Instruction Manual. 24" and 48" Waterproof Electronic Digital Level Model Nos &

Similar documents
Instruction Manual. 24" and 48" Electronic Digital Level Model Nos &

Instruction Manual. Electronic Horizontal & Vertical Self-Leveling Rotary Laser Level Model Nos , ,

Operating instructions: STABILA Electronic-IP65

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

Digi-Pas Innovation & Technology Driven

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

Digi-Pas Innovation & Technology Driven

Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.

Digi-Pas Innovation & Technology Driven

Auto-leveling Rotating Laser (RL430G)

Digital Torque Angle Adapter USER MANUAL

Thank you very much for purchasing LAISAI LS686 line laser, please read this instruction manual before operating it. Content

DE EN FR. S-Digit multi + BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

USER GUIDE. Coating Thickness Tester. Model CG104

Self-leveling Laser Marker (4V1HXL)

Dual Moisture Meter Pin / Pinless Moisture Meter

TEL: / FAX:

LSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :

LED Wall Clock With Calendar and Temperature Display

User Manual GBS-1269BT. Body Scale 4.0. version:1.0. Distributed by: Informed Clinical Sciences Corporation 1 Joy Street, Boston, USA MA 02108

PROTIMETER. TimberMaster. Protimeter Moisture Meter (BLD5605, BLD5609, BLD5605-SW, BLD5609-SW) Instruction Manual. Amphenol.

Amphenol PROTIMETER. Advanced Sensors. Digital Mini. Protimeter Moisture Meter. Instruction Manual

Surveymaster %WME DRY. Pro meter. Instruction Manual 99 Washington Street Melrose, MA Phone Toll Free

Green Rotary Laser Level

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Aquant. GE Measurement & Control. Protimeter Non-Invasive Moisture Meter. Instruction Manual

1. PRECAUTIONS. Thank you for choosing RUIDE theodolite Disteo 23. Please read this manual carefully before use.

Indoor Air Quality Meter/Datalogger

Amphenol PROTIMETER. Advanced Sensors. Digital Mini. Protimeter Moisture Meter. Instruction Manual

LS516/LSG516 Self-leveling Rotating Laser Instruction Manual ( )

LA 90L / LA 180L. Operating instructions

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

FastCam Outdoor Speed Dome Camera

RF-Link 2.4GHz Digital Wireless Color Security/Baby Monitor. Model: ABM-4161 User's Manual

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Sound Level Pen Instruction Manual

VERTICAL CONTROL LASER OWNERS MANUAL

Manual Sound level indicator PCE-353

LDM M LASER DISTANCE MEASURER

Bluelab ph Meter TM Instruction Manual

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

PRO 360. Owner's Manual

Wingmate Rover Components

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Mode / Sensitivity (-) LED

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

User Manual. Hand-held Laser Distance Meter

TL-Series. User Manual. American Weigh Scales. TL-330 (330lb x 0.2lb) TL-440 (440lb x 0.5lb)

ECOLINE EL 515 PLUS EL 515 PLUS SET

B R E A T H A L Y S E R

AutoRanging Digital MultiMeter

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

from P.R.Engineering Ltd Tel:

315 ph/ion. Installation. Specifications. Installing the Batteries a595. Input Connectors

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

SR200 GPS SPORTS WATCH. Keeping you one step ahead. User manual

OHAUS SCOUT BALANCE SCALE

WK7200. Water Quality Test Kit USER S MANUAL

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Luna. Instruction Manual

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Video Borescope Inspection Camera

Contents Introduction... Effective Use of Your Pager.. Features... Getting Started... Battery Information... Installing/Replacing the Battery...

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

PRO 360. Owner's Manual

Portable Conductivity Meter M1410. User Manual 1.002

Psychrometer/Anemometer. Instruction Manual

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

Pro II. Sound Level Meter V-9992

Receiver REC 300 Digital. Operating instructions

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

IDS-801 Series Compact Bench Counting Scale. User Manual

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Vibration Meter Instruction Manual

SuperHeat Psychrometer Models RH350 and RH355 (kit)

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

I. BASIC OPERATION (PREPARATION)

User Guide. Moisture Meter. Model MO250

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

INSTRUCTION MANUAL CAT ecount

USER MANUAL 16PXL BOARD RGB 16PXL MODULE RGB (4PXL ADD-ON STRIP 62.5) (4PXL ADD-ON BOARD 62.5)

Device Introduction. Control Unit. IP Rating: IP67 - Dust resistant and waterproof up to 1 meter depth. 360 Detection Tip.

