Ground Master Monitor Installation, Operation and Maintenance

Similar documents
WS Aware Monitor Installation, Operation and Maintenance

EM Aware Monitor Installation, Operation and Maintenance

EM Aware Monitor Installation, Operation and Maintenance

3M Ground Master Equipment Ground Monitor Models CTC065-RT and CTC065-5 User s Guide

WS Aware Workstation Monitor Installation, Operation and Maintenance

Zero Volt Monitor Installation, Operation and Maintenance

3M Wrist Strap and Ground Monitor 773. User s Guide

3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3

PGT 120. Personnel Grounding Tester. Wrist Strap and Footwear Tester. Users's Manual

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

3M Workstation Monitor Checker CTE701A User s Guide

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

Perle MCR200 Installation Guide

HV-CS kv Edge Mount Triaxial Jack

3M Static Monitor 790. User s Guide

2 Mesa Ethernet Dock User s Manual

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

WA4204-G2/G3 and WA4304-G2/G3

Model 2657A-LIM-3 LO Interconnect Module

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

4100/ VDC Converter Installation Instructions

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

2 in 1 LAN Tester and Multimeter Model:

MC 11 EB-2 Power supply cabinet with external bus, AC version

3M I/O Connector Mounting Options and Hardware

A-300 Speed Dome. Quick Start Guide

Line Impedance Stabilization Network (LISN)

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TruVision IP Thermal Camera Installation Guide

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Mini Digital Multimeter

User Guide True RMS Multimeter Extech EX205T

888385_01 Install.book Page 1 Wednesday, November 11, :45 PM. SMDR6 Installation Guide

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Network Camera. Quick Guide DC-B1203X. Powered by

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

Innovative Circuit Technology Ltd.

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

User's Guide. Digital Multimeter. Model MN42

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Model 2380 Rack-Mount Kit

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Model A Mini AC/DC Clamp Meter. User's Guide

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Preparing to Install the VG248

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

Model APT100 ROTATING VANE THERMO-ANEMOMETER PROBE

9040/9040UK. Users Manual. Phase Rotation Indicator

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Mini Digital Multimeter

COGNEX. Checker SensorView. Quick Reference Guide

Innovative Circuit Technology Ltd.

Broadband Automatic Disconnect Switch. User Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

Camera A14 and A34 Dome Camera

RS-422/485 to Fiber Industrial Converter

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

PowerMust Office Uninterruptible Power System

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

LTK1100 Series Card Reader User Manual

ENCELIUM EXTEND Manager Wiring and installation manual Light is OSRAM

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

D-Link Switch User Manual. Table of Contents

Mini Digital Multimeter

* * Agilent Power Distribution Unit (PDU) Installation Guide

8-port 10/100Base-TX Switch (INS-806) User s Guide

PR3400 Series 1.4Mp USB Cameras Hardware Guide

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Model 7705 Control Module

CMSA-100 Manual. Cinema Media Server Automation

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Allworx 24x Service and Troubleshooting Guide

HDMI and USB KVM Extender

Model GHz 50 Ohm RF Module

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

Compliance Information

2260B-RMK-Series Rack Mount Kit

4170 POS System Installation Guide

RMB Peripheral Units Installation Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

87421/22A Power Supply. Operating and Service Manual

SAFETY WARNINGS AND GUIDELINES

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Safety and Radio-Frequency Interference

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Transcription:

