imag-series Flanged Magmeter

Similar documents
FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

MAG. ECO FLO imag Series NSF FEATURES

imag 4700 Series FLANGED MAGMETER

imag 4700 Series FLANGED MAGMETER

AG3000 SERIES FLANGED MAGMETER

AG3000 SERIES FLANGED MAGMETER

imag ISO 9001:2008 Municipal/Industrial Magmeter Instructions NSF Flow Meters & Controls ECO FLOMAG imag Series 9 001:2008 ISO CERTIFIED COMPANY

MAG. imag ISO. ECO FLO imag Series. Municipal/Industrial Magmeter Instructions NSF. Flow Meters & Controls ISO CERTIFIED COMPANY. o vi n g P a.

imag 4700 Municipal/Industrial Magmeter Instructions PROUDLY MADE IN THE USA

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Series DMHF Heat Meter

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

... f l o w measurement & control...

Modbus. Interface. Description ISO 9001:2008

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Signet 2552 Metal Magmeter Flow Sensors

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Ultrasonic Heat Flow Meters

SENSOR MUT2200EL. Electromagnetic flowmeter. The electromagnetic flowmeter for all applications DS100-1-USA

Flow Measurement SITRANS F M

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

F-1000 DIGITAL PADDLEWHEEL FLOWMETER

Clamp-On Transit Time Ultrasonic Flow Meters

Applications. Features & Benefits ULTRASONIC WATER METER

WaterMaster Select Electromagnetic flowmeter. The perfect fit for water industry applications

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

FT400-Series RATE/TOTAL INDICATOR INSTRUCTIONS FT415 FT :2008 ISO CERTIFIED COMPANY FT400-SERIES RATE TOTAL/INDICATOR INSTRUCTIONS

B.M LIMENA (PD)

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

Flow Measurement SITRANS F US Clamp-on

IFB NO. ASPA A.WATER Purchase and Delivery of Variable Frequency Drives (VFDs) and Mag Meters. TECHNICAL SPECIFICATIONS FOR VFDs AND MAG METERS

Flow Measurement SITRANS F M

CONVERTER MC608 A/B/R/P/I. The Hybrid electronic converter for all applications DS300-1-USA

UTM10 Series Ultrasonic Transit-time Flowmeters

OPERATING INSTRUCTIONS

Model Sono-Trak General Specification

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IDS-676 DL

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

Sensor Wafer MUT 1000 EL DS120-1-ENG

Flow Measurement SITRANS F US Inline

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Portable Dual Frequency Doppler Flowmeter

Flow Measurement SITRANS F US Inline

DMTFP Portable Ultrasonic Flow Meters

DCT7088 Portable Digital Correlation Transit Time Flowmeter

JVMG* *NSF 61/Annex G Certification and Compliance with State Codes does not apply to JVMG Models

OPERATING MANUAL FOR MASTERMAG

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Level and Flow Measurement. Flow Pulse

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

SITRANS F flowmeters SITRANS F US

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Signet 9900 Transmitter

Flow VA 500/

Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Spectrum 175D. meter performance with no maintenance.

Local Model. Remote Model. FPD1000D-BAT Battery Powered Display Local and Remote Models

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Family of Water Cut Analyzers

OPTISONIC 6400 Technical Datasheet

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog

Level and Flow Measurement. Flow Pulse

BATCH CONTROLLER. Features. Input Options F130. DC powered with 7 yr battery or mains option. Overview

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

DREXELBROOK. Datasheet Universal IV In-Line Water Cut Meter. with Spool Piece Mounting USE THE BEST APPLICATIONS. Eliminate Routine Maintenance

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Spectrum 130D. Warranty 5 Yr. Materials & Workmanship 5 Yr. OER Register Standards AWWA C NSF-61/372

Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Conductivity Transmitters

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

Flow Measurement SITRANS F US Clamp-on

Electro-Magnetic Flowmeters Converters

Induction Flow Meter. AcquaMAG. Installation and Operating Manual

THE TECHNOLOGY BEHIND THE MEASUREMENT

Model RFM. Model RFM. Materials and Specifications. Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" Features 1" RFM 50 2" RFM 160

NEW BenchPro Series Multi-Purpose Digital Bench Scale

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

The Emflux Flow Meter Family

Simplified information where and how you want it.

