AquaShock ph Meter K

Similar documents
Datalogging ph Meter

Mini Environmental Quality Meter

Datalogging Conductivity/ TDS Meter. Instruction Manual

4-Channel Thermometer

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Torque Meter. Instruction Manual

Mini Environmental Quality Meter

Light Meter (Foot Candles)

RH/Temperature SD Card Datalogger. Instruction Manual

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

Large Display Salinity & Conductivity Pens &

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Advanced Datalogging Thermometer. Instruction Manual

4-Channel Datalogging Thermometer

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Anemometer SD Card Datalogger. Instruction Manual

Visible Light SD Card Datalogger

DIGITAL SOUND LEVEL METER. Instruction Manual

Light Meter with Bar Graph

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

DO Meter Kit. Instruction Manual

Mini Environmental Quality Meter

Wide Range Pressure Meter Instruction Manual

Type K/J Thermometers

PH SD Card Datalogger. Instruction Manual

Mini Environmental Quality Meter

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD.

Sound Level Pen Instruction Manual

POCKET DIGITAL REFRACTOMETERS ~

Datalogging Manometer

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Bluetooth IR Pen. Instruction Manual

Psychrometer/Anemometer. Instruction Manual

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Vacuum Meter Instruction Manual

Dissolved Oxygen Meter

Datalogging RH / Temperature Pen Instruction Manual

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

Economical Rugged Series M1300K

Anemometer/Thermometer

Datalogging IAQ Meter Instruction Manual

WBGT SD Card Datalogger. Instruction Manual

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Torque Meter. Instruction Manual

WBGT SD Card Datalogger. Instruction Manual

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Datalogging Hot Wire CFM Anemometer

4 Channel Datalogging Thermometer. Instruction Manual

I/R Thermometer Gun 8:1

Datalogging Manometers 2PSI, 5PSI, 15PSI , ,

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630

PM2.5 and PM10 Monitors , & Instruction Manual

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operations Manual EcoSense ph100

Thermal Imaging Camera 220 x Instruction Manual

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC

MULTI- PARAMETER TESTER

TestLink Software for Software Instruction Manual

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

WalkLAB ph mv/orptemperature

Portable Conductivity Meter M1410. User Manual 1.002

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Temperature Datalogger

Cole-Parmer Instrument Company

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller


HI HI N HI HI

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

HI HI HI HI HI HI 98185

Operations Manual EcoSense ph100a

OPERATION MANUAL MODEL TT-LP

INSTRUCTION MANUAL. Portable ph and ph/ise Meters. Models 210Aplus 230Aplus 250Aplus 290Aplus

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Cole-Parmer Instrument Company

Instruction Manual ph 600/610/620 Waterproof Handheld ph Meter ph/mv/ion/ºc/ºf meter Technology Made Easy...

Operating Instructions

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Advanced Datalogging Sound Meter Instruction Manual

HI HI N HI HI

The Economy Conductivity Benchtop Meter

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

4801P ph/orp controller

Raphael Monitoring Kit. Instruction Manual

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

STARTER 3000 Bench ph Meter Instruction Manual

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

ph, mv and Temperature Instrument

Handheld Water Quality Meters 100 Series

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

GeneMate Benchtop ph Meters Operation Manual

Integrated Instruction Manual WP 600 Series Meters

Transcription:

AquaShock ph Meter 850057K 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com

AquaShock ph Meter 850057K Copyright 2011 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com

TABLE OF CONTENTS INTRODUCTION....................................................... 4 FEATURES........................................................... 5 POWER SUPPLY...................................................... 6 LCD DISPLAY......................................................... 6 MATERIALS SUPPLIED................................................. 7 KEYPAD............................................................. 8 SETUP MODE........................................................ 9 CALIBRATION........................................................ 11 MEASUREMENT PROCEDURES......................................... 12 OPTIONAL ACCESSORIES............................................. 15 SPECIFICATIONS..................................................... 16 WARRANTY......................................................... 17

INTRODUCTION The Sper Scientific AquaShock ph Meter (Model 850057) is the most waterproof, rugged and reliable ph meter on the market. It is fully waterproof, including probe connections, when used with the AquaShock probe. As with all AquaShock meters, Water Purity Meter model 850057 is fully shockproof, floats, and features a double injection molded case with an integral protective soft grip outer layer, high end antishock, LED backlight display, and is powered by the latest environmentally friendly, long lasting, rechargeable Lithium Ion battery. The meter is highly accurate and stable, very intuitive and includes all of the functions required by most users. Sper Scientific guarantees you will not find any meters more rugged and reliable than AquaShock. 4

