Flow Meters & Controls MAG ECO FLO imag Series M o vi n g P s N o rt w U NSF o n Easy setup Minimal straight pipe Mounted or remote rate & total 4-2mA output available Tamper-evident seal NSF-61 approved IP68 rated ISO 9 1 : 2 8 CERTIFIED COMPANY F l o b Certified to NSF/ANSI 61-G FEATURES a st r u ct e d THE RIGHT METER FOR Water & wastewater Municipalities Treatment plants Pump stations Cooling towers Packaged plants Filtration systems PROUDLY MADE IN THE USA
GENERAL INFORMATION The imag-series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in municipal or industrial water, wastewater, pump stations and packaged plant applications. The imag has no moving parts with electrodes designed to discourage fouling. This magmeter requires much less frequent maintenance in applications where debris would impede mechanical meters. There is no rotor to stop turning or bearings to wear out. Minimal straight pipe requirements allow imag-series meters to be used in piping configurations where there is little space between the meter and an elbow. imag-series meters are rated IP68 for applications where the meter may be under water up to a depth of 1 feet (3 meters) for prolonged periods of time. Rate and total indication are standard. Units are customerselectable. Settings (units, pulse output, etc.) are user settable via front panel touch key pad. The imag can be externally powered with 9-36 Vdc at 3 ma. The standard 2-foot (6 meter) cable also provides outputs for use with a variety of Seametrics and other displays and controls for remote reading, data logging and telemetry applications. 4-2mA passive current loop and high frequency outputs are optional. The imag 36 remote display meter can be supplied with an optional internal AC power supply. FEATURES Multifunction Display Light Sensor Keypad Protective Cover with Magnetic Seal
FEATURES Continued Rate and total indicator Security seal & cross-drilled screws (2) for tamper-evidence Power/Output cable port access, tamper-sealed Powder-coated ductile cast iron body & electronics housing Glass filled molded plastic liner 316SS electrodes Flanges, 15 lb. ANSI pattern Equalization lug imag 46-3 Rate and total indicator with protective cover and keypad sensors Powder-coated ductile cast iron electronics housing Security seal & cross-drilled screws (2) for tamper-evidence Power/Output cable port access Flanges, 15 lb. ANSI pattern Equalization lug 316SS electrodes Santoprene/Polypropylene Liner Welded steel epoxy-coated flow tube imag 36-4 (Remote indicator) imag 46-4
SPECIFICATIONS* Pipe Sizes 3,4, 6, 8, 1,12 Flanges Pressure 15 lb. ANSI pattern 15 psi (1.3 bar) working pressure Temperature Operating 1 to 13 F (-12 to 54 C) Accuracy Low Flow Cutoff Storage -4 to 158 F (-4 to 7 C) +/- 1% of reading +/-.4% of full-scale flow from low flow cutoff to maximum flow rate of 1 m/sec.5% of maximum flow rate Materials Body (3 Only) Ductile cast iron, powder-coated w/nsf61 listed epoxy powder Body (4-12 ) Liner (3 Only) Liner (4-12 ) Electronics Housing Electrodes O-ring (3 Only) Welded steel, epoxy-coated Noryl Santoprene/Polypropylene Ductile cast iron, powder-coated 316 stainless steel EPDM Display Type 128x64 dot-matrix LCD Digits 5 Digit Rate 8 Digit Total Units Rate Volume Units Rate Time Units Total Volume Units Gallons Liters Cubic Feet Cubic Meters Million Gallons Mega Liters Imperial Gallons Million Imperial Gallons Second Minute Hour Day Gallons Gallons x 1 Million Gallons Liters Liters x 1 Mega Liters Cubic Meters Cubic Meters x 1 Cubic Feet Cubic Feet x 1 Imperial Gallons Imperial Gallons x 1 Million Imperial Gallons Power DC Power 9-36 Vdc @ 25 ma max, 3 ma average Telemetry Output 2 Pulse Frequency Output *Specifications subject to change. Please consult our website for the most current data (www.seametrics.com). 