Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Similar documents
Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERD.12

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-AHD.22

Electronic timer CT-ERS.21

Electronic timer CT-ARS.11

Three-phase monitoring relay

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Power supply CP-C 24/5.0

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Messaging module CP-C MM

Contact protection relay

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Power supply CP-E 48/1.25 Primary switch mode power supply

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.21

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relay CM-MSS.41

Power supply CP-E 24/0.75 Primary switch mode power supply

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Power supply CP-E 24/10.0 Primary switch mode power supply

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-D 12/2.1 Primary switch mode power supply

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Pluggable interface relays CR-M Miniature relays

Thermistor motor protection relay CM-MSS.11

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

RM35LM33MW liquid level control relay RM35-L V AC/DC

Power Supply HARTING pcon

Redundancy unit CP-A RU

Pluggable interface relays CR-P Pcb relays

Thermistor motor protection relay CM-MSS.31

Thermistor motor protection relay CM-MSS.41

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Power supply CP-C 24/5.0

Power Supply HARTING pcon

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Accessories for pluggable interface relays CR-M Sockets

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

Pluggable interface relays CR-M Miniature relays

TU531, TU532 Terminal Unit

DC541 Digital Input/Output Module

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

AO523 Analog Input Module

DC522 Digital Input/Output Module

Circuit diagram. Time ranges. Function. Function diagrams. Notes. Dimension diagram. Page 1

DC561, digital input/output module,

Electronic time relays ATI, BTI, SDT and MTI

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

CI542 PROFIBUS Communication Interface Module

RM35TF V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

MasterINTERFACE 39 Series - Relay interface modules

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

02/11/2015

TF501, TF521 Terminal Bases

AI531 Analog Input Module

Electronic timers CT range

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

MINI-PS AC/10-15DC/8

Transcription:

2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 U: green LED - Supply voltage (LED flashes during timing) 4 R: red LED - Output relay energized 5 Circuit diagram 6 Function diagram Characteristics Supply voltage: 24-240 AC and 24-48 DC Single-function ON-delay timer One device includes 7 time ranges, from 0.05 s to 100 h 1 c/o contact 2 LEDs for status indication Narrow width of only 17.5 mm Approvals a e f Marks g c culus GOST CCC CE C-Tick Order data Type Supply voltage Order code CT-ERD 24-240 AC, 24-48 DC 1SR 500 100 R0000 Application With their structural form and their width of 17.5 mm only, the CT-D range timers are ideally suited for installation in distribution cabinets. Operating mode The CT-ERD with 1 c/o contact offers 7 time ranges, from 0.05 s to 100 h. The time delay range is rotary switch selectable on the front of the unit. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit. Function diagram A ON-delay Delay on make) Timing begins when supply voltage is applied to terminals A1-A2. The green LED flashes during timing. When the selected time delay is complete, the output relay energizes and the flashing green LED turns steady. If supply voltage is interrupted, the output relay de-energizes and the time delay is reset. Interrupting supply voltage before the time delay is complete, resets the time delay. the output relay does not energize. A1-A2 15-18 15-16 green LED red LED t < t 2CDC 252 168 F0205 t = adjusted delay time 1

Connection diagram A CT-ERD A1 A1 A2 15 15 16 18 2CDC 252 177 F0005 18 16 A2 ersion: 1SR 500 100 R0000 A1-A2 Supply: 24-240 AC or 24-48 DC 15-16/18 c/o contact 2