FEATURES Floats Shockproof IP67 Waterproof Protective soft grip outer layer Rechargeable Lithium Ion battery Also accepts standard BNC probes Multi-line display LCD screen Reads ph and mv Automatic or manual temperature compensation Automatic buffer recognition Celsius or Fahrenheit selectable 99 data points for analysis Calibration point review Internal clock and calendar Maximum, minimum and average Hold function Low battery indicator Backlight 5

MATERIALS SUPPLIED Meter Dual ph/atc Probe 1 Lithium 1450 mah 7.4 V Battery DC Power Adapter Instruction Manual Hard Carrying Case LCD DISPLAY 1 3 4 2 5 6 7 8 Name Description 1 Ready Displayed when measuring results are stable 2 Electrode Durability Icon Current electrode durability 3 Scale Unit Current measurement scale unit 4 Measuring Results Current measurement value 5 ATC/MTC Automatic/Manual Temperature Compensation indicator 6 Temperature Scale Current temperature measurement unit 7 Temperature Value Current temperature measurement value 8 Battery Icon Current battery power level 6

LCD DISPLAY Probe Life Icon: More than 90% life remaining More than 85 90% life remaining More than 80-85% life remaining Less than 80% life remaining Battery Power Icon: Battery voltage is more than 7.7V shows full. Battery voltage between 7.2V and 7.7V shows 2 cells. Battery voltage between 6.6V and 7.2V shows 1 cell. Battery voltage less than 6.6V shows 0 cells and flashes. Display showing battery charging from less than 6.6V to fully charged. POWER SUPPLY This meter is powered by one Li-Ion (Lithium 7.4 V, 1450 mah) battery. The DC power adapter will charge the battery. This meter includes a charge protection function and will automatically stop charging when the battery is full with the meter turned off or on. A complete re-charge takes approximately 8 hours. 7

KEYPAD 1 2 3 4 5 6 7 8 Name 1st Function 2nd Function 1 Power/Backlight/Low Battery Power on/off Backlight on/off 2 Setup Setting parameters Confirm setting 3 MI Store data 4 MR Recall data 5 Max/Min/Ave Max/Min/Ave 6 Range/Temp Switch measuring scale Set temperature value 7 Hold/Exit Hold Exit 8 CAL Calibration 8

SETUP MODE The Setup Mode allows you to customize the following meter preferences and defaults: Temperature Units Clock Setting Restore Factory Defaults View Calibration Data View Probe Parameters 1. Press POWER for 1 second to turn the meter on before performing any setup function. Temperature Units 1. Press SETUP to enter the Setup Mode. 2. Press SETUP to enter the Set Temperature screen. 3. The unit C or F will flash on the LCD. 4. Press or to select the Celsius or Fahrenheit temperature unit. 5. Press SETUP to save and return to Normal Mode. 6. Press EXIT to return to Normal Mode without saving the selection. Real Time Clock 1. Press SETUP to enter the Setup Mode. 2. Press or to select the Set Clock screen. 3. Press SETUP to set the year. The value will flash on the LCD. 4. Press to increase the value by 1. Hold down to continually increase the value. Press to decrease the value by 1. Hold down to continually decrease the value. Press SETUP to save and the meter automatically moves to the month setting. 5. Repeat step 4 to adjust the month, day, hour, and minute. 6. Press EXIT to return to Normal Mode without saving. Note... This procedure adjusts the meter s internal clock. The internal clock will function when the meter is turned off but only when the battery is installed. 9

SETUP MODE Restore Factory Settings 1. Press SETUP to enter the Setup Mode. 2. Press or to select the Restore Factory Settings screen. 3. Press SETUP to confirm selection. NO will flash on the LCD. 4. Press or to select YES or NO. 5. When YES is displayed, press SETUP to confirm and all parameters will restore to factory settings (except the clock) and the meter returns to Normal Mode. 6. Press EXIT to return to Normal Mode without saving. View Calibration Data 1. Press SETUP to enter the Setup Mode. 2. Press or to select the View CAL Data screen. 3. Press SETUP to enter the mode. 4. Press to view the previous calibration point. Press to view the next calibration point. The date and time is on cyclical display. 5. Press EXIT to return to Normal Mode. View Probe Parameters 1. Press SETUP to enter the Setup Mode. 2. Press or to select the View Probe Parameters screen. 10

SETUP MODE Note... If the meter is not calibrated, the screen will show: Press SETUP or EXIT to return to Normal Mode. CALIBRATION Calibration should be performed whenever the probe has been out of use for 48 hours or longer. To prepare for calibration: 1. Immerse the ph probe in standard buffer solution for 30 minutes or longer. Calibrate With Temperature Sensor/ATC ph Probe 1. Press CAL for 2 seconds to enter Calibration Mode. 2. The meter will automatically recognize the NIST standard calibration buffer. The value and Finished will display on the LCD when the procedure is complete. 3. Press EXIT to return to Normal Mode. 4. Repeat Steps 1-2 to calibrate other points. Note... All other keys will be inoperable while using the calibration function. 11

