TG Technical specifications

Similar documents
DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

UA Series IIoT Communication Server

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

TM251MESC controller M251 Ethernet CAN

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM258LF42DT compact base M I/O - 24 V DC - CANopen

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

OnCell G3100 Series Quick Installation Guide

TM258LD42DT4L compact base M I/O - 24 V DC

Features and Benefits. Certifications

TM251MESC controller M251 Ethernet CAN

TM241CE24T controller M IO transistor PNP Ethernet

TM258LD42DT4L compact base M I/O - 24 V DC

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM241C40U controller M IO transistor NPN

TM241C24T controller M IO transistor PNP

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Turck Cloud Gateway UMTS Gateway TCG20-UMTS-1ETH-CRS-01

EZmoto V4.1 Product description Rev. 2 30/07/2015

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

TM241CE40R controller M IO relay Ethernet

Feature and Benefits. Certifications

LMC058LF42 compact base - 42 I/O - 24 V DC supply

LMC078CECS20T motion controller LMC078-20DIO transistor sercos compact Ethernet Canopen 24Vdc

PLC PFC200 Controller PFC200 CS 2ETH RS

TM241C40R controller M IO relay

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

TM221ME16T controller M IO transistor PNP Ethernet

UCM 94/1 3G/GPRS Modem for RTU32 Series

TM221M16TG controller M IO transistor PNP spring

TM221ME32TK controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

P USB 2.0 (Type B) Port - Programming - Online monitoring

ZETA Series 2G/3G/4G Modems with GPS Option

TM221CE24T controller M IO transistor PNP Ethernet

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

-C5RS-LC RS232 EXTENDER

TM221CE40R controller M IO relay Ethernet

Wireless Gateway ARG600 ANSI Product Guide

ZETA Series 2G/3G/4G Modems with GPS Option

TM221M16R controller M IO relay

TM221M32TK controller M IO transistor PNP

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

MGate 5105-MB-EIP Series

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM221CE24R controller M IO relay Ethernet

EC-PU4. Processor unit with 4 communication ports

OnRISC. OnRISC Baltos ir 2110

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

USER MANUAL FOR GS100/GS1003G

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

WBD-222. Hardware Manual. Revision September Copyright 2010 WILIGEAR

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

LMC058LF42 compact base - 42 I/O - 24 V DC supply

MobileAccessVE Control Unit: Dual-Band

Reliable and Remote-Manageable for Large Scale M2M Deployment

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Features and Benefits. Certifications

GenIP : Intelligent gateway dedicated to most critical industrial applications

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

Communication Interface

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

UK +44 (0) // USA // JAPAN //

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

OnCell G3150A-LTE Series

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Sauter Systems

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

UA-5200 IIoT Communication Server

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Ursalink UR55 Industrial Cellular Router Datasheet

Ursalink UR51 Industrial Cellular Router Datasheet

Reliable and Remote-Manageable for Large Scale M2M Deployment

RTU32S RTU32S Series Small Compact Utility RTU

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

IES615-2D Series. Industrial Ethernet Switch. User Manual. Summarize. Panel layout. Packing list. Features. Shenzhen 3onedata Technology Co., Ltd.

TWDLCDE40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

Features and Benefits. Certifications

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Ursalink UR71 Industrial Cellular Router Datasheet

Datasheet: com.tom INDUSTRY

Reliable and Remote-Manageable for Large Scale M2M Deployment

WAVE-4G-GPS. Technical Specifications Sheet. Waveloc IT Solutions LTD. Wave-4G-GPS Technical Specifications Sheet

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

AC 800M for Compact Product Suite Outline of all modules

Transcription:

