AS-i Safety Analog Input Module, IP20

Similar documents
AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Analog Modules AS-i, IP67, M12

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

Digital Modules AS-i in IP20, 22,5 mm

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Output Module, IP20

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i Safety Input Modules (M12), IP67

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

Active Distributors AS-i Safety, Active Distributors AS-i

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Analog Modules AS-i IP65, M12

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Motor modules

Active Distributors ASi Safety, IP67

AS-i 3.0 motor modules

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

PCB AS-i modules, board based solutions

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Digital Modules AS-i, IP67, M12

AS-i 3.0 motor module

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

System manual AS-i safety monitor AC041S /00 05/2013

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave

Signal Doublers. VariTrans A 20300

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Safety module - PSR-SCP- 24DC/TS/S

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

E-STOP relays, safety gate monitors

ISOMETER isoev425 with coupling device AGH420

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Phone: Fax: Web: -

PHOENIX CONTACT Features

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

E-STOP relay, safety gate monitor

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

Installation Instructions Temperature transmitter TAA /00 06/2011

Safe timer relay/contact expansion modules

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Safe monitoring relays

LED Driver Linear / area fixed output

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MINI MCR-SL-PT100-UI-200

JUMO mtron T Measuring, Control, and Automation System

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

IB IL 24/48 DOR 2/W-XC-PAC

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

PSR DC/ESP4/2X1/1X2

E-STOP relays, safety gate monitors

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

LED Driver Linear / area fixed output

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ASI QUINT /2.4 EFD

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PGR-3200 MANUAL INSULATION MONITOR

PSR UC/ESAM4/3X1/1X2/B

ISOMETER isoev425/isoev425hc with coupling device AGH420

E-STOP relays, safety gate monitors

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Zelio Control-modular measurement and control relays 1

MCR-T-UI-NC. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

Extract from the online catalog

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

CSI 6300 SIS Overview

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Super universal modules

Expansion Module HZS 541-1S

Transcription:

2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs is monitoring 2 analog signals with 4... 20 ma, 0... 10 V, Pt100 or thermocouples. The module provides a safety SaW code sequence, if the input signal is located within the adjustable safety range. The two inputs can be analyzed as one safe 2-channel input (up to SIL3). Article no. BWU2692 BWU3271 General Data Device type input Connection AS-i / AUX connection Push-in terminals Push-in terminals Periphery connection Push-in terminals soldered screw terminals AS-i Profile safe input slave: S-0.B.E, ID1=F configuration slave: S-7.A.5, ID1=7 (default) Address depending on configuration Required Master profile M4 Since AS-i specification 3.0 Operating voltage 30 V DC (18... 31,6 V) Max. current consumption 110 ma AUX Operating voltage 24 V DC (18...30 V) Max. current consumption 1 A (0,5 A at 55 C) (1) Input Number 2 x analog standard inputs or 1 x 2 channel safe input, isolated Safety signal inputs 4... 20 ma / 0... 10 V / Pt100 thermocouple Resolution 16 Bit (1 µa / 1 mv) 16 Bit (0,1 C) Range of value 4000... 20000 dec. (4... 20 ma) / -2700... 17500 dec (-270... 1750 C) 0... 10000 dec.(0... 0 V) / -2000... 8500 dec (-200... 850 C) Measurement deviation < 1 % (2) (2) (5) < 0,2 % Internal resistance 50 Ω / 100 kω >1 MΩ Max. input voltage 25 V Max. input current 40 ma Power supply of attached sensors out of AUX www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 28.6.18 page 1