1 imag36 only, imag46 requires external AC power supply 2 Available in 214 AC Power 1 85-264Vac, 5/6Hz,.12A Signal Pulse Rates 3.3V asynchronous receive and transmit (UART) signals, ASCII command-response protocol Current sinking pulse, isolated, 36 Vdc at 1 ma max User-settable volume units/pulse. Pulse width is one-half of pulse period, 2 pulses/sec max Options 4-2mA Current Loop Isolated, passive, 6-36Vdc, +/-.1% of pulse/frequency output HART compliant 2 Digital Output Relay Output Serial Communications 2 Isolated, open collector, 36Vdc @ 1mA max., frequency output up to 1kHz Solid state relay, normally open, non-polarized, 28Vac/4Vdc @.5A max, 33Hz max Isolated, asynchronous serial RS485 or RS232, Modbus RTU protocol Cable Control Cable Six-conductor water-blocked cable, polyurethane jacket, 2ft (6m) standard length for power, pulse frequency or optional outputs Conductivity Empty Pipe Detection Remote Display Cable (imag 36) 3ft (9m) standard length (may be shortened). Additional cable can be ordered and attached with the use of a junction box up to 1ft (3m) total >2 microsiemens/cm Hardware/software, conductivity-based Regulatory (EN 61326) pending, NSF-61 Environmental IP68 to 1ft (3m) depth
DIMENSIONS imag - 3 Shown H T (Metal Flange) ID L imag - 4 to 12 Shown H T (Metal Flange) FLOW ID L (Including Rubber Gaskets)
imag Dimensions imag Meter Size 3 4 6 8 1 12 inch L mm 12. 35 1.24 26 12.27 312 14.24 362 18.18 462 19.68 5 inch H mm 6.8 173 8.12 26 9.22 234 1.22 26 11.22 285 12.28 312 inch T mm.68 17.3.62 2.9.69 23.3.69 23.3.69 23.3.81 2.6 inch ID mm 2.6 66.4 3.12 79.25 5.5 128.27 6.44 163.58 8.61 218.69 1.55 267.97 Shipping Weight pounds Kg 41 19 35 16 5 23 72 33 128 58 17 78 Flanges Standard ANSI 15 lb. drilling pattern Cable 1 lb. FLOW RANGE (3-12 ) Pipe Size (Inches in diameter) Max Flow Velocity (Meters/Second) Max Flow Rate (Gallons/Minute) Max Flow Rate (Liters/Second) Turn Down Flow Rate (Gallons/Minute) Turn Down Flow Rate (Liters/Second) 3 4 6 8 1 12 1 1 1 1 1 1 723 1285 2891 514 831 11565 46 81 182 324 57 73 3.62 6.43 14.46 25.7 4.15 57.82.23.41.91 1.62 2.54 3.65 5 imag Accuracy 4 Accuracy (%) 3 2 1 2 4 6 8 1 2 4 6 8 1 (m/s) 5 1 15 2 25 3 5 1 15 2 25 3 33 (ft/s) Flow Velocity
OUTPUT CAPABILITIES Remote Data Logger Compatible *Telemetry (Available Soon) Telemetry Remote Data Logger imag imag STRAIGHT PIPE RECOMMENDATIONS (X = pipe diameter) 2X imag - 3 1X Minimal straight pipe required between elbows. For other piping configurations, consult factory. FLOW (X = pipe diameter) imag - 4 to 12 2X 1X FLOW
MAG ECO FLO imag Series HOW TO ORDER Example: imag36-4-f1-aplx-6 1 1 Series 2 Remote Indicator imag 36 Internal Indicator imag 46 2 Size 3 Flange/Fitting 3 Inch (3 ) 3 4 Inch (4 ) 4 6 Inch (6 ) 6 8 Inch (8 ) 8 1 Inch (1 ) 1 12 Inch (12 ) 12 ANSI 15# F1 Metric F2 3 4 4 5 6 Power 5 Communication AC Power* A DC Power D Pulse Output PTX 4-2mA Current Loop (HART available in 214) PLX Digital Out DDX Relay Out RRX (Modbus) Serial Communication Available 214 SSX Telemetry Available 214 T 6 Cable Length 2ft (6m) 6 3ft (1m) 1 *imag 36 only CONTACT YOUR SUPPLIER 11 South Service Road, Unit 114 Stoney Creek, ON L8E C5 TEL: 95-842-5664 FAX: 95-643-73 Email: sales@veronics.com Website: www.veronics.com S e am e trics In c o r po r at e d 1 9 2 6 7 2 n d A ven ue South Ken t, Washi n g ton 9832 USA ( P ) 2 5 3.8 7 2. 2 8 4 ( F ) 2 5 3. 8 7 2. 2 8 5 1. 8. 975. 8153 w w w. seametr i cs. com LT-132-12213 1/22/13