CALIBRATION Calibrate Without Temperature Sensor/MTC ph Probe 1. Press CAL for 2 seconds to enter Temperature Setup Mode. The temperature value will flash on the LCD. 2. Press to increase the value. Hold down to continually increase the value. Press to decrease the value. Hold down to continually decrease the value. For C, the range is 0 ~ 60.0 C; for F, the range is 32 ~ 140.0 F. Press SETUP and the meter will automatically recognize the NIST standard calibration buffer. The value and Finished will display on the LCD when the procedure is complete. Repeat Step 2 to calibrate other points. 3. Press EXIT to return to Normal Mode. MEASUREMENT PROCEDURES Turning the Unit On/Off 1. Press POWER to turn the meter on. 2. Press and hold POWER for 2 seconds to turn the meter off. Backlight 1. With the meter on press POWER to turn the backlight on/off. Scale Selection 1. Press RANGE to switch between the ph and mv scales. 12

MEASUREMENT PROCEDURES Setting the MTC Temperature Do NOT connect the temperature sensor or non-atc probe while setting the temperature. 1. From Normal Mode, press RANGE for 2 seconds to enter Set Temperature Mode. The temperature value will flash on the LCD. 2. Press to increase the value. Press and hold to increase the value continuously. Press to decrease the value. Press and hold to decrease the value continuously. For C, the range is 0 ~ 60.0 C; for F, the range is 32 ~ 140.0 F. 3. Press SETUP to save and the meter returns to Normal Mode. 4. Press EXIT to return to Normal Mode without saving. Saving to Memory 1. Press MI to save the current value and view the data point number. There are 99 data points available. Recall Memory 1. Press RANGE to select the scale (ph or mv) for recall. 2. Press MR to enter Recall Mode and view the last measured value. The date and time are on cyclical display. 3. Press or to scroll saved data points. 4. Press EXIT to exit Recall Mode and return to Normal Mode. Clear Memory 1. Press MI and MR simultaneously for 2 seconds to clear all memory. The meter will return to Normal Mode. 13

MEASUREMENT PROCEDURES Maximum, Minimum, and Average 1. Press RANGE to select the scale. 2. Press MAX/MIN/AVE, the maximum recorded value will appear on the LCD. The date and time is on cyclical display. 3. Press MAX/MIN/AVE, the minimum recorded value will appear on the LCD. The date and time is on cyclical display. 4. Press MAX/MIN/AVE, the average recorded value will appear on the LCD. The date and time is on cyclical display. 5. Press MAX/MIN/AVE to return to Normal Mode. Hold 1. Press HOLD to hold the value. 2. Press HOLD to release the hold value. Note... When in Hold Mode, all other functions will be disabled except turning the meter off, backlight function, saving, and exiting Hold Mode. 14

OPTIONAL ACCESSORIES 840016 Standard ph Probe (non-atc) 840049 Spear Tip ph Probe (non-atc) 840092 Bench-Top Tripod 840093 Field Tripod 850057P AquaShock ATC ph Probe 860008A AquaShock ph 4.01 Buffer Solution - 3 bottles of 25ml each 860009A AquaShock ph 6.86 Buffer Solution - 3 bottles of 25ml each 860010A AquaShock ph 9.18 Buffer Solution - 3 bottles of 25ml each 860011A AquaShock Deionized Water - 3 bottles of 25ml each 860012A AquaShock ph Buffer Set - 1 Each ph 4.01, 6.86, 9.18 15

SPECIFICATIONS Power Button Indicator Light Power Off Power On Low Battery Charging Battery Light off Green light for 5 seconds, then light off Red light flashes every 5 seconds Blue light on Mode ph Temperature mv Range 0 ~ 14 ph 32 ~ 140 F -1999 ~ 1999 mv (0 ~ 60 C) Resolution 0.01 ph 0.1 F (0.1 C) 0.1 mv Accuracy ±0.02 ph ±0.9 F (±1.0 C) ±0.3 mv Input BNC Connector Temperature Probe BNC Connector Connector Calibration Up to 5 points Memory Up to 99 data points ph Slope Range 75% ~ 110% Temperature Compensation Automatic (ATC) or manual (MTC) from 32 ~ 140 F or 0 ~ 60 C Operating Temperature 32 ~ 122 F (0 ~ 50 C) Battery Lithium battery 7.4 V (1450 ma/h) Battery Life > 200 hours 16

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 7720 E Redfield Rd, Suite 7 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperscientific.com, or return your warranty card within 10 days of purchase. Revised 05/23/2012 17