USER GUIDE TB-9078 Ground Master Monitor Installation, Operation and Maintenance Made in the United States of America The Ground Master Monitor and its accessories are available as the following item numbers: Item Description 770060 Ground Master Monitor 770064 Power Adapter, 100-240VAC Input, 7.5VDC 1.5A Output, All Plugs CTC065-C Ground Master Extension Cable Unit CTE701 Workstation Monitor Checker 770055 SMP Software Static Management Program Figure 1. SCS 770060 Ground Master Monitor Description The SCS Ground Master Monitor is an equipment ground continuous monitor for metal tools. It continuously monitors the path-to-ground and electromagnetic integrities of eight metal ground connections of process tools in work areas. This includes semiconductor, disk drive, flat panel, and electronic equipment manufacturing environments. The monitor provides both visual and audible alarms and includes fuse protection for each channel. The Ground Master Monitor continuously monitors eight metal tools for electromagnetic interference (EMI). EMI can cause equipment lockups and malfunction. The Ground Master Monitor will alarm if EMI is detected. Each Ground Master Monitor is calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology (NIST) and includes a certificate of calibration. ANSI/ESD S20.20 section 7.3 states Compliance verification records shall be established and maintained to provide evidence of conformity to the technical requirements. Per ANSI/ESD S1.1 Annex A.3 Daily (wrist strap system) testing may be omitted if constant monitoring used. Per ESD Handbook ESD TR 20.20 section 5.3.2.4.4 Typical Test programs recommend that wrist straps that are used daily should be tested daily. However, if the products that are being produced are of such value that knowledge of a continuous, reliable ground is needed, and then continuous monitoring should be considered or even required. The SCS 770060 Ground Master Monitor is compatible with SCS Static Management Program (SMP). SMP continuously monitors your ESD process control system throughout all stages of manufacturing. It captures data from SCS workstation, equipment and ESD event continuous monitors and provides a real-time picture of critical manufacturing processes. All activity is stored into a database for on-going quality control purposes. SMP allows you to pinpoint areas of concern and prevent ESD events. Quantifiable data allows you to see trends, become more proactive and prove the efficiency of your ESD process control system. SMP is sold separately. Click here to learn more. Packaging 1 Ground Master Monitor 1 Monitor Ground Cord (Green and Yellow) 4 Replacement Fuses (250 VAC, 125 ma) 1 Ring Terminal 1 Screw, Pan-Head, 6-32 x 1/4" 1 Star Washer 1 Power Adapter, 7.5VDC, with interchangeable plugs (North America, UK/Asia, Europe, China) 1 Certificate of Calibration TB-9078 Page 1 of 14 March 2017

Features and Components A A. Diagnostics Port: For manufacturer use only. B. Test Limit Rotary Switch: Sets the test limit of the tool monitor circuits from 1 to 20 ohms. B C D E F Setting Test Limit 1 1 ohm 2 2 ohms 3 3 ohms 4 4 ohms 5 5 ohms 6 6 ohms 7 7 ohms 8 8 ohms 9 9 ohms A 10 ohms* B 12 ohms C 14 ohms D 16 ohms E 18 ohms F 20 ohms *default setting G C. Power LED: Illuminates yellow when the monitor is powered. H I J K L M Figure 2. Ground Master Monitor features and components D. Tool LEDs: Illuminates green when its respective tool is properly grounded and free of electromagnetic interference (EMI). Blinks red when EMI is detected on its respective tool. Illuminates solid red and audible alarm sounds when its respective tool is not properly grounded. E. Tool Monitor Switches: Slide the switch up to enable its respective tool monitor circuit. Slide the switch down to disable its respective tool monitor circuit. F. Audible Alarm Switch: Enables and disables the monitor's audible alarm. G. Communication LEDs: Blinks when the monitor is powered and communicating to SMP Server. H. Protective Fuses: Protects the spread of harmful voltage to other tools via the Ground Master Monitor should one of the tools become exposed to excessive voltage. The appropriate fuse will disconnect the faulty tool from the Ground Master Monitor and from the other connected tools. I. Monitored Tool Terminals: Monitors metal tools for proper conductive resistance and electromagnetic interference (EMI). Use 18 AWG wire to connect the metal tools to these terminals. J. Ethernet Jack: Provides network communication between the Ground Master Monitor and Static Management Program (SMP). TB-9078 Page 2 of 14

K. Relay Terminal: Integrates with electronic tools, lights, buzzers, etc. L. Power Jack: Connect the included 7.5VDC power adapter here. M. Ground Terminal: Common ground point for the monitor. Installation Hardware Setup Grounded Metal Tool Tool Monitor Wire (not included) 5. Route the tool monitor wires from the bottom-side of the Ground Master Monitor to their respective grounded metal tools, and secure them. Keep the wires as short as possible. Do not loop or coil them as it may affect the measured impedance. 6. Connect an Ethernet cable to the Ethernet jack located on the bottom-side of the Ground Master Monitor. Verify that the cable is properly connected to a network. 7. Connect the power adapter to the power jack located on the bottom-side of the Ground Master Monitor. Route the wire from the supply to a nearby AC outlet and plug it into the outlet. Make sure the voltage and frequency match those listed on the power supply. The Ground Master Monitor is now powered. Relay Terminal The Ground Master Monitor features two normally closed optical relay terminals that can be integrated with electronic tools, lights, buzzers, etc. The relay opens when the monitor enters an alarm condition, and it remains closed otherwise. Pin 1 Monitor Ground Cord Ethernet Network Cable Power Adapter Figure 4. Relay terminal pin-out Figure 3. Wiring the Ground Master Monitor to two metal tools 1. Remove the Ground Master Monitor from the carton, and inspect for damage. 2. Determine the mounting location of the Ground Master Monitor, and use its mounting tabs to secure it. Its display should be visible to the operator(s). 3. Secure one end of the included ground cord to the ground terminal located on the bottom-side of the Ground Master Monitor. Attach the other end of the cord to a ground point. The face plate screw of a grounded AC wall outlet may provide a convenient connection point. 4. Insert stripped terminations of 18 AWG wires (not included) into the monitored tool terminals located on the bottom-side of the Ground Master Monitor. Ensure that the tool monitor switches are enabled if using these monitored tool terminals. Pin Value 1 Supply voltage (+5VDC) 2 Ground 3 Relay #1 4 Relay #2 5 Do not connect 6 Do not connect 7 Do not connect 8 Do not connect Parameter Peak Blocking Voltage Load Current On-Resistance (max) Rating 400 V P 140 ma rms / ma DC 22 ohms TB-9078 Page 3 of 14

