 GND GND 6 RXC RX 1-8

Chapter 1 1.5 Fans Table 1-3 UDC Cable Pin Assignments (continued) Pin Number Function (RS-232 Mode) Function (64K Mode) 7 NC NC 8 NC NC 1.5 Fans The ONS 15310-CL has five fans permanently mounted to the inside of the chassis. The fans are not removable. 1.6 Cards and Slots Caution Always use the supplied ESD wristband when working with a powered ONS 15310-CL. Plug the wristband cable into the ESD jack located to the left of the expansion slot. The ONS 15310-CL provides one expansion slot that can accommodate one of two Ethernet cards, the CE-100T-8 card or the ML-100T-8 card. These cards have electrical plugs at the back that plug into electrical connectors on the shelf assembly backplane. When the ejectors are fully closed, the card plugs into the assembly backplane. Refer to Chapter 3, Card Reference for more information about ONS 15310-CL cards. 1-9

1.6 Cards and Slots Chapter 1 Figure 1-5 shows card installation for the ONS 15310-CL. Figure 1-5 Installing an Ethernet Card 124657 DS-1 and DS-3/EC-1 interfaces are not intended for direct connection to the network. These interfaces should be connected to the network via a CSU/DSU that has the proper certification. Table 1-4 lists the number of ports, line rates, connector options, and connector locations for ONS 15310-CL electrical, Ethernet, and optical interfaces. Table 1-4 Port Line Rates, Connector Types, and Locations Interface Ports Line Rate per Port Connector Type Connector Location DS-1 21 1.544 Mbps 96-pin LFH Front of the 15310-CL DS-3 3 44.736 Mbps 75-ohm MiniBNC Front of the 15310-CL EC-1 3 51.84 Mbps 75-ohm MiniBNC Front of the 15310-CL OC-3/OC-12 2 155.52 Mbps (STS-3) 622.08 Mbps (STS-12) LC Front of the 15310-CL CE-100T-8 8 10/100 Mbps RJ-45 CE-100T-8 card faceplate (expansion slot) ML-100T-8 8 10/1000 Mbps RJ-45 ML-100T-8 card faceplate (expansion slot) 1-10