Installation and operating instructions. PA Link1 parallel switch box Z

Similar documents
SCM030. MPPT Solar System Controller With. DC to DC Booster Input. Installation & Operating Instructions

Installation manual plugs and connectors with screw connection (16/32 A)

Solar Charge Controller

TVAC25100 TVAC25110 User manual

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

1 Channel Strobe Controller ORDERCODE 40226

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

Operating Instructions

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Expansion module EM-BAC-MOD-01. Installation manual

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

User Manual. Solar Inverter for Water Pump

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Conductive Level Controller

PAR56 10MM UV LED PAR. user manual

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

MU110-6U. Analog output module 6 channel. User guide

PV Rapid Shutdown device

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

Solar charge controller

Wa r n i n g-wa r n i n g-wa r n i n g

Promopar ORDERCODE 30120

Operating Instructions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

Accessories for stand-alone gird inverter SMART LOAD 6000

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

SolConeX extra-low voltage flange socket

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Octostrip ORDERCODE 42220

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Assembly instructions FMS-1 / FMS-2. Monitoring system

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

B63/ NS MS. EtherNet/IP LINK

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Pixel Panel 144 RGB effect panel. user manual

LED Par 64 Short DMX ORDERCODE 42431

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating instructions. Speed monitor D / / 2014

DuoFern Multiple Wall Controller

1 Channel Sliding Profile Dimmer ORDERCODE 50425

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

Colour Star Sky I DMX ORDERCODE 40341

PRO-75 SERIES. User manual

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Accessories for Sunny Central COMMUNICATION CABINET (COM-C)

Preparing to Install the VG248

Installation manual for for Schleifenbauer DPM3

INSTALLATION INSTRUCTIONS

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

External level devices for conductive point level switch

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

FT-20 Fire Training Fog Machine User Manual English

Charging Cabinet Owner s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Large Police Light 100W ORDERCODE 80361

D-Pack 6 Classic ORDERCODE 50315

Technical Manual Room temperature controller

User Guide. Control Box. RoscoLED TM.

LED Dancefloor ORDERCODE 42300

Smart Grid Tie Microinverter User Manual

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Manual Version: V1.00. Video Decoder Quick Guide

LED Pixel Rail Drive 640 controller. user manual

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

FT-20 Fire Training Fog Machine User Manual English

ICS Entrance Management Sign Installation Guide. Version 1.0

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Chameleon Stand-alone

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Dialock DT Lite. Operating instructions...2. Operating instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Content. Product Description

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Optional add-on cassette Attachment Instruction manual

Pure Sinewave Inverter

Transcription:

Installation and operating instructions PA Link1 parallel switch box EN

Index Introduction... 3 1 About these instructions...4 1.1 Applicability... 4 1.2 Users... 4 1.3 Description of symbols... 5 1.4 Scope of delivery... 5 2 Safety...6 2.1 Proper usage... 6 2.2 Other risks... 6 2.3 Behaviour in the case of faults... 6 2.4 Exclusion of liability... 6 3 Description of the connections...7 4 Installation...7 4.1 Mounting... 8 4.2 Connection... 9 4.3 Function test... 10 4.4 Making changes to the system... 11 5 Operation...11 5.1 Rotary switch settings... 11 6 Care, maintenance and service...12 7 Technical data...12 8 Fault diagnosis and troubleshooting...13 9 Commercial and legal guarantee conditions...13 10 Contact...14 2

Introduction Up to 4 Steca Solarix PI 500-12 (-60/-L60) / PI 550-24 (-60/-L60) / PI 1100-24 (-60/-L60) / PI 1500-48 (-60/-L60) stand-alone inverters can be operated in parallel with the PA Link1 parallel switch box on 115 V or 230 V (see table below). One stand-alone inverter works as a master, the others as slaves. The PA Link1 has one output for AC consumers (AC OUT). The PA Link1 optionally serves as a communication interface between the standalone inverters and a Tarom 4545, Tarom 4545-48, or Tarom MPPT 6000-M charge controller with StecaLink interface 1). This enables the PV system to be SOC 2) controlled. 1) See StecaLink communication instructions at www.steca.com. Firmware update for PA Link1 and StecaLink compatible charge controller might be necessary. 2) SOC = State of Charge; for more details, go to www.steca.com Example of a possible application. G F A E D B C Legend: A B C D E F G Solar module Solar charge controller Battery Steca Solarix PI sine wave inverter Steca PA Link1 parallel switch box Generator junction box Electrical load (230 V AC or 115 V AC) 3

