RGU Main Control Board Replacement Firmware Version 3.01

Similar documents
(Catalog Numbers 1394-FK10TS and -FK22TS)

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

Allen-Bradley 1397 AC Tachometer Interface Card

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

Embedded EtherNet/IP Option Card for DriveLogix 5730 Controllers

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

SynchLink Board for PowerFlex 700S Drives with Phase II Control

Allen-Bradley 1397 L11 I/O Expansion Card

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

PowerFlex DC Stand-Alone Regulator (SAR) In-Rush Limiting Resistor

PowerFlex DC Stand-Alone Regulator (SAR) Power Interface Circuit Board

Memory Expansion for DriveLogix Controller

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

PowerFlex DC Stand-Alone Regulator (SAR) Switching Power Supply Circuit Board

Troubleshooting Guide

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

PowerFlex 700 Power Jumpers

PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers

Kinetix 6000 Axis Module and Shunt Module

Application Guide. Considerations for 32 Bit Integer Parameters in 16 Bit Processors. PowerFlex 700VC, PowerFlex 700S. Introduction.

Replacing or Upgrading DiskOnChip Memory

Installation Instructions

Allen-Bradley. Regenerative DC Bus Supply Unit (RGU) User Manual. Bulletin 2364F Firmware 3.02

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

Ferrite Core for Internal DPI Cables on PowerFlex 700S Frame 3 and 4 Drives

PowerFlex 700S and 700H Frame 11 Replacement Power Structures

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

PowerFlex 750-Series Power Option Cabinets

Allen-Bradley Motors

AC300/AC400 SERIES DYNAMIC BRAKING and ADDITIONAL FORM C RELAY. INSTALLATION INSTRUCTIONS Document Number:

1395 Node Adapter Board Troubleshooting

Installing Your 1394 Drive Interface Module

Digital ac/dc (24V) Input Module

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Resolver to Digital Expansion Board

Replacing the Power Supply

PS/IO Circuit Board Retrofit

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Print Mechanism Maintenance Kit

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Allen-Bradley Parts. Solid State Drive Upgrade Kit. Installation Instructions. About this Product

Veritas Appliance Hardware Service Procedure

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

InView Firmware Update

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Solar Combiner Enclosure

Upgrading LVDS Cables Instruction Sheet

PowerFlex 700S and 700H Frame 13 Replacement Power Structures

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

Installation Instructions

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Regulator Board Installation Instructions for WebPak 3000 Version 1.x Drives

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

Replacement Keyswitch Assembly

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

Installation Instructions

Veritas Appliance Hardware Service Procedure

INSTRUCTION BULLETIN

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

PowerLogic High Density Metering System 1-Meter Enclosure

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Installation Instructions

Z Series and S4M Ribbon Take-Up Spindle Maintenance Kit

AutoScan to MultiScan Replacement Kit

EPROM Replacement for Contrbl Systems

8510 AC Spindle Drive Hardware/Firmware Replacement

ArmorPoint I/O Field Potential Distributor, Series A

E1135C PDU and Pod Upgrade Procedure

Dell OptiPlex All-in-One. Stand Installation Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

To connect the AC adapter:

Analog Monitor Installation Manual

Installing the EN-4000

Installation Instructions

460 to 230 Volt Conversion Kit for FlexPak 3000 or WebPak 3000 Drives

GPIB-232CT-A IBCL EPROM Installation Guide

Keysight Add Source and Receiver Attenuators Upgrade Kit

S Reclosers. Contents. Form 6 Recloser Control Disassembly, Reassembly, and Testing Instructions

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Digital ac/dc (24V) Input Module

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

GE Industrial Systems

WARNING ELECTRICAL SHOCK HAZARD

Monitor - 15-Inch LCD - Replacement

Intel NUC Kit NUC6CAYS User Guide

Bulletin 1336 Adjustable Frequency AC Drive 1336 B075 B C075 C VT B075 B150. Troubleshooting Guide

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

Transcription:

Replacement Kit Instructions RGU Main Control Board Replacement Firmware Version 3.0 Contents This document shows how to remove and replace the main control board in a Regenerative DC Bus Supply Unit (RGU). What This Kit Contains Using the table below, verify that you have received the appropriate items in your kit: For this part: You should receive this quantity: main control board ESD wrist strap Other Items Needed Before you begin, be sure you also have the following: Tools you will need for: Measuring voltages Removing, loosening, and tightening screws (including terminal screws) Torquing screws (4 to 4 lb-in / 0.5 to.5 N-m) Documentation: Your drive system schematics Publication 2364F-5.0, Regenerative DC Bus Supply Unit (RGU) User Manual Publication 2364F-5.2 March 999