Technical Data Input circuits Supply voltage A1-A2 24-240 AC / 24-48 DC Power consumption 24-240 AC / 24-48 DC approx. 0.6-1.3 A/W Supply voltage tolerance -15...+10 % Supply voltage frequency DC supply 0 Hz AC supply 50/60 Hz Duty time 100 % Timing circuit Time ranges 0.05 s - 100 h 1) 0.05-1 s 2) 0.5-10 s 3) 5-100 s 4) 0.5-10 min 5) 5-100 min 6) 0.5-10 h 7) 5-100 h Recovery time < 50 ms Repeat accuracy (constant parameters) < +/- 0.5 % Timing error within the supply voltage tolerance range < 0.5 % Timing error within operating temperature range < 0.06 % / C Indication of operational states Supply voltage / timer green LED steady / flashing while timing Output relay energized red LED Output circuits 15-16/18 Number of contacts relay, 1 c/o contact Contact material AgSnO 2 Related voltage acc. to DE 0110, IEC 60947-1 250 Minimum switching voltage 12 Maximum switching voltage 250 AC Minimum switching current 100 ma Maximum switching current 6 A Rated switching current acc. to IEC 60947-5-1 AC-12 (resistive) 230 6 A AC-15 (inductive) 230 3 A DC-12 (resistive) 24 6 A DC-15 (inductive) 24 2 A Maximum lifetime mechanical 30 x 10 6 switching cycles electrical (AC-12, 230, 4 A) 0.1 x 10 6 switching cycles Short circuit proof, max. fuse rating n/c 6 A fast, operating class gl n/o 10 A fast, operating class gl General data Enclosure width 17.5 mm length 70.0 mm depth 63.0 mm Wire size fine-strand with wire end ferrule 2 x 1.5 mm 2 fine-strand without wire end ferrule 2 x 2.5 mm 2 rigid Weight approx. 60 g (2.1 oz) Mounting position any Degree of protection enclosure / terminals IP50 / IP20 Temperature operating -20...+60 C storage -40...+85 C Mounting DIN rail (EN 50022), snap-on mounting Standards Product standard IEC 61812-1 10.1996, EN 61812-1 + A11/8.1999, DIN DE 0435 Teil 2021 EMC Directive 89/336/EEC Electromagnetic compatibility IEC 61000-6-2, EN 61000-6-4 ESD acc. to IEC 61000-4-2, EN 61000-4-2 level 3 6 k / 8 k HF radiation resistance acc. to IEC 61000-4-3, EN 61000-4-3 level 3 10 /m Burst acc. to IEC 61000-4-4, EN 61000-4-4 level 3 2 k / 5 khz Surge acc. to IEC 1000-4-5, EN 61000-4-5 level 4 2 k L-L 3

10 4 0 1 2 3 4 5 6 7 8 9 Electronic timer CT-ERD HF line emission acc. to IEC 1000-4-6, EN 61000-4-6 level 2 10 Low oltage Directive 73/23/EEC Operational reliability acc. to IEC 68-2-6 4 g Mechanical resistance acc. to IEC 68-2-6 6 g Approvals / Marks Approvals culus, GOST and CCC Marks CE and C-Tick Isolation data Rated insulation voltage between supply circuit, acc. to DE 0110, IEC 60947-1 300 control circuit and output circuit Rated impulse withstand voltage between all isolated circuits acc. to DE 0110, IEC 664 4 k / 1.2-50 µs Test voltage between all isolated circuits 2.5 k, 50 Hz, 1 min. Pollution category acc. to DE 0110, IEC 664, IEC 255-5 2 Overvoltage category acc. to DE 0110, IEC 664, IEC 255-5 III Environmental testing acc. to IEC 68-2-30 24 h cycle time, 55 C, 93 % rel., 96 h Load limit curves AC load (resistive) 300 200 100 80 60 50 40 30 20 2CDC 252 195 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A DC load (resistive) 300 200 100 80 60 50 40 30 20 2CDC 252 196 F0205 10 0.1 0.2 0.5 1 2 4 6 10 I A Derating factor F for inductive AC load 1.0 0.9 0.8 F 0.7 0.6 0.5 2CDC 252 192 F0205 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Contact lifetime /switching cycles N 10 7 N 10 6 10 5 2CDC 252 197 F0205 I A 220 50 Hz 1 AC 360 cycles/h 4

Dimensional drawings Dimensions in mm 6.89 17,5 1.97 5 58 22.84 43,4 17.05 70 27.56 45 17.72 2CDC 252 190 F0005 5

Druckschrift-Nummer. 2CDC 111 046 D0201 Printed in the Federal Republik of Germany (08/05) ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Deutschland Postfach 10 16 80 69006 Heidelberg, Deutschland Internet http://www.abb.com/lowvoltage -> Control Products -> Electronic Relays E-Mail epr-support@stotzkontakt.de