Guardian2 Multi-Agent Monitoring Station

Similar documents
Microdust Pro Real-Time Dust Monitor

USER MANUAL. Guardian2 & Casella 24/7 Data Management System. HB March

USER MANUAL. Guardian2 & Casella 24/7 Data Management System. HB April

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

Dräger Polytron 8200 Stationary gas detector (CatEx)

MET ONE HHPC+ Series Handheld Particle Counters. Simple Fast MET ONE MET ONE

Dri-Block Heaters DB-2A DB-2D & DB-2DH DB-2D

Exposure Monitoring HEALTH AND SAFETY

Gas detection just got personal

Model KB 400 Cooling incubators with compressor technology

Valor TM 3000 Xtreme

CEL-350 dbadge / CEL-352 dbadge Plus Personal Sound Exposure Meter

Key Features. Applications

The Micronics U-100 U-100 GPRS. At the heart of your modular clamp-on flow and energy monitoring solution. Local Displays. CalecST Heat Meter

MX 62 CONTROLLER. Certifications. Better detection. Better protection. Monitoring system for gas and flame detection

See more with the NEW testo 880 thermal imager

IRtec Rayomatic 60. Fiber Optic Infrared Thermometer INFRARED THERMOMETERS. "Excellence in measurements" 2-wire, 4-20 ma Transmitter

The Apex, for professional air sampling in all monitoring scenarios

Infrared temperature measuring instrument

CEL-350 dbadge Series

EAGLE IMAGER 320 T H E R M A L I M A G I N G C A M E R A S T H E N E X T G E N E R A T I O N

Sulfur-in-Oil Analyzer SLFA-60

PAGING H ORN S PEAKERS

Page Station Module Replacements Page/Talk, Page/Party & Third-Party

RST100 Alert & Tracking Solutions

Pro II. Sound Level Meter V-9992

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Easidew Portable Hygrometer

MONITOR MR5S/MR5SW. Compact Two-Way Speaker. Safety First! Quick-Start Guide

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TOUGHER THAN THE REST

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

EPIC 3 RI VOICE COMMUNICATION SYSTEM

DEEP SEA ELECTRONICS DSE890 / DSE891 GATEWAY INSTALLATION INSTRUCTIONS

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

Data Sheet for Linear Sensors

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

Strip Chart Recorders Specification Sheet

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

MONITOR MR4/MR4W. Compact Two-Way Speaker. Safety First! Quick-Start Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)

Digital Outdoor Intercom Station DA/DAE 0x5 Series

8-Outlet eco PDU PE6208AV

SM00 _ MENHIR STRONG MOTION SYSTEM

GEA GROUND AND BUILDING VIBRATION

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Surge Protection Products for the small office/home office and professional grade

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Quick Start Guide BEC G/LTE Outdoor Router

SV 277 Pro User Guide. Assembling the system. What's inside? Before you go on site

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

REFO Glossmeters for superior Gloss Quality

ECO PDU PE7108/PE7208

MKE 600. Perfect Sound.

/ Outdoor Diplexer DPO-6789B-X-XX

An AED with a view. Never fear. Rescue ready.

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Connevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

ECO PDU PE5108/PE5208

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

CS-1 Active Full Range Integrated Commercial Audiovisual System

Tecal Series of Dri-Block Calibrators

WIRELESS ENVIRONMENTAL MONITORS

Industrial 1-Port Ultra PoE to 2-Port 802.3bt/at Gigabit PoE Extender

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

GRAS 42AG Multifunction Sound Calibrator, Class 1

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Adventurer TM Pro Analytical and Precision Balances

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

IS.3. Post Top Module (PTM)

FLUIDWISE DRIVES & CONTROLS ARTIFICIAL LIFT SYSTEMS. franklin-energy.com

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Hot pluggable communication modules

Introducing Lifeline PRO

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

wattch TOOLBOX-ETH-GPRS EWATTCH Toolbox User Guide CONNECTED SOLUTIONS FOR ENERGY CONTROL

CR:514 & CR:515 Acoustic Calibrator Page 1. CR:514 & CR:515 Acoustic Calibrator User Manual

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

VT608 / Switched PDU with 8 outlets

Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies

ECO PDU. Features. PE5220sA

Digital Sound Level Meter MODEL

WHIRLYBIRD AUTOMATIC WEATHER STATION. Whirlybird Electronics Pvt Ltd 140, 2 nd Cross 13 th Main, BTM-I Bangalore

Ecotel Free Cool 5-15kW

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Keysight U8030 Series Triple-Output DC Power Supplies

Vibracord FX. The perfect equipment for your. measurement. Vibracord FX in aluminum case. Frequency response: Hz Hz

Specifications and Part Numbers

Digital Sound Level Meter

Fully Automated Formalin Mixing and Dispensing Station

Data Transmitter 795. Data sheet

CEL 240 Series Digital Sound Level Meters Frequently Asked Questions

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

Guardian2 Multi-Agent Monitoring Station Guardian2 is designed to help you remain compliant with site emission levels, using remote monitoring and reporting of noise, dust and vibration.

