Siemens BACnet Programmable TEC Unit Vent Controller

Similar documents
Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

BACnet Terminal Box (VAV) Controller

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Siemens BACnet VAV Actuator

BACnet Protocol Implementation Conformance (PIC) Statement

PXC Compact Series on BACnet/IP

Dual Duct Controller - One Air Velocity

TC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1, July 31, 2008

oom Pressurization Con

PXC Modular Series for BACnet Networks

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

BACnet PTEC Controller Heat Pump Multi-Stage Slave Mode, Application Application Note Building Technologies

TB7300 Series Fan Coil Unit Communicating Thermostats BACnet Protocol Implementation Conformance Statement (PICS)

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

TALON Network Manager- 2 & 6 Express

Maverick I Commercial Packaged Rooftop Systems Unit Controller Protocol Implementation Conformance Statement (PICS) ANSI/ASHRAE , BACnet

PXC Modular Series. Features. Description. Technical Specification Sheet Document No July 24, 2012

TC Modular Series for BACnet Networks

TC Compact Series Unitary Equipment Controller

BACnet PTEC Unit Conditioner/Fan Coil P. Controller. Control Applications. Accessories. Product Description. Warning/Caution Notation

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

NS Series CO 2 Network Zone Sensors Protocol Implementation Conformance Statement

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Delta Control Unit (DCU) 3.30 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

TX-I/O Product Range. Description. Technical Specification Sheet Document No July 18, 2013

Compact Series Unitary Equipment Controller

WT-BAC-IP Gateway Protocol Implementation Conformance Statement

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

TEC Terminal Box (VAV) Controller

Andover ContinuumTM. b3850 Series Terminal Controllers

TEC Unit Conditioner Controller

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Field selectable application type and room module series, via dip-switches on controller

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

Delta Controller Engine (DCE) Firmware

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

BACnet PTEC Heat Pump Multi-Stage Controller. Control Applications. Product Description. Product Numbers. Warning/Caution Notation

BACnet. b3867 Terminal Controllers

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

ESAC ebacgw SNMP. Date: Mar 08,2009. Product Model Number: Product Version: 1.0 BACnet Protocol Revision: 3. Product Description:

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

NXAC-120 Area Controller

Sales and Engineering Data Sheet ED

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT (NORMATIVE) (This annex is part of this Standard and is required for its use.)

BACnet IP for Quantum

Heatronic Introduction. BAS Integration Manual. Table of Contents

Actuator Commissioning Tool

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

NB-VAV Family Protocol Implementation Conformance Statement (PICS)

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

ASHRAE s BACnet Protocol Implementation Conformance Statement (PICS)

NB-V3Tb Protocol Implementation Conformance Statement (PICS)

clarity 3 Programmable Controller

Delta ORCAview Date: August 5, 2009 Vendor Name: Delta Controls Inc. Product Name:

entelibus CPU Engine (eb-eng) Firmware

NB-ASC Family Protocol Implementation Conformance Statement (PICS)

TC Compact Series for BACnet Networks

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

BACnet Driver on the TC Series Platform

NS Series Temperature and Humidity Network Zone and Discharge Air Sensors Protocol Implementation Conformance Statement

RWD68U Universal Controller

Protocol Implementation Conformance Statement (Normative) BACnet Protocol Implementation Conformance Statement

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

System-10 BTU Meter BACnet Network Interface Installation Guide

FX Server BACNET AWS Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement

Modular Building Controller

Zoning System TEC2647Z-2 and TEC2647Z-2+PIR Zone Controllers Protocol Implementation Conformance Statement

SHEET. BASgatewayLX Modbus to BACnet Gateway. BASgatewayLX

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

BACnet Protocol Implementation Conformance Statement

PXC Compact Unitary Equipment Controller BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement (PICS)

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

FXVMA Variable Air Volume (VAV) Box Controller

Procon BAC-A/50. Installation Instructions MITSUBISHI ELECTRIC

LTEC Unit Ventilator DDC Controller

BACnet Protocol Implementation Conformance Statement (PICS)