Standard Circulating Pumps

MULTI PARAMETER WATER QUALITY SENSORS

Universal IV Water Cut Meter

AllPro Hazardous/Corrosive Area Fluorescent

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

MAX FLUID TEMPERATURE

MAGFLO MAG 5100 W Benefits Application Flow Measurement Mode of operation Function Integration

Transcription:

s Flow Meters & Controls imag-series o M o vi n g P a r t N FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved (3 only) IP68 rated 9001:2008 ISO CERTIFIED COMPANY THE RIGHT METER FOR Water & wastewater Municipal Treatment plants Pump stations Packaged plants Filtration systems Reclaimed Water PROUDLY MADE IN THE USA

GENERAL INFORMATION The imag-series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in municipal or industrial water, waste and reclaimed water, pump stations and packaged plant applications. The imag has no moving parts and electrodes are designed to discourage fouling. This magmeter requires no maintenance in applications where debris would impede mechanical meters. There are no parts to wear out. Minimal straight pipe requirements allow imag-series meters to be used in piping configurations where there is little space between the meter and an elbow. imag-series meters are rated IP68 for applications where the meter may be under water up to a depth of 10 feet (3 meters) for prolonged periods of time. Rate and total indication are standard. Rate and total units and pulse output are settable via the front panel touch key pad by the user. Bi-directional flow is standard. Forward, reverse and net flow can be read from the display. If forward and reverse flow data needs to be sent to another device, Modbus output is required. The imag 3600 and 4600 can be externally powered with 9-36 Vdc at 30 ma average. The 4600 is also available in a battery powered version. The standard 20-foot (6 meter) cable also provides outputs for use with a variety of Seametrics and other displays and controls for remote reading, data logging and telemetry applications. 4-20mA passive current loop and high frequency outputs are optional on the externally powered models. Pulse output is standard on the battery powered model. The imag 3600 remote display meter can be supplied with an optional internal AC power supply. FEATURES Configuration Port (For Factory Use Only) Multifunction Display Light Sensor Keypad Protective Cover with Magnetic Seal

FEATURES Continued Rate and total indicator Security seal & cross-drilled screws (2) for tamper-evidence Power and Output cable port access, tamper-sealed Configuration Port (For Factory Use Only) Powder-coated ductile cast iron body & electronics housing Equalization lug Glass filled molded plastic liner 316SS electrodes (Inside) Flanges, 150 lb. ANSI pattern imag 4600-300 Rate and total indicator with protective cover and keypad sensors Powder-coated ductile cast iron electronics housing Security seal & cross-drilled screws (2) for tamper-evidence Power and Output cable port access Configuration Port (For Factory Use Only) Flanges, 150 lb. ANSI pattern Equalization lug 316SS electrodes (Inside) Santoprene/Polypropylene Liner Welded steel epoxy-coated flow tube imag 3600-0400 (Remote indicator) imag 4600-0400

SPECIFICATIONS* Pipe Sizes 3,4, 6, 8, 10, 12 Flanges Pressure 150 lb. ANSI pattern 150 psi (10.3 bar) working pressure Temperature Operating 10 to 130 F (-12 to 54 C) Accuracy Low Flow Cutoff Storage -40 to 158 F (-40 to 70 C) +/- 1% of reading +/- 0.025% of full-scale flow from low flow cutoff to maximum flow rate of 10 m/sec 0.5% of maximum flow rate Materials Body (3 Only) Ductile cast iron, powder-coated Body (4-12 ) Liner (3 Only) Liner (4-12 ) Electronics Housing Electrodes O-ring (3 Only) Welded steel, epoxy-coated Noryl Santoprene/Polypropylene Ductile cast iron, powder-coated 316 stainless steel EPDM Display Type 128x64 dot-matrix LCD Digits 5 Digit Rate 8 Digit Total Units Please Note: All imag meters are factory set for gallons per minute (GPM) rate and gallons total. If other units are required, they can be programmed in the field. Bi-directional 1 Rate Volume Units Rate Time Units Total Volume Units Gallons Liters Cubic Feet Cubic Meters Million Gallons Mega Liters Imperial Gallons Million Imperial Gallons Barrels (42 gallon) Forward Total, Reverse Total, Net Total Second Minute Hour Day Power DC Power 9-36 Vdc @ 250 ma max, 30 ma average Pulse Frequency Output AC Power 2 85-264Vac, 50/60Hz, 0.12A Battery 3 Signal Pulse Rates Two lithium 3.6V D batteries, replaceable. Current sinking pulse, isolated, 36 Vdc at 10 ma max Gallons Gallons x 1000 Million Gallons Liters Kilo Liters Mega Liters Cubic Meters Barrels (42 gallon) Cubic Meters x 1000 Cubic Feet Cubic Feet x 1000 Million Cubic Feet Imperial Gallons Imperial Gallons x 1000 Million Imperial Gallons User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5ms, 200 pulses/sec max Options 4-20mA Current Loop Isolated, passive, 6-36Vdc, error less than +/- 0.1% of pulse/frequency output, HART compliant Digital Output Serial Communications Isolated, open collector, 36Vdc @ 10mA max., frequency output at max. flow selectable as 0.5, 1,2, 5 or 10kHz Isolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus RTU protocol Cable Control Cable Six-conductor water-blocked cable, polyurethane jacket, 20ft (6m) standard length for power, pulse frequency or optional outputs (optional lengths up to 100 available) Conductivity Empty Pipe Detection Remote Display Cable (imag 3600) 33ft (10m) standard length (optional lengths up to 100 available) >20 microsiemens/cm Hardware/software, conductivity-based Regulatory (EN 61326) pending, NSF-61 on 3 ONLY Environmental IP68 to 10ft (3m) depth *Specifications subject to change. Please consult our website for the most current data (www.seametrics.com). 1 If forward and reverse flow data needs to be sent to another device, either the -ADDX, -DDDX or Modbus output is required. 2 imag3600 only, imag4600 requires external AC power supply 3 imag4600 only