Article no. BWU2692 BWU3271 Display LEDs I1, I2 state of current inputs I1, I2 LEDs U1, U2 state of voltage inputs U1, U2 LEDs, R1, R2 state of Pt100 inputs R1, R2 LEDs TC1, TC2 state of thermocouple inputs TC1, TC2 LEDs F1, F2 on: safety range, SAW sequence is running off: no safety range, 0 sequence (shut off) is running LED ASI (green) on: AS-i voltage on flashing: AS-i voltage on, but peripheral fault (3) or address 0 off: no AS-i voltage LED FAULT (red) on: no data exchange, slave address 0 or slave offline flashing: peripheral fault (3) off: slave online LED AUX (green) on: 24 V DC AUX LED CONF off: normal operation mode Environment Applied standards EN 60529 EN 61000-6-2 EN 61000-6-4 EN 62061 SIL3 (4) EN ISO 13849-1 PLe (4) Operating altitude max. 2000 Ambient operating temperature 0 C +55 C Storage temperature -25 C +85 C Housing plastic, for DIN-rail mounting Protection category IP20 Voltage of insulation 500 V Dimensions (W / H / D in mm) 22,5 / 99,6 / 114 (1) Derating max. current out of AUX D I max. [A] e r 1,0 a t i n g0,5 T amb [ C] 0 25 55 (2) Related to the measuring range end value (3) See table "Peripheral fault indication" (4) In accordance with EN 746-2, Par. 5.7.2.b, components which meet a defined SIL / PL Level according to EN 62061 and EN ISO 13849-1 are approved for use in thermoprocessing equipment. (5) In order to achieve the best possible measuring accuracy, we recommend performing the installation with a distance equivalent to the width of one module on both sides of adjacent modules (see installation instructions). page 2 Mannheim, 28.6.18 We reserve the right to change any data www.bihl-wiedemann.de

Push-in terminals General Nominal cross section 2,5 mm 2 Conductor cross section Conductor cross section solid 0,2... 2,5 mm 2 Conductor cross section 0,2... 2,5 mm 2 flexible Conductor cross section flexible, with ferrule 2 conductors with same cross section, stranded, with TWIN ferrules AWG 24... 14 Stripped insulation length 10 mm without plastic sleeve: 0,2... 2,5 mm 2 with plastic sleeve: 0,25... 2,5 mm 2 without plastic sleeve: 0,5... 1,5 mm 2 Peripheral fault indication Article No. analog signal outside range of values difference between channels is outside of preset margin AUX voltage missing BWU2692 BWU3271 BWU2692 BWU3271 Clamps Description 0V 1ext.out, 24 V 1ext.out, connection for power supply of sensors 0V 2ext.out, 24 V 2ext.out U1 Sig-, U1 Sig+ connection 0...10 V safety input 1 I1 Sig-, I1 Sig+ connection 4...20 ma safety input 1 R1-, R1 Sig-, R1 Sig+, R1+ connection PT100 safety temperature 1 R2+, R2 Sig+, R2 Sig-, R2- connection PT100 safety temperature 2 TC1 Sig-, TC1 Sig+ connection thermocouple safe temperature 1 TC2 Sig+, TC2 Sig- connection thermocouple safe temperature 2 I2 Sig+, I2 Sig- connection 4...20 ma safety input 2 U2 Sig+, U2 Sig- connection 0...10 V safety input 2 ASI+, ASI- connection to AS-i bus AUX+ ext. in, AUX- ext. in connection for external 24 V DC (AUX) n.c. not connected www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 28.6.18 page 3

Setting the values maximum thrshold sensor signal minimum no safety range (0 sequence), shut off safety range (SaW sequence) Programming AI1: analog value sensor 1 DI0: input 1: safety range, SaW sequence is running Configuration Slave analog inputs AI2: analog value sensor 2 digital input DI1: input 2: safety range, SaW sequence is running digital output S.7.5 data DI2: DO2: 0 sequence is running (shut off) DI3: DO3: Safe Input Slave acknowledgment short circuit detection DO1: digital input Saw sequence digital output DO2: D3: LED status display LED State Signal / Description no AS-i voltage ASI (green) AS-i voltage present, but at least one AS-i slave is addressed 0 or peripheral fault AS-i voltage present AUX (green) no 24 V DC AUX 24 V DC AUX present page 4 Mannheim, 28.6.18 We reserve the right to change any data www.bihl-wiedemann.de

LED State Signal / Description AS-i communication OK (at least one AS-i slave on line) FLT (red) at least one AS-i slave with peripheral fault no data exchange (with at least one correctly addressed AS-i slave) CONF 2 x 1 Hz normal operation mode chip card is written no voltage input U1, U2 voltage input selected no current input I1, I2 current input selected no Pt100 input R1, R2 Pt100 input selected no thermocouple input TC1, TC2 thermocouple input selected no safety range (0 sequence), shut off is running F1, F2 safety range (SaW sequence), at least one code sequence is running LED on LED flashing LED off In case all LEDs are blinking simultaneously in fast rhythm a fatal error has been detected. This message is reset by a short disconnection of the power supply (Power ON Reset). www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 28.6.18 page 5