SMP Network Setup The following procedure outlines how to connect the Ground Master Monitor to SMP via a local area network (LAN). SMP must be installed to a PC prior to using this procedure. DYNAMIC IP PROCEDURE 1. Verify that the Ethernet cable is securely connected to your network and Ground Master Monitor. The LEDs on the Ethernet port will illuminate when a connection to the network is established. 2. Open SCS SMP Server Monitor. 3. The SMP Server icon will appear in the Windows taskbar. 4. Click the SMP Server icon located on the Windows taskbar. The SMP Server menu will appear. Click the Start button to start SMP Server. TB-9078 Page 4 of 14

5. A message will appear and display Starting SMP Server Click the SMP Server icon located in the Windows taskbar. 6. SMP Server will now indicate Active server status. 7. SMP Server will search and find the Ground Master Monitor on the network. The Device and Active counts will increase to 1. TB-9078 Page 5 of 14

8. Open SCS SMP Admin. 9. The window for SMP Server Admin will appear. 1 unassigned is representative of the Ground Master Monitor that was just found by SMP Server. Click the Add New Building button. TB-9078 Page 6 of 14

10. Enter a building name, and then click the OK button. 11. The building name will appear on the navigation pane in SMP Server Admin. 12. Click on the building name in the navigation pane, and then click the Add New Floor button. TB-9078 Page 7 of 14

13. Enter a floor name, and then click the OK button. 14. The floor name will appear on the navigation pane in SMP Server Admin. 15. Click on the floor name in the navigation pane, and then click the Add New Line button. TB-9078 Page 8 of 14

16. Enter a line name, and then click the OK button. 17. The line name will appear on the navigation pane in SMP Server Admin. 18. Click on the line name in the navigation pane, and then click the Attachable Devices arrow located at the bottom of the window. TB-9078 Page 9 of 14

19. The serial number for the Ground Master Monitor will appear. Click attach. 20. The Ground Master Monitor will attach to the selected line. TB-9078 Page 10 of 14

21. Open SCS SMP Client. 22. Verify that the Ground Master Monitor was added to the appropriate building, floor and line. TB-9078 Page 11 of 14

Operation Use the table below to interpret the behavior of the Ground Master Monitor's tool LED's and audible buzzer (if enabled). Green LED Red LED Buzzer Status ON OFF OFF No failures OFF ON ON Impedance failure ON BLINK OFF EMI voltage failure OFF OFF OFF Monitor channel disabled Maintenance Cleaning Disconnect the power adapter from the device. Clean the Ground Master Monitor using a dry brush or vacuum cleaner. Clean its contacts using a contact cleaner or brush, and tighten all connections. Do not reconnect the power adapter until cleaning is finished. Replacing the Fuses If the equipment ground is disconnected for some reason, or the ground wiring is improperly connected, such equipment may receive significant damage, sometimes equal to the voltage on the AC mains (110VAC / 220VAC). In order to prevent the spread of this excessive voltage to other equipment via the Ground Master Monitor, fuses are implemented for each individual ground connection. In the case of excessive voltage on the equipment, the appropriate fuse will disconnect the equipment from the Ground Master Monitor and from the other connected equipment. Ground failure on that particular ground will be immediately indicated. Before replacing the fuse, always investigate the reason for the fuse blowing, and correct the problem. The fuse should never blow under normal circumstances. NOTE: Never use wire jumpers in place of fuses. Use only factory-authorized fuses. Disconnect power before replacing any fuses. Calibration Frequency of recalibration should be based on the critical nature of those ESD sensitive items handled and the risk of failure for the ESD protective equipment and materials. In general, SCS recommends that calibration be performed annually. Use the SCS CTE701 Workstation Monitor Checker to perform periodic verification (once every 6-12 months) of the Ground Master Monitor. The Workstation Monitor Checker can be used to check the test limits of the Ground Master Monitor without removing it from the factory floor. See TB-9031 for more information. Figure 10. SCS CTE701 Workstation Monitor Checker Specifications Power Power Adapter 100-240VAC 50-60 Hz Output: 7.5VDC @ 1.5A Output Plug Polarization: Center Positive Output Plug: 5.5 mm O.D. x 2.1 mm I.D. x 9.5 mm L Metal Tool Amount Monitored 8 Impedance Limit 10 ohms (default) EMI Voltage Limit 223 mv Connectivity Input 18 AWG wire terminal blocks for metal tools Outputs RJ45 connector Ethernet output General Alarm LEDs and buzzer Dimensions 3.54" x 5.52" x 1.18" (90 mm x 140 mm x 30 mm) Weight 0.4 lbs. (0.18 kg) TB-9078 Page 12 of 14