BODY SCANNER METAL DETECTOR

PIN-TYPE LCD MOISTURE METER

Contents Introduction 2 Getting Started 3 Messages Function Menus Contents Maintenance

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Transcription:

7640H-English_Manuals 12/11/13 4:18 PM Page 1 24" and 48" Waterproof Electronic Digital Level Model Nos. 1880-2400 & 1880-4800 Instruction Manual Congratulations on your choice of this Digital Level. We suggest you read this instruction manual thoroughly before using the instrument. Save this instruction manual for future use. 2013 Johnson Level & Tool - Rev. 1 1

7640H-English_Manuals 12/11/13 4:18 PM Page 2 Table of Contents 1. Kit Contents 2. Features and Functions 3. Location of Parts/Components 4. Operating Instructions 1. Kit Contents 5. Using the Product 6. Self-Calibration 7. Technical Specifications 8. Care and Handling 9. Product Warranty Description Model Nos. 1880-2400 & 1880-4800 Qty. Electronic Digital Level 1 Instruction Manual 1 Carrying Case 1 2. Features and Functions IP 65 dust and waterproof Extremely accurate with 0.05º at 0º and 90º Angle inclination in 5 construction languages - units of measure (degrees, percent, in/ft (fractional), in/ft(decimal), mm/m) Self-calibrate Automatic digit inversion for overhead measurements Reference function making any slope 0.0 Hold function locks measurement on the LCD Working range on angle measurement 4 x 90º SurroundView vials reflect ambient light for easy-read 2 2013 Johnson Level & Tool - Rev. 1

7640H-English_Manuals 12/11/13 4:18 PM Page 3 Two vials read plumb and level Bright LCD backlight Audible and visual plumb and level indicators Shock absorbing end-caps Large hand grips fastened with screws Rigid aluminum box frame profile 3. Location of Part/Components End-cap LCD Display Window Plumb Vial Hand Hole Keypad Level Vial End-cap 2013 Johnson Level & Tool - Rev. 1 3

7640H-English_Manuals 12/11/13 4:18 PM Page 4 4. Operating Instructions IMPORTANT: It is the responsibility of the user to verify the calibration of the instrument before each use. Battery Installation 1. Turn the digital level off. 2. Open the battery panel by removing the battery panel screw. 3. Remove the old batteries and put in new ones. 4. Turn on the unit to see if all functions are correct. Note: 1. Be careful to follow the polarity symbol when replacing the batteries. 2. Take out the batteries if the digital level is not going to be used for a long time. Battery Panel Screw 4 2013 Johnson Level & Tool - Rev. 1

7640H-English_Manuals 12/11/13 4:18 PM Page 5 5. Using the Product Key Guide Sound Symbol Reference Symbol Hold Symbol millimeters/ meter Symbol inch/feet Symbol Percent Symbol Degree Symbol Battery Symbol RES Button Hold Button Direction Arrow Symbol Mode Button On/Off Button Sound Button Reference Button Calibrate Button LCD Backlight Button ON/OFF Button Push this button once to turn on the digital level. Push this button again to turn the digital level off. RES Button Push this button once to switch the resolution of the digital level from 0.05º to 0.1º. Mode Button Push this button once to switch from one unit of measure to another. This controls which unit of measure your digital level will measure in. Your level has the capability to measure in degrees, percentage of 2013 Johnson Level & Tool - Rev. 1 5

7640H-English_Manuals 12/11/13 4:18 PM Page 6 slope, inches/feet in fractions, inches/feet in decimal and millimeters/ meters. A symbol at the top of the LCD will show which unit of measure you are currently in. Push and hold this button in for 3 seconds and then release to enter the automatic shut off mode (5 minutes or 2 hours). When the button is held in for 3 seconds and released the LCD will show a 5 blinking 3 times and then return to the regular display, the automatic shut off is now set to 5 minutes. When the button is held in for another 3 seconds and released the LCD will show a 2H blinking 3 times and then return to the regular display, the battery symbol will be displayed as a reminder that the digital level is now set for 2 hours. The default setting is for automatic shut off in 5 minutes. NOTE: When the battery is low (less than 5%) the digital level will default to 5 minute automatic shut off, the battery symbol will begin to flash and there will be no response to pushing this button in for 3 seconds. Reference Button Push this button once to enter Reference Mode. The reference function allows for setting any angle or slope to 0.0. This is very useful for measuring the same slope continuously during a project or finding the difference between two slopes. To set the reference function, position the level at the desired angle you wish to measure. Press and release the reference button. REF will appear on the screen while in the reference mode and the numbers will go to 0.0. Set the level on the second surface to measure the difference between the first and second surface. To exit this reference mode, press the reference button again. 6 2013 Johnson Level & Tool - Rev. 1

7640H-English_Manuals 12/11/13 4:18 PM Page 7 Hold Button Push this button once to enter hold mode. Pressing this button once will lock the current angle reading displayed on the LCD. The word HOLD will appear at the top of the display to remind you that you are in the HOLD function. Press this button once again to exit the hold mode. Sound Button Push this button once to enter the sound function mode. The sound symbol will appear on the LCD and there will be 4 different types of sound. 1. Between 10-5 or 80-85 there is a slow beep 2. Between 4.9-1 or 85.1-89 there is a faster beep 3. Between 0.9-0.1 or 89.1-89.9 there is a rapid beep 4. 0 and 90 there is a continuous sound Press this button again to exit the sound mode. The sound will turn off after 20 seconds of non-movement of the digital level. The sound will return when the digital level is moved. Backlight Button Push this button once to turn on the backlight function. The LCD backlight will stay on for approximately 30 seconds with no movement of the level. Any push of a button or movement of the level will turn the backlight back on. To exit the backlight function, push this button again. Calibrate Button Push this button to enter calibration mode. See Calibration section for more information on how to calibrate this digital level. 2013 Johnson Level & Tool - Rev. 1 7