Key Features Real-time particulate, noise and ground vibration (PPV) Simultaneous PM10, PM2.5 and PM1.0 monitoring Web-hosted data with secure, password protected login Optional, maintenance free windspeed & direction sensor Email and text alerts to nominated recipients Manual or automatic reports IEC 61672-1 compliant sound level meter Wall or pole mounted Operates over a wide operating voltage 100-250 VAC Guardian2 is a web-based remote monitoring system for noise, particulates and ground vibration, either as single agents or in multiple combinations. It is ideal for construction & demolition sites plus many more fence-line applications. Where compliance with limits is required and good relationships with neighbouring people and businesses are a must, Guardian2 can guarantee the smooth progress of your project or manufacturing operations. With the new mhub, data can be streamed straight to your mobile device... Cloud Hosting The Guardian2 advanced mhub datalogger and web connectivity allows data to be continuously sent to the cloud. Alerts and status reports can be seamlessly delivered to your mobile device.

Configure Reports The mhub datalogger incorporates an electronic SIM which means that the system will search for the strongest cellular signal but in the event of a lack of connectivity, the mhub will continue to log then push the stored data to the server when communication is re-established. The Casella 24/7 Data Management System is accessible via a secure log-in, giving organisational administrators and nominated users access rights to data, reports and alerts. Plug In and Play Integrated into a small, unobtrusive environmentally sealed housing, Guardian2 can be configured at the time of ordering for a variety of agents depending upon the specific application or requirements. Installation couldn t be simpler; just bolt to a wall or mount on a pole, apply power and then within a few moments begin transmitting data using cellular connectivity to a secure server. For single or multiple agents at once e.g. noise and dust Automatic reports can be set to report daily, weekly or monthly data, direct to your inbox Graphical or tabular reports Alert Configuration Configure alerts by text or email Can be configured for any measured parameter Error alerts, e.g. for power loss User Configuration Different levels of access can be configured to casella247.com Specify who just receives reports, or administrator access to configure reports and Guardian2 units Configure Guardian2 units on different sites remotely Report showing 15 minute average PM10 levels Reporting and alerts Administrators can choose the number of Users who have access to data and receive alerts while Users themselves can create and edit reports and because there can be multiple sites and Guardians they can easily switch between them. Reports can be created manually or automatically and can be sent by email to multiple recipients if required. Alerts can be generated when specified limits are exceeded as well as notification of power and communications outages should data not be received when expected by the system. Action can then be taken to investigate the causes of these exceedances to head off potential complaints or citations as well as checking for integrity of the Guardian2 itself. Report showing noise data over two weeks

Specification Ordering Information Noise: Accuracy: Class 1 to IEC61672-1 Parameters: L Aeq, L Amax, L A10%, L A90% Measurement range: 20-140dB RMS Calibration: Via provided acoustic CEL-120/1 Particulate: Sensitivity: Zero stability: Size fractions: Inlet: 1ug/m3 +/-2ug/m3 Simultaneous PM10, PM2.5 & PM1.0 Heated to reduce moisture affecting measurements Vibration: Transducer type: Geophone Number of channels: 3-axis Frequency range: Measurement Range: 2-250 Hz +/- 200 mm/s Accessories Part Number Environmental rating: 0.01 mm/s IP65 Replacement windshield enclosure system: 208041C Winds Speed and Direction Sensor: Wind Speed: 0-60m/s Accuracy: +/-2% 0.01m/s Threshold: 0.01m/s Wind Direction: 0-359 (No Deadband) Accuracy: +/-3% 0.1 degrees Windshield enclosure System extension kit (includes 5m windshield extension cable, mounting bracket & U-bolt and tripod/pole mounting bracket): Spare 5m windshield extension cable: Replacement foam: 208104D 208083C 208022C General: Enclosure Protection: IP65 Particulate Inlet Operating Humidity: <5% to 100% Logger: Inbuilt logger data transmission via GPRS Power: 100-250VAC Mounting: Wall or pole mounted (50mm pole). Dimensions: 400mm x 300mm x 150mm Weight: <13kg Wind Speed & Direction Sensor Microphone Protection System Data Antenna Particulate Outlet Power Connection

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.