Permissible configurations: ATTENTION Risk of malfunction and damage to system components. Only operate stand-alone inverters of the same type and variant together. Master Slave Continuous AC output 12 V DC input voltage PI 500-12 - 450 VA 1 x PI 500-12 900 VA 2 x PI 500-12 1350 VA 3 x PI 500-12 1800 VA 24 V DC input voltage PI 550-24 - 450 VA 1 x PI 550-24 900 VA 2 x PI 550-24 1350 VA 3 x PI 550-24 1800 VA PI 1100-24 - 900 VA 1 x PI 1100-24 1800 VA 2 x PI 1100-24 2700 VA 3 x PI 1100-24 3600 VA 48 V DC input voltage PI 1500-48 - 900 VA 1 x PI 1500-48 1800 VA 2 x PI 1500-48 2700 VA 3 x PI 1500-48 3600 VA The table also applies to the "-60" and "-L60" variants. 1 About these instructions These operating instructions are part of the product. Read these operating instructions carefully prior to installation and use, keep them near the product during its entire service life, and pass them on to any future owner or user of this product. 1.1 Applicability These instructions describe the installation, function, operation and maintenance of the PA Link1 parallel switch box. Further information on operating the battery system is contained in the Steca Solarix PI operating instructions. 1.2 Users These operating instructions are intended for end customers and installers. A technical expert must be consulted in cases of uncertainty. Installation, putting into operation, maintenance, and removal of the PA Link1 shall only be done by trained qualified personnel observing the applicable onsite installation regulations. 4

1.3 Description of symbols 1.3.1 The structure of the warning notices SIGNAL WORD Type, source and consequences of the danger! Measures for avoiding danger 1.3.2 Danger levels in warning notices Danger levels Probability of occurrence Consequences of non-compliance DANGER Imminent threat of danger Death, serious bodily injury WARNING Possible threat of danger Death, serious bodily injury CAUTION Possible threat of danger Minor bodily injury ATTENTION Possible threat of danger Property damage 1.3.3 Notes NOTES Note on easier and safer working habits. Measures for easier and safer working habits 1.3.4 Other symbols and markings in this manual Symbol Meaning Call to action Result of action - Action description List Emphasis on Emphasis on issue at hand issue at hand 1.4 Scope of delivery 1 PA Link1 1 RJ45 cable, red, 0.5 m for Master Solarix PI 1 RJ45 cable, grey, 0.5 m for Solarix PI Slave 1 2 RJ45 cables, grey, 1.0 m for Solarix PI Slave 2 to 3 1 RJ45 cable as connection to StecaLink Master charge controller 1) 1 installation kit with strain relief clamps and screws 1 issue of installation and operating instructions 1) See StecaLink communication instructions at www.steca.com. Firmware update for PA Link1 and StecaLink compatible charge controller might be necessary. 5