Modular Series BACnet Protocol Implementation Conformance (PIC) Statement A6V Building Technologies

Power Modular Equipment Controller for BACnet Networks

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Room Pressurization Controller Pneumatic Output

Room Pressurization Controller Electronic Output

Honeywell ComfortPoint TM Open Plant Controller Protocol Implementation Conformance Statement (PICS)

Transcription:

Technical Specification Sheet Document No. 149-833 August 12, 2011 Siemens BACnet Programmable TEC Unit Vent Controller The Siemens BACnet PTEC Unit Vent Controller provides high performance Direct Digital Control (DDC) technology for room temperature control in unit ventilators. The Unit Vent Controller and related components provide an electronic control system. The Siemens BACnet PTEC Unit Vent Controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring and energy management functions and is designed to reside on any BACnet control system. The electronic approach to temperature control includes the following features. Features Communicates using BACnet MS/TP protocol for open communications on BACnet MS/TP networks. BTL listed as a B-ASC device. Programmable using PPCL. Setpoints and control parameters assigned and changed locally or remotely. Setpoints and control parameters stored in Electrically Erasable Programmable Read Only Memory (EEPROM) no battery backup required. Returns from power failure without operator intervention. No calibration required, thereby reducing maintenance costs. PID control of HVAC systems to minimize offset and maintain tighter setpoint control. Unique control algorithms for specific applications. Control capable of modulating 0-10V valve actuators and damper actuators. Optional Temperature Offset. Applications Slave Mode (Application 6595) Heating and/or Chilled Water Cooling, ASHRAE Cycles l and II (Application 6575) Heating and/or Chilled Water Cooling, ASHRAE Cycle III (Application 6576) Heating and DX Cooling, ASHRAE Cycles I and II (Application 6577) Heating and DX Cooling, ASHRAE Cycle III (Application 6578) Nesbitt Cycle W (Application 6579) Heating can be provided by hot water, steam or electric heat while cooling can be chilled water or DX coils. Page 1 of 5

Control algorithms are preprogrammed. The controller is ready to operate after selecting the application. If desired, the operator may adjust the room temperature setpoints and other parameters. The controller is designed for operation and modification without vendor assistance. If required, new custom code using our PPCL programming language can be added to replace or supplement the standard application residing in the controller. This provides the flexibility to meet many job specifications with the assurance of having a proven and tested standard application to rely upon. Hardware Controller Board The Siemens BACnet PTEC Unit Vent Controller consists of an electronic controller assembly. This controller provides all wiring terminations for system and local communication and power. The cable from the room sensor (purchased separately) connects to an RJ-11 jack on the controller. All other connections are removable terminal blocks. The controller assembly is mounted on a plastic track that mounts directly on the unit ventilator. An optional enclosure (P/N 550-002) protects the controller assembly. The controller interfaces with the following external devices: 0-10V Damper Spring Return Actuator 0-10V Valve Spring Return Actuator Temperature sensors (room and averaging) Portable Operator's Terminal DDC Automation Systems Digital input devices (dry contacts from motion sensors, alarm contacts) Digital output devices (fan, stages of electric heat, DX cooling, 2 position valves) Room Sensor The room sensor connection to the controller board consists of a quick-connect RJ-11 jack. This streamlines installation and reduces controller start-up time. Combination Temperature and Relative Humidity Models The Series 2200 range of TEC room units includes combination temperature and humidity models. For these models, both temperature and relative humidity values are passed digitally to the TEC. This information is passed from the room unit through the RJ-11 cable to the RTS port on the TEC. See the Series 2200 Temperature Room Units for TEC and ATEC Technical Specification Sheet (149-820), for more information. Unit Vent Controller Specifications Dimensions Weight Controlled Temperature Accuracy, Heating or Cooling Power Requirements Operating Range Power Consumption Inputs Analog Digital Outputs Analog Digital 4-1/8" W 11-1/4" L 1-1/2" H approx. 3 lbs (1.35 kg) ±1.5 F (0.9 C) 19.2 to 27.6 Vac, 50 or 60 Hz 10 VA (plus 12 VA per DO) 1 room temperature sensor 1 setpoint (optional at RTS) 2 auxiliary temperature sensor (10k thermistor) 1 selectable 0-10 Vdc/4-20 ma 2 dry contacts 3 0-10 Vdc 8 DO 24 Vac optically isolated solid state switches @ 0.5 amp Page 2 of 5

