Breaker Panel Technical Practice NPDRP1114

Similar documents
Westell. Breaker Panel Technical Practice NPDRP1114

28-Position 23 Rack Mounting Model RM23-20X

Specifications, Installation, and Operating Instructions

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Westell DBMA Position DS3 Mounting Assembly

VirtualEdge VEUP-30 Universal Panel, with 3 LGX-Type Positions and 12 Keystone Coupler Positions

VirtualEdge VEUP-BNC6P DS3 Protection Panel

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Power Supply (48Vdc, 2.5A)

SVP110 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Installing the Cisco MDS 9020 Fabric Switch

Junos WebApp Secure 5.0 Hardware Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

to 48V DC Power Supply

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

User s Guide. POWERVAR Single Phase Power Conditioners

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Power Supply Installation

Installation Instructions & User Manual

SVP48 SURGE VOLTAGE PROTECTOR INSTRUCTION MANUAL

Installation and Operation

VirtualEdge VELGX 90 Media Panel, with Nine LGX Type Positions, Front Tray, and Top Cover

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Always "On" UPS Systems Inc. USER MANUAL

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

OPERATING MANUAL PDUAC3U SERIES AC POWER DISTRIBUTION UNITS

iconverter 2-Module Power Chassis

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors

Liebert MicroPOD 230V

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

PANEL MOUNT INTERCOMS

Surge Protective Devices. STV25K Series. Instruction Manual

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

UPS READY POWER DISTRIBUTION ASSEMBLY

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

CMSA-100 Manual. Cinema Media Server Automation

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

VRp Three-Phase Precision AC Voltage Regulator

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Titan Media Cart. Installation and Operation Manual

Rackmount Keyboard Installation Instructions. Revision A A-0000

USER MANUAL. MODEL 56X Series 564, 566, 568, 562. Hub Surge Protectors

Basketball Shot Clock Set LX2180 Manual

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Site Preparation CHAPTER

EATON Transformer Module

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

C-POWER AC AUTOMATIC CONTROL

810D Series FAA L-810 Double Obstruction Light Installation Manual

PACSystems RX7i IC698CHS009/119

VIP-480AL IP One-Way Horn

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTALLATION INSTRUCTIONS FOR

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Installing the Cisco SFS 3504 Server Switch

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

USER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Square D Homeline Load Centers and Circuit Breakers. Engineered for value

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Section 4 Ground-Fault Protection Devices

The PST-6. Owners Manual 1

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

DCM Digital Control Modules

F O R U M S E R I E S

Ethernet Test Access Panel (ETAP) User Manual

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Model 720 Electromechanical Hour Meter

Surge Protective Devices Installation, Operation and Maintenance Manual. ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

PS8 - II. Professional Power Sequencer. User s Manual

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

MPF-1, Mains Power Filter User Manual

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

Transcription:

030-000218 REV E 1114-03E January 30, 2013 Westell Breaker Panel Technical Practice NPDRP1114 FEATURES DIN rail panel accepts up to 6 DIN rail devices (one surge and 5 breakers) Specific configuration of breakers can be specified at time of ordering This panel typically operates at 60 Amps of output current per panel Single 1.75 mounting height (single panel space) Steel metal chassis. Mounting brackets are supplied for 1 & 1-3/4 spacing and are universal for 19 and 23 racks, with flush mounting options Ground bonding terminations provided that will accept two hole lugs Breakers and surge suppressors are ordered separately UL Recognized