Safety Information Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future reference. Intended Use The SCS Ground Master Monitor is an equipment ground continuous monitor for metal tools. It continuously monitors the path-to-ground and electromagnetic integrities of eight metal ground connections of process tools in work areas. This includes semiconductor, disk drive, flat panel, and electronic equipment manufacturing environments. The monitor provides both visual and audible alarms and includes fuse protection for each channel. The systems must be installed as specified in this user guide in an indoor commercial/industrial environment, and have not been evaluated for other uses or locations. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Warning To reduce the risks associated with hazardous voltage and fire: Do not use the power supply if damaged Replace power supply if damaged using only SCS supplied parts. Do not modify or attempt to service the power supply. Return to SCS for service. Do not use the Ground Master Monitor or its power supply outdoors or in wet/humid environments. Do not use the Ground Master Monitor or its power supply outside of the operating conditions listed in this User Guide. Use only a dry cloth when cleaning. To reduce the risks associated with hazardous voltage: Use only the power supply provided by SCS and specified for the country of use. Do not simultaneously power the Ground Master Monitor with the power supply and the RJ45 data cable. Do not position the monitor accessories or other equipment where unplugging the power supply is difficult. Always locate the power source (socket or outlet) near the equipment. The power supply plug serves as the disconnect device. Notice To reduce the risk of damage to components or assemblies being handled: Monitor must be checked periodically to verify each test mode is functioning correctly. Ensure proper operation of the monitor by performing operational verification test as required. Always properly ground your tools and dissipative surfaces to before connecting them to the Ground Master Monitor. FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Industry Canada ICES-003 Compliance: CAN ICES-3 (A)/NMB-3(A) Environmental Conditions This equipment has been tested and found to be safe to operate within these environmental conditions. This is not a warranty of equipment performance within these conditions. Indoor use only Ingress Protection: IPX0 Altitude: Up to 2,000 m Mains supply voltage fluctuations up to ± 10% of the nominal voltage. Transient over-voltages up to the levels of overvoltage category II. Temporary over-voltages occurring on mains supply. Pollution degree 2. Temperature: Maximum 110 F / 43 C, Minimum 50 F / 10 C Humidity: Maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. Caution To reduce the risks associated with environmental contamination: Dispose of monitor and power supply in accordance with all applicable local and government regulations. TB-9078 Page 13 of 14

Regulatory Information China RoHS Electronic Industry Standard of the People s Republic of China, SJ T11363-2006, Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products This symbol, per Marking for the Control of Pollution Caused by Electronic Information Products, SJ/T11364-2006, means that the product or part does contain a substance, as detailed in the chart below, in excess of the following maximum concentration values in any homogeneous material: (a) 0.1% (by weight) for lead, mercury, hexavalent chromium, polybrominated biphenyls or polybrominated diphenyl ethers; or (b) 0.01% (by weight) for cadmium. Unless otherwise stated by SCS in writing, this information represents our best knowledge and belief based upon information provided by third party suppliers to SCS. Part or Component Name Hazardous Substances or Elements (Pb) (Hg) (Cd) (CrVI) (PBB) (PBDE) Solder in instrument X O O O O O O: Indicates that this hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in the SJ/T11363-2006. X: Indicates that this hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in the SJ/T11363-2006. Limited Warranty, Warranty Exclusions, Limit of Liability and RMA Request Instructions See the SCS Warranty - http://staticcontrol.descoindustries.com/limited-warranty.aspx TB-9078 Page 14 of 14