2 Safety 2.1 Proper usage The PA Link1 parallel switch box is exclusively intended for use in stationary autonomous power supplies in accordance with these operating instructions. The PA Link1 shall only be operated in a permanently installed and closed condition. Only specialists are permitted to carry out the installation. Any other use is regarded as improper use of the device. Examples of improper use: The PA Link1 parallel switch box must never be connected to the public mains grid or a generator. It is not permitted to operate the PA Link1 parallel switch box without fitted cover of the terminals, without casing, or with a damaged casing. The device may not be installed outdoors. An autonomous power supply system (including PA Link1 parallel switch box) must not be installed, operated or maintained in locations where inflammable gases and vapours can occur, in dusty environments, or in the vicinity of solvents (danger of fire and explosion: ensure that the room is adequately ventilated). The PA Link1 parallel switch box, inverters and batteries must not be used in the vicinity of open fires, flames or sparks. 2.2 Other risks WARNING Battery acid! Acid splashes on skin or clothing should be immediately treated with soap suds and rinsed with plenty of water. If acid splashes into the eyes, immediately rinse with plenty of water and seek medical advice. 2.3 Behaviour in the case of faults DANGER The connected inverters do not appear to function. Parallel switch box, inverter, alternating current cable or battery cable are visibly damaged. If there is smoke emission or fluid penetration. If parts are loose! In these cases immediately disconnect the inverter from the battery and the parallel switch box from the loads. 2.4 Exclusion of liability The manufacturer can neither monitor compliance with this manual nor the conditions and methods during the installation, operation, usage and maintenance of the parallel switch box. Improper installation of the system may result in damage to property and, as a consequence, bodily injury. Therefore, we assume no responsibility or liability for loss, damage or costs which result from, or are in any way related to, incorrect installation, improper operation, or incorrect use and maintenance. Similarly, the manufacturer assumes no responsibility for patent right or other right infringements of third parties caused by usage of this parallel switch box. The manufacturer reserves the right to make changes to the product, technical data or assembly and operating instructions without prior notice. As soon as it is evident that safe operation is no longer possible (e.g. visible damage), immediately disconnect the inverter from the battery and the parallel switch box from the loads. 6

3 Description of the connections 1 Input terminals L Solarix PI slave 1-3 2 Input terminal L Solarix PI master 3 Input terminals N Solarix PI slave 1-3 4 Input terminal N Solarix PI master 5 Output terminals AC OUT consumer 6 Communication Charge controller via StecaLink, 2 RJ45 1) 7 Rotary switch to set address in case of communication via StecaLink 1) 8 Info LED green/info LED yellow 9 Data input Solarix PI master, RJ45 10 Data input Solarix PI slave 1-3, 3 RJ45 11 Cable output AC OUT consumer 12 Cable input Solarix PI AC master 13 Cable input Solarix PI AC slave 1-3 1) See StecaLink communication instructions at www.steca.com. Firmware update for PA Link1 and StecaLink compatible charge controller might be necessary. 4 Installation Example layout of a complete system: A Solar module B Solar charge controller C Battery D Sine wave inverter Steca Solarix PI E Steca PA Link1 parallel switch box F Electric load (230 V AC or 115 V AC) 7

4.1 Mounting 4.1.1 Mounting location Ensure that the mounting location satisfies the following requirements: Mount in a dry, dust-free indoor room. Mount on non-flammable substrate on the wall (concrete) with cable outlet at the bottom. The mounting location must be protected from unauthorized access, especially by small children. Minimum clearance of approx. 10 cm above and below to allow free air circulation. Enough clearance for the type plate to be visible on the installed device. 4.1.2 Mounting the PA Link1 parallel switch box Unscrew 2 screws (1) on the cover (2) of the terminals. Lift the cover upwards. Mark 4 bores according to the dimensional drawing and drill with Ø 6 mm. A 65 mm B 70 mm Insert dowels and screw M5 screws into the three top bores (1). The screw heads must be at a sufficient distance to be able to hang the casing. Hang the casing on the three screws. Screw and tighten one M5 screw through the casing bore (2). 8