Communications Remote BACnet MS/TP (EIA 485), 9600 bps to 76800 bps FLN Trunk Local Ambient Conditions Storage Temperature Operating Temperature Humidity Range WCIS and PTEC Tool -40 F to 167 F (-40 C to 75 C) 32 F to 122 F (0 C to 50 C) 0% to 92% (non-condensing) Document Information Technical Specification Sheets/Technical Instructions Room Temperature Sensors Series 2200 Document Part Number 149-820 Duct Temperature Sensor 149-134P25 Low Limit Detection Thermostat 155-016P25 Analog Sensors 10 K Ohm Thermistor 149-912, 149-915, and 149-916 Siemens Valves and Electronic Actuators Agency Listings UL Listing UL 916, PAZX 599 Series Zone Valves 2-Way, 3-Way Zone Valve Electric and Thermic Actuators 155-034 cul Listed Canadian Standards C22.2 No. 205-M1983, PAZX7 FCC Compliance 47 CFR Part 15 599 Series Zone Valves and Actuators Modulating, On/Off Spring Return, 2- Position Control 155-063 BTL Listed as a B-ASC device Ordering Information Description Siemens BACnet PTEC Unit Vent Controller Large enclosure for electronic controller without damper actuator (long board). Part Number 550-493P 550-002 Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. or company names mentioned herein may be the trademarks of their respective owners. 2011 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA +1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com. Document No.149-833 Printed in the USA Page 3 of 5

BACnet Protocol Implementation Conformance Statement s Model Number Protocol Software Firmware Siemens BACnet PTEC Unit Vent Controller 550-493P 4 (135-2004) 2.0.5.1 BE43 Date Tested: July 2011 B-ASC Vendor Information Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.buildingtechnologies.siemens.com/bt/us Description The controller is an integral part of Siemens controls system. The controller can operate stand-alone or can be networked to perform complex HVAC control, monitoring, and energy management functions. This controller communicates using BACnet MS/TP. BACnet Standardized Device Profile Device Profile Tested PTEC BACnet Application Specific Controller (B-ASC) Supported BACnet Interoperability Building Block (BIBBs) BIBB Name Tested PTEC DS-RP-B Data Sharing-ReadProperty-B DS-RPM-B Data Sharing-ReadPropertyMultiple-B DS-WP-B Data Sharing-WriteProperty-B DM-DDB-B Device Management-Dynamic Device Binding-B DM-DOB-B Device Management-Dynamic Object Binding-B DM-DDC-B Device Management-DeviceCommunicationControl-B DM-RD-B Device Management-ReinitializeDevice-B DM-BR-B Device Management-Backup and Restore-B DM-OCD-B Device Management-Object Creation and Deletion-B Page 4 of 5

Standard Object Types Supported Object Type Creatable Deletable PTEC Analog Input No No Analog Output Yes Yes Binary Input No No Binary Output Yes Yes Device No No File Yes Yes Program Yes Yes Data Link Layer Options Data Link and Options MS/TP master (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps MS/TP slave (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps Segmentation Capability Segmentation Type Supported Window Size: 32 (MS/TP product limited to 1) Able to transmit segmented messages No Able to receive segmented messages No Device Address Binding Static Device Binding Supported Yes Networking Options Static Device Binding Supported No Character Sets Charcter Sets Supported ANSI X3.4 Page 5 of 5