7640H-English_Manuals 12/11/13 4:18 PM Page 8 Auto Shut-Off The digital level will automatically shut-off in 5 minutes if no key is pressed. NOTE: This can be changed to a 2 hour automatic shut-off, please see MODE function. Erro Reading An error reading on the LCD indicates the level is tipped too far forward or backward to display an accurate reading. Inclination Indication The left and right arrows are displayed to indicate the inclination direction of the digital level. When the digital level is at the position of 0 degree, the horizontal reference line will show as follows: 8 2013 Johnson Level & Tool - Rev. 1

7640H-English_Manuals 12/11/13 4:18 PM Page 9 6. Self-Calibration IMPORTANT: It is the responsibility of the user to verify the calibration of the instrument before each use. To Calibrate this unit: Quick Level Calibration 1. Turn the digital level on. 2. Hold the digital level against a wall making sure the level bubble is centered in the vial. 3. While keeping the digital level in the level position push and hold the CAL button in for 3 seconds. 4. CAL will flash on the LCD indicating the digital level is in the calibration process. 5. If the digital level is not kept stable or if the digital level is tipped to far forward or backward, ERRO will appear on the LCD. Push the Calibration Button one time to exit calibration mode and repeat the procedure. 6. If the calibration procedure is successful, the LCD will display rdy. The calibration procedure is completed and the digital level will exit the calibration procedure automatically. Quick Plumb Calibration 1. Turn the digital level on. 2. Hold the digital level against a wall making sure the plumb bubble is centered in the vial. 3. While keeping the digital level in the plumb position push and hold the CAL button in for 3 seconds. 2013 Johnson Level & Tool - Rev. 1 9

7640H-English_Manuals 12/11/13 4:18 PM Page 10 4. CAL will flash on the LCD indicating the digital level is in the calibration process. 5. If the digital level is not kept stable or if the digital level is tipped to far forward or backward, ERRO will appear on the LCD. Push the Calibration Button one time to exit calibration mode and repeat the procedure. 6. If the calibration procedure is successful, the LCD will display rdy. The calibration procedure is completed and the digital level will exit the calibration procedure automatically. Calibration 1. Select a flat horizontal platform as a reference surface, like a table surface. 2. With the digital level turned on, push the MODE button and CAL button at the same time for 3 seconds the release. 3. The LCD will show CAL1 indicating the digital level has entered the calibration process. 4. Push the CAL button one time and the LCD will show a flashing CAL1. 5. The LCD will then show a solid CAL2. 6. Rotate the level 180 putting it in the same position as it was before. 7. Push the CAL button one time. The LCD will display a flashing CAL2. 8. When the digital level is calibrated it will exit calibration mode automatically. 10 2013 Johnson Level & Tool - Rev. 1

7640H-English_Manuals 12/11/13 4:18 PM Page 11 7. Technical Specifications Display Range 4 x 90º Resolution 0.05º or 0.1º, 0.09% or 0.2%, 1/8", 0.125", 0.9mm/m or 2mm/m Accuracy ± 0.05º for 0º and 90º ± 0.1º for other angles Power Supply 2 AAA alkaline batteries (not included) Battery Life Approx. battery life 100 hours continuous use Working Temperature 32 F to 122 F (-10 C to +50 C) Dimensions 24" x 1" x 2.4" (610x25x61mm) (1880-2400) 48" x 1" x 2.4" (1220x25x61mm) (1880-4800) Weight 1.19 lbs (0.54kg) (1880-2400) 2.30 lbs (1.04kg) (1880-4800) IP Class 65 8. Care and Handling This unit is a precision tool that must be handled with care. Avoid exposing unit to shock vibrations and extreme temperatures. Before moving or transporting the unit, make sure that the unit is turned off. Remove the batteries when storing the unit for an extended time (more than three months) to avoid damage to the unit should the batteries deteriorate. Always store the unit in its case when not in use. Avoid getting the unit wet. Keep the unit dry and clean. Remove any moisture or dirt with a soft, dry cloth. Do not use harsh chemicals, strong detergents or cleaning solvents to clean the unit. 2013 Johnson Level & Tool - Rev. 1 11

7640H-English_Manuals 12/11/13 4:18 PM Page 12 9. Product Warranty Johnson Level & Tool offers a limited lifetime warranty on each of its products. You can obtain a copy of the limited warranty for a Johnson Level & Tool product by contacting Johnson Level & Tool's Customer Service Department as provided below or by visiting us online at www.johnsonlevel.com. The limited warranty for each product contains various limitations and exclusions. NOTE: The user is responsible for the proper use and care of the product. It is the responsibility of the user to verify the calibration of the instrument before each use. For further assistance, or if you experience problems with this product that are not addressed in this instruction manual, please contact our Customer Service Department. In the U.S., contact Johnson Level & Tool s Customer Service Department at 888-9-LEVELS. In Canada, contact Johnson Level & Tool s Customer Service Department at 800-346-6682. 12 2013 Johnson Level & Tool - Rev. 1