4.2 Connection WARNING Danger of explosion from sparking! Danger of electric shock! The parallel switch box may only be connected to the local consumer devices and the inverters by trained personnel and in accordance with the applicable regulations. Connections must always be made in the sequence described below. The cables pre-fitted to the inverter may not be extended and must not be damaged. Only touch-proof voltages (according to SELV/DVC A or appropriate guidelines) may be used at the RJ45 and StecaLink connections. Use only the intended cables and connections. 4.2.1 Connecting the consumers NOTE The terminals and data connections are pictured in detail in the figure on page 20. Or Strip approx. 10 mm of both wire ends of the consumer cable. Introduce the consumer cable through the right-hand strain relief. Connect the consumer cable to a distribution board with a circuit breaker according to the applicable regulations, at the L and N terminals of the AC OUT consumer output. Tightening torque: 1.2 Nm to 1.5 Nm. Install alternating current socket at the terminals of the AC OUT consumer output according to the country-specific regulations. In the event that, due to local regulations or the AC consumers, grounding is required: Carry grounding out following the adjacent diagram (if TN net is permitted). Tighten the screw of the right-hand strain relief. 4.2.2 Connecting the Solarix PI master and slaves ATTENTION Risk of destruction of the device. Never short-circuit the outputs of the stand-alone inverters Solarix PI or the PA Link1. Never connect the StecaLink bus to the RJ45 connections (master, slave) of the stand-alone inverters Solarix PI. Insert cable of the stand-alone inverter Solarix PI master from the right into the bottom part of the second strain relief. Depending on the number of slaves, insert the cables of further standalone inverters Solarix PI into the bottom parts of the still free strain reliefs. Place clamp clips of the strain reliefs onto the bottom parts and loosely fasten each one with two screws. ATTENTION The stand-alone inverters may be damaged in case of incorrect connection. Make sure that all blue cables are connected to N and all brown cables are connected to L. Strip approx. 8 mm of all wire ends. Connect the wires in the parallel switch box in accordance with the terminals labels (see chapter 3 Description of the connections"). Tightening torque: 0.5 Nm. Blue: N terminals Brown: L terminals 9

Tighten the screws of all strain reliefs. Insert the cover of the terminals from the top into the casing s slot, swivel downwards and fasten with two screws. 4.2.3 Connecting the data lines to Solarix PI stand-alone inverters Plug the red data cable s RJ45 plug of the Solarix PI master into the "Solarix Inverter Master" socket. Plug the grey data cables RJ45 plugs of the Solarix PI slaves into the "Solarix Inverter Slave" sockets. 4.2.4 Connecting the StecaLink data line (optional) If necessary, plug RJ45 plug(s) of the StecaLink data cable(s) into the "StecaLink Slave" socket(s) 1). 1) See StecaLink communication instructions at www.steca.com. Firmware update for PA Link1 and StecaLink compatible charge controller might be necessary. NOTE Check that the locking mechanisms of the RJ45 plugs are engaged. 4.2.5 Connecting the inverter to the battery WARNING Danger of explosion from sparking! Danger of electric shock! Before connecting the inverters, make sure that no load is switched on and all the inverter rotary switches are set at "Off". The cables pre-fitted to the inverters must not be extended. Switch all the inverter rotary switches to the "Off" setting Connect the inverters to the battery in accordance with the Steca Solarix PI operating instructions. The green Info LED on the PA Link1 illuminates. The installation of the system is now complete. 4.3 Function test Turn rotary switches on all inverters to "Off". Turn rotary switch on master to "All on". The system is working correctly when the LEDs on all inverters light up or blink green. If the LED of an inverter does not light up or blink green, proceed as described in the section "Fault diagnosis and troubleshooting". To end the function test, switch the master rotary switch to the "Off" setting. 10

4.4 Making changes to the system Master and slave(s) are identical inverters. Their function in the system is determined by the connection to the parallel box: Master: Slave(s): "Solarix Inverter Master" data input and "Master L/N" voltage input "Solarix Inverter Slave" data input and "Slave L/N" voltage input WARNING Danger of explosion from sparking! Danger of electric shock! Plugs and cables must not be disconnected when voltage is present! Before pulling out plugs or disconnecting cables make sure that no loads are connected and the inverters are disconnected from the battery. The cables pre-fitted to the inverters must not be extended. 4.4.1 Replacing inverters Proceed as follows when replacing the master or a slave: Make sure that no loads are connected and the inverters are disconnected from the battery. Pull out the RJ45 plug at the relevant data input. Open the cover on the parallel switch box. Disconnect the input of the relevant master or slave at the parallel switch box. Connect the new master or slave, as described in Section 4.2. 4.4.2 Using a slave as the master If the master fails, a slave can be used as the new master. Make sure that no loads are connected and the inverters are disconnected from the battery. Pull off RJ45 plugs of all data inputs. Open the cover on the parallel switch box. Disconnect all the cables at the parallel switch box. Connect the reconfigurated system as described in Section 4.2. 5 Operation In parallel operation the power supply is regulated by the rotary switch on the master, see the Steca Solarix PI operating instructions. The rotary switches at the slaves do not have any function. However, they must be in the Off position because otherwise the slaves may eventually become operational unintentionally. 5.1 Rotary switch settings Master Slave(s) Inverter state Off Off Master and slaves switched off Standby Off Load-dependent response of master and slaves, where applicable On Off Master always switched on, slaves switched on as required All On Off Master and slaves always switched on This setting is recommended for high performance devices (at the performance limit), e.g. for operating a washing machine 11