1. GENERAL DESCRIPTION 1.1. The NPDRP1114 Breaker Panel provides up to 3 circuits for the distribution of AC power to equipment. Each of the 3 circuits is protected by a breaker located on the panel's faceplate, as well the bus is protected by a overvoltage surge protector. 1.2. The power is distributed to the load side equipment through breakers. Each circuit is available for installer connection at the rear of the panel. 1.3. These Breaker Panels are made from steel that s painted off-white. This single rack height panel is shipped with universal brackets (1 & 1-3/4 spacing) that will fit both 19" and 23" wide racks and use only one 1.75" panel space. 2. APPLICATION 2.1. The NPDRP1114 Breaker Panels are designed to be used in the distribution of AC power. They are rack mount panels that can provide AC power to 3 different circuits. Breakers and surge suppressors are ordered separately, consult factory. 2.2 The NPDRP family breaker panels are suitable for installation as part of a Common Bonding Network (CBN, bonded to the equipment rack rails via the rack mounting screws). As well, this family of breaker panels is suitable for restricted access locations in Network Telecommunications Facilities and OSP. 3. INSTALLATION Please read completely before beginning. WARNING: Installation and service should only be performed by an experienced Installer (service person) familiar with AC power distribution systems. An electrician is recommended when working with AC circuits. This equipment is intended to be installed in RESTRICTED ACCESS LOCATIONS by TRAINED SERVICE PERSONNEL ONLY. 3.1. Unpack and inspect the Breaker Panel for possible damage incurred during shipping. If damage is found, file a claim immediately with the courier, and notify the Customer Service Department. 3.2. Once the panel is unpacked, verify that there are three mounting brackets. The bracket with the vertical slot is used on both 1 and 1-3/4 spacing. There will be two brackets with horizontal slots, these will fit 1 or 1-3/4 spacing. All three brackets are universal for 19 and 23 rack mount spacing (see figure 3.2.1) and can be mounted so the panel can be installed for a flush mounting at front or at rear. Adjust the position and orientation of the correct mounting brackets on the breaker panel, such that it will fit the rack you wish to mount the panel in. 3.3. Mount the panel on the equipment rack using the thread forming #12-24 rack mounting screws and tooth lock washers provided. WARNING: For safety reasons all wiring should be done with the power source removed (when possible). 19" Mounting Position Figure 3.2.1 23" Mounting Position 3.4. CHASSIS GROUND; For safety reasons, the chassis should be electrically connected to the rack ground. From step 3.3. the panel should already be ground to the rack via the #12-24 thread forming rack screws and outside tooth lock washers. In addition to grounding via the mounting brackets, it is recommended you ground the chassis using a ground cable and the two #10 Studs (on 5/8 centers) and locks on back of chassis (#10 bolt torque; 25 IN-LB). Consult your internal practice or local electric code for AWG sizes. Grounding lugs are not included. 2

4. SPECIFICATIONS 4.1. Voltage 120 VAC 4.2. Dimensions 1¾ H, 17 W, 3 D (excluding brackets) 4.3. Rack Mounting 19 and 23 Racks for 1 or 1-3/4 Panel Spaces 4.4. Weight Appx 3 Lbs 4.5. Operating Temp. -40 to +65 C (-40 to +149 F) 4.6. Color Off White Ordering Options: NPDRP1114 BR15A240QOU BR30A240QOU Blank Din Rail Panel with cover and brackets. Breaker, 15A, 240VAC, 1-Pole Breaker, 30A, 240VAC, 1-Pole Compatible Breakers: Square D QOU Series Compatible Surge Suppressors: Transector I 2 R SA-120-50 Series TVS AC Data DRM-120-90 Series BR60A240QOU-2 BRTVS120VAC BRTVS240VAC Breaker, 60A, 240VAC, 2-Pole Transient voltage suppressor for 120VAC Transient voltage suppressor for 240VAC 5. TECHNICAL SERVICES 5.1 If technical or customer assistance is required, contact Westell by calling or using one of the following options: Voice: (800) 377-8766 email: global_support@westell.com For additional information about Westell, visit the Westell World Wide Web site at http://www.westell.com. 6. WARRANTY & REPAIRS 6.1 Westell warrants this product to be free of defects at the time of shipment. Westell also warrants this product to be fully functional for the time period specified by the terms and conditions governing the sale of the product. Any attempt to repair or modify the equipment by anyone other than an authorized Westell representative will void the warranty. 6.2 Westell will repair or replace any defective Westell equipment without cost during the warranty period if the unit is defective for any reason other than abuse, improper use, or improper installation. To return defective equipment, first request a Return Material Authorization (RMA) number from Westell by calling or emailing (Customer Service) at the address below. Once an RMA number is obtained, return the defective unit (freight prepaid), along with a brief problem description, to the address we will provide to you when you contact us. email: rgmdept@westell.com Voice: (800) 377-8766 Replacements will be shipped in the fastest manner consistent with the urgency of the situation. Westell will continue to repair or replace faulty equipment beyond the warranty period for a nominal charge. Contact Westell for details. 3

4 Noran Tel

1 2 3 4 5 SURGE PROTECTOR DANGER HIGH VOLTAGE Personnel Only Certified Risk of Electrical Shock Noran Tel 5