DIMENSIONS imag4600-0300 Shown H T Cable Exit (Metal Flange) ID L (Including Rubber Gaskets) imag3600 Remote Shown.20 Dia. 5.62 Cable Exit 2.5 3 5.27 4.38 imag4600-0400 to 1200 Shown H T (Metal Flange) Cable Exit ID L (Including Rubber Gaskets)

imag Dimensions imag Meter Size 3 4 6 8 10 12 inch L mm 12.0 305 10.24 260 12.27 312 14.24 362 18.18 462 19.68 500 inch H mm 6.80 173 8.12 206 9.22 234 10.22 260 11.22 285 12.28 312 inch T mm.68 17.3.62 20.9.69 23.3.69 23.3.69 23.3.81 20.6 inch ID mm 2.60 66.04 3.12 79.25 5.05 128.27 6.44 163.58 8.61 218.69 10.55 267.97 Shipping Weight pounds Kg 41 19 35 16 50 23 72 33 128 58 170 78 Flanges Standard ANSI 150 lb. drilling pattern Cable 1 lb. FLOW RANGE (3-12 ) Pipe Size (Inches in diameter) Max Flow Rate (Gallons/Minute) Cut-off (min) Flow Rate (Gallons/Minute) Max Flow Rate (Liters/Second) Cut-off (min) Flow Rate (Liters/Second) Max Flow Velocity (Meters/Second) 5 3 4 6 8 10 12 723 1285 2891 5140 8031 11565 3.62 6.43 14.46 25.70 40.15 57.82 46 81 182 324 507 730 0.23 0.41 0.91 1.62 2.54 3.65 10 10 10 10 10 10 imag Accuracy 4 Accuracy (%) 3 2 1 0 0 2 4 6 8 10 (m/s) 0 0 5 10 15 20 25 30 5 10 15 20 25 30 33 (ft/s) Flow Velocity

OUTPUT CAPABILITIES Remote Data Logger Compatible Remote Data Logger imag STRAIGHT PIPE RECOMMENDATIONS (X = pipe diameter) 2X imag - 300 1X Minimal straight pipe required between elbows. For other piping configurations, consult factory. FLOW (X = pipe diameter) imag - 400 to 1200 2X 1X FLOW

HOW TO ORDER imag 3600-1 2 3 4 5 imag 4600 - Size Flange/Fitting imag 3600 (Remote Indicator) Options imag 3600 Power and Communications Power/Output Cable 1 2 3 4 5 Sensor Cable -0300 3 -F1 ANSI 150# -ADDX AC Power, 2 Digital Outputs -000 No Cable -010 10 meter (33 ) 1-0400 4 -ADLX AC Power, Current Loop, Digital Output -006 6 meter (20 ) 1-020 20 meter (66 ) -0600 6 -APLX AC Power, Pulse, Current Loop -010 10 meter (33 ) -030 30 meter (100 ) -0800 8 -APXX AC Power, 1 Pulse Output -020 20 meter (66 ) -1000 10 -ASSX AC Power, Modbus -030 30 meter (100 ) -1200 12 -APHX -DDDX -DDLX AC Power, Pulse, HART DC Power, 2 Digital Outputs DC Power, Current Loop, Digital Output -045 45 meter (150 ) -060 60 meter (200 ) -DPLX DC Power, Pulse, Current Loop -DPXX DC Power, 1 Pulse Output -DSSX DC Power, Modbus -DPHX DC Power, Pulse, HART Size imag 4600 (Internal Indicator) Options Flange/Fitting imag 4600 Power and Communications Power/Output Cable 1 2 3 4-0300 3 -F1 ANSI 150# -DDDX DC Power, 2 Digital Outputs 3-000 No Cable 4-0400 4 -DDLX DC Power, Current Loop, Digital Output 3-006 6 meter (20 ) 1-0600 6 -DPLX DC Power, Pulse, Current Loop 3-010 10 meter (33 ) -0800 8 -DPXX DC Power, 1 Pulse Output 3-020 20 meter (66 ) -1000 10 -DSSX DC Power, Modbus 3-030 30 meter (100 ) -1200 12 -DPHX DC Power, Pulse, HART 3-045 45 meter (150 ) -BPXX Battery Power, 1 Pulse Output 3-060 60 meter (200 ) 1 6 meter (20 ) power cable (imag 3600 or imag 4600) and 9 meter (30 ) sensor cable (imag 3600 only) are included at no additional charge. 2 All imag meters are factory set for gallons per minute (GPM) rate and gallons total. If other units are required, they can be programmed in the field. 3 If one of these options is seleceted, one of the power/output cable options is required. 4 Battery power configuration only. Seametrics Incorporated 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 www.seametrics.com LT-103200r1.4 20161025 10/25/16