TG2-500 Technical specifications

TBox TG2-500 Specifications SPECIFICATIONS Standard: 3 wires 4G Modem -4E: Europe -4N: North America Backup battery charger TG2-500: COMMUNICATION PORTS TG2-500-4E: COMMUNICATION PORTS Options: -4E: GSM 4G TG2-500-4N: COMMUNICATION PORTS Options: -4E: GSM 4G General Technical Specifications GENERAL Processor 32bits, ARM based, 400Mhz Real-time clock, backed up Clock Clock Drift Typical: 1.7sec. at 25 C Watchdog Watchdog circuitry included Maximum process cycle time = 1sec. Toggle Switch LED - Green 2Hz LED - Green 0.5Hz LED - Green ON LED - Red 8Hz STOP - RUN - RESET Normal operation Application stopped OS stopped Presence of Alarm(s) POWER SUPPLY Voltage 8-30V DC Voltage - with backup battery 20-30V DC Card Consumption Typical 100mA (depending on features used) Protection Reverse polarity Internal soldered fuse BATTERY CHARGER Power supply Vin required 20-30V DC Mode Constant current / limited voltage Voltage Maximum: 13.8V at 25 C Current Maximum: 250mA APPROVALS CE, FCC, CSA for US and Canada, C-Tick, A-Tick, RoHS INTERNAL BATTERY Voltage Use Lifetime MEMORY Flash SDRAM SRAM MicroSD (optional) 3V, lithium battery (CR2450) Backup of clock and RAM (datalogging) Battery consuming only when TBox Lite is out of power and plastic strip has been removed. Typical 4 years at 25 C WARNING: After such a period out of power, the battery must be replaced to maintain the clock and datalogging. 32MB (Uboot, LINUX, OS, Application, Web & Reports, Sources) 64MB (Running part of LINUX, OS, Application) 1MB, backed up with lithium battery (datalogging, log, backup value of tags) Max. 32GB It is highly recommended to use an industrial grade SD card (ref. ACC-µDIN-1Gb)

COMMUNICATION PORTS Built-in communication ports 1 x 1 x 1 x 1 x Optional communication ports 4G Modem (-4E, -4N) (BUILT-IN) Spring-cage terminal block Cabling (see schema next) 2 wires: TxD, RxD Protocols Modbus-RTU Slave, Master, ASCII (supplementary protocol with addons) (BUILT-IN) Spring-cage terminal block Cabling (see schema next) 2 wires: A+, B- Number of slaves 256 (if technology of slaves allows it too) Protocol Modbus-RTU Master and Slave (supplementary protocol with add-ons) Isolation No isolation between signals A-B and power supply Termination Terminations of 120Ω (between A-B at both ends) are in most cases not necessary, but they increase the quality of the signals for long distance connections. Failsafe bias resistors included: pullup and pulldown resistors which assures a logical level TRUE when A and B are opened or in short-circuit. (BUILT-IN) Model 2.0 Use of As Device : programming, displaying WebForm 2.0, stick As Host : to WiFi or Serial devices type A female (socket) Cabling A / A male cable (host to host) Speed High Speed (480Mbits / sec.) Current Max 500mA at ambient temperature ETHERNET (BUILT-IN) Model 100 BASE-TX (4 wires) Full Duplex / Auto-negotiation Cabling Speed Protocols TCP / IP Connections LEDs RJ45 Straight pinned CAT5 shielded cable or crossover CAT5 shielded cable 10 / 100Mbits Modbus / TCP Master and Slave, SMTP(S), FTP(S), HTTP(S), SNMP, IEC 60870-5-104, DNP3, Ping Client for Remote Tags: 1 socket 1 context Client for Alarm: 2 sockets (required for FTP) 1 context Server Modbus: 64 sockets 64 contexts Server HTTP: 64 sockets 64 contexts 100: ON when connected at 100Mhz OFF when connected at 10Mhz Lk: ON when linked FLASH when communicating 4G MODEM (OPTIONAL) Frequencies Model Europe Penta Band LTE (4G): 800 / 900 / 1800 / 2100 / 2600Mhz. FDD-Bands (20,8,3,7,1) Tri Band UMTS-WCDMA (3G): 900 / 1800 / 2100Mhz. FDD-Bands (8,3,1) Dual Band GSM / GPRS / EDGE (2G): 900 / 1800Mhz. Frequencies Model North America Penta Band LTE (4G): 700 / 850 / AWS (1700 / 2100) / 1900Mhz. FDD-Bands (13,17,5,4,2) Tri Band UMTS- WCDMA (3G): 850 / AWS (1700 / 2100) 1900Mhz. FDD-Bands (5,4,2) Quad Band GSM / GPRS / EDGE (2G): 850 / 900 / 1800 / 1900Mhz. Output Power Model Europe According to Release 99 (3G): Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 / -4dB) for GSM 1800 8-PSK