2 RGU Main Control Board Replacement Firmware Version 3.0 Safety Precautions The following general precautions apply when servicing an RGU or a drive system lineup:! ATTENTION: Only those familiar with the drive system, the products used in the system, and the associated machinery should plan or implement the installation, startup, and future maintenance of the system. Failure to comply can result in personal injury and/or equipment damage. ATTENTION: Verify that all sources of AC and DC power are deenergized and locked out or tagged out in accordance with the requirements of ANSI/NFPA 70E, Part II. ATTENTION: The system may contain stored energy devices. To avoid the hazard of electrical shock, verify that all voltage on capacitors has been discharged before attempting to service, repair, or remove a drive system or its components. You should only attempt the procedures in this manual if you are qualified to do so and are familiar with solid-state control equipment and the safety procedures in publication NFPA 70E. ATTENTION: When servicing any unit, do not drop any nuts, bolts, washers, etc. inside the unit, as they may cause a short circuit on power up. ATTENTION: This drive system contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, or repairing this assembly. Component damage can result if ESD control procedures are not followed. If you are not familiar with static control procedures, refer to Allen-Bradley publication 8000-4.5.2, Guarding Against Electrostatic Damage or any other applicable ESD protection handbook. Special Instructions Important: You will need to reuse parts that are removed from the unit. Place parts, in the order removed, on a clean surface. Important: The new main control board may not include the same parameter settings as the existing board. If necessary, record the parameter settings before replacing the main control board. Publication 2364F-5.2 March 999

RGU Main Control Board Replacement Firmware Version 3.0 3 Preliminary Steps Before replacing the main control board, shut off the power; lockout/tagout the unit; and wait five minutes for all voltage to discharge. Open the bay door to the power structure. Verify that the board is labeled with the appropriate catalog number (see the example in Figure ). Figure Checking the Catalog Number of the Main Control Board Catalog Number 2364-SPM0C 2364-SPM03A Series Type Series A units Series B units SPARE PART # 2364-SPM03A Catalog Number CAT 2364FA-MNB Series Identifier SER B &267$7Ã72548( For example, if the data nameplate for an RGU has a Series B identifier (or 3 CT current monitoring), the new main control board should be labeled with the catalog number 2364-SPM03A. New Main Control Board 5HIHUÃWRÃXVHUÃPDQXDOÃIRU LQVWDOODWLRQÃLQVWUXFWLRQV $&Ã,387 '&Ã287387 92/76 $ +].9$ 3+ 54 460 678 3 50/60 524 683 749 - DC RGU Data Nameplate Located near Main Control Board on the unit Replacing the Main Control Board. Using a meter, test the voltage across the AC line, across the DC bus, and across the terminals and test points on the main control board.! ATTENTION: If there is any voltage present, remove the source of the voltage. Check for voltages again before proceeding to the next step. 2. Put on the ESD wrist strap and attach it to the PE busbar (back grounding bar in the bottom of the unit). 3. Disconnect J2, J3, J9, J0, J, J2 from the main control board (as shown in Figure 2). 4. Disconnect TB from the main control board. 5. Remove the screws which mount the main control board to the mounting plate. 6. Slide the main control board upward, then pull the board off. 7. Remove any communication boards (and standoffs) which are attached to the main control board (as shown in Figure 3). 8. Place the main control board in an anti-static bag. Publication 2364F-5.2 March 999

4 RGU Main Control Board Replacement Firmware Version 3.0 Figure 2 Main Control Board J3 To Gate Driver Board (J) J2 To NTC Bridge Thermal Sensor J7 J8 J J4 TB J 2 J9 J0 To SCANport Device To SCANport Device J3 To Laptop PC (Used Only for Upgrading Firmware) To TE Available for User Connections (Analog I/O) To Isolation Board (J2) Figure 3 Removing/Installing a Communication Board Connection Cover Connection Port Mounting Screws Standoffs Publication 2364F-5.2 March 999

RGU Main Control Board Replacement Firmware Version 3.0 5 Installing the Main Control Board. Put on the ESD wrist strap and attach it to the PE busbar. 2. Mount any communication boards that were previously removed from the main control board (as shown in Figure 3). Torque all mounting screws to 4 lb-in (0.5 N-m). 3. Slide the main control board downward onto the slide-mount standoffs. 4. Mount the main control board to the mounting plate. Torque the mounting screws to 4 lb-in (.5 N-m). 5. Connect TB to the main control board. Verify that all the terminals are secure. 6. Connect J2, J3, J9, J0, J, and J2 as shown in Figure 2. Concluding Steps After installing the main control board, remove all tools and debris from the unit and secure the bay door. Send the old board to Rockwell Automation for repair or dispose of the board according to your company s procedures and local ordinances.! ATTENTION: The parameters must be configured before operating the unit. See the startup chapter of publication 2364F-5.0 to configure the parameters in the new main control board. Publication 2364F-5.2 March 999

Publication 2364F-5.2 March 999 PN 92658 Supersedes Publication 2364F-5.2 - November 998 Copyright 999 of Rockwell International Corporation. Printed in the USA