6 Care, maintenance and service The device is maintenance-free. If functional faults occur, please consult your dealer and present the payment receipt/invoice. Before cleaning, switch off all loads and switch off the master via the rotary switch (setting "Off"). Clean casing surface periodically using a slightly moistened cloth. Do not use solvents. 7 Technical data PA Link1 parallel switch box Operating temperature 0 C +50 C, under continuous load Storage temperature -20 C +70 C Humidity 0 % 95 % relative humidity, non-condensing Maximum altitude 2000 m above sea level Degree of protection IP 20, use in dry environment Dimensions (W x H x D) 196 mm x 106 mm x 52 mm Weight 0.8 kg Connectable devices Maximum of 4 stand-alone inverters of the same type and variant: Solarix PI 500-12 (-60/-L60) Solarix PI 550-24 (-60/-L60) Solarix PI 1100-24 (-60/-L60) Solarix PI 1500-48 (-60/-L60) Continuous output at AC OUT consumer output, see table on page 17 Indicators Green Info LED: Solarix PI is connected Yellow Info LED: for communication with StecaLink 2) Connections 4 data inputs RJ45 for Solarix PI 4 230 V AC or 115 V AC 1) voltage inputs for Solarix PI 230 V AC or 115 V AC 1) consumer output 2 RJ45 connections for StecaLink 2) Connection data, AC OUT terminals Conductor cross-section, Minimum of 0.5 mm 2 to maximum of 16 mm 2 rigid/flexible Conductor cross-section, Minimum of AWG 20 to maximum of AWG 6 AWG Connection data, master/slave terminals Conductor cross-section, Maximum of 4.0 mm 2 solid (rigid) Conductor cross-section, Maximum of 2.5 mm 2 stranded (flexible) Conductor cross-section, Maximum of 2.5 mm 2 stranded (with ferule) 1) The voltage corresponds to the output voltage of the stand-alone inverters. 2) See StecaLink communication instructions at www.steca.com. Firmware update for PA Link1 and StecaLink compatible charge controller might be necessary. 12

8 Fault diagnosis and troubleshooting Fault diagnosis and troubleshooting of the individual inverter is described in the Steca Solarix PI operating instructions. Fault Cause Remedy LED on slave does not light up Attention Danger of damage to the inverter. LED on master does not light up The system does not work, although the master and slave(s) are in working order LEDs on inverters signal a malfunction The green Info LED on the PA Link1 is not illuminated Data cable not inserted properly Data cable defective Slave defective Disconnect the battery and the power cable from the slave before working on the data cable. Then reconnect battery cable. Connect the power cable only after completion of all work. Ensure that the data cable is inserted properly. If LED does not light up, replace the data cable. If LED does not light up, replace the slave. Master defective Replace master, e.g. rewire system with a previous slave as master Parallel switch Replace parallel switch box box defective Wiring fault No data connection to Solarix PI Check the wiring Check RJ45 wiring between PA Link1 and Solarix PI 9 Commercial and legal guarantee conditions Find the warranty terms on internet at: www.steca.com/pv-off-grid/warranties 13

10 Contact Any further claims against the seller based on this legal guarantee obligation, in particular claims for damages due to lost profit, loss-of-use or indirect damages are excluded, unless liability is obligatory by law. They will help you with all issues you may have. Steca Elektronik GmbH Mammostrasse 1 87700 Memmingen Germany Fon +49 8331 8558 833 Fax +49 8331 8558 132 E-Mail service@stecasolar.com Internet www.steca.com PA Link1 parallel switch box Type... Series number... Dealer Company... Contact person... Street... Postcode... Town... Telephone number... Email... Comments 14