Output Power SIM card Class 3 (+24dBm +1 / -3dB) for UMTS 2100,1800,900. WCDMA FDD-Bands (1,3,8) According to Release 8 (4G): Class 3 (+23dBm +-2dB) for LTE 2600,2100,1800,900,800. LTE FDD-Bands (7,1,3,8,20) Model North America According to Release 99 (3G): Class 4 (+33dBm ±2dB) for EGSM850, EGSM900 Class 1 (+30dBm ±2dB) for GSM1800,1900 Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK,GSM 900 8-PSK Class E2 (+26dBm +3 / -4dB) for GSM 1800 8-PSK, GSM 1900 8-PSK Class 3 (+24dBm +1 / -3dB) for UMTS 1900,AWS,850. WCDMA FDD-Bands (2,4,5) According to Release 8 (4G): Class 3 (+23dBm +-2dB) for LTE 1900,AWS,850,700,700. LTE FDD-Bands (2,4,5,13,17) Standard size, 1.8V or 3V SIM card accepted Antenna connector LED - On LED - T / R GSM Module Approvals ENVIRONMENT Storage Working Humidity Altitude Screw connector, type SMA Female (Jack) on TBox LT2 Flashing: connected to the Network ON: Indicates the modem in On line (= connected in DATA or IP) Transmit or Received = ON R&TTE, GCF, CE, FCC, PTCRB, UL California RoHS AT&T and Verizon operator approvals -40 C to +85 C -40 C to +70 C 0 to 95% without condensation Max. 4000m DIMENSIONS With rack, without connector Height x Depth x Width: 152mm x 115mm x 40mm (5.984 x 4.428 x 1.575 ) Weight 300g Cabling Schematic: Power Supply Bat Vin +8 to +30V DC Gnd Gnd 0V DC Backup battery A power supply of minimum 20V DC is required to charge the external battery. When the voltage at Vin disappears, the battery powers TBox LT2 down to 10V. Below 10V, the battery is automatically disconnected. The Gnd connection should be used only for power supply. Do not use it to cable analogue inputs (see Appendix H in The TBox LT2 User guide).

Cabling Schematic: (built-in) Cabling to a PC (DTE DTE cabling) DB9 Female to PC Cabling Schematic: (built-in) Example: Cabling TBox LT2 to TBox MS16 About cabling: Use a twisted pair for signal A and B. is not isolated. If cabling equipment in different buildings (different Earth), you have to use ACC- (ask your local distributor). Maximum length depends on quality of cable, speed and quantity of stations (max. 256 TBox stations). In good condition, guaranteed to 1.2km (max. 256 TBox stations at 9600Bps). In practice, longer distance can be reached with lower Baudrate and fewer stations. Cable Twisted pair (2 pairs: one pair for A and B; one pair for Gnd) Cross-section: minimum 0.5mm² Screening: pair and global screening Reference: Li2YCY-PiMF

Cabling Schematic: Straight pinned CAT5 shielded cable or Crossover CAT5 shielded cable: Technical specifications may change without prior notice www.servelectechnologies.com Servelec Technologies has a global network of offices and distributors. To find your local office, visit www.servelec-group.com/technologies/contact